{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T16:07:05Z","timestamp":1779293225859,"version":"3.51.4"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2025,4,9]],"date-time":"2025-04-09T00:00:00Z","timestamp":1744156800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,4,9]],"date-time":"2025-04-09T00:00:00Z","timestamp":1744156800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"DFG","award":["SFB-854"],"award-info":[{"award-number":["SFB-854"]}]},{"DOI":"10.13039\/501100012320","name":"Otto-von-Guericke-Universit\u00e4t Magdeburg","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100012320","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Doc Ophthalmol"],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>To compare the photopic negative response of the multifocal ERG (mfERG<jats:sub>PhNR<\/jats:sub>) and the multifocal pattern electroretinogram (mfPERG) using DTL electrode (E<jats:sub>DTL<\/jats:sub>) vs skin electrode (E<jats:sub>SKIN<\/jats:sub>) in healthy young and old adults.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Ten \u201cYoung\u201d [20\u201327\u00a0years] and eight \u201cOld\u201d [60\u201372\u00a0years] participants took part in this study. The electrophysiological responses were recorded binocularly using E<jats:sub>DTL<\/jats:sub> and E<jats:sub>SKIN<\/jats:sub>. 5-way ANOVAs were applied to investigate the following factors on mfERG<jats:sub>PhNR<\/jats:sub>: i) ELECTRODE, ii) DILATATION, iii) AGE, iv) EYE, and v) ECCENTRICITY. For mfPERG, the same factors, except dilatation, were investigated applying 4-way ANOVAs. These were conducted for amplitude and peak time of different components as well as signal-to-noise-ratio (SNR).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Amplitudes of mfERG<jats:sub>PhNR<\/jats:sub> [mfPERG]-based E<jats:sub>SKIN<\/jats:sub> recording were reduced to 32\u201338% [37\u201338%] compared to E<jats:sub>DTL<\/jats:sub>, <jats:inline-formula>\n                <jats:alternatives>\n                  <jats:tex-math>$$p &lt; 0.001$$<\/jats:tex-math>\n                  <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>p<\/mml:mi>\n                      <mml:mo>&lt;<\/mml:mo>\n                      <mml:mn>0.001<\/mml:mn>\n                    <\/mml:mrow>\n                  <\/mml:math>\n                <\/jats:alternatives>\n              <\/jats:inline-formula>. This corresponded to SNR reduction to 80% [60%], <jats:inline-formula>\n                <jats:alternatives>\n                  <jats:tex-math>$$p &lt; 0.001$$<\/jats:tex-math>\n                  <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>p<\/mml:mi>\n                      <mml:mo>&lt;<\/mml:mo>\n                      <mml:mn>0.001<\/mml:mn>\n                    <\/mml:mrow>\n                  <\/mml:math>\n                <\/jats:alternatives>\n              <\/jats:inline-formula>. E<jats:sub>SKIN<\/jats:sub> based responses had shorter peak times, by 0.2\u20130.5\u00a0ms for N1 and P1, <jats:inline-formula>\n                <jats:alternatives>\n                  <jats:tex-math>$$p &lt; 0.05$$<\/jats:tex-math>\n                  <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>p<\/mml:mi>\n                      <mml:mo>&lt;<\/mml:mo>\n                      <mml:mn>0.05<\/mml:mn>\n                    <\/mml:mrow>\n                  <\/mml:math>\n                <\/jats:alternatives>\n              <\/jats:inline-formula>, [P1: 1.5\u00a0ms, <jats:inline-formula>\n                <jats:alternatives>\n                  <jats:tex-math>$$p &lt; 0.001$$<\/jats:tex-math>\n                  <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>p<\/mml:mi>\n                      <mml:mo>&lt;<\/mml:mo>\n                      <mml:mn>0.001<\/mml:mn>\n                    <\/mml:mrow>\n                  <\/mml:math>\n                <\/jats:alternatives>\n              <\/jats:inline-formula>]. Both age groups had comparable amplitudes and SNRs, but Young had shorter peak times, by 1.5\u20132.2\u00a0ms for N1 and P1, <jats:inline-formula>\n                <jats:alternatives>\n                  <jats:tex-math>$$p &lt; 0.05$$<\/jats:tex-math>\n                  <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>p<\/mml:mi>\n                      <mml:mo>&lt;<\/mml:mo>\n                      <mml:mn>0.05<\/mml:mn>\n                    <\/mml:mrow>\n                  <\/mml:math>\n                <\/jats:alternatives>\n              <\/jats:inline-formula> [3.7\u20134.2\u00a0ms for N1, P1, N2, <jats:inline-formula>\n                <jats:alternatives>\n                  <jats:tex-math>$$p &lt; 0.05$$<\/jats:tex-math>\n                  <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>p<\/mml:mi>\n                      <mml:mo>&lt;<\/mml:mo>\n                      <mml:mn>0.05<\/mml:mn>\n                    <\/mml:mrow>\n                  <\/mml:math>\n                <\/jats:alternatives>\n              <\/jats:inline-formula>]. Compared to dilated recordings, undilated mfERG<jats:sub>PhNR<\/jats:sub> amplitudes were reduced to 47\u201387%, <jats:inline-formula>\n                <jats:alternatives>\n                  <jats:tex-math>$$p &lt; 0.01$$<\/jats:tex-math>\n                  <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>p<\/mml:mi>\n                      <mml:mo>&lt;<\/mml:mo>\n                      <mml:mn>0.01<\/mml:mn>\n                    <\/mml:mrow>\n                  <\/mml:math>\n                <\/jats:alternatives>\n              <\/jats:inline-formula>, and peak times were delayed by 2.0\u201311.8\u00a0ms, <jats:inline-formula>\n                <jats:alternatives>\n                  <jats:tex-math>$$p &lt; 0.001$$<\/jats:tex-math>\n                  <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>p<\/mml:mi>\n                      <mml:mo>&lt;<\/mml:mo>\n                      <mml:mn>0.001<\/mml:mn>\n                    <\/mml:mrow>\n                  <\/mml:math>\n                <\/jats:alternatives>\n              <\/jats:inline-formula>.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>mfPERG &amp; mfERG<jats:sub>PhNR<\/jats:sub> traces were similar for E<jats:sub>DTL<\/jats:sub> and E<jats:sub>SKIN<\/jats:sub>. However, for skin electrodes, amplitudes and SNRs were lower and peak times shorter. E<jats:sub>SKIN<\/jats:sub> thus seem to be a viable alternative in patients in whom the use of corneal electrodes is precluded, e.g., children and disabled patients, but at the expense of SNR and with reference to E<jats:sub>SKIN<\/jats:sub> normative data.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1007\/s10633-025-10014-5","type":"journal-article","created":{"date-parts":[[2025,4,9]],"date-time":"2025-04-09T18:26:36Z","timestamp":1744223196000},"page":"137-153","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["DTL versus skin electrodes in recording of multifocal pattern electroretinogram and multifocal photopic negative response"],"prefix":"10.1007","volume":"150","author":[{"given":"Henrike Marie","family":"Nowitzki","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael B.","family":"Hoffmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2057-651X","authenticated-orcid":false,"given":"Khaldoon O.","family":"Al-Nosairy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,4,9]]},"reference":[{"key":"10014_CR1","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1007\/s10633-023-09932-z","volume":"146","author":"DL McCulloch","year":"2023","unstructured":"McCulloch DL, Bach M, Brigell M et al (2023) ISCEV guidelines for calibration and verification of stimuli and recording instruments (2023 update). Doc Ophthalmol 146:199\u2013210. https:\/\/doi.org\/10.1007\/s10633-023-09932-z","journal-title":"Doc Ophthalmol"},{"key":"10014_CR2","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1007\/BF00152771","volume":"71","author":"SG Coupland","year":"1989","unstructured":"Coupland SG, Janaky M (1989) ERG electrode in pedriatic patients: comparison of DTL fiber, PVA-gel, and non-corneal skin electrodes. Doc Ophthalmol 71:427\u2013433. https:\/\/doi.org\/10.1007\/BF00152771","journal-title":"Doc Ophthalmol"},{"key":"10014_CR3","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1038\/eye.1993.36","volume":"7","author":"L Esakowitz","year":"1993","unstructured":"Esakowitz L, Kriss A, Shawkat F (1993) A comparison of flash electroretinograms recorded from Burian Allen, JET, C-glide, gold foil, DTL and skin electrodes. Eye 7:169\u2013171. https:\/\/doi.org\/10.1038\/eye.1993.36","journal-title":"Eye"},{"key":"10014_CR4","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1007\/s10633-004-1751-3","volume":"109","author":"K Bradshaw","year":"2004","unstructured":"Bradshaw K, Hansen R, Fulton A (2004) Comparison of ERGs recorded with skin and corneal-contact electrodes in normal children and adults. Doc Ophthalmol 109:43\u201355. https:\/\/doi.org\/10.1007\/s10633-004-1751-3","journal-title":"Doc Ophthalmol"},{"key":"10014_CR5","doi-asserted-by":"publisher","first-page":"390","DOI":"10.5935\/0004-2749.20160110","volume":"79","author":"A Fernandes","year":"2016","unstructured":"Fernandes A, Salom\u00e3o S, Pereira J et al (2016) Full-field electroretinogram recorded with skin electrodes in normal adults. Arq Bras Oftalmol 79:390\u2013394. https:\/\/doi.org\/10.5935\/0004-2749.20160110","journal-title":"Arq Bras Oftalmol"},{"key":"10014_CR6","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1186\/s12886-016-0311-4","volume":"16","author":"A Lapkovska","year":"2016","unstructured":"Lapkovska A, Palmowski-Wolfe AM, Todorova MG (2016) Comparing DTL microfiber and Neuroline skin electrode in the Mini Ganzfeld ERG. BMC Ophthalmol 16:137. https:\/\/doi.org\/10.1186\/s12886-016-0311-4","journal-title":"BMC Ophthalmol"},{"key":"10014_CR7","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1007\/s10792-016-0240-5","volume":"37","author":"T Yamashita","year":"2017","unstructured":"Yamashita T, Miki A, Tabuchi A et al (2017) A novel method to reduce noise in electroretinography using skin electrodes: a study of noise level, inter-session variability, and reproducibility. Int Ophthalmol 37:317\u2013324. https:\/\/doi.org\/10.1007\/s10792-016-0240-5","journal-title":"Int Ophthalmol"},{"key":"10014_CR8","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1167\/tvst.7.6.27","volume":"7","author":"J Tang","year":"2018","unstructured":"Tang J, Hui F, Hadoux X et al (2018) A comparison of the RETeval sensor strip and DTL electrode for recording the photopic negative response. Transl Vis Sci Technol 7:27\u201327. https:\/\/doi.org\/10.1167\/tvst.7.6.27","journal-title":"Transl Vis Sci Technol"},{"key":"10014_CR9","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1167\/tvst.5.2.13","volume":"5","author":"Z Wu","year":"2016","unstructured":"Wu Z, Hadoux X, Fan Gaskin JC et al (2016) Measuring the photopic negative response: viability of skin electrodes and variability across disease severities in glaucoma. Transl Vis Sci Technol 5:13\u201313. https:\/\/doi.org\/10.1167\/tvst.5.2.13","journal-title":"Transl Vis Sci Technol"},{"key":"10014_CR10","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1007\/s10633-010-9239-9","volume":"121","author":"KE Mortlock","year":"2010","unstructured":"Mortlock KE, Binns AM, Aldebasi YH et al (2010) Inter-subject, inter-ocular and inter-session repeatability of the photopic negative response of the electroretinogram recorded using DTL and skin electrodes. Doc Ophthalmol 121:123\u2013134. https:\/\/doi.org\/10.1007\/s10633-010-9239-9","journal-title":"Doc Ophthalmol"},{"key":"10014_CR11","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1007\/BF02580858","volume":"94","author":"DL McCulloch","year":"1997","unstructured":"McCulloch DL, Van Boemel GB, Borchert MS (1997) Comparisons of contact lens, foil, fiber and skin electrodes for patterns electroretinograms. Doc Ophthalmol 94:327\u2013340. https:\/\/doi.org\/10.1007\/BF02580858","journal-title":"Doc Ophthalmol"},{"key":"10014_CR12","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1007\/s10633-013-9412-z","volume":"127","author":"M Bach","year":"2013","unstructured":"Bach M, Ramharter-Sereinig A (2013) Pattern electroretinogram to detect glaucoma: comparing the PERGLA and the PERG ratio protocols. Doc Ophthalmol Adv Ophthalmol 127:227\u2013238. https:\/\/doi.org\/10.1007\/s10633-013-9412-z","journal-title":"Doc Ophthalmol Adv Ophthalmol"},{"key":"10014_CR13","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1159\/000076890","volume":"36","author":"AS Neubauer","year":"2004","unstructured":"Neubauer AS, Stiefelmeyer S, Berninger T et al (2004) The multifocal pattern electroretinogram in chloroquine retinopathy. Ophthalmic Res 36:106\u2013113. https:\/\/doi.org\/10.1159\/000076890","journal-title":"Ophthalmic Res"},{"key":"10014_CR14","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1167\/tvst.9.12.7","volume":"9","author":"KO Al-Nosairy","year":"2020","unstructured":"Al-Nosairy KO, Prabhakaran GT, Pappelis K et al (2020) Combined multi-modal assessment of glaucomatous damage with electroretinography and optical coherence tomography\/angiography. Trans Vis Sci Tech 9:7\u20137. https:\/\/doi.org\/10.1167\/tvst.9.12.7","journal-title":"Trans Vis Sci Tech"},{"key":"10014_CR15","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1016\/0042-6989(92)90235-B","volume":"32","author":"EE Sutter","year":"1992","unstructured":"Sutter EE, Tran D (1992) The field topography of ERG components in man\u2014I. The photopic luminance response. Vis Res 32:433\u2013446. https:\/\/doi.org\/10.1016\/0042-6989(92)90235-B","journal-title":"Vis Res"},{"key":"10014_CR16","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1007\/s10633-020-09812-w","volume":"142","author":"MB Hoffmann","year":"2021","unstructured":"Hoffmann MB, Bach M, Kondo M et al (2021) ISCEV standard for clinical multifocal electroretinography (mfERG) (2021 update). Doc Ophthalmol 142:5\u201316. https:\/\/doi.org\/10.1007\/s10633-020-09812-w","journal-title":"Doc Ophthalmol"},{"key":"10014_CR17","doi-asserted-by":"publisher","first-page":"108242","DOI":"10.1016\/j.exer.2020.108242","volume":"200","author":"KO Al-Nosairy","year":"2020","unstructured":"Al-Nosairy KO, Thieme H, Hoffmann MB (2020) Diagnostic performance of multifocal photopic negative response, pattern electroretinogram and optical coherence tomography in glaucoma. Exp Eye Res 200:108242. https:\/\/doi.org\/10.1016\/j.exer.2020.108242","journal-title":"Exp Eye Res"},{"key":"10014_CR18","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.exer.2018.01.021","volume":"169","author":"M Bach","year":"2018","unstructured":"Bach M, Cuno A-K, Hoffmann MB (2018) Retinal conduction speed analysis reveals different origins of the P50 and N95 components of the (multifocal) pattern electroretinogram. Exp Eye Res 169:48\u201353. https:\/\/doi.org\/10.1016\/j.exer.2018.01.021","journal-title":"Exp Eye Res"},{"key":"10014_CR19","doi-asserted-by":"publisher","first-page":"1911","DOI":"10.1167\/jov.21.9.1911","volume":"21","author":"KO Al-Nosairy","year":"2021","unstructured":"Al-Nosairy KO, Horbr\u00fcgger M, Schippling S et al (2021) Structure-function relationship of retinal ganglion cells in multiple sclerosis. J Vis 21:1911\u20131911. https:\/\/doi.org\/10.1167\/jov.21.9.1911","journal-title":"J Vis"},{"key":"10014_CR20","doi-asserted-by":"publisher","first-page":"1158148","DOI":"10.3389\/fnint.2023.1158148","volume":"17","author":"KO Al-Nosairy","year":"2023","unstructured":"Al-Nosairy KO, Duscha A, Buhr H et al (2023) Functional and structural readouts for early detection of retinal involvement in multiple sclerosis. Front Integr Neurosci 17:1158148","journal-title":"Front Integr Neurosci"},{"key":"10014_CR21","doi-asserted-by":"publisher","DOI":"10.1007\/s10633-022-09912-9","author":"T Eckermann","year":"2022","unstructured":"Eckermann T, Hoffmann MB, Al-Nosairy KO (2022) Comparison of DTL and gold cup skin electrodes for recordings of the multifocal electroretinogram. Doc Ophthalmol. https:\/\/doi.org\/10.1007\/s10633-022-09912-9","journal-title":"Doc Ophthalmol"},{"key":"10014_CR22","first-page":"988","volume":"18","author":"W Dawson","year":"1979","unstructured":"Dawson W, Trick G, Litzkow C (1979) Improved electrode for electroretinography. Investig Opthalmol Vis Sci 18:988\u2013991","journal-title":"Investig Opthalmol Vis Sci"},{"key":"10014_CR23","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1016\/j.clinph.2007.10.005","volume":"119","author":"MB Hoffmann","year":"2008","unstructured":"Hoffmann MB, Flechner J-J (2008) Slow pattern-reversal stimulation facilitates the assessment of retinal function with multifocal recordings. Clin Neurophysiol 119:409\u2013417. https:\/\/doi.org\/10.1016\/j.clinph.2007.10.005","journal-title":"Clin Neurophysiol"},{"key":"10014_CR24","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1016\/0042-6989(85)90176-2","volume":"25","author":"H Heynen","year":"1985","unstructured":"Heynen H, van Norren D (1985) Origin of the electroretinogram in the intact macaque eye\u2013I. Principal component analysis. Vis Res 25:697\u2013707. https:\/\/doi.org\/10.1016\/0042-6989(85)90176-2","journal-title":"Vis Res"},{"key":"10014_CR25","first-page":"635","volume":"35","author":"RA Bush","year":"1994","unstructured":"Bush RA, Sieving PA (1994) A proximal retinal component in the primate photopic ERG a-wave. Invest Ophthalmol Vis Sci 35:635\u2013645","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10014_CR26","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1017\/s0952523800002431","volume":"11","author":"PA Sieving","year":"1994","unstructured":"Sieving PA, Murayama K, Naarendorp F (1994) Push-pull model of the primate photopic electroretinogram: a role for hyperpolarizing neurons in shaping the b-wave. Vis Neurosci 11:519\u2013532. https:\/\/doi.org\/10.1017\/s0952523800002431","journal-title":"Vis Neurosci"},{"key":"10014_CR27","first-page":"1124","volume":"40","author":"S Viswanathan","year":"1999","unstructured":"Viswanathan S, Frishman LJ, Robson JG et al (1999) The photopic negative response of the macaque electroretinogram: reduction by experimental glaucoma. Invest Ophthalmol Vis Sci 40:1124\u20131136","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10014_CR28","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1016\/S1350-9462(02)00061-7","volume":"22","author":"DC Hood","year":"2003","unstructured":"Hood DC, Greenstein VC (2003) Multifocal VEP and ganglion cell damage: applications and limitations for the study of glaucoma. Prog Retin Eye Res 22:201\u2013251. https:\/\/doi.org\/10.1016\/S1350-9462(02)00061-7","journal-title":"Prog Retin Eye Res"},{"key":"10014_CR29","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1007\/s10633-018-9638-x","volume":"136","author":"L Frishman","year":"2018","unstructured":"Frishman L, Sustar M, Kremers J et al (2018) ISCEV extended protocol for the photopic negative response (PhNR) of the full-field electroretinogram. Doc Ophthalmol 136:207\u2013211. https:\/\/doi.org\/10.1007\/s10633-018-9638-x","journal-title":"Doc Ophthalmol"},{"key":"10014_CR30","unstructured":"R Core Team. R: a language and environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria. Published Online First: 2023"},{"key":"10014_CR31","doi-asserted-by":"publisher","unstructured":"Park J (2023) Handbook of multiple comparisons. The American Statistician, vol 77, pp 234\u2013236. https:\/\/doi.org\/10.1080\/00031305.2023.2198355","DOI":"10.1080\/00031305.2023.2198355"},{"key":"10014_CR32","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1016\/0167-8760(89)90040-8","volume":"16","author":"A Kriss","year":"1994","unstructured":"Kriss A (1994) Skin ERGs: their effectiveness in paediatric visual assessment, confounding factors, and comparison with ERGs recorded using various types of corneal electrode. Int J Psychophysiol 16:137\u2013146. https:\/\/doi.org\/10.1016\/0167-8760(89)90040-8","journal-title":"Int J Psychophysiol"},{"key":"10014_CR33","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1007\/s10633-018-9652-z","volume":"137","author":"AE Hobby","year":"2018","unstructured":"Hobby AE, Kozareva D, Yonova-Doing E et al (2018) Effect of varying skin surface electrode position on electroretinogram responses recorded using a handheld stimulating and recording system. Doc Ophthalmol 137:79\u201386. https:\/\/doi.org\/10.1007\/s10633-018-9652-z","journal-title":"Doc Ophthalmol"},{"key":"10014_CR34","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1007\/s10633-006-9028-7","volume":"113","author":"T Schimitzek","year":"2006","unstructured":"Schimitzek T, Bach M (2006) The influence of luminance on the multifocal ERG. Doc Ophthalmol 113:187\u2013192. https:\/\/doi.org\/10.1007\/s10633-006-9028-7","journal-title":"Doc Ophthalmol"},{"key":"10014_CR35","first-page":"348","volume":"55","author":"M-S Mohamad-Rafiuddin","year":"2014","unstructured":"Mohamad-Rafiuddin M-S, Rosli S, Chen A-H et al (2014) The effects of non-dilated and dilated pupil at different eccentricity on multifocal electroretinogram. ARVO Meet Abstr 55:348","journal-title":"ARVO Meet Abstr"},{"key":"10014_CR36","doi-asserted-by":"publisher","first-page":"1","DOI":"10.5384\/sjovs.v14i1.123","volume":"14","author":"A-H Chen","year":"2021","unstructured":"Chen A-H, Mohamad-Rafiuddin M-S, Coupland SG (2021) Exogenous factors affecting multifocal electroretinogram: a mini review. Scand J Optom Vis Sci 14:1\u20139. https:\/\/doi.org\/10.5384\/sjovs.v14i1.123","journal-title":"Scand J Optom Vis Sci"},{"key":"10014_CR37","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1007\/s10633-008-9146-5","volume":"118","author":"CM Poloschek","year":"2009","unstructured":"Poloschek CM, Bach M (2009) Can we do without mydriasis in multifocal ERG recordings? Doc Ophthalmol 118:121\u2013127. https:\/\/doi.org\/10.1007\/s10633-008-9146-5","journal-title":"Doc Ophthalmol"},{"key":"10014_CR38","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1007\/s10633-016-9569-3","volume":"134","author":"AW Van Alstine","year":"2017","unstructured":"Van Alstine AW, Viswanathan S (2017) Test\u2013retest reliability of the multifocal photopic negative response. Doc Ophthalmol 134:25\u201336. https:\/\/doi.org\/10.1007\/s10633-016-9569-3","journal-title":"Doc Ophthalmol"},{"key":"10014_CR39","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1007\/s10633-015-9512-z","volume":"131","author":"A Kurtenbach","year":"2015","unstructured":"Kurtenbach A, Kernstock C, Zrenner E et al (2015) Electrophysiology and colour: a comparison of methods to evaluate inner retinal function. Doc Ophthalmol 131:159\u2013167. https:\/\/doi.org\/10.1007\/s10633-015-9512-z","journal-title":"Doc Ophthalmol"},{"key":"10014_CR40","doi-asserted-by":"publisher","first-page":"5024","DOI":"10.1167\/iovs.07-1309","volume":"49","author":"H Langrov\u00e1","year":"2008","unstructured":"Langrov\u00e1 H, Zrenner E, Kurtenbach A et al (2008) Age-related changes in retinal functional topography. Invest Ophthalmol Vis Sci 49:5024\u20135032. https:\/\/doi.org\/10.1167\/iovs.07-1309","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10014_CR41","doi-asserted-by":"publisher","first-page":"1268","DOI":"10.1136\/bjo.87.10.1268","volume":"87","author":"Y Rotenstreich","year":"2003","unstructured":"Rotenstreich Y, Fishman GA, Anderson RJ et al (2003) Interocular amplitude differences of the full field electroretinogram in normal subjects. Br J Ophthalmol 87:1268\u20131271. https:\/\/doi.org\/10.1136\/bjo.87.10.1268","journal-title":"Br J Ophthalmol"},{"key":"10014_CR42","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.ophtha.2004.07.018","volume":"112","author":"LM Ventura","year":"2005","unstructured":"Ventura LM, Porciatti V, Ishida K et al (2005) Pattern electroretinogram abnormality and glaucoma. Ophthalmology 112:10\u201319. https:\/\/doi.org\/10.1016\/j.ophtha.2004.07.018","journal-title":"Ophthalmology"},{"key":"10014_CR43","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1556\/aphysiol.97.2010.3.9","volume":"97","author":"A P\u00e1lffy","year":"2010","unstructured":"P\u00e1lffy A, Jan\u00e1ky M, Fejes I et al (2010) Interocular amplitude differences of multifocal electroretinograms obtained under monocular and binocular stimulation conditions. Acta Physiol Hung 97:326\u2013331. https:\/\/doi.org\/10.1556\/aphysiol.97.2010.3.9","journal-title":"Acta Physiol Hung"},{"key":"10014_CR44","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1097\/OPX.0000000000000193","volume":"91","author":"I Fejes","year":"2014","unstructured":"Fejes I, Kocsis PB, Benedek G et al (2014) Interocular amplitude and latency differences of pattern ERG and pattern VEP parameters. Optom Vis Sci 91:472\u2013476. https:\/\/doi.org\/10.1097\/OPX.0000000000000193","journal-title":"Optom Vis Sci"},{"key":"10014_CR45","doi-asserted-by":"publisher","first-page":"1879","DOI":"10.1167\/iovs.18-25272","volume":"60","author":"EKA Morny","year":"2019","unstructured":"Morny EKA, Patel K, Votruba M et al (2019) The relationship between the photopic negative response and retinal ganglion cell topography. Invest Ophthalmol Vis Sci 60:1879\u20131887. https:\/\/doi.org\/10.1167\/iovs.18-25272","journal-title":"Invest Ophthalmol Vis Sci"}],"container-title":["Documenta Ophthalmologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10633-025-10014-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10633-025-10014-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10633-025-10014-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T01:23:44Z","timestamp":1749086624000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10633-025-10014-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,9]]},"references-count":45,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,6]]}},"alternative-id":["10014"],"URL":"https:\/\/doi.org\/10.1007\/s10633-025-10014-5","relation":{},"ISSN":["0012-4486","1573-2622"],"issn-type":[{"value":"0012-4486","type":"print"},{"value":"1573-2622","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,9]]},"assertion":[{"value":"5 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 February 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest (such as honoraria; educational grants; participation in speakers\u2019 bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licensing arrangements), or nonfinancial interest (such as personal or professional relationships, affiliations, knowledge or beliefs) in the subject matter or materials discussed in this manuscript.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed were in accordance with the ethical standards of the institutional and\/or national research committee (Otto-von-Guericke University Hospital\/ OVGU ethical committee) and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This article does not contain any procedures with animals.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statement on the welfare of animals"}},{"value":"All procedures performed in this study were approved by the ethical committee of Otto-von-Guericke University and were in accordance with tenets of Helsinki Declaration.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statement of human rights"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}