{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T12:55:48Z","timestamp":1788353748055,"version":"build-2803163510"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2025,4,12]],"date-time":"2025-04-12T00:00:00Z","timestamp":1744416000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,4,12]],"date-time":"2025-04-12T00:00:00Z","timestamp":1744416000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["LI 2846\/5-1"],"award-info":[{"award-number":["LI 2846\/5-1"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["LI 2846\/6-1"],"award-info":[{"award-number":["LI 2846\/6-1"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100008967","name":"Philipps-Universit\u00e4t Marburg","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100008967","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Doc Ophthalmol"],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To introduce ERGtools2, an open-source R package for processing, analysing and long-term storing visual electrophysiology data.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A dataset comprising Electroretinogram (ERG) recordings of C57Bl\/6J mice, subjected to standard ISCEV stimuli, was used to present the functionality of ERGtools2. ERGtools2 stores and organizes all recordings, metadata, and measurement information from an individual examination in a single object, maintaining raw data throughout the analysis process.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>A standard workflow is presented exemplifying how ERGtools2 can be used to efficiently import, pre-process and analyse ERG data. Following this workflow, basic ERG measurements and visualisation of a single exam as well as group statistics are obtained. Moreover, special use cases are described, including for the handling of noisy data and the storage of data in the HDF5 format to ensure long-term preservation and accessibility.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>ERGtools2 provides a comprehensive, flexible, and device-independent solution for visual electrophysiology data analysis. Its emphasis on maintaining raw data integrity, combined with advanced processing and analysis capabilities, makes it a useful tool for preclinical and clinical research applications. The open-source nature and the use of open data formats promote reproducibility and data sharing in visual neurosciences.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s10633-025-10017-2","type":"journal-article","created":{"date-parts":[[2025,4,12]],"date-time":"2025-04-12T04:30:22Z","timestamp":1744432222000},"page":"169-175","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["The ERGtools2 package: a toolset for processing and analysing visual electrophysiology data"],"prefix":"10.1007","volume":"150","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4416-3421","authenticated-orcid":false,"given":"Moritz","family":"Lindner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,4,12]]},"reference":[{"issue":"12","key":"10017_CR1","doi-asserted-by":"publisher","first-page":"2399","DOI":"10.1038\/s41433-023-02491-2","volume":"37","author":"OA Mahroo","year":"2023","unstructured":"Mahroo OA (2023) Visual electrophysiology and \u201cthe potential of the potentials.\u201d Eye (Lond) 37(12):2399\u20132408. https:\/\/doi.org\/10.1038\/s41433-023-02491-2","journal-title":"Eye (Lond)"},{"issue":"3","key":"10017_CR2","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1007\/s10633-022-09872-0","volume":"144","author":"AG Robson","year":"2022","unstructured":"Robson AG, Frishman LJ, Grigg J, Hamilton R, Jeffrey BG, Kondo M et al (2022) ISCEV Standard for full-field clinical electroretinography (2022 update). Doc Ophthalmol 144(3):165\u2013177. https:\/\/doi.org\/10.1007\/s10633-022-09872-0","journal-title":"Doc Ophthalmol"},{"issue":"1","key":"10017_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10633-016-9553-y","volume":"133","author":"JV Odom","year":"2016","unstructured":"Odom JV, Bach M, Brigell M, Holder GE, McCulloch DL, Mizota A et al (2016) ISCEV standard for clinical visual evoked potentials: (2016 update). Doc Ophthalmol 133(1):1\u20139. https:\/\/doi.org\/10.1007\/s10633-016-9553-y","journal-title":"Doc Ophthalmol"},{"issue":"6\u20137","key":"10017_CR4","doi-asserted-by":"publisher","first-page":"902","DOI":"10.1016\/j.visres.2005.09.006","volume":"46","author":"WH Ridder 3rd","year":"2006","unstructured":"Ridder WH 3rd, Nusinowitz S (2006) The visual evoked potential in the mouse\u2013origins and response characteristics. Vision Res 46(6\u20137):902\u2013913. https:\/\/doi.org\/10.1016\/j.visres.2005.09.006","journal-title":"Vision Res"},{"key":"10017_CR5","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1007\/978-1-4939-7720-8_2","volume":"1753","author":"J Kremers","year":"2018","unstructured":"Kremers J, Tanimoto N (2018) Measuring retinal function in the mouse. Methods Mol Biol 1753:27\u201340. https:\/\/doi.org\/10.1007\/978-1-4939-7720-8_2","journal-title":"Methods Mol Biol"},{"issue":"8","key":"10017_CR6","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1167\/tvst.9.8.25","volume":"9","author":"LN Ayton","year":"2020","unstructured":"Ayton LN, Rizzo JF 3rd, Bailey IL, Colenbrander A, Dagnelie G, Geruschat DR et al (2020) Harmonization of outcomes and vision endpoints in vision restoration trials: recommendations from the international HOVER taskforce. Transl Vis Sci Technol 9(8):25. https:\/\/doi.org\/10.1167\/tvst.9.8.25","journal-title":"Transl Vis Sci Technol"},{"key":"10017_CR7","doi-asserted-by":"publisher","first-page":"160018","DOI":"10.1038\/sdata.2016.18","volume":"3","author":"MD Wilkinson","year":"2016","unstructured":"Wilkinson MD, Dumontier M, Aalbersberg IJ, Appleton G, Axton M, Baak A et al (2016) The FAIR guiding principles for scientific data management and stewardship. Sci Data 3:160018. https:\/\/doi.org\/10.1038\/sdata.2016.18","journal-title":"Sci Data"},{"issue":"1","key":"10017_CR8","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1007\/s10633-017-9618-6","volume":"136","author":"T Strasser","year":"2018","unstructured":"Strasser T, Peters T, Jagle H, Zrenner E (2018) ElVisML: an open data format for the exchange and storage of electrophysiological data in ophthalmology. Doc Ophthalmol 136(1):75\u201392. https:\/\/doi.org\/10.1007\/s10633-017-9618-6","journal-title":"Doc Ophthalmol"},{"key":"10017_CR9","unstructured":"R\u00a0Core\u00a0Team (2018) R: A language and environment for statistical computing. Vienna, Austria: R Foundation for Statistical Computing"},{"issue":"3","key":"10017_CR10","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1007\/s10633-007-9064-y","volume":"115","author":"LH Pinto","year":"2007","unstructured":"Pinto LH, Invergo B, Shimomura K, Takahashi JS, Troy JB (2007) Interpretation of the mouse electroretinogram. Doc Ophthalmol 115(3):127\u2013136. https:\/\/doi.org\/10.1007\/s10633-007-9064-y","journal-title":"Doc Ophthalmol"},{"key":"10017_CR11","unstructured":"The\u00a0HDF\u00a0Group: The HDF5 Data Format. https:\/\/www.hdfgroup.org\/solutions\/hdf5\/ (2024). Accessed 2024\/08\/11."},{"key":"10017_CR12","doi-asserted-by":"publisher","first-page":"101089","DOI":"10.1016\/j.preteyeres.2022.101089","volume":"91","author":"M Lindner","year":"2022","unstructured":"Lindner M, Gilhooley MJ, Hughes S, Hankins MW (2022) Optogenetics for visual restoration: from proof of principle to translational challenges. Prog Retin Eye Res 91:101089. https:\/\/doi.org\/10.1016\/j.preteyeres.2022.101089","journal-title":"Prog Retin Eye Res"},{"issue":"6","key":"10017_CR13","doi-asserted-by":"publisher","first-page":"3891","DOI":"10.1167\/iovs.13-11594","volume":"54","author":"HC Stronks","year":"2013","unstructured":"Stronks HC, Barry MP, Dagnelie G (2013) Electrically elicited visual evoked potentials in Argus II retinal implant wearers. Invest Ophthalmol Vis Sci 54(6):3891\u20133901. https:\/\/doi.org\/10.1167\/iovs.13-11594","journal-title":"Invest Ophthalmol Vis Sci"}],"container-title":["Documenta Ophthalmologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10633-025-10017-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10633-025-10017-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10633-025-10017-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,4]],"date-time":"2025-06-04T21:23:44Z","timestamp":1749072224000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10633-025-10017-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,12]]},"references-count":13,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,6]]}},"alternative-id":["10017"],"URL":"https:\/\/doi.org\/10.1007\/s10633-025-10017-2","relation":{"has-preprint":[{"id-type":"doi","id":"10.1101\/2024.08.27.609856","asserted-by":"object"}]},"ISSN":["0012-4486","1573-2622"],"issn-type":[{"value":"0012-4486","type":"print"},{"value":"1573-2622","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,12]]},"assertion":[{"value":"16 October 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"ML has received Grants from Bayer Healthcare outside the submitted work.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study did not involve human participants. Animal work was performed with approval of the relevant authorities and in accordance with the institutional Ethics Guidelines of Animal Care. Further details are provided in the Methods section.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to publish"}}]}}