{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T16:39:08Z","timestamp":1792514348525,"version":"4.5.0"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,8]],"date-time":"2026-05-08T00:00:00Z","timestamp":1778198400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,5,8]],"date-time":"2026-05-08T00:00:00Z","timestamp":1778198400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100001700","name":"Ministry of Education, Culture, Sports, Science and Technology","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001700","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100016003","name":"Mie University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100016003","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Doc Ophthalmol"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1007\/s10633-026-10107-9","type":"journal-article","created":{"date-parts":[[2026,5,8]],"date-time":"2026-05-08T06:39:39Z","timestamp":1778222379000},"page":"59-67","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Intra- and inter-examiner reliability of ERGs recorded with two types of skin electrodes"],"prefix":"10.1007","volume":"153","author":[{"given":"Ryunosuke","family":"Nagashima","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4172-3443","authenticated-orcid":false,"given":"Kumiko","family":"Kato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keitaro","family":"Mizumoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sumine","family":"Mori","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daisuke","family":"Kurose","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Iroha","family":"Fujimoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hisashi","family":"Matsubara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hidetaka","family":"Kudo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daphne L.","family":"McCulloch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mineo","family":"Kondo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,8]]},"reference":[{"key":"10107_CR1","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/S0039-6257(99)00063-6","volume":"44","author":"R Tzekov","year":"1999","unstructured":"Tzekov R, Arden GB (1999) The electroretinogram in diabetic retinopathy. Surv Ophthalmol 44:53\u201360","journal-title":"Surv Ophthalmol"},{"key":"10107_CR2","doi-asserted-by":"publisher","first-page":"36591","DOI":"10.1038\/srep36591","volume":"6","author":"M Fukuo","year":"2016","unstructured":"Fukuo M, Kondo M, Hirose A, Fukushima H, Ikesugi K, Sugimoto M et al (2016) Screening for diabetic retinopathy using new mydriasis-free, full-field flicker ERG recording device. Sci Rep 6:36591","journal-title":"Sci Rep"},{"key":"10107_CR3","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1001\/archopht.1988.01060130374025","volume":"106","author":"MA Johnson","year":"1988","unstructured":"Johnson MA, Marcus S, Elman MJ, McPhee TJ (1988) Neovascularization in central retinal vein occlusion: electroretinographic findings. Arch Ophthalmol 106:348\u2013352","journal-title":"Arch Ophthalmol"},{"key":"10107_CR4","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1136\/bjo.85.6.683","volume":"85","author":"J Larsson","year":"2001","unstructured":"Larsson J, Andreasson S (2001) Photopic 30\u00a0Hz flicker ERG as a predictor for rubeosis in central retinal vein occlusion. Br J Ophthalmol 85:683\u2013685","journal-title":"Br J Ophthalmol"},{"key":"10107_CR5","doi-asserted-by":"publisher","first-page":"5854","DOI":"10.1167\/iovs.18-25087","volume":"59","author":"R Miyata","year":"2018","unstructured":"Miyata R, Kondo M, Kato K, Sugimoto M, Matsubara H, Ikesugi K et al (2018) Supernormal flicker ERGs in eyes with central retinal vein occlusion: clinical characteristics, prognosis, and effects of anti-VEGF agent. Invest Ophthalmol Vis Sci 59:5854\u20135861","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10107_CR6","doi-asserted-by":"publisher","DOI":"10.1016\/j.xops.2022.100243","volume":"3","author":"K Kato","year":"2023","unstructured":"Kato K, Nagashima R, Matsubara H, Ikesugi K, Tsukitome H, Matsui Y et al (2023) Transient increase of flicker electroretinography amplitudes after cataract surgery: association with postoperative inflammation. Ophthalmol Sci 3:100243","journal-title":"Ophthalmol Sci"},{"key":"10107_CR7","doi-asserted-by":"publisher","DOI":"10.1007\/s10633-022-09872-0","author":"AG Robson","year":"2022","unstructured":"Robson AG, Frishman LJ, Grigg J, Hamilton R, Jeffrey BG, Kondo M et al (2022) ISCEV standard for full-field clinical electroretinography (2022 update). Doc Ophthalmol. https:\/\/doi.org\/10.1007\/s10633-022-09872-0","journal-title":"Doc Ophthalmol"},{"key":"10107_CR8","doi-asserted-by":"publisher","first-page":"3684","DOI":"10.1167\/iovs.14-16349","volume":"56","author":"K Kato","year":"2015","unstructured":"Kato K, Kondo M, Sugimoto M, Ikesugi K, Matsubara H (2015) Effect of pupil size on flicker ERGs recorded with RETeval system: new mydriasis-free full-field ERG system. Invest Ophthalmol Vis Sci 56:3684\u20133690","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10107_CR9","doi-asserted-by":"publisher","DOI":"10.1111\/aos.14618","author":"A Sugawara","year":"2020","unstructured":"Sugawara A, Kato K, Nagashima R, Ikesugi K, Sugimoto M, Matsubara H et al (2020) Effects of recording sequence on flicker electroretinographics recorded with natural pupils corrected for pupil area. Acta Ophthalmol. https:\/\/doi.org\/10.1111\/aos.14618","journal-title":"Acta Ophthalmol"},{"key":"10107_CR10","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1007\/s10792-016-0240-5","volume":"37","author":"T Yamashita","year":"2017","unstructured":"Yamashita T, Miki A, Tabuchi A, Funada H, Kondo M (2017) A novel method to reduce noise in electroretinography using skin electrodes: a study of noise level, inter-session variability, and reproducibility. Int Ophthalmol 37:317\u2013324","journal-title":"Int Ophthalmol"},{"key":"10107_CR11","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.1177\/1932296819882719","volume":"14","author":"JJ Wroblewski","year":"2020","unstructured":"Wroblewski JJ, McChancy C, Pickel K, Buterbaugh H, Wieland T, Gonzalez A (2020) Reproducibility of fixed-luminance and multi-luminance flicker electroretinography in patients with diabetic retinopathy using an office-based testing paradigm. J Diabetes Sci Technol 14:1095\u20131103","journal-title":"J Diabetes Sci Technol"},{"key":"10107_CR12","doi-asserted-by":"publisher","first-page":"8539747","DOI":"10.1155\/2017\/8539747","volume":"2017","author":"K Asakawa","year":"2017","unstructured":"Asakawa K, Amino K, Iwase M, Kusayanagi Y, Nakamura A, Suzuki R et al (2017) New mydriasis-free electroretinogram recorded with skin electrodes in healthy subjects. Biomed Res Int 2017:8539747","journal-title":"Biomed Res Int"},{"key":"10107_CR13","doi-asserted-by":"publisher","DOI":"10.1007\/s10633-018-9652-z","author":"AE Hobby","year":"2018","unstructured":"Hobby AE, Kozareva D, Yonova-Doing E, Hossain IT, Katta M, Huntjens B et al (2018) Effect of varying skin surface electrode position on electroretinogram responses recorded using a handheld stimulating and recording system. Doc Ophthalmol. https:\/\/doi.org\/10.1007\/s10633-018-9652-z","journal-title":"Doc Ophthalmol"},{"key":"10107_CR14","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1007\/BF02580858","volume":"94","author":"DL McCulloch","year":"1997","unstructured":"McCulloch DL, Van Boemel GB, Borchert MS (1997) Comparisons of contact lens, foil, fiber and skin electrodes for patterns electroretinograms. Doc Ophthalmol 94:327\u2013340","journal-title":"Doc Ophthalmol"},{"key":"10107_CR15","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1007\/s10633-017-9600-3","volume":"135","author":"J Woo","year":"2017","unstructured":"Woo J, Jung S, Gauvin M, Lachapelle P (2017) The DTL ERG electrode comes in different shapes and sizes: are they all good? Doc Ophthalmol 135:155\u2013164","journal-title":"Doc Ophthalmol"},{"key":"10107_CR16","doi-asserted-by":"publisher","first-page":"1141","DOI":"10.1007\/s10439-009-9680-7","volume":"37","author":"JP van Dijk","year":"2009","unstructured":"van Dijk JP, Lowery MM, Lapatki BG, Stegeman DF (2009) Evidence of potential averaging over the finite surface of a bioelectric surface electrode. Ann Biomed Eng 37:1141\u20131151","journal-title":"Ann Biomed Eng"},{"key":"10107_CR17","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/0168-5597(89)90046-4","volume":"74","author":"CB Tan","year":"1989","unstructured":"Tan CB, King PJ, Chiappa KH (1989) Pattern ERG: effects of reference electrode site, stimulus mode and check size. Electroencephalogr Clin Neurophysiol 74:11\u201318","journal-title":"Electroencephalogr Clin Neurophysiol"}],"container-title":["Documenta Ophthalmologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10633-026-10107-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10633-026-10107-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10633-026-10107-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T02:32:37Z","timestamp":1787711557000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10633-026-10107-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,8]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["10107"],"URL":"https:\/\/doi.org\/10.1007\/s10633-026-10107-9","relation":{},"ISSN":["0012-4486","1573-2622"],"issn-type":[{"value":"0012-4486","type":"print"},{"value":"1573-2622","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,8]]},"assertion":[{"value":"17 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Daphne McCulloch is the Editor-in-Chief of\n                      Documenta Ophthalmologica\n                      but had no involvement in the peer-review process of this article. Mineo Kondo is an Associate Editor of\n                      Documenta Ophthalmologica\n                      but had no involvement in the peer-review process of this article. The other authors declare that they have no competing interests.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedure performed in study involving human participants were in accordance with the ethical standards of institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":2,"name":"Ethics","label":"Statement of human rights","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"No animal were used in this study.","order":3,"name":"Ethics","label":"Statement on the welfare of animals","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Written informed consent was obtained from all 11 participants before enrollment in the study. In addition, written informed consent for publication of the photograph in Fig.\u00a0\n                      \n                      was obtained from the subject who served as the model.","order":4,"name":"Ethics","label":"Informed consent","group":{"name":"EthicsHeading","label":"Declarations"}}]}}