{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T21:51:40Z","timestamp":1762033900394,"version":"3.37.3"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2022,1,16]],"date-time":"2022-01-16T00:00:00Z","timestamp":1642291200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,1,16]],"date-time":"2022-01-16T00:00:00Z","timestamp":1642291200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Heart Fail Rev"],"published-print":{"date-parts":[[2022,3]]},"DOI":"10.1007\/s10741-021-10201-x","type":"journal-article","created":{"date-parts":[[2022,1,16]],"date-time":"2022-01-16T00:03:06Z","timestamp":1642291386000},"page":"393-398","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Stroke epidemiology and outcomes in the modern era of left ventricular assist devices"],"prefix":"10.1007","volume":"27","author":[{"given":"Chinwe","family":"Ibeh","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kara R.","family":"Melmed","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Melana","family":"Yuzefpolskaya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paolo C.","family":"Colombo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5180-2044","authenticated-orcid":false,"given":"Joshua Z.","family":"Willey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,1,16]]},"reference":[{"issue":"20","key":"10201_CR1","doi-asserted-by":"publisher","first-page":"1435","DOI":"10.1056\/NEJMoa012175","volume":"345","author":"EA Rose","year":"2001","unstructured":"Rose EA, Gelijns AC, Moskowitz AJ et al (2001) Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med 345(20):1435\u20131443","journal-title":"N Engl J Med"},{"issue":"Suppl 15","key":"10201_CR2","doi-asserted-by":"publisher","first-page":"S1785","DOI":"10.21037\/jtd.2018.04.148","volume":"10","author":"A Chatterjee","year":"2018","unstructured":"Chatterjee A, Feldmann C, Dogan G et al (2018) Clinical overview of the HVAD: a centrifugal continuous-flow ventricular assist device with magnetic and hydrodynamic bearings including lateral implantation strategies. J Thorac Dis 10(Suppl 15):S1785\u2013S1789","journal-title":"J Thorac Dis"},{"issue":"9","key":"10201_CR3","doi-asserted-by":"publisher","first-page":"792","DOI":"10.1016\/j.jchf.2018.05.012","volume":"6","author":"CA Milano","year":"2018","unstructured":"Milano CA, Rogers JG, Tatooles AJ et al (2018) HVAD: The ENDURANCE supplemental trial. JACC Heart Fail 6(9):792\u2013802","journal-title":"JACC Heart Fail"},{"issue":"10","key":"10201_CR4","doi-asserted-by":"publisher","first-page":"763","DOI":"10.1161\/CIRCULATIONAHA.121.055716","volume":"144","author":"SM Cho","year":"2021","unstructured":"Cho SM, Mehaffey JH, Meyers SL et al (2021) Cerebrovascular events in patients with centrifugal-flow left ventricular assist devices: propensity score-matched analysis from the Intermacs registry. Circulation 144(10):763\u2013772","journal-title":"Circulation"},{"issue":"7","key":"10201_CR5","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1161\/CIRCULATIONAHA.121.056027","volume":"144","author":"J Stehlik","year":"2021","unstructured":"Stehlik J, Kirklin JK (2021) The long and winding road to an effective left ventricular assist device: the demise of medtronic\u2019s HVAD. Circulation 144(7):509\u2013511","journal-title":"Circulation"},{"issue":"3","key":"10201_CR6","first-page":"215","volume":"326","author":"BM Kuehn","year":"2021","unstructured":"Kuehn BM (2021) FDA: Stop using medtronic\u2019s heartware ventricular assist device. JAMA 326(3):215","journal-title":"JAMA"},{"issue":"17","key":"10201_CR7","doi-asserted-by":"publisher","first-page":"1618","DOI":"10.1056\/NEJMoa1900486","volume":"380","author":"MR Mehra","year":"2019","unstructured":"Mehra MR, Uriel N, Naka Y et al (2019) A fully magnetically levitated left ventricular assist device - final report. N Engl J Med 380(17):1618\u20131627","journal-title":"N Engl J Med"},{"issue":"2","key":"10201_CR8","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1161\/CIRCULATIONAHA.118.037231","volume":"139","author":"PC Colombo","year":"2019","unstructured":"Colombo PC, Mehra MR, Goldstein DJ et al (2019) Comprehensive analysis of stroke in the long-term cohort of the MOMENTUM 3 study. Circulation 139(2):155\u2013168","journal-title":"Circulation"},{"issue":"6","key":"10201_CR9","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1016\/j.healun.2016.12.010","volume":"36","author":"JA Frontera","year":"2017","unstructured":"Frontera JA, Starling R, Cho SM et al (2017) Risk factors, mortality, and timing of ischemic and hemorrhagic stroke with left ventricular assist devices. J Heart Lung Transplant 36(6):673\u2013683","journal-title":"J Heart Lung Transplant"},{"issue":"2","key":"10201_CR10","doi-asserted-by":"publisher","first-page":"535","DOI":"10.1016\/j.athoracsur.2015.02.094","volume":"100","author":"L Harvey","year":"2015","unstructured":"Harvey L, Holley C, Roy SS et al (2015) Stroke after left ventricular assist device implantation: outcomes in the continuous-flow era. Ann Thorac Surg 100(2):535\u2013541","journal-title":"Ann Thorac Surg"},{"doi-asserted-by":"crossref","unstructured":"Kirklin JK, Naftel DC, Myers SL, Pagani FD, Colombo PC (2020) Quantifying the impact from stroke during support with continuous flow ventricular assist devices: An STS INTERMACS analysis. J Heart Lung Transplant","key":"10201_CR11","DOI":"10.1016\/j.healun.2020.04.006"},{"issue":"9","key":"10201_CR12","doi-asserted-by":"publisher","first-page":"881","DOI":"10.1016\/j.healun.2009.05.018","volume":"28","author":"AJ Boyle","year":"2009","unstructured":"Boyle AJ, Russell SD, Teuteberg JJ et al (2009) Low thromboembolism and pump thrombosis with the HeartMate II left ventricular assist device: analysis of outpatient anti-coagulation. J Heart Lung Transplant 28(9):881\u2013887","journal-title":"J Heart Lung Transplant"},{"issue":"4","key":"10201_CR13","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1016\/j.ccl.2018.06.007","volume":"36","author":"A Kadakkal","year":"2018","unstructured":"Kadakkal A, Najjar SS (2018) Neurologic events in continuous-flow left ventricular assist devices. Cardiol Clin 36(4):531\u2013539","journal-title":"Cardiol Clin"},{"doi-asserted-by":"crossref","unstructured":"John R, Naka Y, Park SJ (2014)\u00a0Impact of concurrent surgical valve procedures in patients receiving continuous-flow devices. J Thorac Cardiovasc Surg\u00a0147(2):581\u2013589. discussion 589","key":"10201_CR14","DOI":"10.1016\/j.jtcvs.2013.10.024"},{"issue":"3","key":"10201_CR15","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1097\/MAT.0000000000000074","volume":"60","author":"JA Morgan","year":"2014","unstructured":"Morgan JA, Brewer RJ, Nemeh HW et al (2014) Stroke while on long-term left ventricular assist device support: incidence, outcome, and predictors. ASAIO J 60(3):284\u2013289","journal-title":"ASAIO J"},{"issue":"1","key":"10201_CR16","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1007\/s12028-017-0386-7","volume":"27","author":"SM Cho","year":"2017","unstructured":"Cho SM, Moazami N, Frontera JA (2017) Stroke and Intracranial hemorrhage in HeartMate II and HeartWare left ventricular assist devices: a systematic review. Neurocrit Care 27(1):17\u201325","journal-title":"Neurocrit Care"},{"issue":"2","key":"10201_CR17","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1016\/j.healun.2012.09.013","volume":"32","author":"D Feldman","year":"2013","unstructured":"Feldman D, Pamboukian SV, Teuteberg JJ et al (2013) The 2013 international society for heart and lung transplantation guidelines for mechanical circulatory support: executive summary. J Heart Lung Transplant 32(2):157\u2013187","journal-title":"J Heart Lung Transplant"},{"issue":"9","key":"10201_CR18","doi-asserted-by":"publisher","first-page":"878","DOI":"10.1016\/j.healun.2014.05.005","volume":"33","author":"JZ Willey","year":"2014","unstructured":"Willey JZ, Demmer RT, Takayama H, Colombo PC, Lazar RM (2014) Cerebrovascular disease in the era of left ventricular assist devices with continuous flow: risk factors, diagnosis, and treatment. J Heart Lung Transplant 33(9):878\u2013887","journal-title":"J Heart Lung Transplant"},{"issue":"23","key":"10201_CR19","doi-asserted-by":"publisher","first-page":"2241","DOI":"10.1056\/NEJMoa0909938","volume":"361","author":"MS Slaughter","year":"2009","unstructured":"Slaughter MS, Rogers JG, Milano CA et al (2009) Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 361(23):2241\u20132251","journal-title":"N Engl J Med"},{"issue":"4","key":"10201_CR20","doi-asserted-by":"publisher","first-page":"312","DOI":"10.1016\/j.jacc.2009.03.055","volume":"54","author":"FD Pagani","year":"2009","unstructured":"Pagani FD, Miller LW, Russell SD et al (2009) Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol 54(4):312\u2013321","journal-title":"J Am Coll Cardiol"},{"issue":"7","key":"10201_CR21","doi-asserted-by":"publisher","first-page":"675","DOI":"10.1016\/j.healun.2013.04.004","volume":"32","author":"MS Slaughter","year":"2013","unstructured":"Slaughter MS, Pagani FD, McGee EC et al (2013) HeartWare ventricular assist system for bridge to transplant: combined results of the bridge to transplant and continued access protocol trial. J Heart Lung Transplant 32(7):675\u2013683","journal-title":"J Heart Lung Transplant"},{"issue":"5","key":"10201_CR22","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1056\/NEJMoa1602954","volume":"376","author":"JG Rogers","year":"2017","unstructured":"Rogers JG, Pagani FD, Tatooles AJ et al (2017) Intrapericardial left ventricular assist device for advanced heart failure. N Engl J Med 376(5):451\u2013460","journal-title":"N Engl J Med"},{"issue":"7","key":"10201_CR23","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1016\/j.jchf.2017.02.016","volume":"5","author":"RC Starling","year":"2017","unstructured":"Starling RC, Estep JD, Horstmanshof DA et al (2017) Risk assessment and comparative effectiveness of left ventricular assist device and medical management in ambulatory heart failure patients: the ROADMAP study 2-year results. JACC Heart Fail 5(7):518\u2013527","journal-title":"JACC Heart Fail"},{"issue":"4","key":"10201_CR24","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1016\/j.healun.2014.09.042","volume":"34","author":"ME Nassif","year":"2015","unstructured":"Nassif ME, Tibrewala A, Raymer DS et al (2015) Systolic blood pressure on discharge after left ventricular assist device insertion is associated with subsequent stroke. J Heart Lung Transplant 34(4):503\u2013508","journal-title":"J Heart Lung Transplant"},{"issue":"4","key":"10201_CR25","doi-asserted-by":"publisher","first-page":"396","DOI":"10.1016\/j.healun.2018.11.003","volume":"38","author":"A Pinsino","year":"2019","unstructured":"Pinsino A, Castagna F, Zuver AM et al (2019) Prognostic implications of serial outpatient blood pressure measurements in patients with an axial continuous-flow left ventricular assist device. J Heart Lung Transplant 38(4):396\u2013405","journal-title":"J Heart Lung Transplant"},{"issue":"5","key":"10201_CR26","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1016\/j.healun.2019.11.016","volume":"39","author":"JA Cowger","year":"2020","unstructured":"Cowger JA, Shah P, Pagani FD et al (2020) Outcomes based on blood pressure in patients on continuous flow left ventricular assist device support: an Interagency Registry for Mechanically Assisted Circulatory Support analysis. J Heart Lung Transplant 39(5):441\u2013453","journal-title":"J Heart Lung Transplant"},{"issue":"10","key":"10201_CR27","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1016\/j.jchf.2017.06.014","volume":"5","author":"D Acharya","year":"2017","unstructured":"Acharya D, Loyaga-Rendon R, Morgan CJ et al (2017) INTERMACS Analysis of stroke during support with continuous-flow left ventricular assist devices: risk factors and outcomes. JACC Heart Fail 5(10):703\u2013711","journal-title":"JACC Heart Fail"},{"issue":"5","key":"10201_CR28","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1097\/MAT.0b013e318260c6a6","volume":"58","author":"A Aggarwal","year":"2012","unstructured":"Aggarwal A, Gupta A, Kumar S et al (2012) Are blood stream infections associated with an increased risk of hemorrhagic stroke in patients with a left ventricular assist device? ASAIO J 58(5):509\u2013513","journal-title":"ASAIO J"},{"issue":"1","key":"10201_CR29","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1007\/s12028-018-0662-1","volume":"31","author":"SM Cho","year":"2019","unstructured":"Cho SM, Moazami N, Katz S, Bhimraj A, Shrestha NK, Frontera JA (2019) Stroke risk following infection in patients with continuous-flow left ventricular assist device. Neurocrit Care 31(1):72\u201380","journal-title":"Neurocrit Care"},{"issue":"2","key":"10201_CR30","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1007\/s11906-015-0618-1","volume":"18","author":"JZ Willey","year":"2016","unstructured":"Willey JZ, Boehme AK, Castagna F et al (2016) Hypertension and stroke in patients with left ventricular assist devices (LVADs). Curr Hypertens Rep 18(2):12","journal-title":"Curr Hypertens Rep"},{"issue":"12","key":"10201_CR31","doi-asserted-by":"publisher","first-page":"909","DOI":"10.1080\/14779072.2018.1540300","volume":"16","author":"K Goodwin","year":"2018","unstructured":"Goodwin K, Kluis A, Alexy T, John R, Voeller R (2018) Neurological complications associated with left ventricular assist device therapy. Expert Rev Cardiovasc Ther 16(12):909\u2013917","journal-title":"Expert Rev Cardiovasc Ther"},{"issue":"10","key":"10201_CR32","doi-asserted-by":"publisher","first-page":"1080","DOI":"10.1016\/j.healun.2017.07.005","volume":"36","author":"JK Kirklin","year":"2017","unstructured":"Kirklin JK, Pagani FD, Kormos RL et al (2017) Eighth annual INTERMACS report: special focus on framing the impact of adverse events. J Heart Lung Transplant 36(10):1080\u20131086","journal-title":"J Heart Lung Transplant"},{"issue":"1","key":"10201_CR33","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.healun.2016.10.001","volume":"36","author":"S Maltais","year":"2017","unstructured":"Maltais S, Kilic A, Nathan S et al (2017) PREVENtion of HeartMate II Pump thrombosis through clinical management: the PREVENT multi-center study. J Heart Lung Transplant 36(1):1\u201312","journal-title":"J Heart Lung Transplant"},{"doi-asserted-by":"crossref","unstructured":"Xanthopoulos A, Tryposkiadis K, Triposkiadis F (2020)\u00a0 Postimplant phosphodiesterase type 5 inhibitors use is associated with lower rates of thrombotic events after left ventricular assist device implantation. J Am Heart Assoc\u00a09(14):e015897","key":"10201_CR34","DOI":"10.1161\/JAHA.119.015897"},{"doi-asserted-by":"crossref","unstructured":"Gulati G, Grandin EW, Kennedy K (2019)\u00a0 Preimplant phosphodiesterase-5 inhibitor use is associated with higher rates of severe early right heart failure after left ventricular assist device implantation. Circ Heart Fail\u00a012(6):e005537","key":"10201_CR35","DOI":"10.1161\/CIRCHEARTFAILURE.118.005537"},{"doi-asserted-by":"crossref","unstructured":"Willey JZ, Gavalas MV, Trinh PN (2016) Outcomes after stroke complicating left ventricular assist device. J Heart Lung Transplant\u00a0","key":"10201_CR36","DOI":"10.1016\/j.healun.2016.03.014"}],"container-title":["Heart Failure Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10741-021-10201-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10741-021-10201-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10741-021-10201-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,5]],"date-time":"2022-03-05T06:30:49Z","timestamp":1646461849000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10741-021-10201-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,16]]},"references-count":36,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022,3]]}},"alternative-id":["10201"],"URL":"https:\/\/doi.org\/10.1007\/s10741-021-10201-x","relation":{},"ISSN":["1382-4147","1573-7322"],"issn-type":[{"type":"print","value":"1382-4147"},{"type":"electronic","value":"1573-7322"}],"subject":[],"published":{"date-parts":[[2022,1,16]]},"assertion":[{"value":"1 December 2021","order":1,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 January 2022","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}