{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T00:30:50Z","timestamp":1788827450361,"version":"build-2803163510"},"reference-count":46,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2024,12,27]],"date-time":"2024-12-27T00:00:00Z","timestamp":1735257600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,12,27]],"date-time":"2024-12-27T00:00:00Z","timestamp":1735257600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Heart Fail Rev"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Left ventricular assist devices (LVAD) have improved mortality and quality of life for patients with end-stage heart failure by providing an alternative to cardiac transplant or as a bridge to transplantation. The improvement in functional capacity however is minimal to modest depending on the right ventricular function, optimal hemodynamics on LVAD therapy, and comorbidities. There is improvement in submaximal exercise capacity but improvement in peak aerobic capacity is limited. Exercise capacity can be improved by referral to cardiac rehabilitation after LVAD implantation. Cardiac rehabilitation is safe and effective with improvement in functional capacity, and decrease in mortality and heart failure hospitalizations. Cardiopulmonary exercise testing (CPET) is a specialized exercise stress test that measures gas exchange during exercise to determine a variety of variables that have been shown to be predictive of mortality in patients undergoing cardiac transplant. CPET is valuable for prognostication and is a predictor of adverse outcomes, including right heart failure in the immediate post-LVAD implantation period, long-term mortality. CPET is an additional testing that can aid in the decision making for LVAD explantation or decommissioning.<\/jats:p>","DOI":"10.1007\/s10741-024-10477-9","type":"journal-article","created":{"date-parts":[[2024,12,26]],"date-time":"2024-12-26T21:43:27Z","timestamp":1735249407000},"page":"469-476","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Exercise and cardiac rehabilitation after LVAD implantation"],"prefix":"10.1007","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-9941-2556","authenticated-orcid":false,"given":"Emily","family":"Newman","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yevgeniy","family":"Brailovsky","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Indranee","family":"Rajapreyar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,12,27]]},"reference":[{"issue":"3","key":"10477_CR1","doi-asserted-by":"publisher","first-page":"778","DOI":"10.1016\/j.athoracsur.2020.12.038","volume":"111","author":"EJ Molina","year":"2021","unstructured":"Molina EJ, Shah P, Kiernan MS et al (2021) The Society of Thoracic Surgeons Intermacs 2020 Annual Report. Ann Thorac Surg 111(3):778\u2013792","journal-title":"Ann Thorac Surg"},{"key":"10477_CR2","doi-asserted-by":"publisher","DOI":"10.15420\/cfr.2020.15","volume":"6","author":"KK Mirza","year":"2020","unstructured":"Mirza KK, Gustafsson F (2020) Determinants of functional capacity and quality of life after implantation of a durable left ventricular assist device. Card Fail Rev 6:e29","journal-title":"Card Fail Rev"},{"issue":"8","key":"10477_CR3","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1016\/j.jchf.2016.03.022","volume":"4","author":"R Malhotra","year":"2016","unstructured":"Malhotra R, Bakken K, D\u2019Elia E, Lewis GD (2016) Cardiopulmonary exercise testing in heart failure. JACC Heart Fail 4(8):607\u2013616","journal-title":"JACC Heart Fail"},{"issue":"3","key":"10477_CR4","doi-asserted-by":"publisher","first-page":"778","DOI":"10.1161\/01.CIR.83.3.778","volume":"83","author":"DM Mancini","year":"1991","unstructured":"Mancini DM, Eisen H, Kussmaul W, Mull R, Edmunds LH Jr, Wilson JR (1991) Value of peak exercise oxygen consumption for optimal timing of cardiac transplantation in ambulatory patients with heart failure. Circulation 83(3):778\u2013786","journal-title":"Circulation"},{"issue":"11","key":"10477_CR5","doi-asserted-by":"publisher","first-page":"1350","DOI":"10.1016\/j.amjcard.2003.08.027","volume":"92","author":"LH Lund","year":"2003","unstructured":"Lund LH, Aaronson KD, Mancini DM (2003) Predicting survival in ambulatory patients with severe heart failure on beta-blocker therapy. Am J Cardiol 92(11):1350\u20131354","journal-title":"Am J Cardiol"},{"issue":"1","key":"10477_CR6","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1016\/S1053-2498(02)00473-4","volume":"22","author":"LR Peterson","year":"2003","unstructured":"Peterson LR, Schechtman KB, Ewald GA et al (2003) The effect of beta-adrenergic blockers on the prognostic value of peak exercise oxygen uptake in patients with heart failure. J Heart Lung Transplant 22(1):70\u201377","journal-title":"J Heart Lung Transplant"},{"issue":"10","key":"10477_CR7","doi-asserted-by":"publisher","first-page":"1134","DOI":"10.1097\/MAT.0000000000001383","volume":"67","author":"JW Christle","year":"2021","unstructured":"Christle JW, Moneghetti KJ, Duclos S et al (2021) Cardiopulmonary exercise testing with echocardiography to assess recovery in patients with ventricular assist devices. ASAIO J 67(10):1134\u20131138","journal-title":"ASAIO J"},{"issue":"8","key":"10477_CR8","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1016\/j.healun.2014.12.006","volume":"34","author":"RY Loyaga-Rendon","year":"2015","unstructured":"Loyaga-Rendon RY, Plaisance EP, Arena R, Shah K (2015) Exercise physiology, testing, and training in patients supported by a left ventricular assist device. J Heart Lung Transplant 34(8):1005\u20131016","journal-title":"J Heart Lung Transplant"},{"issue":"3","key":"10477_CR9","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1111\/aor.13349","volume":"43","author":"C Gross","year":"2019","unstructured":"Gross C, Marko C, Mikl J et al (2019) LVAD pump flow does not adequately increase with exercise. Artif Organs 43(3):222\u2013228","journal-title":"Artif Organs"},{"issue":"6","key":"10477_CR10","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1093\/eurjhf\/hfs042","volume":"14","author":"MR Noor","year":"2012","unstructured":"Noor MR, Bowles C, Banner NR (2012) Relationship between pump speed and exercise capacity during HeartMate II left ventricular assist device support: influence of residual left ventricular function. Eur J Heart Fail 14(6):613\u2013620","journal-title":"Eur J Heart Fail"},{"issue":"4","key":"10477_CR11","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1002\/ejhf.52","volume":"16","author":"MH Jung","year":"2014","unstructured":"Jung MH, Hansen PB, Sander K et al (2014) Effect of increasing pump speed during exercise on peak oxygen uptake in heart failure patients supported with a continuous-flow left ventricular assist device. A double-blind randomized study. Eur J Heart Fail. 16(4):403\u20138","journal-title":"Eur J Heart Fail."},{"issue":"5","key":"10477_CR12","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1097\/MAT.0000000000000693","volume":"64","author":"AN Rosenbaum","year":"2018","unstructured":"Rosenbaum AN, Dunlay SM, Pereira NL et al (2018) Determinants of improvement in cardiopulmonary exercise testing after left ventricular assist device implantation. ASAIO J 64(5):610\u2013615","journal-title":"ASAIO J"},{"key":"10477_CR13","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1186\/1749-8090-9-93","volume":"9","author":"D Camboni","year":"2014","unstructured":"Camboni D, Lange TJ, Ganslmeier P et al (2014) Left ventricular support adjustment to aortic valve opening with analysis of exercise capacity. J Cardiothorac Surg 9:93","journal-title":"J Cardiothorac Surg"},{"issue":"4","key":"10477_CR14","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1016\/j.jchf.2019.10.013","volume":"8","author":"N Moss","year":"2020","unstructured":"Moss N, Rakita V, Lala A et al (2020) Hemodynamic response to exercise in patients supported by continuous flow left ventricular assist devices. JACC Heart Fail 8(4):291\u2013301","journal-title":"JACC Heart Fail"},{"issue":"1","key":"10477_CR15","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/j.cardfail.2021.07.012","volume":"28","author":"S Hsu","year":"2022","unstructured":"Hsu S, Fang JC, Borlaug BA (2022) Hemodynamics for the heart failure clinician: a state-of-the-art review. J Card Fail 28(1):133\u2013148","journal-title":"J Card Fail"},{"issue":"2","key":"10477_CR16","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1016\/j.healun.2020.11.009","volume":"40","author":"T Tran","year":"2021","unstructured":"Tran T, Muralidhar A, Hunter K et al (2021) Right ventricular function and cardiopulmonary performance among patients with heart failure supported by durable mechanical circulatory support devices. J Heart Lung Transplant 40(2):128\u2013137","journal-title":"J Heart Lung Transplant"},{"issue":"4","key":"10477_CR17","doi-asserted-by":"publisher","first-page":"408","DOI":"10.1097\/MAT.0000000000000569","volume":"63","author":"C Marko","year":"2017","unstructured":"Marko C, Xhelili E, Lackner T, Zimpfer D, Schima H, Moscato F (2017) Exercise performance during the first two years after left ventricular assist device implantation. ASAIO J 63(4):408\u2013413","journal-title":"ASAIO J"},{"issue":"8","key":"10477_CR18","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1016\/j.cardfail.2014.05.008","volume":"20","author":"SM Dunlay","year":"2014","unstructured":"Dunlay SM, Allison TG, Pereira NL (2014) Changes in cardiopulmonary exercise testing parameters following continuous flow left ventricular assist device implantation and heart transplantation. J Card Fail 20(8):548\u2013554","journal-title":"J Card Fail"},{"issue":"1","key":"10477_CR19","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1111\/aor.12936","volume":"42","author":"T Schmidt","year":"2018","unstructured":"Schmidt T, Bjarnason-Wehrens B, Bartsch P et al (2018) Exercise capacity and functional performance in heart failure patients supported by a left ventricular assist device at discharge from inpatient rehabilitation. Artif Organs 42(1):22\u201330","journal-title":"Artif Organs"},{"issue":"5","key":"10477_CR20","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1111\/aor.12172","volume":"38","author":"L Compostella","year":"2014","unstructured":"Compostella L, Russo N, Setzu T, Compostella C, Bellotto F (2014) Exercise performance of chronic heart failure patients in the early period of support by an axial-flow left ventricular assist device as destination therapy. Artif Organs 38(5):366\u2013373","journal-title":"Artif Organs"},{"issue":"3","key":"10477_CR21","doi-asserted-by":"publisher","first-page":"1796","DOI":"10.1002\/ehf2.13234","volume":"8","author":"SEA Felix","year":"2021","unstructured":"Felix SEA, Oerlemans MIF, Ramjankhan FZ et al (2021) One year improvement of exercise capacity in patients with mechanical circulatory support as bridge to transplantation. ESC Heart Fail 8(3):1796\u20131805","journal-title":"ESC Heart Fail"},{"issue":"7","key":"10477_CR22","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0235684","volume":"15","author":"L Fresiello","year":"2020","unstructured":"Fresiello L, Jacobs S, Timmermans P et al (2020) Limiting factors of peak and submaximal exercise capacity in LVAD patients. PLoS ONE 15(7):e0235684","journal-title":"PLoS ONE"},{"issue":"15","key":"10477_CR23","doi-asserted-by":"publisher","first-page":"1386","DOI":"10.1056\/NEJMoa1800866","volume":"378","author":"MR Mehra","year":"2018","unstructured":"Mehra MR, Goldstein DJ, Uriel N et al (2018) Two-year outcomes with a magnetically levitated cardiac pump in heart failure. N Engl J Med 378(15):1386\u20131395","journal-title":"N Engl J Med"},{"issue":"4","key":"10477_CR24","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1007\/s10047-021-01261-9","volume":"24","author":"J Grinstein","year":"2021","unstructured":"Grinstein J, Sawalha Y, Medvedofsky DA et al (2021) VE\/VCO2 slope predicts RV dysfunction and mortality after left ventricular assist device: a fresh look at cardiopulmonary stress testing for prognostication. J Artif Organs 24(4):425\u2013432","journal-title":"J Artif Organs"},{"key":"10477_CR25","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/j.ijchv.2014.07.004","volume":"4","author":"A Mezzani","year":"2014","unstructured":"Mezzani A, Pistono M, Corra U et al (2014) Systemic perfusion at peak incremental exercise in left ventricular assist device recipients: partitioning pumo and native lef ventricle relative contribution. IJC Heart Vessels 4:40\u201345","journal-title":"IJC Heart Vessels"},{"issue":"6","key":"10477_CR26","doi-asserted-by":"publisher","first-page":"808","DOI":"10.1097\/MAT.0000000000001571","volume":"68","author":"A Dorken Gallastegi","year":"2022","unstructured":"Dorken Gallastegi A, Ergi GD, Kahraman U et al (2022) Prognostic value of cardiopulmonary exercise test parameters in ventricular assist device therapy. ASAIO J 68(6):808\u2013813","journal-title":"ASAIO J"},{"issue":"5","key":"10477_CR27","doi-asserted-by":"publisher","first-page":"3496","DOI":"10.1002\/ehf2.14099","volume":"9","author":"V Maharaj","year":"2022","unstructured":"Maharaj V, Agdamag AC, Duval S et al (2022) Hypotension on cardiopulmonary stress test predicts 90 day mortality after LVAD implantation in INTERMACS 3\u20136 patients. ESC Heart Fail 9(5):3496\u20133504","journal-title":"ESC Heart Fail"},{"key":"10477_CR28","doi-asserted-by":"publisher","unstructured":"Mirza KK, Szymanski MK, Schmidt T, de Jonge N, Brahmbhatt DH, Billia F, Hsu S, MacGowan GA, Jakovljevic DG, Agostoni P, Trombara F, Jorde U, Rochlani Y, Vandersmissen K, Reiss N, Russell SD, Meyns B, Gustafsson F (2021) PRO-VAD Investigators. Prognostic value of peak oxygen uptake in patients supported with left ventricular assist devices (PRO-VAD). JACC Heart Fail 9(10):758\u2013767. https:\/\/doi.org\/10.1016\/j.jchf.2021.05.021. Epub 2021 Aug 11. Erratum in: JACC Heart Fail. 2021 Dec;9(12):944. https:\/\/doi.org\/10.1016\/j.jchf.2021.10.004. PMID: 34391745.","DOI":"10.1016\/j.jchf.2021.05.021 10.1016\/j.jchf.2021.10.004"},{"issue":"1","key":"10477_CR29","doi-asserted-by":"publisher","first-page":"e003694","DOI":"10.1161\/CIRCHEARTFAILURE.116.003694","volume":"10","author":"J Steiner","year":"2017","unstructured":"Steiner J, Wiafe S, Camuso J et al (2017) Predicting success: left ventricular assist device explantation evaluation protocol using comprehensive cardiopulmonary exercise testing. Circ Heart Fail 10(1):e003694","journal-title":"Circ Heart Fail"},{"issue":"18","key":"10477_CR30","doi-asserted-by":"publisher","first-page":"1873","DOI":"10.1056\/NEJMoa053063","volume":"355","author":"EJ Birks","year":"2006","unstructured":"Birks EJ, Tansley PD, Hardy J et al (2006) Left ventricular assist device and drug therapy for the reversal of heart failure. N Engl J Med 355(18):1873\u20131884","journal-title":"N Engl J Med"},{"issue":"2","key":"10477_CR31","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1253\/circj.CJ-15-1030","volume":"80","author":"D Nitta","year":"2016","unstructured":"Nitta D, Kinugawa K, Imamura T et al (2016) Novel scoring system to predict ineligibility for bridge to implantable left ventricular assist device as destination therapy before extracorporeal ventricular assist device implantation - for the coming era of destination therapy in Japan. Circ J 80(2):387\u2013394","journal-title":"Circ J"},{"issue":"2","key":"10477_CR32","first-page":"130","volume":"33","author":"CS Perme","year":"2006","unstructured":"Perme CS, Southard RE, Joyce DL, Noon GP, Loebe M (2006) Early mobilization of LVAD recipients who require prolonged mechanical ventilation. Tex Heart Inst J 33(2):130\u2013133","journal-title":"Tex Heart Inst J"},{"issue":"2","key":"10477_CR33","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1097\/01823246-201324020-00006","volume":"24","author":"R Scheiderer","year":"2013","unstructured":"Scheiderer R, Belden C, Schwab D, Haney C, Paz J (2013) Exercise guidelines for inpatients following ventricular assist device placement: a systematic review of the literature. Cardiopulm Phys Ther J 24(2):35\u201342","journal-title":"Cardiopulm Phys Ther J"},{"issue":"10","key":"10477_CR34","doi-asserted-by":"publisher","first-page":"860","DOI":"10.1097\/PHM.0000000000000101","volume":"93","author":"O Alsara","year":"2014","unstructured":"Alsara O, Reeves RK, Pyfferoen MD et al (2014) Inpatient rehabilitation outcomes for patients receiving left ventricular assist device. Am J Phys Med Rehabil 93(10):860\u2013868","journal-title":"Am J Phys Med Rehabil"},{"issue":"1","key":"10477_CR35","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/j.pmrj.2016.05.013","volume":"9","author":"G Yost","year":"2017","unstructured":"Yost G, Coyle L, Milkevitch K, Adair R, Tatooles A, Bhat G (2017) Efficacy of inpatient rehabilitation after left ventricular assist device implantation. PM R 9(1):40\u201345","journal-title":"PM R"},{"issue":"2","key":"10477_CR36","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.pmrj.2012.12.003","volume":"5","author":"E Nguyen","year":"2013","unstructured":"Nguyen E, Stein J (2013) Functional outcomes of adults with left ventricular assist devices receiving inpatient rehabilitation. PM R 5(2):99\u2013103","journal-title":"PM R"},{"issue":"6","key":"10477_CR37","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1002\/rnj.192","volume":"40","author":"G Forrest","year":"2015","unstructured":"Forrest G, Radu G, Rifenburg K, Shields E, Clift S (2015) Left ventricular assist device: care on inpatient rehabilitation facility. Rehabil Nurs 40(6):378\u2013383","journal-title":"Rehabil Nurs"},{"issue":"11","key":"10477_CR38","doi-asserted-by":"publisher","first-page":"1008","DOI":"10.1016\/j.pmrj.2014.05.004","volume":"6","author":"SK Chu","year":"2014","unstructured":"Chu SK, McCormick Z, Hwang S, Sliwa JA, Rydberg L (2014) Outcomes of acute inpatient rehabilitation of patients with left ventricular assist devices. PM R 6(11):1008\u20131012","journal-title":"PM R"},{"issue":"11","key":"10477_CR39","doi-asserted-by":"publisher","first-page":"1378","DOI":"10.1177\/2047487314558772","volume":"22","author":"C Marko","year":"2015","unstructured":"Marko C, Danzinger G, Kaferback M et al (2015) Safety and efficacy of cardiac rehabilitation for patients with continuous flow left ventricular assist devices. Eur J Prev Cardiol 22(11):1378\u20131384","journal-title":"Eur J Prev Cardiol"},{"issue":"3","key":"10477_CR40","first-page":"304","volume":"69","author":"A Shaaban","year":"2023","unstructured":"Shaaban A, Schultz J, Leonard J et al (2023) Outcomes of patients referred for cardiac rehabilitation after left ventricular assist device implantation. ASAIO J 69(3):304\u2013308","journal-title":"ASAIO J"},{"key":"10477_CR41","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2021.709898","volume":"8","author":"A Passantino","year":"2021","unstructured":"Passantino A, Dalla Vecchia LA, Corra U et al (2021) The future of exercise-based cardiac rehabilitation for patients with heart failure. Front Cardiovasc Med 8:709898","journal-title":"Front Cardiovasc Med"},{"issue":"6","key":"10477_CR42","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1016\/j.jchf.2014.06.011","volume":"2","author":"DJ Kerrigan","year":"2014","unstructured":"Kerrigan DJ, Williams CT, Ehrman JK et al (2014) Cardiac rehabilitation improves functional capacity and patient-reported health status in patients with continuous-flow left ventricular assist devices: the Rehab-VAD randomized controlled trial. JACC Heart Fail 2(6):653\u2013659","journal-title":"JACC Heart Fail"},{"issue":"5","key":"10477_CR43","doi-asserted-by":"publisher","first-page":"1245","DOI":"10.1016\/S0735-1097(00)00531-3","volume":"35","author":"CP Green","year":"2000","unstructured":"Green CP, Porter CB, Bresnahan DR, Spertus JA (2000) Development and evaluation of the Kansas City Cardiomyopathy Questionnaire: a new health status measure for heart failure. J Am Coll Cardiol 35(5):1245\u20131255","journal-title":"J Am Coll Cardiol"},{"issue":"4","key":"10477_CR44","doi-asserted-by":"publisher","first-page":"1017","DOI":"10.1016\/0002-8703(92)90986-6","volume":"124","author":"TS Rector","year":"1992","unstructured":"Rector TS, Cohn JN (1992) Assessment of patient outcome with the Minnesota Living with Heart Failure questionnaire: reliability and validity during a randomized, double-blind, placebo-controlled trial of pimobendan. Pimobendan Multicenter Research Group. Am Heart J 124(4):1017\u201325","journal-title":"Am Heart J"},{"issue":"8","key":"10477_CR45","doi-asserted-by":"publisher","first-page":"e002800","DOI":"10.1161\/CIRCHEARTFAILURE.115.002800","volume":"9","author":"SV Arnold","year":"2016","unstructured":"Arnold SV, Jones PG, Allen LA et al (2016) Frequency of poor outcome (death or poor quality of life) after left ventricular assist device for destination therapy: results from the INTERMACS Registry. Circ Heart Fail 9(8):e002800","journal-title":"Circ Heart Fail"},{"issue":"8","key":"10477_CR46","doi-asserted-by":"publisher","first-page":"e003380","DOI":"10.1161\/CIRCHEARTFAILURE.116.003380","volume":"9","author":"GC Stewart","year":"2016","unstructured":"Stewart GC (2016) Putting life in the years: incorporating quality of life into left ventricular assist devices outcomes. Circ Heart Fail 9(8):e003380","journal-title":"Circ Heart Fail"}],"container-title":["Heart Failure Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10741-024-10477-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10741-024-10477-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10741-024-10477-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,11]],"date-time":"2025-04-11T05:20:50Z","timestamp":1744348850000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10741-024-10477-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,27]]},"references-count":46,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2025,5]]}},"alternative-id":["10477"],"URL":"https:\/\/doi.org\/10.1007\/s10741-024-10477-9","relation":{},"ISSN":["1573-7322"],"issn-type":[{"value":"1573-7322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,27]]},"assertion":[{"value":"16 December 2024","order":1,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 December 2024","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Author Yevgeniy Brailovsky is an Associate Editor of the journal. Drs. Newman, Brailovsky, and Rajapreyar have no conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}