{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T00:08:35Z","timestamp":1776730115001,"version":"3.51.2"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2017,4,25]],"date-time":"2017-04-25T00:00:00Z","timestamp":1493078400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int Ophthalmol"],"published-print":{"date-parts":[[2018,4]]},"DOI":"10.1007\/s10792-017-0519-1","type":"journal-article","created":{"date-parts":[[2017,4,25]],"date-time":"2017-04-25T03:25:05Z","timestamp":1493090705000},"page":"697-703","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["IOP measurement in silicone oil tamponade eyes by Corvis ST tonometer, Goldmann applanation tonometry and non-contact tonometry"],"prefix":"10.1007","volume":"38","author":[{"given":"Yang","family":"Zhang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lin","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ailing","family":"Bian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qi","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2017,4,25]]},"reference":[{"key":"519_CR1","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1007\/s10792-013-9830-7","volume":"34","author":"MY Teke","year":"2014","unstructured":"Teke MY, Elgin U, Sen E et al (2014) Intravitreal silicone oil induced changes in corneal biomechanics. Int Ophthalmol 34:457\u2013463","journal-title":"Int Ophthalmol"},{"key":"519_CR2","doi-asserted-by":"crossref","first-page":"1410","DOI":"10.1136\/bjophthalmol-2013-303400","volume":"97","author":"L Reznicek","year":"2013","unstructured":"Reznicek L, Muth D, Kampik A et al (2013) Evaluation of a novel Scheimpflug-based non-contact tonometer in healthy subjects and patients with ocular hypertension and glaucoma. Br J Ophthalmol 97:1410\u20131414","journal-title":"Br J Ophthalmol"},{"key":"519_CR3","doi-asserted-by":"crossref","first-page":"558","DOI":"10.3928\/1081597X-20130719-06","volume":"29","author":"G Nemeth","year":"2013","unstructured":"Nemeth G, Hassan Z, Csutak A et al (2013) Repeatability of ocular biomechanical data measurements with a Scheimpflug-based noncontact device on normal corneas. J Refract Surg 29:558\u2013563","journal-title":"J Refract Surg"},{"key":"519_CR4","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.1016\/S0161-6420(92)31836-6","volume":"99","author":"AW Eller","year":"1992","unstructured":"Eller AW, Gardner TW, D\u2019Antonio JA (1992) Survey of intraocular silicone oil use in the United States. Ophthalmology 99:1174\u20131176","journal-title":"Ophthalmology"},{"key":"519_CR5","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.1097\/IAE.0b013e3182327cf9","volume":"32","author":"R Narayanan","year":"2012","unstructured":"Narayanan R, Tibra N, Mathai A et al (2012) Sutureless 23-gauge versus 20-gauge vitrectomy with silicone oil injection in rhegmatogenous retinal detachment. Retina 32:1013\u20131016","journal-title":"Retina"},{"key":"519_CR6","doi-asserted-by":"crossref","first-page":"1585","DOI":"10.1007\/s00417-009-1155-x","volume":"247","author":"P Ichhpujani","year":"2009","unstructured":"Ichhpujani P, Jindal A, Jay Katz L (2009) Silicone oil induced glaucoma: a review. Graefes Arch Clin Exp Ophthalmol 247:1585\u20131593","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"519_CR7","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/S0039-6257(00)00110-7","volume":"44","author":"MJ Doughty","year":"2000","unstructured":"Doughty MJ, Zaman ML (2000) Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 44:367\u2013408","journal-title":"Surv Ophthalmol"},{"key":"519_CR8","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1097\/01.ijg.0000176940.81799.33","volume":"14","author":"P Gunvant","year":"2005","unstructured":"Gunvant P, O\u2019Leary DJ, Baskaran M et al (2005) Evaluation of tonometric correction factors. J Glaucoma 14:337\u2013343","journal-title":"J Glaucoma"},{"key":"519_CR9","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1007\/s00347-008-1690-6","volume":"105","author":"B Schroeder","year":"2008","unstructured":"Schroeder B, Hager A, Kutschan A et al (2008) Measurement of viscoelastic corneal parameters (corneal hysteresis) in patients with primary open angle glaucoma. Ophthalmologe 105:916\u2013920","journal-title":"Ophthalmologe"},{"issue":"840\u2013849","key":"519_CR10","first-page":"e2","volume":"153","author":"S Kaushik","year":"2012","unstructured":"Kaushik S, Pandav SS, Banger A et al (2012) Relationship between corneal biomechanical properties, central corneal thickness, and intraocular pressure across the spectrum of glaucoma. Am J Ophthalmol 153(840\u2013849):e2","journal-title":"Am J Ophthalmol"},{"key":"519_CR11","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1097\/OPX.0000000000000575","volume":"92","author":"J Hong","year":"2015","unstructured":"Hong J, Yu Z, Jiang C et al (2015) Corvis ST Tonometer for measuring postoperative IOP in LASIK patients. Optom Vis Sci 92:589\u2013595","journal-title":"Optom Vis Sci"},{"key":"519_CR12","doi-asserted-by":"crossref","first-page":"876","DOI":"10.1097\/ICO.0b013e3182408cef","volume":"31","author":"Q Le","year":"2012","unstructured":"Le Q, Wang X, Lv J et al (2012) In vivo laser scanning confocal microscopy of the cornea in patients with silicone oil tamponade after vitreoretinal surgery. Cornea 31:876\u2013882","journal-title":"Cornea"},{"key":"519_CR13","doi-asserted-by":"crossref","first-page":"1256","DOI":"10.1097\/ICO.0b013e3181d9284b","volume":"29","author":"K Kamiya","year":"2010","unstructured":"Kamiya K, Shimizu K, Ohmoto F et al (2010) Time course of corneal biomechanical parameters after phacoe-mulsification with intraocular lens implantation. Cornea 29:1256\u20131260","journal-title":"Cornea"},{"key":"519_CR14","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1167\/iovs.13-13172","volume":"55","author":"A Smedowski","year":"2014","unstructured":"Smedowski A, Weglarz B, Tarnawska D et al (2014) Comparison of three intraocular pressure measurement methods including biomechanical properties of the cornea. Investig Ophthalmol Vis Sci 55:666\u2013673","journal-title":"Investig Ophthalmol Vis Sci"},{"key":"519_CR15","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1167\/iovs.12-10984","volume":"54","author":"J Hong","year":"2013","unstructured":"Hong J, Xu J, Wei A et al (2013) A new tonometer-the Corvis ST tonometer: clinical comparison with noncontact and Goldmann applanation tonometers. Investig Ophthalmol Vis Sci 54:659\u2013665","journal-title":"Investig Ophthalmol Vis Sci"},{"key":"519_CR16","doi-asserted-by":"crossref","first-page":"2885","DOI":"10.1167\/iovs.12-11563","volume":"54","author":"CK Leung","year":"2013","unstructured":"Leung CK, Ye C, Weinreb RN (2013) An ultra-high speed Scheimpflug camera for evaluation for corneal deformation response and its impact on IOP measurements. Investig Ophthalmol Vis Sci 54:2885\u20132892","journal-title":"Investig Ophthalmol Vis Sci"},{"key":"519_CR17","doi-asserted-by":"crossref","first-page":"5078","DOI":"10.1167\/iovs.13-12509","volume":"54","author":"S Kling","year":"2013","unstructured":"Kling S, Marcos S (2013) Contributing factors to corneal deformation in air puff measurements. Investig Ophthalmol Vis Sci 54:5078\u20135085","journal-title":"Investig Ophthalmol Vis Sci"},{"key":"519_CR18","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1016\/j.ajo.2013.12.024","volume":"157","author":"T Huseynova","year":"2014","unstructured":"Huseynova T, Waring GO 4th, Roberts C et al (2014) Corneal biomechanics as a function of intraocular pressure and pachymetry by dynamic infrared signal and Scheimpflug imaging analysis in normal eyes. Am J Ophthalmol 157:885\u2013893","journal-title":"Am J Ophthalmol"}],"container-title":["International Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10792-017-0519-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-017-0519-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-017-0519-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,5,2]],"date-time":"2018-05-02T13:58:41Z","timestamp":1525269521000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10792-017-0519-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,4,25]]},"references-count":18,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018,4]]}},"alternative-id":["519"],"URL":"https:\/\/doi.org\/10.1007\/s10792-017-0519-1","relation":{},"ISSN":["0165-5701","1573-2630"],"issn-type":[{"value":"0165-5701","type":"print"},{"value":"1573-2630","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,4,25]]}}}