{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T07:34:10Z","timestamp":1740123250912,"version":"3.37.3"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2017,6,24]],"date-time":"2017-06-24T00:00:00Z","timestamp":1498262400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int Ophthalmol"],"published-print":{"date-parts":[[2018,8]]},"DOI":"10.1007\/s10792-017-0617-0","type":"journal-article","created":{"date-parts":[[2017,6,24]],"date-time":"2017-06-24T09:12:34Z","timestamp":1498295554000},"page":"1541-1547","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["A sample predictive model for intraocular pressure following laser in situ keratomileusis for myopia and an \u201cintraocular pressure constant\u201d"],"prefix":"10.1007","volume":"38","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8990-9365","authenticated-orcid":false,"given":"Ayse Ebru","family":"Bahadir Kilavuzoglu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tahir Kansu","family":"Bozkurt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cemile Banu","family":"Cosar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"As\u0131m Bozkurt","family":"Sener","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2017,6,24]]},"reference":[{"key":"617_CR1","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1097\/ICU.0000000000000065","volume":"25","author":"WJ Yao","year":"2014","unstructured":"Yao WJ, Crossan AS (2014) An update on postrefractive surgery intraocular pressure determination. Curr Opin Ophthalmol 25:258\u2013263. doi: 10.1097\/ICU.0000000000000065","journal-title":"Curr Opin Ophthalmol"},{"key":"617_CR2","doi-asserted-by":"crossref","first-page":"263","DOI":"10.3928\/1081-597X-20060301-11","volume":"22","author":"M Kohlhaas","year":"2006","unstructured":"Kohlhaas M, Spoerl E, Boehm AG, Pollack K (2006) A correction formula for the real intraocular pressure after LASIK for the correction of myopic astigmatism. J Refract Surg 22:263\u2013267","journal-title":"J Refract Surg"},{"key":"617_CR3","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1016\/j.ajo.2005.10.022","volume":"141","author":"CC Yang","year":"2006","unstructured":"Yang CC, Wang IJ, Chang YC, Lin LL, Chen TH (2006) A predictive model for postoperative intraocular pressure among patients undergoing laser in situ keratomileusis (LASIK). Am J Ophthalmol 141:530\u2013536","journal-title":"Am J Ophthalmol"},{"key":"617_CR4","first-page":"139","volume":"31","author":"Y Kucuksumer","year":"2001","unstructured":"Kucuksumer Y, Sivrikaya H, Bayraktar S, Yilmaz OF (2001) Effects of ocular parameters on intraocular pressure changes after laser in situ keratomileusis. Turk J Ophthalmol 31:139\u2013145","journal-title":"Turk J Ophthalmol"},{"key":"617_CR5","first-page":"186","volume":"3","author":"S Sentut","year":"2008","unstructured":"Sentut S, Yilmaz S, Maden A (2008) Comparison of intraocular pressure measurements from peripheral and central cornea after LASIK procedure. J Glaucoma Cataract 3:186\u2013189","journal-title":"J Glaucoma Cataract"},{"key":"617_CR6","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1111\/j.1442-9071.2011.02641","volume":"40","author":"AS Tsai","year":"2012","unstructured":"Tsai AS, Loon SC (2012) Intraocular pressure assessment after laser in situ keratomileusis: a review. Clin Exp Ophthalmol 40:295\u2013304. doi: 10.1111\/j.1442-9071.2011.02641","journal-title":"Clin Exp Ophthalmol"},{"key":"617_CR7","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1097\/01.ico.0000164833.69668.02","volume":"25","author":"AC Cheng","year":"2006","unstructured":"Cheng AC, Fan D, Tang E, Lam DS (2006) Effect of corneal curvature and corneal thickness on the assessment of intraocular pressure using noncontact tonometry in patients after myopic LASIK surgery. Cornea 25:26\u201328","journal-title":"Cornea"},{"key":"617_CR8","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1016\/j.ophtha.2004.12.033","volume":"112","author":"DH Chang","year":"2005","unstructured":"Chang DH, Stulting RD (2005) Change in intraocular pressure measurements after LASIK the effect of the refractive correction and the lamellar flap. Ophthalmology 112:1009\u20131016","journal-title":"Ophthalmology"},{"key":"617_CR9","volume-title":"Analysis of longitudinal data","author":"PJ Diggle","year":"1994","unstructured":"Diggle PJ, Liang KY, Zeger SL (1994) Analysis of longitudinal data. Oxford University Press, New York"},{"key":"617_CR10","doi-asserted-by":"crossref","first-page":"2010","DOI":"10.1016\/S0161-6420(99)90416-5","volume":"106","author":"P Mitchell","year":"1999","unstructured":"Mitchell P, Hourihan F, Sandbach J, Wang JJ (1999) The relationship between glaucoma and myopia: the Blue Mountains Eye Study. Ophthalmology 106:2010\u20132015","journal-title":"Ophthalmology"},{"key":"617_CR11","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1016\/S0886-3350(98)80222-8","volume":"24","author":"B Emara","year":"1998","unstructured":"Emara B, Probst LE, Tingey DP, Kennedy DW, Willms LJ, Machat J (1998) Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis. J Cataract Refract Surg 24:1320\u20131325","journal-title":"J Cataract Refract Surg"},{"key":"617_CR12","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1016\/S0002-9394(14)71125-0","volume":"123","author":"RC Wolfs","year":"1997","unstructured":"Wolfs RC, Klaver CC, Vingerling JR, Grobbee DE, Hofman A, de Jong PT (1997) Distribution of central corneal thickness and its association with intraocular pressure: the Rotterdam study. Am J Ophthalmol 123:767\u2013772","journal-title":"Am J Ophthalmol"},{"key":"617_CR13","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1159\/000303213","volume":"134","author":"H Goldmann","year":"1957","unstructured":"Goldmann H, Schmidt T (1957) Applanation tonometry. Ophthalmologica 134:221\u2013242","journal-title":"Ophthalmologica"},{"key":"617_CR14","doi-asserted-by":"crossref","first-page":"156","DOI":"10.4274\/tod.40.156","volume":"40","author":"YB Sakalar","year":"2010","unstructured":"Sakalar YB, Keklikci U, Balsak S, Dogan E, Unlu K (2010) Comparison of different methods for measurement of intraocular pressure and evaluation of effect of central corneal thickness on measurement results. Turk J Ophthalmol 40:156\u2013159","journal-title":"Turk J Ophthalmol"},{"key":"617_CR15","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1016\/S0161-6420(97)30202-4","volume":"104","author":"PG Mardelli","year":"1997","unstructured":"Mardelli PG, Piebenga LW, Whitacre MM, Siegmund KD (1997) The effect of excimer laser photorefractive keratectomy on intraocular pressure measurements using the Goldmann applanation tonometer. Ophthalmology 104:945\u2013948","journal-title":"Ophthalmology"},{"key":"617_CR16","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1097\/00003226-200007000-00022","volume":"19","author":"JA Gimeno","year":"2000","unstructured":"Gimeno JA, Munoz LA, Valenzuela LA, Molto FJ, Rahhal MS (2000) Influence of refraction on tonometric readings after photorefractive keratectomy and laser assisted in situ keratomileusis. Cornea 19:512\u2013516","journal-title":"Cornea"},{"key":"617_CR17","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/S0886-3350(00)00782-3","volume":"27","author":"HJ Park","year":"2001","unstructured":"Park HJ, Uhm KB, Hong C (2001) Reduction in intraocular pressure after laser in situ keratomileusis. J Cataract Refract Surg 27:303\u2013309","journal-title":"J Cataract Refract Surg"},{"key":"617_CR18","doi-asserted-by":"crossref","first-page":"97","DOI":"10.3928\/1081-597X-20010301-01","volume":"17","author":"MA Danasoury El","year":"2001","unstructured":"El Danasoury MA, El Maghraby A, Coorpender SJ (2001) Change in intraocular pressure in myopic eyes measured with contact and non-contact tonometers after laser in situ keratomileusis. J Refract Surg 17:97\u2013104","journal-title":"J Refract Surg"},{"key":"617_CR19","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1097\/00061198-200108000-00003","volume":"10","author":"S Duch","year":"2001","unstructured":"Duch S, Serra A, Castanera J, Abos R, Quintana M (2001) Tonometry after laser in situ keratomileusis treatment. J Glaucoma 10:261\u2013265","journal-title":"J Glaucoma"},{"key":"617_CR20","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1136\/bjo.2004.048074","volume":"89","author":"E Chihara","year":"2005","unstructured":"Chihara E, Takahashi H, Okazaki K, Park M, Tanito M (2005) The preoperative intraocular pressure level predicts the amount of underestimated intraocular pressure after LASIK for myopia. Br J Ophthalmol 89:160\u2013164","journal-title":"Br J Ophthalmol"},{"key":"617_CR21","doi-asserted-by":"crossref","first-page":"1480","DOI":"10.1016\/S0886-3350(00)00546-0","volume":"26","author":"OF Recep","year":"2000","unstructured":"Recep OF, Cagil N, Hasiripi H (2000) Correlation between intraocular pressure and corneal stromal thickness after laser in situ keratomileusis. J Cataract Refract Surg 26:1480\u20131483","journal-title":"J Cataract Refract Surg"},{"key":"617_CR22","doi-asserted-by":"crossref","first-page":"43","DOI":"10.3921\/joptom.2008.43","volume":"1","author":"CGV Moraes De","year":"2008","unstructured":"De Moraes CGV, Prata TS, Liebmann J, Ritch R (2008) Modalities of tonometry and their accuracy with respect to corneal thickness and irregularities. J Optom 1:43\u201349","journal-title":"J Optom"},{"key":"617_CR23","doi-asserted-by":"publisher","first-page":"320","DOI":"10.3928\/1081597X-20130415-03","volume":"29","author":"Y Zhang","year":"2013","unstructured":"Zhang Y, Chen YG, Xia YJ (2013) Comparison of corneal flap morphology using AS-OCT in LASIK with the WaveLight FS200 femtosecond laser versus a mechanical microkeratome. J Refract Surg 29:320\u2013324. doi: 10.3928\/1081597X-20130415-03","journal-title":"J Refract Surg"},{"key":"617_CR24","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1097\/ICU.0000000000000070","volume":"25","author":"MR Santhiago","year":"2014","unstructured":"Santhiago MR, Kara-Junior N, Waring GO 4th (2014) Microkeratome versus femtosecond flaps: accuracy and complications. Curr Opin Ophthalmol 25:270\u2013274. doi: 10.1097\/ICU.0000000000000070","journal-title":"Curr Opin Ophthalmol"},{"key":"617_CR25","doi-asserted-by":"crossref","first-page":"110","DOI":"10.2174\/1874609811104020110","volume":"4","author":"G Guedes","year":"2011","unstructured":"Guedes G, Tsai JC, Loewen NA (2011) Glaucoma and aging. Curr Aging Sci 4:110\u2013117","journal-title":"Curr Aging Sci"}],"container-title":["International Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10792-017-0617-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-017-0617-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-017-0617-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,30]],"date-time":"2022-07-30T00:59:05Z","timestamp":1659142745000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10792-017-0617-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6,24]]},"references-count":25,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2018,8]]}},"alternative-id":["617"],"URL":"https:\/\/doi.org\/10.1007\/s10792-017-0617-0","relation":{},"ISSN":["0165-5701","1573-2630"],"issn-type":[{"type":"print","value":"0165-5701"},{"type":"electronic","value":"1573-2630"}],"subject":[],"published":{"date-parts":[[2017,6,24]]}}}