{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,2]],"date-time":"2026-01-02T17:31:26Z","timestamp":1767375086017},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2018,10,23]],"date-time":"2018-10-23T00:00:00Z","timestamp":1540252800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int Ophthalmol"],"published-print":{"date-parts":[[2019,9]]},"DOI":"10.1007\/s10792-018-1036-6","type":"journal-article","created":{"date-parts":[[2018,10,23]],"date-time":"2018-10-23T03:43:42Z","timestamp":1540266222000},"page":"2015-2021","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Investigation of scleral thermal injuries caused by ultrasonic pars plana phacoemulsification and aspiration using pig eyes"],"prefix":"10.1007","volume":"39","author":[{"given":"Takaki","family":"Sato","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toru","family":"Yasuhara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masanori","family":"Fukumoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masashi","family":"Mimura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takatoshi","family":"Kobayashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Teruyo","family":"Kida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shota","family":"Kojima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hidehiro","family":"Oku","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tsunehiko","family":"Ikeda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,10,23]]},"reference":[{"issue":"3","key":"1036_CR1","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1097\/ICU.0b013e328329eaea","volume":"20","author":"MJ Spirn","year":"2009","unstructured":"Spirn MJ (2009) Comparison of 25, 23 and 20-gauge vitrectomy. Curr Opin Ophthalmol 20(3):195\u2013199","journal-title":"Curr Opin Ophthalmol"},{"issue":"4","key":"1036_CR2","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1136\/bjo.2007.114637","volume":"92","author":"H Lany von","year":"2008","unstructured":"von Lany H, Mahmood S, James CR, Cole MD, Charles SJ, Foot B, Gouws P, Shaw S (2008) Displacement of nuclear fragments into the vitreous complicating phacoemulsification surgery in the UK: clinical features, outcomes and management. Br J Ophthalmol 92(4):493\u2013495","journal-title":"Br J Ophthalmol"},{"issue":"11","key":"1036_CR3","doi-asserted-by":"publisher","first-page":"1829","DOI":"10.1016\/S0886-3350(01)00908-7","volume":"27","author":"P Ernest","year":"2001","unstructured":"Ernest P, Rhem M, McDermott M, Lavery K, Sensoli A (2001) Phacoemulsification conditions resulting in thermal wound injury. J Cataract Refract Surg 27(11):1829\u20131839","journal-title":"J Cataract Refract Surg"},{"issue":"3\u20134","key":"1036_CR4","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1076\/soph.17.3.102.14776","volume":"17","author":"KC Sippel","year":"2002","unstructured":"Sippel KC, Pineda R Jr (2002) Phacoemulsification and thermal wound injury. Semin Ophthalmol 17(3\u20134):102\u2013109","journal-title":"Semin Ophthalmol"},{"issue":"1","key":"1036_CR5","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/S0886-3350(99)80012-1","volume":"25","author":"H Bissen-Miyajima","year":"1999","unstructured":"Bissen-Miyajima H, Shimmura S, Tsubota K (1999) Thermal effect on corneal incisions with different phacoemulsification ultrasonic tips. J Cataract Refract Surg 25(1):60\u201364","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"1036_CR6","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1016\/j.ajo.2005.08.018","volume":"141","author":"MJ Bradley","year":"2006","unstructured":"Bradley MJ, Olson RJ (2006) A survey about phacoemulsification incision thermal contraction incidence and causal relationships. Am J Ophthalmol 141(1):222\u2013224","journal-title":"Am J Ophthalmol"},{"issue":"11","key":"1036_CR7","doi-asserted-by":"publisher","first-page":"2061","DOI":"10.1016\/S0886-3350(02)01788-1","volume":"28","author":"B Chang","year":"2002","unstructured":"Chang B, O\u2019Reilly P, Tormey P (2002) Thermal injury in phacoemulsification: a survey of eye surgeons in Ireland. J Cataract Refract Surg 28(11):2061\u20132062","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"1036_CR8","doi-asserted-by":"publisher","first-page":"463469","DOI":"10.1055\/s-2000-8142","volume":"108","author":"Y Fujiwara","year":"2000","unstructured":"Fujiwara Y, Inukai T, Aso Y, Takemura Y (2000) Thermographic measurement of skin temperature recovery time of extremities in patients with type 2 diabetes mellitus. Exp Clin Endocrinol Diabetes 108(7):463469","journal-title":"Exp Clin Endocrinol Diabetes"},{"issue":"6","key":"1036_CR9","doi-asserted-by":"publisher","first-page":"570","DOI":"10.3928\/23258160-20141118-13","volume":"45","author":"EJ Sigler","year":"2014","unstructured":"Sigler EJ, Calzada JI (2014) 25-gauge pars plana lensectomy with vitrectomy. Ophthalmic Surg Lasers Imaging Retina 45(6):570\u2013572","journal-title":"Ophthalmic Surg Lasers Imaging Retina"},{"issue":"4","key":"1036_CR10","doi-asserted-by":"publisher","first-page":"351","DOI":"10.3928\/15428877-20120531-04","volume":"43","author":"R Bhandari","year":"2012","unstructured":"Bhandari R, Ernst BJ, Stafeeva K, Mandava N, Quiroz-Mercado H (2012) 23-gauge vitrectomy for retained lens material. Ophthalmic Surg Lasers Imaging 43(4):351\u2013352","journal-title":"Ophthalmic Surg Lasers Imaging"},{"issue":"4","key":"1036_CR11","doi-asserted-by":"publisher","first-page":"625","DOI":"10.2147\/OPTH.S11837","volume":"21","author":"P Kongsap","year":"2010","unstructured":"Kongsap P (2010) Combined 20-gauge and 23-gauge pars plana vitrectomy for the management of posteriorly dislocated lens: a case series. Clin Ophthalmol 21(4):625\u2013628","journal-title":"Clin Ophthalmol"},{"key":"1036_CR12","doi-asserted-by":"publisher","first-page":"1737","DOI":"10.2147\/OPTH.S22331","volume":"5","author":"M Cho","year":"2011","unstructured":"Cho M, Chan RP (2011) 23-gauge pars plana vitrectomy for management of posteriorly dislocated crystalline lens. Clin Ophthalmol 5:1737\u20131743","journal-title":"Clin Ophthalmol"},{"issue":"4","key":"1036_CR13","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1016\/j.sjopt.2014.01.001","volume":"28","author":"KM Koh","year":"2014","unstructured":"Koh KM, Kim HS, Cho HJ, Lew YJ, Choi MJ, Han JI, Cho SW, Kim CG, Lee TG, Kim JW, Yoo SJ (2014) Surgical outcomes of 23-gauge vitrectomy for the management of lens fragments dropped into the vitreous cavity during cataract surgery. Saudi J Ophthalmol 28(4):253\u2013256","journal-title":"Saudi J Ophthalmol"},{"issue":"4","key":"1036_CR14","first-page":"833","volume":"8","author":"B Takkar","year":"2015","unstructured":"Takkar B, Azad R, Azad S, Rathi A (2015) Posterior segment nucleotomy for dislocated sclerotic cataractous lens using chandelier endoilluminator and sharp tipped chopper. Int J Ophthalmol 8(4):833\u2013834","journal-title":"Int J Ophthalmol"},{"key":"1036_CR15","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1159\/000360471","volume":"54","author":"M Nagpal","year":"2014","unstructured":"Nagpal M, Jain P (2014) Dropped lens fragment, dislocated intraocular lens. Dev Ophthalmol 54:234\u2013242","journal-title":"Dev Ophthalmol"},{"issue":"3","key":"1036_CR16","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1097\/IAE.0000000000001197","volume":"37","author":"A Tzamalis","year":"2017","unstructured":"Tzamalis A, Symeonidis C, Brazitikou IP, Tzetzi D, Chalvatzis N, Androudi S, Brazitikos P (2017) Sutureless clear corneal ultrasonic fragmentation for retained lens fragments: a Pilot Study. Retina 37(3):494\u2013499","journal-title":"Retina"},{"issue":"8","key":"1036_CR17","doi-asserted-by":"publisher","first-page":"1058","DOI":"10.1136\/bjophthalmol-2011-300864","volume":"96","author":"H Nakasato","year":"2012","unstructured":"Nakasato H, Uemoto R, Kawagoe T, Okada E, Mizuki N (2012) Immediate removal of posteriorly dislocated lens fragments through sclerocorneal incision during cataract surgery. Br J Ophthalmol 96(8):1058\u20131062","journal-title":"Br J Ophthalmol"},{"issue":"3","key":"1036_CR18","doi-asserted-by":"publisher","first-page":"268","DOI":"10.4103\/2008-322X.188406","volume":"11","author":"V Kumar","year":"2016","unstructured":"Kumar V, Takkar B (2016) Intravitreal phacoemulsification using torsional handpiece for retained lens fragments. J Ophthalmic Vis Res 11(3):268\u2013270","journal-title":"J Ophthalmic Vis Res"},{"issue":"12","key":"1036_CR19","doi-asserted-by":"publisher","first-page":"4641","DOI":"10.1167\/iovs.05-0843","volume":"46","author":"MF Simpanya","year":"2005","unstructured":"Simpanya MF, Ansari RR, Suh KI, Leverenz VR, Giblin FJ (2005) Aggregation of lens crystallins in an in vivo hyperbaric oxygen guinea pig model of nuclear cataract: dynamic light-scattering and HPLC analysis. Invest Ophthalmol Vis Sci 46(12):4641\u20134651","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"1","key":"1036_CR20","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/S0886-3350(01)01235-4","volume":"28","author":"H Tsuneoka","year":"2002","unstructured":"Tsuneoka H, Shiba T, Takahashi Y (2002) Ultrasonic phacoemulsification using a 1.4\u00a0mm incision: clinical results. J Cataract Refract Surg 28(1):81\u201386","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"1036_CR21","doi-asserted-by":"publisher","first-page":"934","DOI":"10.1016\/S0886-3350(01)00822-7","volume":"27","author":"H Tsuneoka","year":"2001","unstructured":"Tsuneoka H, Shiba T, Takahashi Y (2001) Feasibility of ultrasound cataract surgery with a 1.4\u00a0mm incision. J Cataract Refract Surg 27(6):934\u2013940","journal-title":"J Cataract Refract Surg"}],"container-title":["International Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-018-1036-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10792-018-1036-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-018-1036-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,25]],"date-time":"2019-10-25T23:22:21Z","timestamp":1572045741000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10792-018-1036-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10,23]]},"references-count":21,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2019,9]]}},"alternative-id":["1036"],"URL":"https:\/\/doi.org\/10.1007\/s10792-018-1036-6","relation":{},"ISSN":["0165-5701","1573-2630"],"issn-type":[{"value":"0165-5701","type":"print"},{"value":"1573-2630","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,10,23]]},"assertion":[{"value":"24 June 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 October 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 October 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants and animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}