{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,2]],"date-time":"2026-01-02T07:08:36Z","timestamp":1767337716877,"version":"3.37.3"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2019,11,23]],"date-time":"2019-11-23T00:00:00Z","timestamp":1574467200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,11,23]],"date-time":"2019-11-23T00:00:00Z","timestamp":1574467200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int Ophthalmol"],"published-print":{"date-parts":[[2020,3]]},"DOI":"10.1007\/s10792-019-01222-5","type":"journal-article","created":{"date-parts":[[2019,11,23]],"date-time":"2019-11-23T07:02:41Z","timestamp":1574492561000},"page":"617-626","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Toric IOL positioning with a no-touch head-up display axis alignment"],"prefix":"10.1007","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3946-5759","authenticated-orcid":false,"given":"J.","family":"Luebke","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"Boehringer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"Maier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Reinhard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"Eberwein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,11,23]]},"reference":[{"key":"1222_CR1","doi-asserted-by":"publisher","first-page":"1479","DOI":"10.1016\/j.jcrs.2010.02.025","volume":"36","author":"PC Hoffmann","year":"2010","unstructured":"Hoffmann PC, H\u00fctz WW (2010) Analysis of biometry and prevalence data for corneal astigmatism in 23,239 eyes. J Cataract Refract Surg 36:1479\u20131485","journal-title":"J Cataract Refract Surg"},{"key":"1222_CR2","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.jcrs.2014.08.029","volume":"41","author":"JL Ali\u00f3","year":"2015","unstructured":"Ali\u00f3 JL, Soria F, Abbouda A, Pe\u00f1a-Garc\u00eda P (2015) Laser in situ keratomileusis for \u22126.00 to \u221218.00 diopters of myopia and up to \u22125.00 diopters of astigmatism: 15-year follow-up. J Cataract Refract Surg 41:33\u201340","journal-title":"J Cataract Refract Surg"},{"key":"1222_CR3","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1016\/j.jcrs.2013.08.049","volume":"40","author":"N Hirnschall","year":"2014","unstructured":"Hirnschall N, Gangwani V, Crnej A, Koshy J, Maurino V, Findl O (2014) Correction of moderate corneal astigmatism during cataract surgery: toric intraocular lens versus peripheral corneal relaxing incisions. J Cataract Refract Surg 40:354\u2013361","journal-title":"J Cataract Refract Surg"},{"key":"1222_CR4","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1016\/j.ophtha.2015.10.002","volume":"123","author":"L Kessel","year":"2016","unstructured":"Kessel L, Andresen J, Tendal B, Erngaard D, Flesner P, Hjortdal J (2016) Toric intraocular lenses in the correction of astigmatism during cataract surgery: a systematic review and meta-analysis. Ophthalmology 123:275\u2013286","journal-title":"Ophthalmology"},{"key":"1222_CR5","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1055\/s-2006-926652","volume":"223","author":"HB Dick","year":"2006","unstructured":"Dick HB, Krummenauer F, Tr\u00f6ber L (2006) Ausgleich des kornealen Astigmatismus mit torischer Intraokularlinse: ergebnisse der Multicenterstudie. Klin Monatsbl\u00e4tter F\u00fcr Augenheilkd 223:593\u2013608","journal-title":"Klin Monatsbl\u00e4tter F\u00fcr Augenheilkd"},{"key":"1222_CR6","doi-asserted-by":"publisher","first-page":"658","DOI":"10.3928\/1081597X-20150611-01","volume":"31","author":"S Shah","year":"2015","unstructured":"Shah S, Peris-Martinez C, Reinhard T, Vinciguerra P (2015) Visual outcomes after cataract surgery: multifocal versus monofocal intraocular lenses. J Refract Surg 31:658\u2013666","journal-title":"J Refract Surg"},{"key":"1222_CR7","doi-asserted-by":"publisher","first-page":"1394","DOI":"10.1016\/j.jcrs.2011.02.024","volume":"37","author":"N Visser","year":"2011","unstructured":"Visser N, Berendschot TTJM, Bauer NJC, Jurich J, Kersting O, Nuijts RMMA (2011) Accuracy of toric intraocular lens implantation in cataract and refractive surgery. J Cataract Refract Surg 37:1394\u20131402","journal-title":"J Cataract Refract Surg"},{"key":"1222_CR8","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1136\/bjo.2009.163485","volume":"94","author":"J Kwartz","year":"2010","unstructured":"Kwartz J, Edwards K (2010) Evaluation of the long-term rotational stability of single-piece, acrylic intraocular lenses. Br J Ophthalmol 94:1003\u20131006","journal-title":"Br J Ophthalmol"},{"key":"1222_CR9","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1016\/j.jcrs.2007.01.030","volume":"33","author":"F Weinand","year":"2007","unstructured":"Weinand F, Jung A, Stein A, Pf\u00fctzner A, Becker R, Pavlovic S (2007) Rotational stability of a single-piece hydrophobic acrylic intraocular lens: new method for high-precision rotation control. J Cataract Refract Surg 33:800\u2013803","journal-title":"J Cataract Refract Surg"},{"key":"1222_CR10","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1016\/j.jcrs.2013.02.020","volume":"39","author":"N Visser","year":"2013","unstructured":"Visser N, Bauer NJC, Nuijts RMMA (2013) Toric intraocular lenses: historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complications. J Cataract Refract Surg 39:624\u2013637","journal-title":"J Cataract Refract Surg"},{"key":"1222_CR11","doi-asserted-by":"publisher","first-page":"2094","DOI":"10.1016\/j.jcrs.2012.07.039","volume":"38","author":"N Popp","year":"2012","unstructured":"Popp N, Hirnschall N, Maedel S, Findl O (2012) Evaluation of 4 corneal astigmatic marking methods. J Cataract Refract Surg 38:2094\u20132099","journal-title":"J Cataract Refract Surg"},{"key":"1222_CR12","doi-asserted-by":"publisher","first-page":"1232","DOI":"10.1016\/j.jcrs.2014.09.045","volume":"41","author":"YJ Woo","year":"2015","unstructured":"Woo YJ, Lee H, Kim HS, Kim EK, Seo KY, Kim T (2015) Comparison of 3 marking techniques in preoperative assessment of toric intraocular lenses using a wavefront aberrometer. J Cataract Refract Surg 41:1232\u20131240","journal-title":"J Cataract Refract Surg"},{"key":"1222_CR13","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/S0886-3350(00)00798-7","volume":"27","author":"N Alpins","year":"2001","unstructured":"Alpins N (2001) Astigmatism analysis by the Alpins method. J Cataract Refract Surg 27:31\u201349","journal-title":"J Cataract Refract Surg"},{"key":"1222_CR14","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1016\/S0886-3350(13)80617-7","volume":"19","author":"NA Alpins","year":"1993","unstructured":"Alpins NA (1993) A new method of analyzing vectors for changes in astigmatism. J Cataract Refract Surg 19:524\u2013533","journal-title":"J Cataract Refract Surg"},{"unstructured":"R Core Team (2019) R: a language and environment for statistical computing. https:\/\/www.R-project.org","key":"1222_CR15"},{"key":"1222_CR16","doi-asserted-by":"publisher","first-page":"1846","DOI":"10.1016\/j.jcrs.2013.06.019","volume":"39","author":"Y Hasegawa","year":"2013","unstructured":"Hasegawa Y, Okamoto F, Nakano S, Hiraoka T, Oshika T (2013) Effect of preoperative corneal astigmatism orientation on results with a toric intraocular lens. J Cataract Refract Surg 39:1846\u20131851","journal-title":"J Cataract Refract Surg"},{"key":"1222_CR17","doi-asserted-by":"publisher","first-page":"2104","DOI":"10.1016\/j.ophtha.2010.07.033","volume":"117","author":"E Holland","year":"2010","unstructured":"Holland E, Lane S, Horn JD, Ernest P, Arleo R, Miller KM (2010) The AcrySof Toric intraocular lens in subjects with cataracts and corneal astigmatism: a randomized, subject-masked, parallel-group, 1-year study. Ophthalmology 117:2104\u20132111","journal-title":"Ophthalmology"},{"key":"1222_CR18","doi-asserted-by":"publisher","first-page":"e1618","DOI":"10.1097\/md.0000000000001618","volume":"94","author":"AH Elhofi","year":"2015","unstructured":"Elhofi AH, Helaly HA (2015) Comparison between digital and manual marking for toric intraocular lenses. Medicine (Baltimore) 94:e1618. https:\/\/doi.org\/10.1097\/md.0000000000001618","journal-title":"Medicine (Baltimore)"},{"key":"1222_CR19","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.jcrs.2013.09.010","volume":"40","author":"EA Villegas","year":"2014","unstructured":"Villegas EA, Alc\u00f3n E, Artal P (2014) Minimum amount of astigmatism that should be corrected. J Cataract Refract Surg 40:13\u201319","journal-title":"J Cataract Refract Surg"},{"key":"1222_CR20","doi-asserted-by":"publisher","first-page":"1038","DOI":"10.1016\/j.jcrs.2010.12.053","volume":"37","author":"JL Ali\u00f3","year":"2011","unstructured":"Ali\u00f3 JL, Pi\u00f1ero DP, Tom\u00e1s J, Ales\u00f3n A (2011) Vector analysis of astigmatic changes after cataract surgery with toric intraocular lens implantation. J Cataract Refract Surg 37:1038\u20131049","journal-title":"J Cataract Refract Surg"},{"key":"1222_CR21","doi-asserted-by":"publisher","first-page":"1803","DOI":"10.1016\/j.jcrs.2013.06.027","volume":"39","author":"DD Koch","year":"2013","unstructured":"Koch DD, Jenkins RB, Weikert MP, Yeu E, Wang L (2013) Correcting astigmatism with toric intraocular lenses: effect of posterior corneal astigmatism. J Cataract Refract Surg 39:1803\u20131809","journal-title":"J Cataract Refract Surg"},{"key":"1222_CR22","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1167\/iovs.14-15903","volume":"56","author":"G Savini","year":"2015","unstructured":"Savini G, N\u00e6ser K (2015) An analysis of the factors influencing the residual refractive astigmatism after cataract surgery with toric intraocular lenses. Investig Ophthalmol Vis Sci 56:827\u2013835","journal-title":"Investig Ophthalmol Vis Sci"},{"key":"1222_CR23","doi-asserted-by":"publisher","first-page":"2034","DOI":"10.1016\/j.jcrs.2011.05.041","volume":"37","author":"N Visser","year":"2011","unstructured":"Visser N, Nuijts RMMA, de Vries NE, Bauer NJC (2011) Visual outcomes and patient satisfaction after cataract surgery with toric multifocal intraocular lens implantation. J Cataract Refract Surg 37:2034\u20132042","journal-title":"J Cataract Refract Surg"}],"container-title":["International Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-019-01222-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10792-019-01222-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-019-01222-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,11,22]],"date-time":"2020-11-22T00:05:23Z","timestamp":1606003523000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10792-019-01222-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,23]]},"references-count":23,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020,3]]}},"alternative-id":["1222"],"URL":"https:\/\/doi.org\/10.1007\/s10792-019-01222-5","relation":{},"ISSN":["0165-5701","1573-2630"],"issn-type":[{"type":"print","value":"0165-5701"},{"type":"electronic","value":"1573-2630"}],"subject":[],"published":{"date-parts":[[2019,11,23]]},"assertion":[{"value":"4 July 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 November 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 November 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"All authors declare that they have no conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the local ethics committee of the University of Freiburg (vote no. 432\/16) and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. Informed consent was not needed due to the retrospective nature of the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}