{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T03:08:19Z","timestamp":1790996899786,"version":"4.1.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2021,7,27]],"date-time":"2021-07-27T00:00:00Z","timestamp":1627344000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,7,27]],"date-time":"2021-07-27T00:00:00Z","timestamp":1627344000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int Ophthalmol"],"published-print":{"date-parts":[[2021,12]]},"DOI":"10.1007\/s10792-021-01973-0","type":"journal-article","created":{"date-parts":[[2021,7,27]],"date-time":"2021-07-27T14:02:55Z","timestamp":1627394575000},"page":"4009-4015","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Outcomes of toric IOL implantation guided by iris-registered femtosecond laser capsulotomy markings"],"prefix":"10.1007","volume":"41","author":[{"given":"Bradley P.","family":"O\u2019Neill","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vasilios F.","family":"Diakonis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3014-0453","authenticated-orcid":false,"given":"Konstantinos T.","family":"Tsaousis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert J.","family":"Weinstock","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,7,27]]},"reference":[{"key":"1973_CR1","doi-asserted-by":"publisher","first-page":"1479","DOI":"10.1016\/j.jcrs.2010.02.025","volume":"36","author":"PC Hoffmann","year":"2010","unstructured":"PC Hoffmann WW H\u00fctz 2010 Analysis of biometry and prevalence data for corneal astigmatism in 23,239 eyes J Cataract Refract Surg 36 1479 1485 https:\/\/doi.org\/10.1016\/j.jcrs.2010.02.025","journal-title":"J Cataract Refract Surg"},{"key":"1973_CR2","doi-asserted-by":"publisher","first-page":"1111","DOI":"10.1001\/archopht.126.8.1111","volume":"126","author":"S Vitale","year":"2008","unstructured":"S Vitale L Ellwein MF Cotch 2008 Prevalence of refractive error in the United States, 1999\u20132004 Arch Ophthalmol 126 1111 1119 https:\/\/doi.org\/10.1001\/archopht.126.8.1111","journal-title":"Arch Ophthalmol"},{"key":"1973_CR3","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1016\/j.ohc.2006.07.004","volume":"19","author":"LD Nichamin","year":"2006","unstructured":"LD Nichamin 2006 Astigmatism control Ophthalmol Clin North Am 19 485 493 https:\/\/doi.org\/10.1016\/j.ohc.2006.07.004","journal-title":"Ophthalmol Clin North Am"},{"key":"1973_CR4","doi-asserted-by":"publisher","first-page":"1834","DOI":"10.1016\/j.jcrs.2009.05.037","volume":"35","author":"JS Titiyal","year":"2009","unstructured":"JS Titiyal T Agarwal V Jhanji 2009 Toric intraocular lens versus opposite clear corneal incisions to correct astigmatism in eyes having cataract surgery J Cataract Refract Surg 35 1834 1835 https:\/\/doi.org\/10.1016\/j.jcrs.2009.05.037","journal-title":"J Cataract Refract Surg"},{"key":"1973_CR5","doi-asserted-by":"publisher","first-page":"2081","DOI":"10.1016\/j.jcrs.2011.09.002","volume":"37","author":"S Ganekal","year":"2011","unstructured":"S Ganekal S Dorairaj V Jhanji 2011 Limbal relaxing incisions during phacoemulsification: 6-month results J Cataract Refract Surg 37 2081 2082 https:\/\/doi.org\/10.1016\/j.jcrs.2011.09.002","journal-title":"J Cataract Refract Surg"},{"key":"1973_CR6","doi-asserted-by":"publisher","first-page":"528","DOI":"10.1016\/j.jcrs.2012.10.043","volume":"39","author":"T R\u00fcckl","year":"2013","unstructured":"T R\u00fcckl AK Dexl A Bachernegg 2013 Femtosecond laser-assisted intrastromal arcuate keratotomy to reduce corneal astigmatism J Cataract Refract Surg 39 528 538 https:\/\/doi.org\/10.1016\/j.jcrs.2012.10.043","journal-title":"J Cataract Refract Surg"},{"key":"1973_CR7","doi-asserted-by":"publisher","first-page":"416","DOI":"10.3928\/1081-597X-20030701-07","volume":"19","author":"H Norouzi","year":"2003","unstructured":"H Norouzi M Rahmati-Kamel 2003 Laser in situ keratomileusis for correction of induced astigmatism from cataract surgery J Refract Surg 19 416 424","journal-title":"J Refract Surg"},{"key":"1973_CR8","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.2147\/OPTH.S23345","volume":"5","author":"P Gunvant","year":"2011","unstructured":"P Gunvant A Ablamowicz S Gollamudi 2011 Predicting the necessity of LASIK enhancement after cataract surgery in patients with multifocal IOL implantation Clin Ophthalmol 5 1281 1285 https:\/\/doi.org\/10.2147\/OPTH.S23345","journal-title":"Clin Ophthalmol"},{"key":"1973_CR9","doi-asserted-by":"publisher","first-page":"1024","DOI":"10.1007\/s00347-007-1659-x","volume":"104","author":"GU Auffarth","year":"2007","unstructured":"GU Auffarth TM Rabsilber 2007 Toric IOLs after cataract surgery and refractive lens exchange Ophthalmologe 104 1024 1031 https:\/\/doi.org\/10.1007\/s00347-007-1659-x","journal-title":"Ophthalmologe"},{"key":"1973_CR10","doi-asserted-by":"publisher","first-page":"1340","DOI":"10.1016\/j.jcrs.2019.03.030","volume":"45","author":"F Zhou","year":"2019","unstructured":"F Zhou W Jiang Z Lin 2019 Comparative meta-analysis of toric intraocular lens alignment accuracy in cataract patients: Image-guided system versus manual marking J Cataract Refract Surg 45 1340 1345 https:\/\/doi.org\/10.1016\/j.jcrs.2019.03.030","journal-title":"J Cataract Refract Surg"},{"key":"1973_CR11","doi-asserted-by":"publisher","first-page":"703","DOI":"10.18240\/ijo.2016.05.11","volume":"9","author":"JH Farooqui","year":"2016","unstructured":"JH Farooqui A Koul R Dutta NM Shroff 2016 Comparison of two different methods of preoperative marking for toric intraocular lens implantation: bubble marker versus pendulum marker Int J Ophthalmol 9 703 706 https:\/\/doi.org\/10.18240\/ijo.2016.05.11","journal-title":"Int J Ophthalmol"},{"key":"1973_CR12","doi-asserted-by":"publisher","first-page":"e673","DOI":"10.1111\/aos.13063","volume":"94","author":"A Fadlallah","year":"2016","unstructured":"A Fadlallah E Chelala S Robinson S Melki 2016 Femtosecond laser intrastromal incisions as fiducial marks for alignment of toric IOLs Acta Ophthalmol 94 e673 e674 https:\/\/doi.org\/10.1111\/aos.13063","journal-title":"Acta Ophthalmol"},{"key":"1973_CR13","doi-asserted-by":"publisher","first-page":"176","DOI":"10.3928\/1081597X-20150224-01","volume":"31","author":"IR Hidalgo","year":"2015","unstructured":"IR Hidalgo JJ Rozema SN Dhubhghaill 2015 Repeatability and inter-device agreement for three different methods of keratometry: Placido, Scheimpflug, and color LED corneal topography J Refract Surg 31 176 181 https:\/\/doi.org\/10.3928\/1081597X-20150224-01","journal-title":"J Refract Surg"},{"key":"1973_CR14","doi-asserted-by":"publisher","first-page":"937","DOI":"10.1097\/ICO.0000000000000476","volume":"34","author":"AJ Kanellopoulos","year":"2015","unstructured":"AJ Kanellopoulos G Asimellis 2015 Distribution and repeatability of corneal astigmatism measurements (magnitude and axis) evaluated with color light emitting diode reflection topography Cornea 34 937 944 https:\/\/doi.org\/10.1097\/ICO.0000000000000476","journal-title":"Cornea"},{"key":"1973_CR15","doi-asserted-by":"publisher","first-page":"711","DOI":"10.3928\/1081597X-20180820-01","volume":"34","author":"VF Diakonis","year":"2018","unstructured":"VF Diakonis BF Swann RJ Weinstock 2018 Femtosecond laser-assisted capsulotomy markings for the alignment of toric iols: a new technique J Refract Surg 34 711 712 https:\/\/doi.org\/10.3928\/1081597X-20180820-01","journal-title":"J Refract Surg"},{"key":"1973_CR16","doi-asserted-by":"publisher","first-page":"941","DOI":"10.1111\/j.1365-2753.2008.01010.x","volume":"14","author":"JL Peters","year":"2008","unstructured":"JL Peters KL Mengersen 2008 Meta-analysis of repeated measures study designs J Eval Clin Pract 14 941 950 https:\/\/doi.org\/10.1111\/j.1365-2753.2008.01010.x","journal-title":"J Eval Clin Pract"},{"key":"1973_CR17","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1024\/0040-5930\/a000756","volume":"73","author":"R Menapace","year":"2016","unstructured":"R Menapace 2016 Developments in modern cataract surgery \u2013 a critical overview Ther Umsch 73 53 59 https:\/\/doi.org\/10.1024\/0040-5930\/a000756","journal-title":"Ther Umsch"},{"key":"1973_CR18","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1097\/ICU.0000000000000536","volume":"30","author":"M Moshirfar","year":"2019","unstructured":"M Moshirfar B Buckner YC Ronquillo D Hofstedt 2019 Biometry in cataract surgery: a review of the current literature Curr Opin Ophthalmol 30 9 12 https:\/\/doi.org\/10.1097\/ICU.0000000000000536","journal-title":"Curr Opin Ophthalmol"},{"key":"1973_CR19","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1097\/ICU.0000000000000433","volume":"29","author":"SY Ewe","year":"2018","unstructured":"SY Ewe RG Abell BJ Vote 2018 Femtosecond laser-assisted versus phacoemulsification for cataract extraction and intraocular lens implantation: clinical outcomes review Curr Opin Ophthalmol 29 54 60 https:\/\/doi.org\/10.1097\/ICU.0000000000000433","journal-title":"Curr Opin Ophthalmol"},{"key":"1973_CR20","doi-asserted-by":"publisher","first-page":"952","DOI":"10.1016\/j.jcrs.2017.04.034","volume":"43","author":"CD Hummel","year":"2017","unstructured":"CD Hummel VF Diakonis NR Desai 2017 Cyclorotation during femtosecond laser-assisted cataract surgery measured using iris registration J Cataract Refract Surg 43 952 955 https:\/\/doi.org\/10.1016\/j.jcrs.2017.04.034","journal-title":"J Cataract Refract Surg"},{"key":"1973_CR21","doi-asserted-by":"publisher","first-page":"1177","DOI":"10.1016\/j.jcrs.2019.03.021","volume":"45","author":"EV Teuma","year":"2019","unstructured":"EV Teuma G Gray R Bedi M Packer 2019 Femtosecond laser-assisted capsulotomy with capsular marks for toric IOL alignment: Comparison of tensile strength with standard femtosecond laser capsulotomy J Cataract Refract Surg 45 1177 1182 https:\/\/doi.org\/10.1016\/j.jcrs.2019.03.021","journal-title":"J Cataract Refract Surg"},{"key":"1973_CR22","doi-asserted-by":"publisher","first-page":"1720","DOI":"10.1016\/j.jcrs.2008.06.027","volume":"34","author":"J Chang","year":"2008","unstructured":"J Chang 2008 Cyclotorsion during laser in situ keratomileusis J Cataract Refract Surg 34 1720 1726 https:\/\/doi.org\/10.1016\/j.jcrs.2008.06.027","journal-title":"J Cataract Refract Surg"},{"key":"1973_CR23","doi-asserted-by":"publisher","first-page":"536","DOI":"10.3928\/1081597X-20200602-01","volume":"36","author":"D Cao","year":"2020","unstructured":"D Cao Y Xu Y Wang 2020 Comparison of toric intraocular lens alignment between femtosecond laser-assisted capsular marking and manual corneal marking J Refract Surg 36 536 542 https:\/\/doi.org\/10.3928\/1081597X-20200602-01","journal-title":"J Refract Surg"}],"container-title":["International Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-021-01973-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10792-021-01973-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-021-01973-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,7]],"date-time":"2021-11-07T09:03:39Z","timestamp":1636275819000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10792-021-01973-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,27]]},"references-count":23,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["1973"],"URL":"https:\/\/doi.org\/10.1007\/s10792-021-01973-0","relation":{},"ISSN":["0165-5701","1573-2630"],"issn-type":[{"value":"0165-5701","type":"print"},{"value":"1573-2630","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,7,27]]},"assertion":[{"value":"7 April 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 July 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 July 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Dr. Weinstock is a consultant\/has ownership interest with Alcon Laboratories, Inc., Bausch & Lomb, Inc., EyePoint Pharmaceuticals, Eyesafe, J&J Surgical Vision Inc., LENSAR, Ocular Therapeutix, Omeros Corp., Pogotec, Rapid Pathogen Screening, Inc., RxSight Inc., Sun Pharmaceutical Industries Inc., TissueTech and UBeam. None of the other authors has a financial or proprietary interest in any material or methods mentioned.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Prior to the study, an institutional review board approval was obtained.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Information is anonymized, and the submission does not include images that may identify the person.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Information is anonymized, and the submission does not include images that may identify the person.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}]}}