{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T00:25:52Z","timestamp":1783988752393,"version":"3.55.0"},"reference-count":9,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2022,10,29]],"date-time":"2022-10-29T00:00:00Z","timestamp":1667001600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,10,29]],"date-time":"2022-10-29T00:00:00Z","timestamp":1667001600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int Ophthalmol"],"DOI":"10.1007\/s10792-022-02551-8","type":"journal-article","created":{"date-parts":[[2022,10,29]],"date-time":"2022-10-29T03:20:19Z","timestamp":1667013619000},"page":"1553-1558","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Comparison of corneal flap thickness predictability and architecture between femtosecond laser and sub-Bowman keratomileusis microkeratome in laser in situ keratomileusis"],"prefix":"10.1007","volume":"43","clinical-trial-number":[{"clinical-trial-number":"nct04684888","registry":"10.18810\/clinical-trials-gov"}],"author":[{"given":"Suzan Amana","family":"Rattan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Riyam Faihan","family":"Rashid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mahir Kadhim","family":"Mutashar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yaser A. R.","family":"Nasser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Didar S.","family":"Anwar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,10,29]]},"reference":[{"issue":"4","key":"2551_CR1","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1016\/j.ophtha.2008.12.037","volume":"116","author":"KD Solomon","year":"2009","unstructured":"Solomon KD, Fern\u00e1ndez de Castro LE, Sandoval HP, Biber JM, Groat B, Neff KD, Ying MS, French JW, Donnenfeld ED, Lindstrom RL (2009) LASIK world literature review: quality of life and patient satisfaction. Ophthalmology 116(4):691\u2013701. https:\/\/doi.org\/10.1016\/j.ophtha.2008.12.037","journal-title":"Ophthalmology"},{"issue":"1","key":"2551_CR2","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/s0161-6420(01)00966-6","volume":"109","author":"A Sugar","year":"2002","unstructured":"Sugar A, Rapuano CJ, Culbertson WW, Huang D, Varley GA, Agapitos PJ, de Luise VP, Koch DD (2002) Laser in situ keratomileusis for myopia and astigmatism: safety and efficacy\u2014a report by the American Academy of Ophthalmology. Ophthalmology 109(1):175\u2013187. https:\/\/doi.org\/10.1016\/s0161-6420(01)00966-6","journal-title":"Ophthalmology"},{"issue":"1","key":"2551_CR3","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1186\/s12886-017-0520-5","volume":"17","author":"MA Torky","year":"2017","unstructured":"Torky MA, Al Zafiri YA, Khattab AM, Farag RK, Awad EA (2017) Visumax femtolasik versus Moria M2 microkeratome in mild to moderate myopia: efficacy, safety, predictability, aberrometric changes and flap thickness predictability. BMC Ophthalmol 17(1):125. https:\/\/doi.org\/10.1186\/s12886-017-0520-5","journal-title":"BMC Ophthalmol"},{"issue":"13","key":"2551_CR4","doi-asserted-by":"crossref","first-page":"2440","DOI":"10.3760\/cma.j.issn.0366-6999.20130918","volume":"126","author":"CB Zhai","year":"2013","unstructured":"Zhai CB, Tian L, Zhou YH, Zhang QW, Zhang J (2013) Comparison of the flaps made by femtosecond laser and automated keratomes for sub-bowman keratomileusis. Chin Med J 126(13):2440\u20132444","journal-title":"Chin Med J"},{"issue":"2","key":"2551_CR5","doi-asserted-by":"publisher","first-page":"273","DOI":"10.3980\/j.issn.2222-3959.2014.02.14","volume":"7","author":"J Zhang","year":"2014","unstructured":"Zhang J, Zhang SS, Yu Q, Wu JX, Lian JC (2014) Comparison of corneal flap thickness using a FS200 femtosecond laser and a moria SBK microkeratome. Int J Ophthalmol 7(2):273\u2013277. https:\/\/doi.org\/10.3980\/j.issn.2222-3959.2014.02.14","journal-title":"Int J Ophthalmol"},{"issue":"7","key":"2551_CR6","first-page":"1183","volume":"64","author":"KS Bower","year":"2001","unstructured":"Bower KS, Weichel ED, Kim TJ (2001) Overview of refractive surgery. Am Fam Physician 64(7):1183\u20131190","journal-title":"Am Fam Physician"},{"issue":"4","key":"2551_CR7","doi-asserted-by":"publisher","first-page":"CD012946","DOI":"10.1002\/14651858.CD012946.pub2","volume":"4","author":"N Kahuam-L\u00f3pez","year":"2020","unstructured":"Kahuam-L\u00f3pez N, Navas A, Castillo-Salgado C, Graue-Hernandez EO, Jimenez-Corona A, Ibarra A (2020) Laser-assisted in-situ keratomileusis (LASIK) with a mechanical microkeratome compared to LASIK with a femtosecond laser for LASIK in adults with myopia or myopic astigmatism. Cochrane Database Syst Rev 4(4):CD012946. https:\/\/doi.org\/10.1002\/14651858.CD012946.pub2","journal-title":"Cochrane Database Syst Rev"},{"issue":"6","key":"2551_CR8","doi-asserted-by":"publisher","first-page":"1506","DOI":"10.1177\/1120672120952034","volume":"30","author":"SA Rattan","year":"2020","unstructured":"Rattan SA, Anwar DS (2020) Comparison of corneal epithelial thickness profile in dry eye patients, keratoconus suspect, and healthy eyes. Eur J Ophthalmol 30(6):1506\u20131511. https:\/\/doi.org\/10.1177\/112067212095","journal-title":"Eur J Ophthalmol"},{"issue":"4","key":"2551_CR9","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1111\/j.1444-0938.2012.00724.x","volume":"95","author":"E Kim","year":"2012","unstructured":"Kim E, Ehrmann K (2012) Assessment of accuracy and repeatability of anterior segment optical coherence tomography and reproducibility of measurements using a customised software program. Clin Exp Optom 95(4):432\u2013441. https:\/\/doi.org\/10.1111\/j.1444-0938.2012.00724.x","journal-title":"Clin Exp Optom"}],"container-title":["International Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-022-02551-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10792-022-02551-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-022-02551-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,6]],"date-time":"2024-10-06T20:25:12Z","timestamp":1728246312000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10792-022-02551-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,29]]},"references-count":9,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2023,5]]}},"alternative-id":["2551"],"URL":"https:\/\/doi.org\/10.1007\/s10792-022-02551-8","relation":{},"ISSN":["1573-2630"],"issn-type":[{"value":"1573-2630","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,29]]},"assertion":[{"value":"15 April 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 October 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 October 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no conflicts of interests to disclose.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was performed in line with the principles of the Declaration of Helsinki. Approval was granted by the Ethics Committee of et al. Kindy College of Medicine University of Baghdad. Informed consent was obtained from all individual participants included in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}