{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,26]],"date-time":"2026-01-26T02:05:51Z","timestamp":1769393151435,"version":"3.49.0"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2023,3,17]],"date-time":"2023-03-17T00:00:00Z","timestamp":1679011200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,3,17]],"date-time":"2023-03-17T00:00:00Z","timestamp":1679011200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int Ophthalmol"],"DOI":"10.1007\/s10792-023-02694-2","type":"journal-article","created":{"date-parts":[[2023,3,27]],"date-time":"2023-03-27T01:00:39Z","timestamp":1679878839000},"page":"2917-2924","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Effectiveness of toric IOL and capsular tension ring suturing technique for rotational stability in eyes with long axial length"],"prefix":"10.1007","volume":"43","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7980-7311","authenticated-orcid":false,"given":"Fikret","family":"Ucar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Banu","family":"Turgut Ozturk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,3,17]]},"reference":[{"key":"2694_CR1","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1016\/j.ophtha.2015.10.002","volume":"123","author":"L Kessel","year":"2016","unstructured":"Kessel L, Andresen J, Tendal B et al (2016) Toric intraocular lenses in the correction of astigmatism during cataract surgery: a systematic review and meta-analysis. Ophthalmology 123:275\u2013286","journal-title":"Ophthalmology"},{"key":"2694_CR2","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1016\/j.jcrs.2016.11.044","volume":"43","author":"JF Alfonso","year":"2017","unstructured":"Alfonso JF, Lisa C, Fern\u00e1ndez-Vega Cueto L, Poo-L\u00f3pez A, Madrid-Costa D, Fern\u00e1ndez-Vega L (2017) Sequential intrastromal corneal ring segment and monofocal intraocular lens implantation for keratoconus and cataract: long-term follow-up. J Cataract Refract Surg 43:246\u2013254","journal-title":"J Cataract Refract Surg"},{"issue":"48","key":"2694_CR3","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1097\/j.jcrs.0000000000000774","volume":"1","author":"F D'Oria","year":"2022","unstructured":"D\u2019Oria F, Alio JL, Martinez-Abad A, Izquierdo L Jr, Larco P Jr, Abdelghany AA (2022) Astigmatic change as a predictor of intrastromal corneal ring segment late extrusion. J Cataract Refract Surg 1(48):401\u2013407","journal-title":"J Cataract Refract Surg"},{"key":"2694_CR4","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1016\/j.ajo.2020.09.041","volume":"222","author":"F D'Oria","year":"2021","unstructured":"D\u2019Oria F, Abdelghany AA, Ledo N, Barraquer RI, Alio JL (2021) Incidence and reasons for intrastromal corneal ring segment explantation. Am J Ophthalmol 222:351\u2013358","journal-title":"Am J Ophthalmol"},{"issue":"11","key":"2694_CR5","doi-asserted-by":"publisher","first-page":"15099","DOI":"10.1038\/s41598-021-94293-3","volume":"23","author":"R Takaku","year":"2021","unstructured":"Takaku R, Nakano S, Iida M et al (2021) Influence of frosted haptics on rotational stability of toric intraocular lenses. Sci Rep 23(11):15099","journal-title":"Sci Rep"},{"key":"2694_CR6","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1097\/00055735-200002000-00007","volume":"11","author":"C Novis","year":"2000","unstructured":"Novis C (2000) Astigmatism and toric intraocular lenses. Curr Opin Ophthalmol 11:47\u201350","journal-title":"Curr Opin Ophthalmol"},{"issue":"14","key":"2694_CR7","doi-asserted-by":"publisher","first-page":"4379","DOI":"10.2147\/OPTH.S285818","volume":"16","author":"BA Kramer","year":"2020","unstructured":"Kramer BA, Hardten DR, Berdahl JP (2020) Rotation characteristics of three toric monofocal intraocular lenses. Clin Ophthalmol 16(14):4379\u20134384","journal-title":"Clin Ophthalmol"},{"key":"2694_CR8","doi-asserted-by":"publisher","first-page":"1098","DOI":"10.1016\/j.jcrs.2015.04.004","volume":"41","author":"O Sagiv","year":"2015","unstructured":"Sagiv O, Sachs D (2015) Rotation stability of a toric intraocular lens with a second capsular tension ring. J Cataract Refract Surg 41:1098\u20131099","journal-title":"J Cataract Refract Surg"},{"key":"2694_CR9","first-page":"1","volume":"6","author":"F Ucar","year":"2021","unstructured":"Ucar F, Ozcimen M (2021) Can toric IOL rotation be minimized? Toric IOL-capsular tension ring suturing technique and its clinical outcomes. Semin Ophthalmol 6:1\u20136","journal-title":"Semin Ophthalmol"},{"issue":"47","key":"2694_CR10","doi-asserted-by":"publisher","first-page":"1473","DOI":"10.1097\/j.jcrs.0000000000000664","volume":"1","author":"Y Yao","year":"2021","unstructured":"Yao Y, Lu Q, Wei L et al (2021) Efficacy and complications of cataract surgery in high myopia. J Cataract Refract Surg 1(47):1473\u20131480. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000664","journal-title":"J Cataract Refract Surg"},{"key":"2694_CR11","doi-asserted-by":"publisher","first-page":"474","DOI":"10.1038\/s41433-019-0521-0","volume":"34","author":"S Li","year":"2020","unstructured":"Li S, Li X, He S et al (2020) Early postoperative rotational stability and its related factors of a single-piece acrylic toric intraocular lens. Eye (Lond) 34:474\u2013479","journal-title":"Eye (Lond)"},{"key":"2694_CR12","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.jcrs.2011.08.028","volume":"38","author":"GD Shah","year":"2012","unstructured":"Shah GD, Praveen MR, Vasavada AR et al (2012) Rotational stability of a toric intraocular lens: influence of axial length and alignment in the capsular bag. J Cataract Refract Surg 38:54\u201359","journal-title":"J Cataract Refract Surg"},{"key":"2694_CR13","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1136\/bjophthalmol-2015-306656","volume":"100","author":"X Zhu","year":"2016","unstructured":"Zhu X, He W, Zhang K et al (2016) Factors influencing 1-year rotational stability of AcrySof Toric intraocular lenses. Br J Ophthalmol 100:263\u2013268","journal-title":"Br J Ophthalmol"},{"key":"2694_CR14","doi-asserted-by":"publisher","first-page":"25","DOI":"10.3892\/etm.2020.9153","volume":"20","author":"JJ Yang","year":"2020","unstructured":"Yang JJ, Qin YZ, Qin L et al (2020) Comparison of the clinical efficacy of AcrySof\u00ae IQ and TECNIS\u00ae Toric intraocular lenses: a real-world study. Exp Ther Med 20:25","journal-title":"Exp Ther Med"},{"key":"2694_CR15","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1016\/j.jcrs.2008.09.027","volume":"35","author":"T Ferrer-Blasco","year":"2009","unstructured":"Ferrer-Blasco T, Mont\u00e9s-Mic\u00f3 R, Peixoto-de-Matos SC et al (2009) Prevalence of corneal astigmatism before cataract surgery. J Cataract Refract Surg 35:70\u201375","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"2694_CR16","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1186\/1471-2415-12-41","volume":"15","author":"B Agresta","year":"2012","unstructured":"Agresta B, Knorz MC, Donatti C et al (2012) Visual acuity improvements after implantation of toric intraocular lenses in cataract patients with astigmatism: a systematic review. BMC Ophthalmol 15(12):41","journal-title":"BMC Ophthalmol"},{"key":"2694_CR17","doi-asserted-by":"publisher","first-page":"1842","DOI":"10.1016\/j.jcrs.2008.07.012","volume":"34","author":"DF Chang","year":"2008","unstructured":"Chang DF (2008) Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses. J Cataract Refract Surg 34:1842\u20131847","journal-title":"J Cataract Refract Surg"},{"issue":"20","key":"2694_CR18","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1186\/s12886-020-01465-2","volume":"25","author":"S He","year":"2020","unstructured":"He S, Chen X, Wu X et al (2020) Early-stage clinical outcomes and rotational stability of TECNIS toric intraocular lens implantation in cataract cases with long axial length. BMC Ophthalmol 25(20):204","journal-title":"BMC Ophthalmol"},{"key":"2694_CR19","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1080\/08820538.2016.1247181","volume":"33","author":"Y Zhao","year":"2018","unstructured":"Zhao Y, Li J, Yang K et al (2018) Combined special capsular tension ring and toric IOL implantation for management of astigmatism and high axial myopia with cataracts. Semin Ophthalmol 33:389\u2013394","journal-title":"Semin Ophthalmol"},{"key":"2694_CR20","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1016\/S0886-3350(98)80329-5","volume":"24","author":"SJ Lim","year":"1998","unstructured":"Lim SJ, Kang SJ, Kim HB et al (1998) Analysis of zonular-free zone and lens size in relation to axial length of eye with age. J Cataract Refract Surg 24:390\u2013396","journal-title":"J Cataract Refract Surg"},{"key":"2694_CR21","doi-asserted-by":"publisher","first-page":"411","DOI":"10.4103\/ijo.IJO_875_17","volume":"66","author":"A Rastogi","year":"2018","unstructured":"Rastogi A, Khanam S, Goel Y et al (2018) Comparative evaluation of rotational stability and visual outcome of toric intraocular lenses with and without a capsular tension ring. Indian J Ophthalmol 66:411\u2013415","journal-title":"Indian J Ophthalmol"},{"issue":"14","key":"2694_CR22","doi-asserted-by":"publisher","first-page":"378","DOI":"10.18240\/ijo.2021.03.07","volume":"18","author":"HM Jiang","year":"2021","unstructured":"Jiang HM, Liang K, Tao LM (2021) Comparative evaluation of rotational stability of toric iols with four-eyelet vs two-eyelet capsular tension rings in eyes with high myopia. Int J Ophthalmol 18(14):378\u2013382","journal-title":"Int J Ophthalmol"},{"issue":"15","key":"2694_CR23","doi-asserted-by":"publisher","first-page":"e0228999","DOI":"10.1371\/journal.pone.0228999","volume":"24","author":"T Miyoshi","year":"2020","unstructured":"Miyoshi T, Fujie S, Yoshida H et al (2020) Effects of capsular tension ring on surgical outcomes of premium intraocular lens in patients with suspected zonular weakness. PLoS ONE 24(15):e0228999","journal-title":"PLoS ONE"},{"issue":"47","key":"2694_CR24","doi-asserted-by":"publisher","first-page":"618","DOI":"10.1097\/j.jcrs.0000000000000489","volume":"1","author":"K Sasaki","year":"2021","unstructured":"Sasaki K, Eguchi S, Miyata A et al (2021) Anterior capsule coverage and rotational stability of an acrylic toric intraocular lens. J Cataract Refract Surg 1(47):618\u2013621","journal-title":"J Cataract Refract Surg"},{"key":"2694_CR25","doi-asserted-by":"publisher","first-page":"1325","DOI":"10.1016\/j.ophtha.2018.02.012","volume":"125","author":"BS Lee","year":"2018","unstructured":"Lee BS, Chang DF (2018) Comparison of the rotational stability of two toric intraocular lenses in 1273 consecutive eyes. Ophthalmology 125:1325\u20131331","journal-title":"Ophthalmology"},{"key":"2694_CR26","doi-asserted-by":"crossref","first-page":"796","DOI":"10.1055\/s-0043-100656","volume":"234","author":"M Grohlich","year":"2017","unstructured":"Grohlich M, Mih\u00e1ltz K, Lasta M et al (2017) Evaluation of postoperative astigmatism correction and postoperative rotational stability of two toric \u0131ntraocular lenses. Klin Monbl Augenheilkd 234:796\u2013804 (German)","journal-title":"Klin Monbl Augenheilkd"}],"container-title":["International Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-023-02694-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10792-023-02694-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-023-02694-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,27]],"date-time":"2023-07-27T02:05:47Z","timestamp":1690423547000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10792-023-02694-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,17]]},"references-count":26,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2023,8]]}},"alternative-id":["2694"],"URL":"https:\/\/doi.org\/10.1007\/s10792-023-02694-2","relation":{},"ISSN":["1573-2630"],"issn-type":[{"value":"1573-2630","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,17]]},"assertion":[{"value":"4 October 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 March 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 March 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The author declares that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures were performed in accordance with the 1964 Helsinki. Declaration and its later amendments or comparable ethical standards. The study protocol was approved by the local ethics committee (KTO Karatay University, Faculty of Medicine Ethics Committee, Konya, T\u00fcrkiye). The study was conducted in accordance with the tenets of the Declaration of Helsinki.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"All participants gave written informed consent for their data to be published.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to Publication"}}]}}