{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,14]],"date-time":"2026-04-14T00:57:28Z","timestamp":1776128248340,"version":"3.50.1"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,6,21]],"date-time":"2024-06-21T00:00:00Z","timestamp":1718928000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,6,21]],"date-time":"2024-06-21T00:00:00Z","timestamp":1718928000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"Intramural grant of the Joint Shantou International Eye Center","award":["20-001"],"award-info":[{"award-number":["20-001"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int Ophthalmol"],"DOI":"10.1007\/s10792-024-03172-z","type":"journal-article","created":{"date-parts":[[2024,6,21]],"date-time":"2024-06-21T19:01:47Z","timestamp":1718996507000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Comparison of the effectiveness of different corneal curvature measurement methods for IOL implantation in traumatic aphakic eyes with corneal injury"],"prefix":"10.1007","volume":"44","author":[{"given":"Cuilian","family":"Li","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaolin","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xixuan","family":"Ke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yinglin","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qi","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xulong","family":"Liao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Honghe","family":"Xia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tingkun","family":"Shi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chuang","family":"Jin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuqiang","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haoyu","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,6,21]]},"reference":[{"issue":"1","key":"3172_CR1","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1016\/s0008-4182(06)80074-8","volume":"41","author":"M Thakker","year":"2006","unstructured":"Thakker M, Ray S (2006) Vision-limiting complications in open-globe injuries. Can J Ophthalmol 41(1):86\u201392. https:\/\/doi.org\/10.1016\/s0008-4182(06)80074-8","journal-title":"Can J Ophthalmol"},{"issue":"6","key":"3172_CR2","doi-asserted-by":"publisher","first-page":"820","DOI":"10.1016\/s0002-9394(14)71132-8","volume":"123","author":"D Pieramici","year":"1997","unstructured":"Pieramici D, Sternberg P, Aaberg T et al (1997) A system for classifying mechanical injuries of the eye (globe). The Ocular Trauma Classification Group. Am J Ophthalmol 123(6):820\u2013831. https:\/\/doi.org\/10.1016\/s0002-9394(14)71132-8","journal-title":"Am J Ophthalmol"},{"key":"3172_CR3","doi-asserted-by":"publisher","first-page":"32352","DOI":"10.1038\/srep32352","volume":"6","author":"K Zheng","year":"2016","unstructured":"Zheng K, Huang H, Peng K et al (2016) Change of optical intensity during healing process of corneal wound on anterior segment optical coherence tomography. Sci Rep 6:32352. https:\/\/doi.org\/10.1038\/srep32352","journal-title":"Sci Rep"},{"issue":"7","key":"3172_CR4","doi-asserted-by":"publisher","first-page":"982","DOI":"10.1080\/02713683.2016.1274038","volume":"42","author":"KK Zheng","year":"2017","unstructured":"Zheng KK, Cai J, Rong SS et al (2017) Longitudinal evaluation of wound healing after penetrating corneal injury: anterior segment optical coherence tomography study. Curr Eye Res 42(7):982\u2013986. https:\/\/doi.org\/10.1080\/02713683.2016.1274038","journal-title":"Curr Eye Res"},{"issue":"4","key":"3172_CR5","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/j.jcjo.2013.03.010","volume":"48","author":"M Shah","year":"2013","unstructured":"Shah M, Shah S, Upadhyay P et al (2013) Controversies in traumatic cataract classification and management: a review. Can J Ophthalmol 48(4):251\u2013258. https:\/\/doi.org\/10.1016\/j.jcjo.2013.03.010","journal-title":"Can J Ophthalmol"},{"issue":"12","key":"3172_CR6","doi-asserted-by":"publisher","first-page":"1446","DOI":"10.1016\/j.jcrs.2018.07.061","volume":"44","author":"P Sen","year":"2018","unstructured":"Sen P, Shah C, Sen A et al (2018) Primary versus secondary intraocular lens implantation in traumatic cataract after open-globe injury in pediatric patients. J Cataract Refract Surg 44(12):1446\u20131453. https:\/\/doi.org\/10.1016\/j.jcrs.2018.07.061","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"3172_CR7","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/s0161-6420(95)31073-1","volume":"102","author":"PE Rubsamen","year":"1995","unstructured":"Rubsamen PE, Irvin WD, McCuen BW 2nd et al (1995) Primary intraocular lens implantation in the setting of penetrating ocular trauma. Ophthalmology 102(1):101\u2013107. https:\/\/doi.org\/10.1016\/s0161-6420(95)31073-1","journal-title":"Ophthalmology"},{"issue":"4","key":"3172_CR8","doi-asserted-by":"publisher","first-page":"260","DOI":"10.3969\/j.issn.1003-5141.1999.04.020","volume":"19","author":"Z-C Liu","year":"1999","unstructured":"Liu Z-C, Luo C-T, Hao J (1999) Locatization, gradation and record of corneal foreign bodies. Recent Adv Ophthalmol 19(4):260\u2013261. https:\/\/doi.org\/10.3969\/j.issn.1003-5141.1999.04.020","journal-title":"Recent Adv Ophthalmol"},{"issue":"3","key":"3172_CR9","doi-asserted-by":"publisher","first-page":"1236","DOI":"10.1167\/iovs.05-0981","volume":"47","author":"K Schulze-Bonsel","year":"2006","unstructured":"Schulze-Bonsel K, Feltgen N, Burau H et al (2006) Visual acuities \u201chand motion\u201d and \u201ccounting fingers\u201d can be quantified with the freiburg visual acuity test. Invest Ophthalmol Vis Sci 47(3):1236\u20131240. https:\/\/doi.org\/10.1167\/iovs.05-0981","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"4","key":"3172_CR10","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1016\/S0886-3350(97)80205-2","volume":"23","author":"S Navon","year":"1997","unstructured":"Navon S (1997) Topography after repair of full-thickness corneal laceration. J Cataract Refract Surg 23(4):495\u2013501","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"3172_CR11","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1016\/S0002-9394(14)74785-3","volume":"113","author":"J Lamkin","year":"1992","unstructured":"Lamkin J, Azar D, Mead M et al (1992) Simultaneous corneal laceration repair, cataract removal, and posterior chamber intraocular lens implantation. Am J Ophthalmol 113(6):626\u2013631","journal-title":"Am J Ophthalmol"},{"issue":"1","key":"3172_CR12","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/S0161-6420(95)31073-1","volume":"102","author":"P Rubsamen","year":"1995","unstructured":"Rubsamen P, Irvin W, McCue B et al (1995) Primary intraocular lens implantation in the setting of penetrating ocular trauma. Ophthalmology 102(1):101\u2013107","journal-title":"Ophthalmology"},{"issue":"9","key":"3172_CR13","doi-asserted-by":"publisher","first-page":"1770","DOI":"10.1016\/S0161-6420(98)99052-2","volume":"105","author":"R Bowman","year":"1998","unstructured":"Bowman R, Yorston D, Wood M et al (1998) Primary intraocular lens implantation for penetrating lens trauma in Africa. Ophthalmology 105(9):1770\u20131774","journal-title":"Ophthalmology"},{"issue":"9","key":"3172_CR14","doi-asserted-by":"publisher","first-page":"1519","DOI":"10.1016\/s0886-3350(01)00872-0","volume":"27","author":"K Cohen","year":"2001","unstructured":"Cohen K (2001) Inaccuracy of intraocular lens power calculation after traumatic corneal laceration and cataract. J Cataract Refract Surg 27(9):1519\u20131522. https:\/\/doi.org\/10.1016\/s0886-3350(01)00872-0","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"3172_CR15","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1016\/s0008-4182(05)80005-5","volume":"40","author":"L Chuang","year":"2005","unstructured":"Chuang L, Lai C (2005) Secondary intraocular lens implantation of traumatic cataract in open-globe injury. Can J Ophthalmol 40(4):454\u2013459. https:\/\/doi.org\/10.1016\/s0008-4182(05)80005-5","journal-title":"Can J Ophthalmol"},{"key":"3172_CR16","doi-asserted-by":"publisher","first-page":"e0227638","DOI":"10.1371\/journal.pone.0227638","volume":"15","author":"K Se Young","year":"2020","unstructured":"Se Young K, Seung Hyun L, Na Rae K et al (2020) Accuracy of intraocular lens power calculation formulas using a swept-source optical biometer. PLoS ONE 15:e0227638. https:\/\/doi.org\/10.1371\/journal.pone.0227638","journal-title":"PLoS ONE"},{"key":"3172_CR17","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1177\/1120672119889016","volume":"31","author":"J Jiali","year":"2019","unstructured":"Jiali J, Yan L, Jing Z et al (2019) Comparison of six methods for the intraocular lens power calculation in high myopic eyes. Eur J Ophthalmol 31:96\u2013102. https:\/\/doi.org\/10.1177\/1120672119889016","journal-title":"Eur J Ophthalmol"},{"key":"3172_CR18","doi-asserted-by":"publisher","first-page":"1450","DOI":"10.1016\/j.jcrs.2016.07.021","volume":"42","author":"XK Jack","year":"2016","unstructured":"Jack XK, Anton VH, Alp A et al (2016) Intraocular lens power formula accuracy: comparison of 7 formulas. J Cataract Refract Surg 42:1450\u20131500. https:\/\/doi.org\/10.1016\/j.jcrs.2016.07.021","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"3172_CR19","doi-asserted-by":"publisher","first-page":"339","DOI":"10.3980\/j.issn.1672-5123.2020.2.35","volume":"20","author":"M Huo","year":"2020","unstructured":"Huo M, Du Z-J (2020) Effect of corneal suture tensions on the accuracy of intraocular lens power calculation in traumatic cataract. Int Eye Sci 20(2):339\u2013342. https:\/\/doi.org\/10.3980\/j.issn.1672-5123.2020.2.35","journal-title":"Int Eye Sci"},{"issue":"10","key":"3172_CR20","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1007\/s00347-003-0840-0","volume":"100","author":"F Weinand","year":"2003","unstructured":"Weinand F, Plag M, Pavlovic S (2003) Primary implantation of posterior chamber lenses after traumatic cataract peneration. Ophthalmologe 100(10):843\u2013846. https:\/\/doi.org\/10.1007\/s00347-003-0840-0","journal-title":"Ophthalmologe"}],"container-title":["International Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-024-03172-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10792-024-03172-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-024-03172-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,13]],"date-time":"2025-03-13T15:34:01Z","timestamp":1741880041000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10792-024-03172-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,21]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["3172"],"URL":"https:\/\/doi.org\/10.1007\/s10792-024-03172-z","relation":{},"ISSN":["1573-2630"],"issn-type":[{"value":"1573-2630","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,21]]},"assertion":[{"value":"26 September 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 June 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 June 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"The study was approved by the Ethics Committee Joint Shantou International Eye Center, Shantou University and the Chinese University of Hong Kong (JSIEC). The Declaration of Helsinki was followed. Because of the retrospective nature of the study, informed consent was waived by the Ethics Committee.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Patients and\/or the public were not involved in the design, or conduct, or reporting, or dissemination plans of this research.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Patient and public involvement"}}],"article-number":"248"}}