{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T08:45:25Z","timestamp":1790757925855,"version":"4.1.0"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,6,24]],"date-time":"2024-06-24T00:00:00Z","timestamp":1719187200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,6,24]],"date-time":"2024-06-24T00:00:00Z","timestamp":1719187200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004375","name":"Tel Aviv University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100004375","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>The purpose of this study was to investigate the visual and refractive outcomes in patients with pseudoexfoliation (PXF) undergoing routine cataract surgery and to compare the accuracy of intraocular lens (IOL) power calculation formulae.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Retrospective case-series study from Shamir medical center, a public hospital, Israel. Medical records of patients who underwent routine cataract surgery between January 2019 and August 2021 were investigated. Postoperative visual acuity and manifest refraction were examined. The error in predicted refraction and IOL power calculation accuracy within a range of\u2009\u00b1\u20090.50 to\u2009\u00b1\u20091.00 diopters were compared between different IOL calculating formulae.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>151 eyes of 151 patients ages 73.9\u2009\u00b1\u20097.1 years were included in this study- 58 eyes in the PXF group and 93 eyes in the control group. The mean absolute error (MAE) for the BUII formula was 0.63D\u2009\u00b1\u20090.87 for the PXF group and 0.36D\u2009\u00b1\u20090.48 for the control group (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.05). The MAE for the Hill-RBF 3.0 formula was 0.61D\u2009\u00b1\u20090.84 for the PXF group and 0.42D\u2009\u00b1\u20090.55 for the control group (<jats:italic>p<\/jats:italic>\u2009=\u20090.05). There were significant differences in MAE and MedAE between PXF group and control group measures (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.05). In the PXF group there were no significant differences between the different formulae.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>There were significant differences in accuracy of IOL power calculations in all formulae between PXF group and control group measures. PXF patients show hyperopic shift from predicted refraction. Barret universal II formula had the highest proportion of eyes with absolute error in prediction below or equal to 0.50 D in both PXF and control groups.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1007\/s10792-024-03195-6","type":"journal-article","created":{"date-parts":[[2024,6,24]],"date-time":"2024-06-24T04:01:38Z","timestamp":1719201698000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Accuracy of intra ocular lens calculation formulae in patients with pseudoexfoliation syndrome"],"prefix":"10.1007","volume":"44","author":[{"given":"Inbal","family":"Gazit","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Gershevich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adi","family":"Einan-Lifshitz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eran","family":"Pras","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Graham D.","family":"Barrett","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lior","family":"Or","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,6,24]]},"reference":[{"key":"3195_CR1","unstructured":"Lindberg JG (1917) Clinical studies of depigmentation of the pupillary margin and transillumination of the iris in cases of senile cataract and also in normal eyes of the aged. Thesis, Helsinki university, Finland"},{"key":"3195_CR2","doi-asserted-by":"publisher","first-page":"951","DOI":"10.1016\/S0161-6420(98)96020-1","volume":"105","author":"GOH Naumann","year":"1998","unstructured":"Naumann GOH, Schl\u00f6tzer-Schrehardt U, K\u00fcchle M (1998) Pseudoexfoliation syndrome for the comprehensive ophthalmologist; intraocular and systemic manifestations. Ophthalmology 105:951\u2013968. https:\/\/doi.org\/10.1016\/S0161-6420(98)96020-1","journal-title":"Ophthalmology"},{"key":"3195_CR3","doi-asserted-by":"publisher","first-page":"803","DOI":"10.1016\/s0161-6420(86)33664-9","volume":"93","author":"AM Prince","year":"1986","unstructured":"Prince AM, Ritch R (1986) Clinical signs of pseudoexfoliation syndrome. Ophthalmology 93:803\u2013807. https:\/\/doi.org\/10.1016\/s0161-6420(86)33664-9","journal-title":"Ophthalmology"},{"key":"3195_CR4","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1111\/j.1755-3768.1988.tb02628.x","volume":"184","author":"R Sampaolesi","year":"1988","unstructured":"Sampaolesi R, Zarate J, Croxato O (1988) The chamber angle in exfoliation syndrome. Clinical and pathologic findings. Acta Ophthalmol Suppl 184:48\u201353. https:\/\/doi.org\/10.1111\/j.1755-3768.1988.tb02628.x","journal-title":"Acta Ophthalmol Suppl"},{"key":"3195_CR5","doi-asserted-by":"publisher","first-page":"921","DOI":"10.1016\/j.ajo.2006.01.047","volume":"141","author":"U Schlotzer-Schrehardt","year":"2006","unstructured":"Schlotzer-Schrehardt U, Naumann GOH (2006) Ocular and systemic pseudoexfoliation syndrome [perspective]. Am J Ophthalmol 141:921\u2013937. https:\/\/doi.org\/10.1016\/j.ajo.2006.01.047","journal-title":"Am J Ophthalmol"},{"key":"3195_CR6","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1097\/00061198-199400320-00018","volume":"3","author":"R Ritch","year":"1994","unstructured":"Ritch R (1994) Exfoliation the most common identifiable cause of open-angle glaucoma. J Glaucoma 3:176\u2013178","journal-title":"J Glaucoma"},{"issue":"6","key":"3195_CR7","doi-asserted-by":"publisher","first-page":"1101","DOI":"10.1016\/j.jcrs.2009.03.011","volume":"35","author":"BJ Shingleton","year":"2009","unstructured":"Shingleton BJ, Crandall AS, Ahmed II (2009) Pseudoexfoliation and the cataract surgeon: preoperative, intraoperative, and postoperative issues related to intraocular pressure, cataract, and intraocular lenses. J Cataract Refract Surg 35(6):1101\u20131120. https:\/\/doi.org\/10.1016\/j.jcrs.2009.03.011","journal-title":"J Cataract Refract Surg"},{"key":"3195_CR8","doi-asserted-by":"publisher","first-page":"1080","DOI":"10.1001\/archopht.1982.01030040058007","volume":"100","author":"R Hiller","year":"1982","unstructured":"Hiller R, Sperduto RD, Krueger DE (1982) Pseudoexfoliation, intraocular pressure, and senile lens changes in a population-based survey. Arch Ophthalmol 100:1080\u20131082. https:\/\/doi.org\/10.1001\/archopht.1982.01030040058007","journal-title":"Arch Ophthalmol"},{"issue":"1","key":"3195_CR9","doi-asserted-by":"publisher","first-page":"19071","DOI":"10.1038\/s41598-021-98675-5","volume":"11","author":"A Wla\u017a","year":"2021","unstructured":"Wla\u017a A, Kustra A, Rozegna\u0142-Madej A, \u017barnowski T (2021) Intraocular lens power calculations in eyes with pseudoexfoliation syndrome. Sci Rep 11(1):19071. https:\/\/doi.org\/10.1038\/s41598-021-98675-5","journal-title":"Sci Rep"},{"key":"3195_CR10","unstructured":"Online Hill RBF 3.0 calculator: https:\/\/rbfcalculator.com\/online\/index.html."},{"issue":"8","key":"3195_CR11","doi-asserted-by":"publisher","first-page":"999","DOI":"10.1016\/j.jcrs.2017.08.003","volume":"43","author":"L Wang","year":"2017","unstructured":"Wang L, Koch DD, Hill W, Abulafia A (2017) Pursuing perfection in intraocular lens calculations III criteria for analyzing outcomes. J Cataract Refract Surg 43(8):999\u20131002","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"3195_CR12","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1097\/j.jcrs.0000000000000370","volume":"47","author":"JT Holladay","year":"2021","unstructured":"Holladay JT, Wilcox RR, Koch DD, Wang L (2021) Review and recommendations for univariate statistical analysis of spherical equivalent prediction error for IOL power calculations. J Cataract Refract Surg 47(1):65\u201377","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"3195_CR13","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1016\/j.jcrs.2013.02.023","volume":"39","author":"N Ishikawa","year":"2013","unstructured":"Ishikawa N, Hayashi Y, Miyamoto T, Saika S (2013) Errors in the prediction of postoperative refraction following intraocular lens implantation in eyes with pseudoexfoliation syndrome. J Cataract Refract Surg 39(4):649\u2013650. https:\/\/doi.org\/10.1016\/j.jcrs.2013.02.023","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"3195_CR14","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1016\/j.jcrs.2017.12.024","volume":"44","author":"N Manoharan","year":"2018","unstructured":"Manoharan N, Patnaik JL, Bonnell LN, SooHoo JR, Pantcheva MB, Kahook MY, Wagner BD, Lynch AM, Seibold LK (2018) Refractive outcomes of phacoemulsification cataract surgery in glaucoma patients. J Cataract Refract Surg 44(3):348\u2013354. https:\/\/doi.org\/10.1016\/j.jcrs.2017.12.024","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"3195_CR15","doi-asserted-by":"publisher","first-page":"616","DOI":"10.1111\/aos.14703","volume":"99","author":"IU Onur","year":"2021","unstructured":"Onur IU, K\u0131r\u0131k F, Yi\u011fit FU, Vural AD, Cavusoglu E, Evcimen Y (2021) Refractive precision in uncomplicated eyes with pseudoexfoliation: three-piece versus one-piece intraocular lens implantation. Acta Ophthalmol 99(6):616\u2013620. https:\/\/doi.org\/10.1111\/aos.14703","journal-title":"Acta Ophthalmol"},{"issue":"3","key":"3195_CR16","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1016\/j.jcrs.2007.10.031","volume":"34","author":"S Norrby","year":"2008","unstructured":"Norrby S (2008) Sources of error in intraocular lens power calculation. J Cataract Refract Surg 34(3):368\u2013376. https:\/\/doi.org\/10.1016\/j.jcrs.2007.10.031","journal-title":"J Cataract Refract Surg"},{"key":"3195_CR17","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/s0886-3350(13)80917-0","volume":"18","author":"T Olsen","year":"1992","unstructured":"Olsen T (1992) Sources of error in intraocular lens power calculation. J Cataract Refract 18:125\u2013129. https:\/\/doi.org\/10.1016\/s0886-3350(13)80917-0","journal-title":"J Cataract Refract"},{"key":"3195_CR18","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1016\/s0886-3350(13)80699-2","volume":"16","author":"P Erickson","year":"1990","unstructured":"Erickson P (1990) Effects of intraocular lens position errors on postoperative refractive error. J Cataract Refract Surg 16:305\u2013331. https:\/\/doi.org\/10.1016\/s0886-3350(13)80699-2","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"3195_CR19","doi-asserted-by":"publisher","first-page":"165","DOI":"10.4103\/jovr.jovr_81_15","volume":"12","author":"MR FallahTafti","year":"2017","unstructured":"FallahTafti MR, AbdollahBeiki H, Mohammadi SF, Latifi G, Ashrafi E, Fallah TZ (2017) Anterior chamber depth change following cataract surgery in pseudoexfoliation syndrome; a preliminary study. J Ophthalmic Vis Res 12(2):165\u2013169. https:\/\/doi.org\/10.4103\/jovr.jovr_81_15","journal-title":"J Ophthalmic Vis Res"},{"key":"3195_CR20","doi-asserted-by":"publisher","first-page":"255","DOI":"10.4274\/tjo.56659.","volume":"46","author":"SG G\u00fcng\u00f6r","year":"2016","unstructured":"G\u00fcng\u00f6r SG, Akman A, Asena L, Aksoy M, Sezen\u00f6z AS (2016) Changes in anterior chamber depth after phacoemulsification in pseudoexfoliative eyes and their effect on accuracy of intraocular lens power calculation. Turk J Ophthalmol 46:255\u2013258. https:\/\/doi.org\/10.4274\/tjo.56659.","journal-title":"Turk J Ophthalmol"},{"issue":"8","key":"3195_CR21","doi-asserted-by":"publisher","first-page":"894","DOI":"10.1097\/j.jcrs.0000000000000885","volume":"48","author":"I Kassos","year":"2022","unstructured":"Kassos I, Tzamalis A, Dermenoudi M, Matsou A, Koronis S, Ziakas N, Anastasopoulos E (2022) Ocular parameters changes following phacoemulsification in pseudoexfoliative eyes; a case-control study. J Cataract Refract Surg 48(8):894\u2013899. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000885","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"3195_CR22","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1097\/IJG.0000000000000093","volume":"25","author":"E Talay","year":"2016","unstructured":"Talay E, Tam\u00e7elik N, Bilgec MD (2016) Quadrantwise comparison of lens-iris distance in patients with pseudoexfoliation syndrome and age-matched controls. J Glaucoma 25(1):95\u2013100. https:\/\/doi.org\/10.1097\/IJG.0000000000000093","journal-title":"J Glaucoma"}],"container-title":["International Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-024-03195-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10792-024-03195-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-024-03195-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,13]],"date-time":"2025-03-13T15:49:58Z","timestamp":1741880998000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10792-024-03195-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,24]]},"references-count":22,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["3195"],"URL":"https:\/\/doi.org\/10.1007\/s10792-024-03195-6","relation":{},"ISSN":["1573-2630"],"issn-type":[{"value":"1573-2630","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,24]]},"assertion":[{"value":"11 April 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 June 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 June 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Graham D Barrett is the author of the BUII formulae and has licensed these to several manufacturers. All other authors All authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest (such as honoraria; educational grants; participation in speaker\u2019s bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licensing arrangements), or non-financial interest (such as personal or professional relationships, affiliations, knowledge or beliefs) in the subject matter or materials discussed in this manuscript.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the Shamir Medical Center Institutional Review Board and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. The study was approved by the Shamir Medical Center Institutional Review Board.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}],"article-number":"261"}}