{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T07:36:24Z","timestamp":1782459384410,"version":"3.54.5"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,6,21]],"date-time":"2024-06-21T00:00:00Z","timestamp":1718928000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,6,21]],"date-time":"2024-06-21T00:00:00Z","timestamp":1718928000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"Natural Science Foundation Project of Zhejiang Province","award":["LWY20H120001"],"award-info":[{"award-number":["LWY20H120001"]}]},{"name":"Medical and Health Project of Major Scientific and Technological Innovation of Wenzhou City","award":["ZY2019012"],"award-info":[{"award-number":["ZY2019012"]}]},{"name":"Health Science and Technology Project of Zhejiang Province","award":["2022PY073"],"award-info":[{"award-number":["2022PY073"]}]},{"name":"General Project of Education Department of Zhejiang Province","award":["Y201738690"],"award-info":[{"award-number":["Y201738690"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int Ophthalmol"],"DOI":"10.1007\/s10792-024-03227-1","type":"journal-article","created":{"date-parts":[[2024,6,21]],"date-time":"2024-06-21T09:02:27Z","timestamp":1718960547000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Comparing the accuracy of intraocular lens power calculation formulas using artificial intelligence and traditional formulas in highly myopic patients: a meta-analysis"],"prefix":"10.1007","volume":"44","author":[{"given":"Yuxu","family":"Hao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin","family":"Fu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ding","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,6,21]]},"reference":[{"key":"3227_CR1","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1097\/ICU.0000000000000217","volume":"27","author":"EW Chong","year":"2016","unstructured":"Chong EW, Mehta JS (2016) High myopia and cataract surgery. Curr Opin Ophthalmol 27:45\u201350. https:\/\/doi.org\/10.1097\/ICU.0000000000000217","journal-title":"Curr Opin Ophthalmol"},{"key":"3227_CR2","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1016\/j.ophtha.2010.01.020","volume":"117","author":"HH Liu","year":"2010","unstructured":"Liu HH, Xu L, Wang YX et al (2010) Prevalence and progression of myopic retinopathy in Chinese Adults: the Beijing Eye Study. Ophthalmology 117:1763\u20131768. https:\/\/doi.org\/10.1016\/j.ophtha.2010.01.020","journal-title":"Ophthalmology"},{"key":"3227_CR3","doi-asserted-by":"publisher","first-page":"2374","DOI":"10.3390\/jcm11092374","volume":"11","author":"L-H Tsai","year":"2022","unstructured":"Tsai L-H, Chen C-C, Lin C-J et al (2022) Risk factor analysis of early-onset cataracts in Taiwan. JCM 11:2374. https:\/\/doi.org\/10.3390\/jcm11092374","journal-title":"JCM"},{"key":"3227_CR4","doi-asserted-by":"publisher","unstructured":"Lee AC, Qazi MA, Pepose JS (2008) Biometry and intraocular lens power calculation. Curr Opin Ophthalmol 19:13\u201317. https:\/\/doi.org\/10.1097\/ICU.0b013e3282f1c5ad","DOI":"10.1097\/ICU.0b013e3282f1c5ad"},{"key":"3227_CR5","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1007\/s10792-022-02466-4","volume":"43","author":"H Li","year":"2022","unstructured":"Li H, Ye Z, Luo Y, Li Z (2022) Comparing the accuracy of the new-generation intraocular lens power calculation formulae in axial myopic eyes: a meta-analysis. Int Ophthalmol 43:619\u2013633. https:\/\/doi.org\/10.1007\/s10792-022-02466-4","journal-title":"Int Ophthalmol"},{"key":"3227_CR6","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1136\/bjo.68.4.235","volume":"68","author":"JL Menezo","year":"1984","unstructured":"Menezo JL, Chaques V, Harto M (1984) The SRK regression formula in calculating the dioptric power of intraocular lenses. Br J Ophthalmol 68:235\u2013237. https:\/\/doi.org\/10.1136\/bjo.68.4.235","journal-title":"Br J Ophthalmol"},{"key":"3227_CR7","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/S0886-3350(88)80087-7","volume":"14","author":"DR Sanders","year":"1988","unstructured":"Sanders DR, Retzlaff J, Kraff MC (1988) Comparison of the SRK II\u2122 formula and other second generation formulas. J Cataract Refract Surg 14:136\u2013141. https:\/\/doi.org\/10.1016\/S0886-3350(88)80087-7","journal-title":"J Cataract Refract Surg"},{"key":"3227_CR8","doi-asserted-by":"publisher","first-page":"700","DOI":"10.1016\/S0886-3350(13)80338-0","volume":"19","author":"KJ Hoffer","year":"1993","unstructured":"Hoffer KJ (1993) The Hoffer Q formula: a comparison of theoretic and regression formulas. J Cataract Refract Surg 19:700\u2013712. https:\/\/doi.org\/10.1016\/S0886-3350(13)80338-0","journal-title":"J Cataract Refract Surg"},{"key":"3227_CR9","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1016\/j.jcrs.2018.07.053","volume":"44","author":"M Amro","year":"2018","unstructured":"Amro M, Chanbour W, Arej N, Jarade E (2018) Third- and fourth-generation formulas for intraocular lens power calculation before and after phakic intraocular lens insertion in high myopia. J Cataract Refract Surg 44:1321\u20131325. https:\/\/doi.org\/10.1016\/j.jcrs.2018.07.053","journal-title":"J Cataract Refract Surg"},{"key":"3227_CR10","doi-asserted-by":"publisher","first-page":"1553","DOI":"10.21037\/atm-20-2290","volume":"8","author":"G Savini","year":"2020","unstructured":"Savini G, Taroni L, Hoffer KJ (2020) Recent developments in intraocular lens power calculation methods-update 2020. Ann Transl Med 8:1553. https:\/\/doi.org\/10.21037\/atm-20-2290","journal-title":"Ann Transl Med"},{"key":"3227_CR11","doi-asserted-by":"publisher","first-page":"5947","DOI":"10.3390\/jcm11195947","volume":"11","author":"M Moshirfar","year":"2022","unstructured":"Moshirfar M, Durnford KM, Jensen JL et al (2022) Accuracy of six intraocular lens power calculations in eyes with axial lengths greater than 28.0\u00a0mm. JCM 11:5947. https:\/\/doi.org\/10.3390\/jcm11195947","journal-title":"JCM"},{"key":"3227_CR12","doi-asserted-by":"publisher","first-page":"1173","DOI":"10.5455\/JPMA.15406","volume":"70","author":"A Yildiz","year":"2020","unstructured":"Yildiz A (2020) The comparison of the intraocular lens power calculation formulas in long eyes. J Pak Med Assoc 70:1173\u20131176. https:\/\/doi.org\/10.5455\/JPMA.15406","journal-title":"J Pak Med Assoc"},{"key":"3227_CR13","doi-asserted-by":"publisher","first-page":"207","DOI":"10.3928\/1081597X-20201123-01","volume":"37","author":"J Bernardes","year":"2021","unstructured":"Bernardes J, Raimundo M, Lobo C, Murta JN (2021) A comparison of intraocular lens power calculation formulas in high myopia. J Refract Surg 37:207","journal-title":"J Refract Surg"},{"key":"3227_CR14","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1016\/j.ajo.2020.09.019","volume":"223","author":"H Cheng","year":"2021","unstructured":"Cheng H, Wang L, Kane JX et al (2021) Accuracy of artificial intelligence formulas and axial length adjustments for highly myopic eyes. Am J Ophthalmol 223:100\u2013107. https:\/\/doi.org\/10.1016\/j.ajo.2020.09.019","journal-title":"Am J Ophthalmol"},{"key":"3227_CR15","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1177\/1120672119889016","volume":"31","author":"J Ji","year":"2019","unstructured":"Ji J, Liu Y, Zhang J et al (2019) Comparison of six methods for the intraocular lens power calculation in high myopic eyes. Eur J Ophthalmol 31:96\u2013102. https:\/\/doi.org\/10.1177\/1120672119889016","journal-title":"Eur J Ophthalmol"},{"key":"3227_CR16","doi-asserted-by":"publisher","first-page":"754","DOI":"10.3928\/1081597X-20210712-08","volume":"37","author":"L Lin","year":"2021","unstructured":"Lin L, Xu M, Gu S et al (2021) Accuracy of newer generation IOL power calculation formulas in eyes with high axial myopia. J Refract Surg 37:754","journal-title":"J Refract Surg"},{"key":"3227_CR17","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1016\/j.jcrs.2019.01.018","volume":"45","author":"J Liu","year":"2019","unstructured":"Liu J (2019) Comparison of intraocular lens power calculation formulas in Chinese eyes with axial myopia. J Cataract Refract Surg 45:725","journal-title":"J Cataract Refract Surg"},{"key":"3227_CR18","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/j.ajo.2021.07.017","volume":"233","author":"E Mo","year":"2022","unstructured":"Mo E, Lin L, Wang J et al (2022) Clinical accuracy of 6 intraocular lens power calculation formulas in elongated eyes, according to anterior chamber depth. Am J Ophthalmol 233:153\u2013162. https:\/\/doi.org\/10.1016\/j.ajo.2021.07.017","journal-title":"Am J Ophthalmol"},{"key":"3227_CR19","doi-asserted-by":"publisher","first-page":"4848","DOI":"10.3390\/jcm11164848","volume":"11","author":"M Omoto","year":"2022","unstructured":"Omoto M, Sugawara K, Torii H et al (2022) Investigating the prediction accuracy of recently updated intraocular lens power formulas with artificial intelligence for high myopia. J Clin Med 11:4848. https:\/\/doi.org\/10.3390\/jcm11164848","journal-title":"J Clin Med"},{"key":"3227_CR20","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-023-06060-x","author":"O Voytsekhivskyy","year":"2023","unstructured":"Voytsekhivskyy O, Tutchenko L (2023) Comparison of the prediction accuracy of 13 formulas in long eyes. Graefes Arch Clin Exp Ophthalmol. https:\/\/doi.org\/10.1007\/s00417-023-06060-x","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"3227_CR21","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1186\/s40662-022-00293-3","volume":"9","author":"L Wei","year":"2022","unstructured":"Wei L, Cheng K, He W et al (2022) Application of total keratometry in ten intraocular lens power calculation formulas in highly myopic eyes. Eye Vis (Lond) 9:21. https:\/\/doi.org\/10.1186\/s40662-022-00293-3","journal-title":"Eye Vis (Lond)"},{"key":"3227_CR22","doi-asserted-by":"publisher","first-page":"e000251","DOI":"10.1136\/bmjophth-2018-000251","volume":"4","author":"BJ Connell","year":"2019","unstructured":"Connell BJ, Kane JX (2019) Comparison of the Kane formula with existing formulas for intraocular lens power selection. BMJ Open Ophth 4:e000251. https:\/\/doi.org\/10.1136\/bmjophth-2018-000251","journal-title":"BMJ Open Ophth"},{"key":"3227_CR23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2019\/8913582","volume":"2019","author":"YW Chung","year":"2019","unstructured":"Chung YW, Choi MY, Kim J, Kwon J (2019) The Association between macular thickness and axial length in myopic eyes. Biomed Res Int 2019:1\u20137. https:\/\/doi.org\/10.1155\/2019\/8913582","journal-title":"Biomed Res Int"},{"key":"3227_CR24","doi-asserted-by":"publisher","first-page":"13","DOI":"10.4103\/1110-9173.201623","volume":"18","author":"S Gaballa","year":"2017","unstructured":"Gaballa S, RihamSHM A, Abouhussein N, Raafat K (2017) IOL master and A-scan biometry in axial length and intraocular lens power measurements. Delta J Ophthalmol 18:13. https:\/\/doi.org\/10.4103\/1110-9173.201623","journal-title":"Delta J Ophthalmol"},{"key":"3227_CR25","doi-asserted-by":"publisher","first-page":"2881","DOI":"10.1007\/s40123-023-00799-6","volume":"12","author":"W Stopyra","year":"2023","unstructured":"Stopyra W, Langenbucher A, Grzybowski A (2023) Intraocular lens power calculation formulas-a systematic review. Ophthalmol Ther 12:2881\u20132902. https:\/\/doi.org\/10.1007\/s40123-023-00799-6","journal-title":"Ophthalmol Ther"},{"key":"3227_CR26","first-page":"2","volume":"46","author":"K Darcy","year":"2020","unstructured":"Darcy K, Gunn D, Tavassoli S et al (2020) Assessment of the accuracy of new and updated intraocular lens power calculation formulas in 10 930 eyes from the UK National Health Service. J Cataract Refract Surg 46:2\u20137","journal-title":"J Cataract Refract Surg"},{"key":"3227_CR27","doi-asserted-by":"publisher","first-page":"498","DOI":"10.3390\/jcm13020498","volume":"13","author":"W Stopyra","year":"2024","unstructured":"Stopyra W, Cooke DL, Grzybowski A (2024) A review of intraocular lens power calculation formulas based on artificial intelligence. JCM 13:498. https:\/\/doi.org\/10.3390\/jcm13020498","journal-title":"JCM"},{"key":"3227_CR28","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1097\/j.jcrs.0000000000000702","volume":"48","author":"M Tsessler","year":"2022","unstructured":"Tsessler M, Cohen S, Wang L et al (2022) Evaluating the prediction accuracy of the Hill-RBF 3.0 formula using a heteroscedastic statistical method. J Cataract Refract Surg 48:37\u201343. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000702","journal-title":"J Cataract Refract Surg"},{"key":"3227_CR29","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1167\/iovs.03-1051","volume":"45","author":"M He","year":"2004","unstructured":"He M, Zeng J, Liu Y et al (2004) Refractive error and visual impairment in urban children in southern china. Invest Ophthalmol Vis Sci 45:793\u2013799. https:\/\/doi.org\/10.1167\/iovs.03-1051","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"3227_CR30","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1007\/s11121-013-0377-7","volume":"14","author":"M Borenstein","year":"2013","unstructured":"Borenstein M, Higgins JPT (2013) Meta-analysis and subgroups. Prev Sci 14:134\u2013143. https:\/\/doi.org\/10.1007\/s11121-013-0377-7","journal-title":"Prev Sci"}],"container-title":["International Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-024-03227-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10792-024-03227-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-024-03227-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,13]],"date-time":"2025-03-13T15:45:58Z","timestamp":1741880758000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10792-024-03227-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,21]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["3227"],"URL":"https:\/\/doi.org\/10.1007\/s10792-024-03227-1","relation":{},"ISSN":["1573-2630"],"issn-type":[{"value":"1573-2630","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,21]]},"assertion":[{"value":"21 December 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 June 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 June 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no competing interests to declare that are relevant to the content of this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}],"article-number":"242"}}