{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T15:34:22Z","timestamp":1784820862790,"version":"3.55.0"},"reference-count":69,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T00:00:00Z","timestamp":1749168000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T00:00:00Z","timestamp":1749168000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int Ophthalmol"],"DOI":"10.1007\/s10792-025-03598-z","type":"journal-article","created":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T03:07:49Z","timestamp":1749179269000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Comparison of intraocular pressure measurements obtained by Goldmann applanation tonometer, corvis ST and a conventional non-contact airpuff tonometer in eyes with previous myopic refractive surgery and correlation with corneal biomechanical parameters"],"prefix":"10.1007","volume":"45","author":[{"given":"Efthymios","family":"Karmiris","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anastasia","family":"Tsiogka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Panagiotis","family":"Stavrakas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Konstantinos","family":"Tsiripidis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Evangelia","family":"Papakonstantinou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Evangelia","family":"Chalkiadaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,6,6]]},"reference":[{"key":"3598_CR1","doi-asserted-by":"crossref","unstructured":"Cook JA, et al. Surveillance of ocular hypertension study G. systematic review of the agreement of tonometers with Goldmann applanation tonometry. Ophthalmology. 2012; 119(8): 1552\u20137","DOI":"10.1016\/j.ophtha.2012.02.030"},{"issue":"5","key":"3598_CR2","doi-asserted-by":"publisher","first-page":"931","DOI":"10.1038\/S41433-018-0040-4","volume":"32","author":"K Aziz","year":"2018","unstructured":"Aziz K, Friedman DS (2018) Tonometers - which one should I use? Eye 32(5):931\u2013937. https:\/\/doi.org\/10.1038\/S41433-018-0040-4","journal-title":"Eye"},{"issue":"1","key":"3598_CR3","doi-asserted-by":"crossref","first-page":"E16","DOI":"10.1097\/OPX.0b013e318205a4e7","volume":"88","author":"RL Stamper","year":"2011","unstructured":"Stamper RL (2011) A history of intraocular pressure and its measurement. Optom Vis Sci 88(1):E16-28","journal-title":"Optom Vis Sci"},{"issue":"1","key":"3598_CR4","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.jcrs.2004.09.031","volume":"31","author":"J Liu","year":"2005","unstructured":"Liu J, Roberts CJ (2005) Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J Cataract Refract Surg 31(1):146\u2013155","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"3598_CR5","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/0039-6257(93)90053-A","volume":"38","author":"MM Whitacre","year":"1993","unstructured":"Whitacre MM, Stein R (1993) Sources of error with use of Goldmann-type tonometers. Surv Ophthalmol. 38(1):1\u201330","journal-title":"Surv Ophthalmol."},{"issue":"11","key":"3598_CR6","doi-asserted-by":"crossref","first-page":"815","DOI":"10.4103\/0301-4738.171956","volume":"63","author":"S Tejwani","year":"2015","unstructured":"Tejwani S et al (2015) A cross-sectional study to compare intraocular pressure measurement by sequential use of Goldman applanation tonometry, dynamic contour tonometry, ocular response analyzer, and Corvis ST. Indian J Ophthalmol 63(11):815\u2013820","journal-title":"Indian J Ophthalmol"},{"issue":"6","key":"3598_CR7","doi-asserted-by":"crossref","first-page":"936","DOI":"10.1177\/112067210901900607","volume":"19","author":"B Oncel","year":"2009","unstructured":"Oncel B et al (2009) Comparison of IOP measurement by ocular response analyzer, dynamic contour, Goldmann applanation, and noncontact tonometry. Eur J Ophthalmol 19(6):936\u2013941","journal-title":"Eur J Ophthalmol"},{"issue":"2","key":"3598_CR8","doi-asserted-by":"crossref","first-page":"43","DOI":"10.3921\/joptom.2008.43","volume":"1","author":"CGV De Moraes","year":"2010","unstructured":"De Moraes CGV et al (2010) Modalities of Tonometry and their Accuracy with Respect to Corneal Thickness and Irregularities. J Optom 1(2):43\u201349","journal-title":"J Optom"},{"issue":"6","key":"3598_CR9","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1159\/000310825","volume":"211","author":"G Cennamo","year":"1997","unstructured":"Cennamo G, Rosa N, La Rana A, Bianco S, Sebastiani A (1997) Non- contact tonometry in patients that underwent photorefractive keratectomy. Ophthalmologica 211(6):341\u2013343","journal-title":"Ophthalmologica"},{"issue":"2","key":"3598_CR10","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1167\/iovs.13-13172","volume":"55","author":"A Smedowski","year":"2014","unstructured":"Smedowski A et al (2014) Comparison of three intraocular pressure measurement methods including biomechanical properties of the cornea. Invest Ophthalmol Vis Sci 55(2):666\u2013673","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"2","key":"3598_CR11","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1007\/s00417-009-1202-7","volume":"248","author":"M Hagishima","year":"2010","unstructured":"Hagishima M et al (2010) Effect of corneal astigmatism on intraocular pressure measurement using ocular response analyzer and Goldmann applanation tonometer. Graefes Arch Clin Exp Ophthalmol 248(2):257\u2013262","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"3598_CR12","doi-asserted-by":"crossref","first-page":"829","DOI":"10.2147\/OPTH.S106836","volume":"10","author":"K Yaoeda","year":"2016","unstructured":"Yaoeda K et al (2016) Comparison of intraocular pressure adjusted by central corneal thickness or corneal biomechanical properties as measured in glaucomatous eyes using noncontact tonometers and the Goldmann applanation tonometer. Clin Ophthalmol 10:829\u2013834","journal-title":"Clin Ophthalmol"},{"key":"3598_CR13","doi-asserted-by":"crossref","first-page":"943","DOI":"10.1080\/10255842.2015.1077515","volume":"19","author":"AA Joda","year":"2016","unstructured":"Joda AA et al (2016) Development and validation of a correction equation for Corvis tonometry. Comput Methods Biomech Biomed Engin 19:943\u2013953","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"3598_CR14","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1016\/j.exer.2018.06.013","volume":"175","author":"A Eliasy","year":"2018","unstructured":"Eliasy A, Chen KJ, Vinciguerra R, Maklad O, Vinciguerra P, Ambr\u00f3sio R Jr et al (2018) Ex-vivo experimental validation of biomechanically-corrected intraocular pressure measurements on human eyes using the CorVis ST. Exp Eye Res 175:98\u2013102","journal-title":"Exp Eye Res"},{"key":"3598_CR15","doi-asserted-by":"crossref","DOI":"10.1016\/j.exer.2019.107904","volume":"191","author":"BA Nguyen","year":"2020","unstructured":"Nguyen BA, Reilly MA, Roberts CJ (2020) Biomechanical contribution of the sclera to dynamic corneal response in air-puff induced deformation in human donor eyes. Exp Eye Res 191:107904","journal-title":"Exp Eye Res"},{"issue":"12","key":"3598_CR16","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.1016\/j.jcrs.2017.08.019","volume":"43","author":"H Lee","year":"2017","unstructured":"Lee H, Roberts CJ, Kim TI, Ambr\u00f3sio R Jr, Elsheikh A, Yong Kang DS (2017) Changes in biomechanically corrected intraocular pressure and dynamic corneal response parameters before and after transepithelial photorefractive keratectomy and femtosecond laser-assisted laser in situ keratomileusis. J Cataract Refract Surg 43(12):1495\u20131503","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"3598_CR17","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1167\/tvst.12.5.24","volume":"12","author":"R Herber","year":"2023","unstructured":"Herber R, Vinciguerra R, Flockerzi E, Vinciguerra P, Seitz B (2023) Why the Corvis Biomechanical Factor Should Only Be Used for Corneal Ectasia. Transl Vis Sci Technol 12(5):24","journal-title":"Transl Vis Sci Technol"},{"key":"3598_CR18","doi-asserted-by":"crossref","first-page":"105","DOI":"10.3389\/fbioe.2019.00105","volume":"7","author":"A Eliasy","year":"2019","unstructured":"Eliasy A, Chen KJ, Vinciguerra R, Lopes BT, Abass A, Vinciguerra P, Ambr\u00f3sio R Jr, Roberts CJ, Elsheikh A (2019) Determination of Corneal Biomechanical Behavior in-vivo for Healthy Eyes Using CorVis ST Tonometry: Stress-Strain Index. Front Bioeng Biotechnol 7:105","journal-title":"Front Bioeng Biotechnol"},{"key":"3598_CR19","doi-asserted-by":"crossref","first-page":"468","DOI":"10.3928\/1081597X-20140521-01","volume":"30","author":"BF Valbon","year":"2014","unstructured":"Valbon BF, Ambr\u00f3sio R Jr, Fontes BM, Luz A, Roberts CJ, Alves MR (2014) Ocular biomechanical metrics by CorVis ST in healthy Brazilian patients. J Refract Surg 30:468\u2013473","journal-title":"J Refract Surg"},{"key":"3598_CR20","doi-asserted-by":"crossref","first-page":"808","DOI":"10.3928\/1081-597X-20071001-11","volume":"23","author":"A Elsheikh","year":"2007","unstructured":"Elsheikh A, Wang D, Pye D (2007) Determination of the modulus of elasticity of the human cornea. J Refract Surg 23:808\u2013818","journal-title":"J Refract Surg"},{"key":"3598_CR21","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0140385","volume":"10","author":"R Asaoka","year":"2015","unstructured":"Asaoka R, Nakakura S, Tabuchi H, Murata H, Nakao Y, Ihara N, Rimayanti U, Aihara M, Kiuchi Y (2015) The Relationship between Corvis ST Tonometry Measured Corneal Parameters and Intraocular Pressure, Corneal Thickness and Corneal Curvature. PLoS ONE 10:e0140385","journal-title":"PLoS ONE"},{"key":"3598_CR22","doi-asserted-by":"crossref","first-page":"803","DOI":"10.3928\/1081597X-20160629-01","volume":"32","author":"R Vinciguerra","year":"2016","unstructured":"Vinciguerra R, Ambr\u00f3sio R, Elsheikh A et al (2016) Detection of keratoconus with a new biomechanical index. J Refract Surg 32:803\u2013810","journal-title":"J Refract Surg"},{"key":"3598_CR23","doi-asserted-by":"crossref","first-page":"550","DOI":"10.3928\/1081597X-20160524-01","volume":"32","author":"R Vinciguerra","year":"2016","unstructured":"Vinciguerra R, Elsheikh A, Roberts CJ et al (2016) Influence of pachymetry and intraocular pressure on dynamic corneal response parameters in healthy patients. J Refract Surg 32:550\u2013561","journal-title":"J Refract Surg"},{"key":"3598_CR24","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1016\/j.ajo.2013.12.024","volume":"157","author":"T Huseynova","year":"2014","unstructured":"Huseynova T, Waring GO 4th, Roberts C, Krueger RR, Tomita M (2014) Corneal biomechanics as a function of intraocular pressure and pachymetry by dynamic infrared signal and Scheimpflug imag-ing analysis in normal eyes. Am J Ophthalmol 157:885\u2013893","journal-title":"Am J Ophthalmol"},{"issue":"3","key":"3598_CR25","first-page":"219","volume":"8","author":"M Moshirfar","year":"2019","unstructured":"Moshirfar M, Motlagh MN, Murri MS, Momeni-Moghaddam H, Ronquillo YC, Hoopes PC (2019) Advances in biomechanical parameters for screening of refractive surgery candidates: a review of the literature, part III. Med Hypothesis Discov Innov Ophthalmol 8(3):219\u2013240","journal-title":"Med Hypothesis Discov Innov Ophthalmol"},{"issue":"1","key":"3598_CR26","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1186\/s12938-019-0636-3","volume":"18","author":"M J\u0119dzierowska","year":"2019","unstructured":"J\u0119dzierowska M, Koprowski R (2019) Novel dynamic corneal response parameters in a practice use: a critical review. Biomed Eng Online 18(1):17","journal-title":"Biomed Eng Online"},{"key":"3598_CR27","doi-asserted-by":"crossref","first-page":"1268","DOI":"10.1001\/archopht.120.10.1268","volume":"120","author":"A Heijl","year":"2002","unstructured":"Heijl A, Leske MC, Bengtsson B, Hyman L, Bengtsson B, Hussein M et al (2002) Reduction of intraocular pressure and glaucoma progression: Results from the Early Manifest Glaucoma Trial. Arch Ophthalmol 120:1268\u20131279","journal-title":"Arch Ophthalmol"},{"key":"3598_CR28","doi-asserted-by":"crossref","unstructured":"The Advanced Glaucoma Intervention Study (AGIS): 7. The relationship between control of intraocular pressure and visual field deterioration. The AGIS Investigators. Am J Ophthalmol. 2000;130:429\u201340","DOI":"10.1016\/S0002-9394(00)00538-9"},{"key":"3598_CR29","doi-asserted-by":"crossref","unstructured":"Feiner L, Piltz-Seymour JR Collaborative Initial Glaucoma Treatment Study. Collaborative Initial Glaucoma Treatment Study: A summary of results to date. Curr Opin Ophthalmol. 2003;14:106\u201311","DOI":"10.1097\/00055735-200304000-00010"},{"issue":"2","key":"3598_CR30","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1159\/000310760","volume":"211","author":"E Chihara","year":"1997","unstructured":"Chihara E, Liu X, Dong J et al (1997) Severe myopia as a risk factor for progressive visual field loss in primary open glaucoma. Ophthalmologica 211(2):66\u201371","journal-title":"Ophthalmologica"},{"issue":"1","key":"3598_CR31","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1097\/00003226-200101000-00006","volume":"20","author":"HJ Garzozi","year":"2001","unstructured":"Garzozi HJ, Chung HS, Lang Y, Kagemann L, Harris A (2001) Intraocular pressure and photorefractive keratectomy: a comparison of three different tonometers. Cornea 20(1):33\u201336","journal-title":"Cornea"},{"issue":"2","key":"3598_CR32","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1007\/s00417-012-2142-1","volume":"251","author":"AL Sadigh","year":"2013","unstructured":"Sadigh AL, Fouladi RF, Hashemi H, Beheshtnejad AH (2013) A comparison between Goldmann applanation tonometry and dynamic contour tonometry after photorefractive keratectomy. Graefes Arch Clin Exp Ophthalmol 251(2):603\u2013608","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"3598_CR33","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1097\/ICU.0000000000000282","volume":"27","author":"CJ Roberts","year":"2016","unstructured":"Roberts CJ (2016) Importance of accurately assessing biomechanics of the cornea. Curr Opin Ophthalmol 27:285\u2013291","journal-title":"Curr Opin Ophthalmol"},{"issue":"6","key":"3598_CR34","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1016\/S0886-3350(99)00461-7","volume":"26","author":"I Schipper","year":"2000","unstructured":"Schipper I, Senn P, Oyo-Szerenyi K, Peter R (2000) Central and peripheral pressure measurements with the Goldmann tonometer and tono-pen after photorefractive keratectomy for myopia. J Cataract Refract Surg 26(6):929\u2013933","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"3598_CR35","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1016\/S0886-3350(99)80044-3","volume":"25","author":"Y Levy","year":"1999","unstructured":"Levy Y, Zadok D, Glovinsky Y, Krakowski D, Nemet P (1999) Tono-pen versus Goldmann tonometry after excimer laser photorefractive keratectomy. J Cataract Refract Surg 25(4):486\u2013491","journal-title":"J Cataract Refract Surg"},{"key":"3598_CR36","doi-asserted-by":"crossref","unstructured":"Abbasoglu OE, Bowman RW, Cavanagh HD, McCulley JP. Reliability of intraocular pressure measurements after myopic excimer photorefractive keratectomy. Ophthalmology. 1998;105(12):21 93\u20132196","DOI":"10.1016\/S0161-6420(98)91215-5"},{"issue":"10","key":"3598_CR37","doi-asserted-by":"crossref","first-page":"1344","DOI":"10.1016\/S0886-3350(99)00202-3","volume":"25","author":"D Zadok","year":"1999","unstructured":"Zadok D, Tran DB, Twa M, Carpenter M, Schanzlin DJ (1999) Pneumotonometry versus Goldmann tonometry after laser in situ keratomileusis for myopia. J Cataract Refract Surg 25(10):1344\u20131348","journal-title":"J Cataract Refract Surg"},{"key":"3598_CR38","doi-asserted-by":"crossref","first-page":"420","DOI":"10.3928\/1081-597X-20010701-03","volume":"17","author":"KM Rashad","year":"2001","unstructured":"Rashad KM, Bahnassy KM (2001) Changes in intraocular pressure after laser in situ keratomileusis. Refract Surg 17:420\u2013427","journal-title":"Refract Surg"},{"issue":"2","key":"3598_CR39","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/S0886-3350(00)00782-3","volume":"27","author":"HJ Park","year":"2001","unstructured":"Park HJ, Uhm KB, Hong C (2001) Reduction in intraocular pressure after laser in situ keratomileusis. J Cataract Refract Surg 27(2):303\u2013309","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"3598_CR40","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1016\/j.ophtha.2014.09.033","volume":"122","author":"JM Schallhorn","year":"2015","unstructured":"Schallhorn JM, Schallhorn SC, Ou Y (2015) Factors that influence intraocular pressure changes after myopic and hyperopic LASIK and photorefractive keratectomy: a large population study. Ophthalmology 122(3):471\u2013479","journal-title":"Ophthalmology"},{"issue":"7","key":"3598_CR41","doi-asserted-by":"crossref","first-page":"2987","DOI":"10.1167\/iovs.17-23474","volume":"59","author":"A Gogola","year":"2018","unstructured":"Gogola A, Jan N-J, Brazile B, Lam P, Lathrop KL, Chan KC, Sigal IA (2018) Spatial patterns and age-related changes of the collagen crimp in the human cornea and sclera. Invest Ophthalmol Vis Sci 59(7):2987\u20132998","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"1","key":"3598_CR42","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1080\/02713680601077145","volume":"32","author":"A Elsheikh","year":"2007","unstructured":"Elsheikh A, Wang D, Brown M, Rama P, Campanelli M, Pye D (2007) Assessment of corneal biomechanical properties and their variation with age. Curr Eye Res 32(1):11\u201319","journal-title":"Curr Eye Res"},{"issue":"5","key":"3598_CR43","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1016\/j.exer.2008.02.006","volume":"86","author":"A Elsheikh","year":"2008","unstructured":"Elsheikh A, Alhasso D, Rama P (2008) Biomechanical properties of human and porcine corneas. Exp Eye Res 86(5):783\u2013790","journal-title":"Exp Eye Res"},{"key":"3598_CR44","unstructured":"Palko JR, Liu J. Definitions and concepts. In Roberts CJ, Liu J (Ed). Corneal biomechanics: from theory to practice. 2016"},{"issue":"6","key":"3598_CR45","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1016\/j.jcrs.2014.04.019","volume":"40","author":"CJ Roberts","year":"2014","unstructured":"Roberts CJ (2014) Concepts and misconceptions in corneal biomechanics. J Cataract Refract Surg 40(6):862\u2013869","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"3598_CR46","first-page":"1330","volume":"11","author":"R Salouti","year":"2018","unstructured":"Salouti R, Alishiri AA, Gharebaghi R, Naderi M, Jadidi K, Shojaei-Baghini A, Talebnejad M, Nasiri Z, Hosseini S, Heidary F (2018) Comparison among Ocular Response Analyzer, Corvis ST and Goldmann Applanation Tonometry in healthy children. Int J Ophthalmol 11(8):1330\u20131336","journal-title":"Int J Ophthalmol"},{"issue":"1","key":"3598_CR47","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1167\/iovs.12-10984","volume":"54","author":"J Hong","year":"2013","unstructured":"Hong J, Xu J, Wei A, Deng SX, Cui X, Yu X, Sun X (2013) A new tonometer\u2014the Corvis ST Tonometer: clinical comparison with noncontact and Goldmann Applanation Tonometers. Invest Ophthalmol Vis Sci 54(1):659","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"2","key":"3598_CR48","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1097\/IIO.0b013e31820f1d2d","volume":"51","author":"R Ambr\u00f3sio","year":"2011","unstructured":"Ambr\u00f3sio R, Nogueira LP, Caldas DL et al (2011) Evaluation of corneal shape and biomechanics before LASIK. Int Ophthalmol Clin 51(2):11\u201338","journal-title":"Int Ophthalmol Clin"},{"key":"3598_CR49","doi-asserted-by":"crossref","unstructured":"Ortiz D, Pi\u00f1ero D, ShabayekMH, Arnalich-Montiel F, Ali\u00f3 JL. Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes. J Cataract Refract Surg. 2007;33(8):1371\u20131375","DOI":"10.1016\/j.jcrs.2007.04.021"},{"issue":"6","key":"3598_CR50","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1097\/ICL.0000000000000280","volume":"43","author":"H Hashemi","year":"2017","unstructured":"Hashemi H, Asgari S, Mortazavi M, Ghaffari R (2017) Evaluation of Corneal Biomechanics After Excimer Laser Corneal Refractive Surgery in High Myopic Patients Using Dynamic Scheimpflug Technology. Eye Contact Lens 43(6):371\u2013377","journal-title":"Eye Contact Lens"},{"key":"3598_CR51","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1097\/ICO.0b013e3181967082","volume":"28","author":"K Kamiya","year":"2009","unstructured":"Kamiya K, Shimizu K, Ohmoto F (2009) Comparison of the changes in corneal biomechanical properties after photorefractive keratectomy and laser in- situkeratomileusis. Cornea 28:765\u2013769","journal-title":"Cornea"},{"key":"3598_CR52","doi-asserted-by":"crossref","first-page":"310","DOI":"10.3928\/1081597X-20140422-01","volume":"30","author":"Y Shen","year":"2014","unstructured":"Shen Y, Chen Z, Knorz MC, Li M, Zhao J, Zhou X (2014) Comparison of corneal deformation parameters after SMILE, LASEK, and femtosecond laser assisted LASIK. J Refract Surg 30:310\u2013318","journal-title":"J Refract Surg"},{"key":"3598_CR53","doi-asserted-by":"crossref","first-page":"454","DOI":"10.3928\/1081597X-20130617-03","volume":"29","author":"DZ Reinstein","year":"2013","unstructured":"Reinstein DZ, Archer TJ, Randleman JB (2013) Mathematical model to compare the relative tensile strength of the cornea after PRK, LASIK, and small incision lenticule extraction. J Refract Surg 29:454\u2013460","journal-title":"J Refract Surg"},{"key":"3598_CR54","doi-asserted-by":"crossref","first-page":"1774","DOI":"10.1016\/j.jcrs.2009.05.041","volume":"35","author":"MA Qazi","year":"2009","unstructured":"Qazi MA, Sanderson JP, Mahmoud AM, Yoon EY, Roberts CJ, Pepose JS (2009) Postoperative changes in intraocular pressure and corneal biomechanical metrics; laser in situ keratomileusis versus laser-assisted subepithelial keratectomy. J Cataract Refract Surg 35:1774\u20131788","journal-title":"J Cataract Refract Surg"},{"key":"3598_CR55","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1136\/bjophthalmol-2013-303415","volume":"98","author":"Z Dong","year":"2014","unstructured":"Dong Z, Zhou X, Wu J, Zhang Z, Li T, Zhou Z, Zhang S, Li G (2014) Small incision lenticule extraction (SMILE) and femtosecond laser LASIK: comparison of corneal wound healing and inflammation. Br J Ophthalmol 98:263\u2013269","journal-title":"Br J Ophthalmol"},{"issue":"6","key":"3598_CR56","doi-asserted-by":"publisher","first-page":"945","DOI":"10.1016\/s0161-6420(97)30202-4","volume":"104","author":"PG Mardelli","year":"1997","unstructured":"Mardelli PG, Piebenga LW, Whitacre MM, Siegmund KD (1997) The effect of excimer laser photorefractive keratectomy on intraocular pressure measurements using the Goldmann applanation tonometer. Ophthalmology 104(6):945\u2013948. https:\/\/doi.org\/10.1016\/s0161-6420(97)30202-4","journal-title":"Ophthalmology"},{"issue":"3","key":"3598_CR57","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1046\/j.1475-1313.2001.00581.x","volume":"21","author":"R Mont\u00e9s-Mic\u00f3","year":"2001","unstructured":"Mont\u00e9s-Mic\u00f3 R, Charman WN (2001) Intraocular pressure after excimer laser myopic refractive surgery. Ophthalmic Physiol Opt 21(3):228\u2013235","journal-title":"Ophthalmic Physiol Opt"},{"key":"3598_CR58","doi-asserted-by":"crossref","first-page":"673","DOI":"10.3928\/1081-597X-19960901-04","volume":"12","author":"S Patel","year":"1996","unstructured":"Patel S, Aslanides IM (1996) Main causes of reduced intraocular pressure after excimer laser photorefractive keratectomy. J Refract Surg 12:673\u2013674","journal-title":"J Refract Surg"},{"key":"3598_CR59","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1016\/j.ophtha.2004.12.033","volume":"112","author":"DH Chang","year":"2005","unstructured":"Chang DH, Stulting RD (2005) Change in intraocular pressure measurementscafter LASIK: the effect of the refractive correctioncand the lamellar flap. Ophthalmology 112:1009\u20131016","journal-title":"Ophthalmology"},{"key":"3598_CR60","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1097\/IJG.0b013e3181639ae2","volume":"17","author":"J Sanchez-Naves","year":"2008","unstructured":"Sanchez-Naves J, Furfaro L, Piro O, Balle S (2008) Impact and permanence of LASIK-induced structural changes in the cornea on pneumotonometric measurements: contributions of flap cutting and stromal ablation. J Glaucoma 17:611\u2013618","journal-title":"J Glaucoma"},{"key":"3598_CR61","doi-asserted-by":"crossref","first-page":"1623","DOI":"10.2147\/OPTH.S362344","volume":"16","author":"RET Ang","year":"2022","unstructured":"Ang RET, Bargas NVR, Martinez GHA, Sosuan GMN, Nabor-Umali MI (2022) Comparison of Three Tonometers in Measuring Intraocular Pressure in Eyes That Underwent Myopic Laser in situ Keratomileusis and Photorefractive Keratectomy. Clin Ophthalmol 16:1623\u20131637","journal-title":"Clin Ophthalmol"},{"issue":"1","key":"3598_CR62","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1186\/s12886-019-1288-6","volume":"20","author":"H Zhang","year":"2020","unstructured":"Zhang H, Sun Z, Li L, Sun R, Zhang H (2020) Comparison of intraocular pressure measured by ocular response analyzer and Goldmann applanation tonometer after corneal refractive surgery: a systematic review and meta-analysis. BMC Ophthalmol 20(1):23","journal-title":"BMC Ophthalmol"},{"issue":"1","key":"3598_CR63","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1186\/s12886-016-0381-3","volume":"16","author":"Y Shen","year":"2016","unstructured":"Shen Y, Su X, Liu X et al (2016) Changes in intraocular pressure values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology tonometer (CST) in the early phase after small incision lenticule extraction (SMILE). BMC Ophthalmol 16(1):205","journal-title":"BMC Ophthalmol"},{"issue":"7","key":"3598_CR64","doi-asserted-by":"crossref","first-page":"967","DOI":"10.1097\/j.jcrs.0000000000000204","volume":"46","author":"S Chen","year":"2020","unstructured":"Chen S, Lopes BT, Huang W et al (2020) Effectiveness of four tonometers in measuring intraocular pressure following femtosecond laser- assisted LASIK, SMILE and transepithelial PRK. J Cataract Refract Surg 46(7):967\u2013974","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"3598_CR65","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/j.clae.2014.05.001","volume":"37","author":"Z Hassan","year":"2014","unstructured":"Hassan Z, Modis L Jr, Szalai E, Berta A, Nemeth G (2014) Examination of ocular biomechanics with a new scheimpflug technology after corneal refractive surgery. Cont Lens Anterior Eye 37(5):337\u2013341","journal-title":"Cont Lens Anterior Eye"},{"issue":"2","key":"3598_CR66","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1016\/j.clae.2015.10.001","volume":"39","author":"M Lanza","year":"2016","unstructured":"Lanza M, Iaccarino S, Mele L et al (2016) Intraocular pressure evaluation in healthy eyes and diseased ones using contact and non contact devices. Cont Lens Anterior Eye 39(2):154\u2013159","journal-title":"Cont Lens Anterior Eye"},{"key":"3598_CR67","doi-asserted-by":"crossref","unstructured":"Lanza, Michele MD, PhD; Sbordone, Sandro MD; Tortori, Antonia MD; Gironi Carnevale, Ugo A. PhD; Melillo, Paolo PhD; Simonelli, Francesca MD. Evaluating Intraocular Pressure After Myopic Photorefractive Keratectomy: A Comparison of Different Tonometers. Journal of Glaucoma 31(6):p 406\u2013412, June 2022","DOI":"10.1097\/IJG.0000000000002023"},{"issue":"5","key":"3598_CR68","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1016\/j.jcrs.2018.01.023","volume":"44","author":"KJ Chen","year":"2018","unstructured":"Chen KJ, Joda A, Vinciguerra R et al (2018) Clinical evaluation of a new correction algorithm for dynamic scheimpflug analyzer tonometry before and after laser in situ keratomileusis and small-incision lenticule extraction. J Cataract Refract Surg 44(5):581\u2013588","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"3598_CR69","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1007\/s10792-012-9701-7","volume":"33","author":"S Hamed-Azzam","year":"2013","unstructured":"Hamed-Azzam S, Briscoe D, Tomkins O, Shehedeh-Mashor R, Garzozi H (2013) Evaluation of intraocular pressure according to corneal thickness before and after excimer laser corneal ablation for myopia. Int Ophthalmol 33(4):349\u2013354","journal-title":"Int Ophthalmol"}],"container-title":["International Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-025-03598-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10792-025-03598-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-025-03598-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,19]],"date-time":"2025-12-19T18:03:42Z","timestamp":1766167422000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10792-025-03598-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,6]]},"references-count":69,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["3598"],"URL":"https:\/\/doi.org\/10.1007\/s10792-025-03598-z","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-3881547\/v1","asserted-by":"object"}]},"ISSN":["1573-2630"],"issn-type":[{"value":"1573-2630","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,6]]},"assertion":[{"value":"20 January 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 June 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The study was conducted according to the tenets of the Declaration of Helsinki and the Ethics Committee of the Hospital involved.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent for the treatment protocol and the data collection was obtained from all the patients.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed Consent"}},{"value":"All authors have signed a consent form for the publication of the article.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to Publish"}}],"article-number":"232"}}