{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T07:22:44Z","timestamp":1784618564084,"version":"3.55.0"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,4]],"date-time":"2025-07-04T00:00:00Z","timestamp":1751587200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,7,4]],"date-time":"2025-07-04T00:00:00Z","timestamp":1751587200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["82171037"],"award-info":[{"award-number":["82171037"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int Ophthalmol"],"DOI":"10.1007\/s10792-025-03645-9","type":"journal-article","created":{"date-parts":[[2025,7,4]],"date-time":"2025-07-04T08:26:50Z","timestamp":1751617610000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["The accuracy of VRF intraocular lens power calculation formula in cataract patients after radial keratotomy"],"prefix":"10.1007","volume":"45","author":[{"given":"Zhao-Xing","family":"Guo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peng","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhi-Yong","family":"Tian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiu-Hua","family":"Wan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meng","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,7,4]]},"reference":[{"issue":"1","key":"3645_CR1","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/j.ophtha.2021.07.031","volume":"129","author":"Y Yang","year":"2022","unstructured":"Yang Y, Chen W, Xu A, Zhao L, Ding X, Li J, Zhu Y, Chen C, Long E, Liu Z et al (2022) Spatial technology assessment of green space exposure and myopia. Ophthalmology 129(1):113\u2013117","journal-title":"Ophthalmology"},{"issue":"2","key":"3645_CR2","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1038\/s41433-020-1096-5","volume":"35","author":"M Ang","year":"2021","unstructured":"Ang M, Gatinel D, Reinstein DZ, Mertens E, Ali\u00f3 Del Barrio JL, Ali\u00f3 JL (2021) Refractive surgery beyond 2020. Eye (Lond) 35(2):362\u2013382","journal-title":"Eye (Lond)"},{"issue":"2","key":"3645_CR3","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1097\/00004397-198802820-00004","volume":"28","author":"SL Forstot","year":"1988","unstructured":"Forstot SL (1988) Radial keratotomy. Int Ophthalmol Clin 28(2):116\u2013125","journal-title":"Int Ophthalmol Clin"},{"key":"3645_CR4","doi-asserted-by":"publisher","first-page":"2591","DOI":"10.2147\/OPTH.S227629","volume":"13","author":"JA Hovanesian","year":"2019","unstructured":"Hovanesian JA, Lane SS, Allen QB, Jones M (2019) Patient-reported outcomes\/satisfaction and spectacle independence with blended or bilateral multifocal intraocular lenses in cataract surgery. Clin Ophthalmol 13:2591\u20132598","journal-title":"Clin Ophthalmol"},{"issue":"22","key":"3645_CR5","doi-asserted-by":"publisher","first-page":"1553","DOI":"10.21037\/atm-20-2290","volume":"8","author":"G Savini","year":"2020","unstructured":"Savini G, Taroni L, Hoffer KJ (2020) Recent developments in intraocular lens power calculation methods-update 2020. Ann Transl Med 8(22):1553","journal-title":"Ann Transl Med"},{"key":"3645_CR6","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.ajo.2017.10.020","volume":"185","author":"OV Voytsekhivskyy","year":"2018","unstructured":"Voytsekhivskyy OV (2018) Development and clinical accuracy of a new intraocular lens power formula (VRF) compared to other formulas. Am J Ophthalmol 185:56\u201367","journal-title":"Am J Ophthalmol"},{"issue":"1","key":"3645_CR7","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1186\/s40001-023-00998-8","volume":"28","author":"M Li","year":"2023","unstructured":"Li M, Wang JD, Zhang JS, Mao YY, Cao K, Wan XH (2023) Comparison of the accuracy of three intraocular lens power calculation formulas in cataract patients with prior radial keratotomy. Eur J Med Res 28(1):20","journal-title":"Eur J Med Res"},{"issue":"3","key":"3645_CR8","doi-asserted-by":"publisher","first-page":"300060519895679","DOI":"10.1177\/0300060519895679","volume":"48","author":"JD Wang","year":"2020","unstructured":"Wang JD, Liu X, Zhang JS, Xiong Y, Li J, Li XX, Zhao J, You QS, Huang Y, Espina M et al (2020) Effects and risks of transparent corneal incision phacoemulsification for cataract after radial keratotomy. J Int Med Res 48(3):300060519895679","journal-title":"J Int Med Res"},{"issue":"12","key":"3645_CR9","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0165474","volume":"11","author":"JS Zhang","year":"2016","unstructured":"Zhang JS, Liu X, Wang JD, Xiong Y, Li J, Li XX, Zhao J, You QS, Huang Y, Tsai F et al (2016) Outcomes of phacoemulsification using different size of clear corneal incision in eyes with previous radial keratotomy. PLoS ONE 11(12):e0165474","journal-title":"PLoS ONE"},{"issue":"7","key":"3645_CR10","doi-asserted-by":"publisher","first-page":"466","DOI":"10.3928\/1081597X-20200514-02","volume":"36","author":"H Cheng","year":"2020","unstructured":"Cheng H, Kane JX, Liu L, Li J, Cheng B, Wu M (2020) Refractive predictability using the IOLMaster 700 and artificial intelligence-based IOL power formulas compared to standard formulas. J Refract Surg 36(7):466\u2013472","journal-title":"J Refract Surg"},{"key":"3645_CR11","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/j.ajo.2023.09.023","volume":"262","author":"G Debellemani\u00e8re","year":"2024","unstructured":"Debellemani\u00e8re G, Mechleb N, Bernier T, Ancel JM, Gauvin M, Wallerstein A, Saad A, Gatinel D (2024) The development of a thick-lens post-myopic laser vision correction intraocular lens calculation formula. Am J Ophthalmol 262:40\u201347","journal-title":"Am J Ophthalmol"},{"issue":"12","key":"3645_CR12","doi-asserted-by":"publisher","first-page":"2443","DOI":"10.1016\/j.ophtha.2015.08.037","volume":"122","author":"L Wang","year":"2015","unstructured":"Wang L, Tang M, Huang D, Weikert MP, Koch DD (2015) Comparison of newer intraocular lens power calculation methods for eyes after corneal refractive surgery. Ophthalmology 122(12):2443\u20132449","journal-title":"Ophthalmology"},{"issue":"8","key":"3645_CR13","doi-asserted-by":"publisher","first-page":"999","DOI":"10.1016\/j.jcrs.2017.08.003","volume":"43","author":"L Wang","year":"2017","unstructured":"Wang L, Koch DD, Hill W, Abulafia A (2017) Pursuing perfection in intraocular lens calculations: III. Criteria for analyzing outcomes. J Cataract Refract Surg 43(8):999\u20131002","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"3645_CR14","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1016\/j.ajo.2015.05.029","volume":"160","author":"KJ Hoffer","year":"2015","unstructured":"Hoffer KJ, Aramberri J, Haigis W, Olsen T, Savini G, Shammas HJ, Bentow S (2015) Protocols for studies of intraocular lens formula accuracy. Am J Ophthalmol 160(3):403-405.e401","journal-title":"Am J Ophthalmol"},{"issue":"9","key":"3645_CR15","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1167\/iovs.15-18948","volume":"57","author":"JX Ma","year":"2016","unstructured":"Ma JX, Tang M, Wang L, Weikert MP, Huang D, Koch DD (2016) Comparison of newer IOL power calculation methods for eyes with previous radial keratotomy. Investig Ophthalmol Vis Sci 57(9):162\u2013168","journal-title":"Investig Ophthalmol Vis Sci"},{"issue":"10","key":"3645_CR16","doi-asserted-by":"publisher","first-page":"1416","DOI":"10.1016\/j.jcrs.2019.05.020","volume":"45","author":"L Wang","year":"2019","unstructured":"Wang L, Spektor T, de Souza RG, Koch DD (2019) Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery. J Cataract Refract Surg 45(10):1416\u20131421","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"3645_CR17","doi-asserted-by":"publisher","first-page":"656","DOI":"10.3928\/1081597X-20190913-01","volume":"35","author":"SX Curado","year":"2019","unstructured":"Curado SX, Hida WT, Cortez Vilar CM, Ordones VL, Pereira Chaves MA, Tzelikis PF (2019) Intraoperative aberrometry versus preoperative biometry for IOL power selection after radial keratotomy: a prospective study. J Refract Surg 35(10):656\u2013662","journal-title":"J Refract Surg"},{"issue":"6","key":"3645_CR18","doi-asserted-by":"publisher","first-page":"e844","DOI":"10.1111\/aos.14688","volume":"99","author":"VJ Dawson","year":"2021","unstructured":"Dawson VJ, Patnaik JL, Ifantides C, Miller DC, Lynch AM, Christopher KL (2021) Comparison of refractive prediction for intraoperative aberrometry and Barrett True K no history formula in cataract surgery patients with prior radial keratotomy. Acta Ophthalmol 99(6):e844\u2013e851","journal-title":"Acta Ophthalmol"},{"issue":"1","key":"3645_CR19","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1136\/bjophthalmol-2020-317681","volume":"106","author":"P Patel","year":"2022","unstructured":"Patel P, Ashena Z, Vasavada V, Vasavada SA, Vasavada V, Sudhalkar A, Nanavaty MA (2022) Comparison of intraocular lens calculation methods after myopic laser-assisted in situ keratomileusis and radial keratotomy without prior refractive data. Br J Ophthalmol 106(1):47\u201353","journal-title":"Br J Ophthalmol"},{"issue":"1","key":"3645_CR20","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/j.ophtha.2019.08.019","volume":"127","author":"AMJ Turnbull","year":"2020","unstructured":"Turnbull AMJ, Crawford GJ, Barrett GD (2020) Methods for intraocular lens power calculation in cataract surgery after radial keratotomy. Ophthalmology 127(1):45\u201351","journal-title":"Ophthalmology"},{"issue":"9","key":"3645_CR21","doi-asserted-by":"publisher","first-page":"1804","DOI":"10.1038\/s41433-021-01716-6","volume":"36","author":"C Soare","year":"2022","unstructured":"Soare C, Patel DS, Ionides A (2022) Cataract surgery outcomes in eyes with previous radial keratotomy. Eye (Lond) 36(9):1804\u20131809","journal-title":"Eye (Lond)"},{"key":"3645_CR22","doi-asserted-by":"publisher","first-page":"2589","DOI":"10.2147\/OPTH.S417336","volume":"17","author":"HA Helaly","year":"2023","unstructured":"Helaly HA, Elhady AM, Elnaggar OR (2023) Accuracy of traditional and modern formulas for intraocular lens power calculation after radial keratotomy using standard keratometry. Clin Ophthalmol 17:2589\u20132597","journal-title":"Clin Ophthalmol"},{"issue":"9","key":"3645_CR23","doi-asserted-by":"publisher","first-page":"3224","DOI":"10.4103\/IJO.IJO_3417_22","volume":"71","author":"N Shetty","year":"2023","unstructured":"Shetty N, Sathe P, Aishwarya, Francis M, Shetty R (2023) Comparison of intraocular lens power prediction accuracy of formulas in American Society of Cataract and Refractive Surgery post-refractive surgery calculator in eyes with prior radial keratotomy. Indian J Ophthalmol 71(9):3224\u20133228","journal-title":"Indian J Ophthalmol"},{"issue":"6","key":"3645_CR24","doi-asserted-by":"publisher","first-page":"1703","DOI":"10.1007\/s40123-024-00946-7","volume":"13","author":"M Moshirfar","year":"2024","unstructured":"Moshirfar M, Sperry RA, Altaf AW, Stoakes IM, Hoopes PC (2024) Predictability of existing IOL formulas after cataract surgery in patients with a previous history of radial keratotomy: a retrospective cohort study and literature review. Ophthalmol Ther 13(6):1703\u20131722","journal-title":"Ophthalmol Ther"},{"issue":"2","key":"3645_CR25","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1097\/ICO.0000000000003301","volume":"43","author":"S Ferrara","year":"2024","unstructured":"Ferrara S, Crincoli E, Savastano A, Savastano MC, Catania F, Rizzo S (2024) Refractive outcomes with new generation formulas for intraocular lens power calculation in radial keratotomy patients. Cornea 43(2):178\u2013183","journal-title":"Cornea"},{"issue":"15","key":"3645_CR26","doi-asserted-by":"publisher","first-page":"2947","DOI":"10.1038\/s41433-024-03195-x","volume":"38","author":"OV Voytsekhivskyy","year":"2024","unstructured":"Voytsekhivskyy OV (2024) The VRF-L and VRF-GL IOL power calculation methods after radial keratotomy. Eye (Lond) 38(15):2947\u20132954","journal-title":"Eye (Lond)"},{"issue":"1","key":"3645_CR27","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1186\/s40001-023-00998-8","volume":"28","author":"M Li","year":"2023","unstructured":"Li M, Wang JD, Zhang JS, Mao YY, Cao K, Wan XH (2023) Comparison of the accuracy of three intraocular lens power calculation formulas in cataract patients with prior radial keratotomy. Eur J Med Res 28(1):20","journal-title":"Eur J Med Res"},{"issue":"4","key":"3645_CR28","doi-asserted-by":"publisher","first-page":"275","DOI":"10.3928\/1081597X-20120221-03","volume":"28","author":"M Camellin","year":"2012","unstructured":"Camellin M, Savini G, Hoffer KJ, Carbonelli M, Barboni P (2012) Scheimpflug camera measurement of anterior and posterior corneal curvature in eyes with previous radial keratotomy. J Refract Surg 28(4):275\u2013279","journal-title":"J Refract Surg"},{"issue":"11","key":"3645_CR29","doi-asserted-by":"publisher","first-page":"e121","DOI":"10.1016\/j.ophtha.2020.06.054","volume":"128","author":"L Wang","year":"2021","unstructured":"Wang L, Koch DD (2021) Intraocular lens power calculations in eyes with previous corneal refractive surgery: review and expert opinion. Ophthalmology 128(11):e121\u2013e131","journal-title":"Ophthalmology"},{"issue":"1","key":"3645_CR30","doi-asserted-by":"publisher","first-page":"160","DOI":"10.3928\/1081-597X-19960101-27","volume":"12","author":"S Chavez","year":"1996","unstructured":"Chavez S, Celikkol L, Feldman ST (1996) Hyperopic shift and myopic regression in a patient 7 years after bilateral refractive keratotomy. J Refract Surg 12(1):160\u2013162","journal-title":"J Refract Surg"},{"key":"3645_CR31","volume":"2015","author":"P Chhadva","year":"2015","unstructured":"Chhadva P, Cabot F, Galor A, Yoo SH (2015) Long-term outcomes of radial keratotomy, laser in situ keratomileusis, and astigmatic keratotomy performed consecutively over a period of 21 years. Case Rep Ophthalmol Med 2015:592495","journal-title":"Case Rep Ophthalmol Med"},{"issue":"2","key":"3645_CR32","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1016\/S0161-6420(96)30711-2","volume":"103","author":"PJ McDonnell","year":"1996","unstructured":"McDonnell PJ, Nizam A, Lynn MJ, Waring GO 3rd (1996) Morning-to-evening change in refraction, corneal curvature, and visual acuity 11 years after radial keratotomy in the prospective evaluation of radial keratotomy study The PERK study group. Ophthalmology 103(2):233\u2013239","journal-title":"Ophthalmology"},{"key":"3645_CR33","doi-asserted-by":"publisher","first-page":"4395","DOI":"10.2147\/OPTH.S290125","volume":"14","author":"D Hip\u00f3lito-Fernandes","year":"2020","unstructured":"Hip\u00f3lito-Fernandes D, Elisa Lu\u00eds M, Gil P, Maduro V, Feij\u00e3o J, Yeo TK, Voytsekhivskyy O, Alves N (2020) VRF-G, a New Intraocular Lens Power Calculation Formula: A 13-Formulas Comparison Study. Clin Ophthalmol 14:4395\u20134402","journal-title":"Clin Ophthalmol"},{"issue":"10","key":"3645_CR34","doi-asserted-by":"publisher","first-page":"656","DOI":"10.3928\/1081597X-20190913-01","volume":"35","author":"SX Curado","year":"2019","unstructured":"Curado SX, Hida WT, Vilar CMC, Ordones VL, Chaves MAP, Tzelikis PF (2019) Intraoperative aberrometry versus preoperative biometry for IOL power selection after radial keratotomy: a prospective study. J Refract Surg 35(10):656\u2013661","journal-title":"J Refract Surg"}],"container-title":["International Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-025-03645-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10792-025-03645-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10792-025-03645-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,19]],"date-time":"2025-12-19T18:03:51Z","timestamp":1766167431000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10792-025-03645-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,4]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["3645"],"URL":"https:\/\/doi.org\/10.1007\/s10792-025-03645-9","relation":{},"ISSN":["1573-2630"],"issn-type":[{"value":"1573-2630","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,4]]},"assertion":[{"value":"14 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 June 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interest"}},{"value":"This study performed in line with the principles of Declaration of Helsinki. Approval was granted by the Ethics Committee of Beijing Tongren Hospital. Informed consent was obtained from all individual participants included in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}],"article-number":"278"}}