{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,9]],"date-time":"2026-03-09T00:50:34Z","timestamp":1773017434376,"version":"3.50.1"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2014,9,17]],"date-time":"2014-09-17T00:00:00Z","timestamp":1410912000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"published-print":{"date-parts":[[2014,11]]},"DOI":"10.1007\/s10840-014-9942-7","type":"journal-article","created":{"date-parts":[[2014,9,16]],"date-time":"2014-09-16T04:05:55Z","timestamp":1410840355000},"page":"177-186","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":45,"title":["Acute procedural and cryoballoon characteristics from cryoablation of atrial fibrillation using the first- and second-generation cryoballoon: a retrospective comparative study with follow-up outcomes"],"prefix":"10.1007","volume":"41","author":[{"given":"Arash","family":"Aryana","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shemsa","family":"Morkoch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sean","family":"Bailey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hae W.","family":"Lim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rahmani","family":"Sara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andr\u00e9","family":"d\u2019Avila","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P. Gearoid","family":"O\u2019Neill","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2014,9,17]]},"reference":[{"issue":"16","key":"9942_CR1","doi-asserted-by":"crossref","first-page":"1713","DOI":"10.1016\/j.jacc.2012.11.064","volume":"61","author":"DL Packer","year":"2013","unstructured":"Packer, D. L., Kowal, R. C., Wheelan, K. R., Cryoablation Investigators, S. T. O. P. A. F., et al. (2013). Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front (STOP AF) pivotal trial. Journal of the American College of Cardiology, 61(16), 1713\u20131723.","journal-title":"Journal of the American College of Cardiology"},{"issue":"2","key":"9942_CR2","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1093\/europace\/eur299","volume":"14","author":"M Namdar","year":"2012","unstructured":"Namdar, M., Chierchia, G. B., Westra, S., et al. (2012). Isolating the pulmonary veins as first-line therapy in patients with lone paroxysmal atrial fibrillation using the Cryoballoon. Europace, 14(2), 197\u2013203.","journal-title":"Europace"},{"issue":"11","key":"9942_CR3","doi-asserted-by":"crossref","first-page":"1271","DOI":"10.1093\/europace\/eun218","volume":"10","author":"Y Belle Van","year":"2008","unstructured":"Van Belle, Y., Janse, P., Theuns, D., Szili-Torok, T., & Jordaens, L. (2008). One year follow-up after cryoballoon isolation of the pulmonary veins in patients with paroxysmal atrial fibrillation. Europace, 10(11), 1271\u20131276.","journal-title":"Europace"},{"issue":"6","key":"9942_CR4","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1016\/j.hrthm.2008.02.014","volume":"5","author":"G Klein","year":"2008","unstructured":"Klein, G., Oswald, H., Gardiwal, A., et al. (2008). Efficacy of pulmonary vein isolation by cryoballoon ablation in patients with paroxysmal atrial fibrillation. Heart Rhythm, 5(6), 802\u2013806.","journal-title":"Heart Rhythm"},{"issue":"4","key":"9942_CR5","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1016\/j.jacc.2008.04.021","volume":"52","author":"T Neumann","year":"2008","unstructured":"Neumann, T., Vogt, J., Schumacher, B., et al. (2008). Circumferential pulmonary vein isolation with the cryoballoon technique: results from a prospective 3-center study. Journal of the American College of Cardiology, 52(4), 273\u2013278.","journal-title":"Journal of the American College of Cardiology"},{"issue":"2","key":"9942_CR6","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1016\/j.hrthm.2009.10.038","volume":"7","author":"A F\u00fcrnkranz","year":"2010","unstructured":"F\u00fcrnkranz, A., Chun, K. R., Nuyens, D., et al. (2010). Characterization of conduction recovery after pulmonary vein isolation using the \u201csingle big cryoballoon\u201d technique. Heart Rhythm, 7(2), 184\u2013190.","journal-title":"Heart Rhythm"},{"issue":"5","key":"9942_CR7","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1111\/jce.12082","volume":"24","author":"A F\u00fcrnkranz","year":"2013","unstructured":"F\u00fcrnkranz, A., Bordignon, S., Schmidt, B., et al. (2013). Improved procedural efficacy of pulmonary vein isolation using the novel second-generation cryoballoon. Journal of Cardiovascular Electrophysiology, 24(5), 492\u2013497.","journal-title":"Journal of Cardiovascular Electrophysiology"},{"issue":"9","key":"9942_CR8","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1016\/j.hrthm.2013.07.005","volume":"10","author":"R Casado-Arroyo","year":"2013","unstructured":"Casado-Arroyo, R., Chierchia, G. B., Conte, G., et al. (2013). Phrenic nerve paralysis during cryoballoon ablation for atrial fibrillation: a comparison between the first- and second-generation balloon. Heart Rhythm, 10(9), 1318\u20131324.","journal-title":"Heart Rhythm"},{"issue":"6","key":"9942_CR9","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1016\/j.hrthm.2013.02.021","volume":"10","author":"A F\u00fcrnkranz","year":"2013","unstructured":"F\u00fcrnkranz, A., Bordignon, S., Schmidt, B., et al. (2013). Luminal esophageal temperature predicts esophageal lesions after second-generation cryoballoon pulmonary vein isolation. Heart Rhythm, 10(6), 789\u2013793.","journal-title":"Heart Rhythm"},{"issue":"4","key":"9942_CR10","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1161\/CIRCEP.113.000228","volume":"6","author":"A Metzner","year":"2013","unstructured":"Metzner, A., Burchard, A., Wohlmuth, P., et al. (2013). Increased incidence of esophageal thermal lesions using the second-generation 28\u00a0mm cryoballoon. Circulation. Arrhythmia and Electrophysiology, 6(4), 769\u2013775.","journal-title":"Circulation. Arrhythmia and Electrophysiology"},{"key":"9942_CR11","doi-asserted-by":"crossref","unstructured":"Lim, H. W., Cogert, G. A., Cameron, C. S., Cheng, V. Y., Sandler, D. A. (2014). Atrioesophageal fistula during cryoballoon ablation for atrial fibrillation. Journal of Cardiovascular Electrophysiology, 25(2), 208\u2013213.","DOI":"10.1111\/jce.12313"},{"issue":"6","key":"9942_CR12","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1111\/jce.12114","volume":"24","author":"JG Andrade","year":"2013","unstructured":"Andrade, J. G., Dubuc, M., Guerra, P. G., et al. (2013). Pulmonary vein isolation using a second-generation cryoballoon catheter: a randomized comparison of ablation duration and method of deflation. Journal of Cardiovascular Electrophysiology, 24(6), 692\u2013698.","journal-title":"Journal of Cardiovascular Electrophysiology"},{"issue":"2","key":"9942_CR13","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1007\/s10840-013-9855-x","volume":"39","author":"GB Chierchia","year":"2014","unstructured":"Chierchia, G. B., Di Giovanni, G., Sieira-Moret, J., et al. (2014). Initial experience of three-minute freeze cycles using the second-generation cryoballoon ablation: acute and short-term procedural outcomes. Journal of Interventional Cardiac Electrophysiology, 39(2), 145\u2013151.","journal-title":"Journal of Interventional Cardiac Electrophysiology"},{"key":"9942_CR14","doi-asserted-by":"crossref","unstructured":"F\u00fcrnkranz, A., Bordignon, S., Dugo, D., et al. (2014). Improved one-year clinical success rate of pulmonary vein isolation with the second-generation cryoballoon in patients with paroxysmal atrial fibrillation. Journal of Cardiovascular Electrophysiology, 25(8), 840\u2013844.","DOI":"10.1111\/jce.12417"},{"key":"9942_CR15","doi-asserted-by":"crossref","unstructured":"Giovanni, G. D., Wauters, K., Chierchia, G. B., et al. (2014). One-year follow-up after single procedure cryoballoon ablation: a comparison between the first and second generation balloon. Journal of Cardiovascular Electrophysiology, 25(8), 834-839.","DOI":"10.1111\/jce.12409"},{"issue":"7","key":"9942_CR16","doi-asserted-by":"crossref","first-page":"1074","DOI":"10.1016\/j.hrthm.2013.02.026","volume":"10","author":"JS Chinitz","year":"2013","unstructured":"Chinitz, J. S., Kulina, R. A., Gangireddy, S. R., et al. (2013). Objective quality assessment of atrial fibrillation ablation: a novel scoring system. Heart Rhythm, 10(7), 1074\u20131079.","journal-title":"Heart Rhythm"},{"issue":"6","key":"9942_CR17","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1093\/eurheartj\/ehn570","volume":"30","author":"KR Chun","year":"2009","unstructured":"Chun, K. R., Schmidt, B., Metzner, A., et al. (2009). The \u2018single big cryoballoon\u2019 technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study. European Heart Journal, 30(6), 699\u2013709.","journal-title":"European Heart Journal"},{"key":"9942_CR18","doi-asserted-by":"crossref","unstructured":"Ciconte, G., Chierchia, G. B., de Asmundis, C., et al. (2014). Spontaneous and adenosine-induced pulmonary vein reconnection after cryoballoon ablation with the second generation device. Journal of Cardiovascular Electrophysiology, 25(8), 848\u2013851.","DOI":"10.1111\/jce.12421"},{"issue":"1","key":"9942_CR19","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s10840-014-9883-1","volume":"40","author":"S Knecht","year":"2014","unstructured":"Knecht, S., K\u00fchne, M., Osswald, S., Sticherling, C., et al. (2014). Quantitative assessment of a second-generation cryoballoon ablation catheter with new cooling technology\u2014a perspective on potential implications on outcome. Journal of Cardiovascular Electrophysiology, 40(1), 17\u201321.","journal-title":"Journal of Cardiovascular Electrophysiology"},{"issue":"2","key":"9942_CR20","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1161\/CIRCEP.114.001473","volume":"7","author":"A Metzner","year":"2014","unstructured":"Metzner, A., Reissmann, B., Rausch, P., et al. (2014). One-year clinical outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon. Circulation. Arrhythmia and Electrophysiology, 7(2), 288\u2013292.","journal-title":"Circulation. Arrhythmia and Electrophysiology"},{"issue":"5","key":"9942_CR21","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1093\/europace\/eut417","volume":"16","author":"GB Chierchia","year":"2014","unstructured":"Chierchia, G. B., Di Giovanni, G., Ciconte, G., et al. (2014). Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up. Europace, 16(5), 639\u2013644.","journal-title":"Europace"},{"issue":"7","key":"9942_CR22","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1093\/europace\/eut400","volume":"16","author":"S Bordignon","year":"2014","unstructured":"Bordignon, S., F\u00fcrnkranz, A., Dugo, D., et al. (2014). Improved lesion formation using the novel 28\u00a0mm cryoballoon in atrial fibrillation ablation: analysis of biomarker release. Europace, 16(7), 987\u2013993.","journal-title":"Europace"},{"issue":"5","key":"9942_CR23","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1111\/jce.12358","volume":"25","author":"A Metzner","year":"2014","unstructured":"Metzner, A., Rausch, P., Lemes, C., et al. (2014). The incidence of phrenic nerve injury during pulmonary vein isolation using the second-generation 28\u00a0mm cryoballoon. Journal of Cardiovascular Electrophysiology, 25(5), 466\u2013470.","journal-title":"Journal of Cardiovascular Electrophysiology"},{"issue":"3","key":"9942_CR24","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1006\/cryo.1998.2115","volume":"37","author":"AA Gage","year":"1998","unstructured":"Gage, A. A., & Baust, J. (1998). Mechanisms of tissue injury in cryosurgery. Cryobiology, 37(3), 171\u2013186.","journal-title":"Cryobiology"},{"issue":"9","key":"9942_CR25","doi-asserted-by":"crossref","first-page":"1311","DOI":"10.1016\/j.hrthm.2013.06.014","volume":"10","author":"J Ghosh","year":"2013","unstructured":"Ghosh, J., Martin, A., Keech, A. C., et al. (2013). Balloon warming time is the strongest predictor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillation. Heart Rhythm, 10(9), 1311\u20131317.","journal-title":"Heart Rhythm"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-014-9942-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10840-014-9942-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-014-9942-7","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,30]],"date-time":"2019-05-30T22:04:11Z","timestamp":1559253851000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10840-014-9942-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,9,17]]},"references-count":25,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2014,11]]}},"alternative-id":["9942"],"URL":"https:\/\/doi.org\/10.1007\/s10840-014-9942-7","relation":{},"ISSN":["1383-875X","1572-8595"],"issn-type":[{"value":"1383-875X","type":"print"},{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,9,17]]}}}