{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T14:22:18Z","timestamp":1780323738879,"version":"3.54.1"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2015,4,30]],"date-time":"2015-04-30T00:00:00Z","timestamp":1430352000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"published-print":{"date-parts":[[2015,9]]},"DOI":"10.1007\/s10840-015-0002-8","type":"journal-article","created":{"date-parts":[[2015,4,29]],"date-time":"2015-04-29T06:20:54Z","timestamp":1430288454000},"page":"297-306","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":38,"title":["Contact force and impedance decrease during ablation depends on catheter location and orientation: insights from pulmonary vein isolation using a contact force-sensing catheter"],"prefix":"10.1007","volume":"43","author":[{"given":"Sven","family":"Knecht","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tobias","family":"Reichlin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nikola","family":"Pavlovic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Beat","family":"Schaer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Osswald","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Sticherling","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"K\u00fchne","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2015,4,30]]},"reference":[{"key":"2_CR1","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1016\/S0735-1097(87)80388-1","volume":"9","author":"SK Huang","year":"1987","unstructured":"Huang, S. K., Bharati, S., Graham, A. R., Lev, M., Marcus, F. I., & Odell, R. C. (1987). Closed chest catheter desiccation of the atrioventricular junction using radiofrequency energy\u2014a new method of catheter ablation. Journal of the American College of Cardiology, 9, 349\u2013358.","journal-title":"Journal of the American College of Cardiology"},{"key":"2_CR2","doi-asserted-by":"crossref","first-page":"1160","DOI":"10.1016\/j.ijcard.2012.11.072","volume":"168","author":"S Haldar","year":"2013","unstructured":"Haldar, S., Jarman, J. W. E., Panikker, S., Jones, D. G., Salukhe, T., Gupta, D., et al. (2013). Contact force sensing technology identifies sites of inadequate contact and reduces acute pulmonary vein reconnection: a prospective case control study. International Journal of Cardiology, 168, 1160\u20131166.","journal-title":"International Journal of Cardiology"},{"key":"2_CR3","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1093\/europace\/eut262","volume":"16","author":"G Stabile","year":"2014","unstructured":"Stabile, G., Solimene, F., Cal\u00f2, L., Anselmino, M., Castro, A., Pratola, C., et al. (2014). Catheter-tissue contact force for pulmonary veins isolation: a pilot multicentre study on effect on procedure and fluoroscopy time. Europace, 16, 335\u2013340.","journal-title":"Europace"},{"key":"2_CR4","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.1161\/CIRCEP.113.000749","volume":"6","author":"A Bortone","year":"2013","unstructured":"Bortone, A., Appetiti, A., Bouzeman, A., Maupas, E., Ciobotaru, V., Boulenc, J.-M., et al. (2013). Unipolar signal modification as a guide for lesion creation during radiofrequency application in the left atrium: prospective study in humans in the setting of paroxysmal atrial fibrillation catheter ablation. Circulation. Arrhythmia and Electrophysiology, 6, 1095\u20131102.","journal-title":"Circulation. Arrhythmia and Electrophysiology"},{"key":"2_CR5","doi-asserted-by":"crossref","first-page":"1210","DOI":"10.1111\/jce.12215","volume":"24","author":"A Bortoli De","year":"2013","unstructured":"De Bortoli, A., Sun, L.-Z., Solheim, E., Hoff, P. I., Schuster, P., Ohm, O.-J., et al. (2013). Ablation effect indicated by impedance fall is correlated with contact force level during ablation for atrial fibrillation. Journal of Cardiovascular Electrophysiology, 24, 1210\u20131215.","journal-title":"Journal of Cardiovascular Electrophysiology"},{"key":"2_CR6","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.hrthm.2013.10.048","volume":"11","author":"T Reichlin","year":"2014","unstructured":"Reichlin, T., Knecht, S., Lane, C., K\u00fchne, M., Nof, E., Chopra, N., et al. (2014). Initial impedance decrease as an indicator of good catheter contact: Insights from radiofrequency ablation with force sensing catheters. Heart Rhythm, 11, 194\u2013201.","journal-title":"Heart Rhythm"},{"key":"2_CR7","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1111\/jce.12293","volume":"25","author":"S Kumar","year":"2014","unstructured":"Kumar, S., Chan, M., Lee, J., Wong, M. C. G., Yudi, M., Morton, J. B., et al. (2014). Catheter-tissue contact force determines atrial electrogram characteristics before and lesion efficacy after antral pulmonary vein isolation in humans. Journal of Cardiovascular Electrophysiology, 25, 122\u2013129.","journal-title":"Journal of Cardiovascular Electrophysiology"},{"key":"2_CR8","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1016\/j.hrthm.2013.03.022","volume":"10","author":"S Kumar","year":"2013","unstructured":"Kumar, S., Haqqani, H. M., Chan, M., Lee, J., Yudi, M., Wong, M. C. G., et al. (2013). Predictive value of impedance changes for real-time contact force measurements during catheter ablation of atrial arrhythmias in humans. Heart Rhythm, 10, 962\u2013969.","journal-title":"Heart Rhythm"},{"key":"2_CR9","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1161\/CIRCEP.113.000556","volume":"7","author":"H Makimoto","year":"2014","unstructured":"Makimoto, H., Metzner, A., Lin, T., Rillig, A., Wohlmuth, P., Arya, A., et al. (2014). In vivo contact force analysis and correlation with tissue impedance during left atrial mapping and catheter ablation of atrial fibrillation. Circulation. Arrhythmia and Electrophysiology, 7, 46\u201354.","journal-title":"Circulation. Arrhythmia and Electrophysiology"},{"key":"2_CR10","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1161\/CIRCEP.113.000374","volume":"6","author":"P Neuzil","year":"2013","unstructured":"Neuzil, P., Reddy, V. Y., Kautzner, J., Petru, J., Wichterle, D., Shah, D., et al. (2013). Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study. Circulation. Arrhythmia and Electrophysiology, 6, 327\u2013333.","journal-title":"Circulation. Arrhythmia and Electrophysiology"},{"key":"2_CR11","doi-asserted-by":"crossref","first-page":"1789","DOI":"10.1016\/j.hrthm.2012.07.016","volume":"9","author":"VY Reddy","year":"2012","unstructured":"Reddy, V. Y., Shah, D., Kautzner, J., Schmidt, B., Saoudi, N., Herrera, C., et al. (2012). The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. Heart Rhythm, 9, 1789\u20131795.","journal-title":"Heart Rhythm"},{"key":"2_CR12","doi-asserted-by":"crossref","first-page":"1124","DOI":"10.1161\/CIRCEP.112.972208","volume":"5","author":"S Kumar","year":"2012","unstructured":"Kumar, S., Morton, J. B., Lee, J., Halloran, K., Spence, S. J., Gorelik, A., et al. (2012). Prospective characterization of catheter-tissue contact force at different anatomic sites during antral pulmonary vein isolation. Circulation. Arrhythmia and Electrophysiology, 5, 1124\u20131129.","journal-title":"Circulation. Arrhythmia and Electrophysiology"},{"key":"2_CR13","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1007\/BF02345754","volume":"38","author":"S Tungjitkusolmun","year":"2000","unstructured":"Tungjitkusolmun, S., Woo, E. J., Cao, H., Tsai, J. Z., Vorperian, V. R., & Webster, P. J. G. (2000). Thermal\u2013electrical finite element modelling for radio frequency cardiac ablation: effects of changes in myocardial properties. Medical and Biological Engineering and Computing, 38, 562\u2013568.","journal-title":"Medical and Biological Engineering and Computing"},{"key":"2_CR14","doi-asserted-by":"crossref","unstructured":"Haines, D. (2011). Biophysics of radiofrequency lesion formation. In S. K. S. Huang & M. A. Wood (Ed.), Catheter ablation of cardiac arrhythmias, Second edition (pp 2\u201319). Philadelphia, PA: Elsevier Saunders.","DOI":"10.1016\/B978-1-4377-1368-8.00001-5"},{"key":"2_CR15","doi-asserted-by":"crossref","first-page":"1082","DOI":"10.1111\/j.1540-8159.2010.02799.x","volume":"33","author":"M Bosnos","year":"2010","unstructured":"Bosnos, M., Guillen-Rodriguez, J. M., He, D. S., & Marcus, F. I. (2010). Early assessment of biophysical parameters predicts lesion formation during RF energy delivery in vitro. Pace, 33, 1082\u20131088.","journal-title":"Pace"},{"key":"2_CR16","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1016\/j.hrthm.2010.06.014","volume":"7","author":"K Otomo","year":"2010","unstructured":"Otomo, K., Uno, K., Fujiwara, H., Isobe, M., & Iesaka, Y. (2010). Local unipolar and bipolar electrogram criteria for evaluating the transmurality of atrial ablation lesions at different catheter orientations relative to the endocardial surface. Heart Rhythm, 7, 1291\u20131300.","journal-title":"Heart Rhythm"},{"key":"2_CR17","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1161\/CIRCEP.113.001137","volume":"7","author":"W Ullah","year":"2014","unstructured":"Ullah, W., Hunter, R. J., Baker, V., Dhinoja, M. B., Sporton, S., Earley, M., et al. (2014). Target indices for clinical ablation in atrial fibrillation: insights from contact force, electrogram and biophysical parameter analysis. Circulation. Arrhythmia and Electrophysiology, 7, 63\u201368.","journal-title":"Circulation. Arrhythmia and Electrophysiology"},{"key":"2_CR18","volume":"8","author":"N Gallagher","year":"2013","unstructured":"Gallagher, N., Fear, E. C., Byrd, I. A., & Vigmond, E. J. (2013). Contact geometry affects lesion formation in radio-frequency cardiac catheter ablation. PLoS One, 8, e73242.","journal-title":"PLoS One"},{"key":"2_CR19","doi-asserted-by":"crossref","first-page":"746","DOI":"10.1161\/CIRCEP.113.978320","volume":"6","author":"H Nakagawa","year":"2013","unstructured":"Nakagawa, H., Kautzner, J., Natale, A., Peichl, P., Cihak, R., Wichterle, D., et al. (2013). Locations of high contact force during left atrial mapping in atrial fibrillation patients: electrogram amplitude and impedance are poor predictors of electrode-tissue contact force for ablation of atrial fibrillation. Circulation. Arrhythmia and Electrophysiology, 6, 746\u2013753.","journal-title":"Circulation. Arrhythmia and Electrophysiology"},{"key":"2_CR20","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/j.hrthm.2005.10.017","volume":"3","author":"CCE Lang","year":"2006","unstructured":"Lang, C. C. E., Gugliotta, F., Santinelli, V., Mesas, C., Tomita, T., Vicedomini, G., et al. (2006). Endocardial impedance mapping during circumferential pulmonary vein ablation of atrial fibrillation differentiates between atrial and venous tissue. Heart Rhythm, 3, 171\u2013178.","journal-title":"Heart Rhythm"},{"key":"2_CR21","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1161\/01.CIR.99.2.319","volume":"99","author":"H H\u00f8gh Petersen","year":"1999","unstructured":"H\u00f8gh Petersen, H., Chen, X., Pietersen, A., Svendsen, J. H., & Hauns\u00f8, S. (1999). Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium: impact of ablation site, electrode size, and convective cooling. Circulation, 99, 319\u2013325.","journal-title":"Circulation"},{"key":"2_CR22","doi-asserted-by":"crossref","first-page":"1038","DOI":"10.1111\/j.1540-8167.2010.01750.x","volume":"21","author":"DC Shah","year":"2010","unstructured":"Shah, D. C., Lambert, H., Nakagawa, H., Langenkamp, A., Aeby, N., & Leo, G. (2010). Area under the real-time contact force curve predicts radiofrequency lesion size in an in vitro contractile model. Journal of Cardiovascular Electrophysiology, 21, 1038\u20131043.","journal-title":"Journal of Cardiovascular Electrophysiology"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-015-0002-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10840-015-0002-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-015-0002-8","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,31]],"date-time":"2019-05-31T02:04:12Z","timestamp":1559268252000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10840-015-0002-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,4,30]]},"references-count":22,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2015,9]]}},"alternative-id":["2"],"URL":"https:\/\/doi.org\/10.1007\/s10840-015-0002-8","relation":{},"ISSN":["1383-875X","1572-8595"],"issn-type":[{"value":"1383-875X","type":"print"},{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,4,30]]}}}