{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T10:49:34Z","timestamp":1761562174724},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2016,11,22]],"date-time":"2016-11-22T00:00:00Z","timestamp":1479772800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"published-print":{"date-parts":[[2017,4]]},"DOI":"10.1007\/s10840-016-0199-1","type":"journal-article","created":{"date-parts":[[2016,11,22]],"date-time":"2016-11-22T05:44:46Z","timestamp":1479793486000},"page":"327-331","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["A 5-year clinical follow-up after duty-cycled phased RF ablation of paroxysmal atrial fibrillation"],"prefix":"10.1007","volume":"48","author":[{"given":"Antoine","family":"Lepillier","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xavier","family":"Copie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gilles","family":"Lascault","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Olivier","family":"Paziaud","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Olivier","family":"Piot","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2016,11,22]]},"reference":[{"issue":"4","key":"199_CR1","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1093\/europace\/eus027","volume":"14","author":"H Calkins","year":"2012","unstructured":"Calkins H, Kuck KH, Cappato R, Brugada J, Camm AJ, Chen SA, et al. HRS\/EHRA\/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design. Europace. 2012;14(4):528\u2013606.","journal-title":"Europace"},{"key":"199_CR2","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.1161\/01.CIR.0000157153.30978.67","volume":"111","author":"R Cappato","year":"2005","unstructured":"Cappato R, Calkins H, Chen SA, Davies W, Iesaka Y, Kalman J, et al. Worldwide survey on the methods, efficacy and safety of catheter ablation for human atrial fibrillation. Circulation. 2005;111:1100\u20135.","journal-title":"Circulation"},{"key":"199_CR3","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1056\/NEJM199809033391003","volume":"339","author":"M Ha\u00efssaguerre","year":"1998","unstructured":"Ha\u00efssaguerre M, Ja\u00efs P, Shah DC, Takahashi A, Hocini M, Quiniou G, et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med. 1998;339:659\u201366.","journal-title":"N Engl J Med"},{"issue":"6","key":"199_CR4","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1093\/europace\/eut398","volume":"16","author":"Y Greef De","year":"2014","unstructured":"De Greef Y, Buysschaert I, Schwagten B, Stockman D, Tavernier R, Duytschaever M. Duty-cycled multi-electrode radiofrequency vs. conventional irrigated point-by-point radiofrequency ablation for recurrent atrial fibrillation, comparative 3-year data. Europace. 2014;16(6):820\u20135.","journal-title":"Europace"},{"issue":"3","key":"199_CR5","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1016\/j.ijcard.2014.08.034","volume":"176","author":"P Gal","year":"2014","unstructured":"Gal P, Aarntzen AE, Smit JJ, Adiyaman A, Misier AR, Delnoy PP, et al. Conventional radiofrequency catheter ablation compared to multi-electrode ablation for atrial fibrillation. Int J Cardiol. 2014;176(3):891\u20135.","journal-title":"Int J Cardiol"},{"key":"199_CR6","doi-asserted-by":"crossref","first-page":"2355","DOI":"10.1161\/01.CIR.0000095796.45180.88","volume":"108","author":"H Oral","year":"2003","unstructured":"Oral H, Scharf C, Chugh A, Hall B, Cheung P, Good E, et al. Catheter ablation for paroxysmal atrial fibrillation: segmental pulmonary vein ostial ablation versus left atrial ablation. Circulation. 2003;108:2355\u201360.","journal-title":"Circulation"},{"key":"199_CR7","doi-asserted-by":"crossref","first-page":"2044","DOI":"10.1016\/j.jacc.2003.12.054","volume":"43","author":"K Nademanee","year":"2004","unstructured":"Nademanee K, McKenzie J, Kosar E, Schwab M, Sunsaneewitayakul B, Vasavakul T, et al. A new approach for catheter ablation of atrial fibrillation: mapping of the electrophysiologic substrate. J Am Coll Cardiol. 2004;43:2044\u201353.","journal-title":"J Am Coll Cardiol"},{"issue":"17","key":"199_CR8","doi-asserted-by":"crossref","first-page":"1667","DOI":"10.1161\/CIRCULATIONAHA.110.937953","volume":"122","author":"F Gaita","year":"2010","unstructured":"Gaita F, Caponi D, Pianelli M, Scaglione M, Toso E, Cesarani F, et al. Radiofrequency catheter ablation of atrial fibrillation: a cause of silent thromboembolism? Magnetic resonance imaging assessment of cerebral thromboembolism in patients undergoing ablation of atrial fibrillation. Circulation. 2010;122(17):1667\u201373.","journal-title":"Circulation"},{"issue":"25","key":"199_CR9","doi-asserted-by":"crossref","first-page":"2638","DOI":"10.1161\/CIRCULATIONAHA.113.006426","volume":"129","author":"L Biase Di","year":"2014","unstructured":"Di Biase L, Burkhardt JD, Santangeli P, Mohanty P, Sanchez JE, Horton R, et al. Periprocedural stroke and bleeding complications in patients undergoing catheter ablation of atrial fibrillation with different anticoagulation management: results from the role of Coumadin in preventing thromboembolism in atrial fibrillation (AF) patients undergoing catheter ablation (COMPARE) randomized trial. Circulation. 2014;129(25):2638\u201344.","journal-title":"Circulation"},{"issue":"5","key":"199_CR10","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1161\/CIRCEP.113.000612","volume":"6","author":"A Verma","year":"2013","unstructured":"Verma A, Debruyne P, Nardi S, Deneke T, De Greef Y, Spitzer S, et al. ERACE investigators. Evaluation and reduction of asymptomatic cerebral embolism in ablation of atrial fibrillation, but high prevalence of chronic silent infarction, results of the evaluation of reduction of asymptomatic cerebral embolism trial. Circ Arrhythm Electrophysiol. 2013;6(5):835\u201342.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"199_CR11","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1016\/j.jacc.2011.04.010","volume":"58","author":"C Herrera Sikl\u00f3dy","year":"2011","unstructured":"Herrera Sikl\u00f3dy C, Deneke T, Hocini M, Lehrmann H, Shin DI, Miyazaki S, et al. Incidence of asymptomatic intracranial embolic events after pulmonary vein isolation: comparison of different atrial fibrillation ablation technologies in a multicenter study. J Am Coll Cardiol. 2011;58:681\u20138.","journal-title":"J Am Coll Cardiol"},{"key":"199_CR12","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1111\/j.1540-8167.2011.02050.x","volume":"22","author":"F Gaita","year":"2011","unstructured":"Gaita F, Leclercq JF, Schumacher B, Scaglione M, Toso E, Halimi F, et al. Incidence of silent cerebral thromboembolic lesions after atrial fibrillation ablation may change according to technology used: comparison of irrigated radiofrequency, multipolar nonirrigated catheter and cryoballoon. J Cardiovasc Electrophysiol. 2011;22:961\u20138.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"5","key":"199_CR13","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1161\/CIRCEP.111.963397","volume":"4","author":"C Bary von","year":"2011","unstructured":"von Bary C, Weber S, Dornia C, Eissnert C, Fellner C, Latzin P, et al. Evaluation of pulmonary vein stenosis after pulmonary vein isolation using a novel circular mapping and ablation catheter (PVAC). Circ Arrhythm Electrophysiol. 2011;4(5):630\u20136.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"1","key":"199_CR14","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1007\/s10840-015-0028-y","volume":"44","author":"S Asbach","year":"2015","unstructured":"Asbach S, Schluermann F, Trolese L, Langer M, Bode C, Krauss T. Pulmonary vein stenosis after pulmonary vein isolation using duty-cycled unipolar\/bipolar radiofrequencyablation guided by intracardiac echocardiography. J Interv Card Electrophysiol. 2015;44(1):47\u201354.","journal-title":"J Interv Card Electrophysiol"},{"issue":"7","key":"199_CR15","doi-asserted-by":"crossref","first-page":"1521","DOI":"10.1016\/j.hrthm.2016.02.012","volume":"13","author":"M Hocini","year":"2016","unstructured":"Hocini M, Condie C, Stewart MT, Kirchhof N, Foell JD. Predictability of lesion durability for AF ablation using phased radiofrequency: power, temperature, and duration impact creation of transmural lesions. Heart Rhythm. 2016;13(7):1521\u20136.","journal-title":"Heart Rhythm"},{"issue":"5","key":"199_CR16","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1093\/europace\/euv385","volume":"18","author":"Y Greef De","year":"2016","unstructured":"De Greef Y, Dekker L, Boersma L, Murray S, Wieczorek M, Spitzer SG, et al. PRECISION GOLD investigators. Low rate of asymptomatic cerebral embolism and improved procedural efficiency with the novel pulmonary vein ablation catheter GOLD: results of the PRECISION GOLD trial. Europace. 2016;18(5):687\u201395.","journal-title":"Europace"},{"issue":"8","key":"199_CR17","doi-asserted-by":"crossref","first-page":"1596","DOI":"10.1016\/j.hrthm.2016.02.017","volume":"13","author":"K Wasmer","year":"2016","unstructured":"Wasmer K, Kr\u00fcsemann D, Leitz P, G\u00fcner F, Pott C, Zellerhoff S, et al. Lower rate of left atrial tachycardia after pulmonary vein isolation with PVAC versus irrigated-tip circumferential antral ablation. Heart Rhythm. 2016;13(8):1596\u2013601.","journal-title":"Heart Rhythm"},{"issue":"8","key":"199_CR18","doi-asserted-by":"crossref","first-page":"1170","DOI":"10.1093\/europace\/euv349","volume":"18","author":"R Wakili","year":"2016","unstructured":"Wakili R, Siebermair J, Fichtner S, Sinner MF, Klocker E, Olesch L, et al. One-year clinical outcome after ablation with a novel multipolar irrigated ablation catheter for treatment of atrial fibrillation: potential implications for clinical use. Europace. 2016;18(8):1170\u20138.","journal-title":"Europace"},{"issue":"6","key":"199_CR19","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1093\/europace\/euv258","volume":"18","author":"A Laish-Farkash","year":"2016","unstructured":"Laish-Farkash A, Khalameizer V, Fishman E, Cohen O, Yosefy C, Cohen I, et al. Safety, efficacy, and clinical applicability of pulmonary vein isolation with circular multi-electrode ablation systems: PVAC\u00ae vs. nMARQ\u2122 for atrial fibrillation ablation. Europace. 2016;18(6):807\u201314.","journal-title":"Europace"},{"issue":"7","key":"199_CR20","doi-asserted-by":"crossref","first-page":"724","DOI":"10.1111\/jce.12698","volume":"26","author":"S Mahida","year":"2015","unstructured":"Mahida S, Hooks DA, Nentwich K, Ng GA, Grimaldi M, Shin DI, et al. nMARQ ablation for atrial fibrillation: results from a multicenter study. J Cardiovasc Electrophysiol. 2015;26(7):724\u20139.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"8","key":"199_CR21","doi-asserted-by":"crossref","first-page":"1164","DOI":"10.1093\/europace\/euw048","volume":"18","author":"M Vurma","year":"2016","unstructured":"Vurma M, Dang L, Brunner-La Rocca HP, S\u00fctsch G, Attenhofer-Jost CH, Duru F, et al. Safety and efficacy of the nMARQ catheter for paroxysmal and persistent atrial fibrillation. Europace. 2016;18(8):1164\u20139.","journal-title":"Europace"},{"issue":"2","key":"199_CR22","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1016\/j.hrthm.2013.11.009","volume":"11","author":"J Hummel","year":"2014","unstructured":"Hummel J, Michaud G, Hoyt R, DeLurgio D, Rasekh A, Kusumoto F, et al. TTOP-AF investigators. Phased RF ablation in persistent atrial fibrillation. Heart Rhythm. 2014;11(2):202\u20139.","journal-title":"Heart Rhythm"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-016-0199-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10840-016-0199-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-016-0199-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,6,25]],"date-time":"2017-06-25T04:09:36Z","timestamp":1498363776000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10840-016-0199-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,11,22]]},"references-count":22,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017,4]]}},"alternative-id":["199"],"URL":"https:\/\/doi.org\/10.1007\/s10840-016-0199-1","relation":{},"ISSN":["1383-875X","1572-8595"],"issn-type":[{"value":"1383-875X","type":"print"},{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,11,22]]}}}