{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T10:48:16Z","timestamp":1782816496876,"version":"3.54.5"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2017,6,22]],"date-time":"2017-06-22T00:00:00Z","timestamp":1498089600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"published-print":{"date-parts":[[2017,9]]},"DOI":"10.1007\/s10840-017-0264-4","type":"journal-article","created":{"date-parts":[[2017,6,22]],"date-time":"2017-06-22T08:51:13Z","timestamp":1498121473000},"page":"299-306","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Elimination of the negative component of the unipolar electrogram as a local procedural endpoint during paroxysmal atrial fibrillation catheter ablation using contact-force sensing: the UNIFORCE study"],"prefix":"10.1007","volume":"49","author":[{"given":"Agust\u00edn","family":"Bortone","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philippe","family":"Lagrange","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bruno","family":"Cauchemez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cyril","family":"Durand","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierre","family":"Dieuzaide","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S\u00e9bastien","family":"Pr\u00e9vot","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexis","family":"Mechulan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Pambrun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruairidh","family":"Martin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pauline","family":"Parlier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandre","family":"Masse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eloi","family":"Marijon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Paul","family":"Albenque","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2017,6,22]]},"reference":[{"key":"264_CR1","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1016\/j.jacc.2010.05.061","volume":"57","author":"R Weerasooriya","year":"2011","unstructured":"Weerasooriya R, Khairy P, Litalien J, Macle L, Hocini M, Sacher F, et al. Catheter ablation for atrial fibrillation: are results maintained at 5 years of follow-up? J Am Coll Cardiol. 2011;57:160\u20136.","journal-title":"J Am Coll Cardiol"},{"key":"264_CR2","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1016\/j.hrthm.2010.06.014","volume":"7","author":"K Otomo","year":"2010","unstructured":"Otomo K, Uno K, Fujiwara H, Isobe M. Local unipolar and bipolar electrogram criteria for evaluating the transmurality of atrial ablation lesions at different catheter orientations relative to the endocardial surface. Heart Rhythm. 2010;7:1291\u2013300.","journal-title":"Heart Rhythm"},{"key":"264_CR3","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.1161\/CIRCEP.113.000749","volume":"6","author":"A Bortone","year":"2013","unstructured":"Bortone A, Appetiti A, Bouzeman A, Maupas E, Ciobotaru V, Boulenc JM, et al. Unipolar signal modification as a guide for lesion creation during radiofrequency application in the left atrium: prospective study in humans in the setting of paroxysmal atrial fibrillation catheter ablation. Circ Arrhythm Electrophysiol. 2013;6:1095\u2013102.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"264_CR4","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1161\/CIRCEP.115.002894","volume":"8","author":"A Bortone","year":"2015","unstructured":"Bortone A, Brault-Noble G, Appetiti A, Marijon E. Elimination of the negative component of the unipolar atrial electrogram as an in vivo marker of transmural lesion creation: acute study in canines. Circ Arrhythm Electrophysiol. 2015;8:905\u201311.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"264_CR5","doi-asserted-by":"crossref","first-page":"1038","DOI":"10.1111\/j.1540-8167.2010.01750.x","volume":"21","author":"DC Shah","year":"2010","unstructured":"Shah DC, Lambert H, Nakagawa H, Langenkamp A, Aeby N, Leo G. Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model. J Cardiovasc Electrophysiol. 2010;21:1038\u201343.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"264_CR6","doi-asserted-by":"crossref","first-page":"1789","DOI":"10.1016\/j.hrthm.2012.07.016","volume":"9","author":"VY Reddy","year":"2012","unstructured":"Reddy VY, Shah D, Kautzner J, Schmidt B, Saoudi N, Herrera C, et al. The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. Heart Rhythm. 2012;9:1789\u201395.","journal-title":"Heart Rhythm"},{"key":"264_CR7","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1093\/europace\/euu218","volume":"17","author":"R Provid\u00eancia","year":"2015","unstructured":"Provid\u00eancia R, Marijon E, Combes S, Bouzeman A, Jourda F, Khoueiry Z, et al. Higher contact-force values associated with better mid-term outcome of paroxysmal atrial fibrillation ablation using the SmartTouch\u2122 catheter. Europace. 2015;17:53\u201363.","journal-title":"Europace"},{"key":"264_CR8","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1111\/jce.12396","volume":"25","author":"CI Park","year":"2014","unstructured":"Park CI, Lehrmann H, Keyl C, Weber R, Schiebeling J, Allgeier J, et al. Mechanisms of pulmonary vein reconnection after radiofrequency ablation of atrial fibrillation: the deterministic role of contact force and interlesion distance. J Cardiovasc Electrophysiol. 2014;25:701\u20138.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"264_CR9","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1161\/CIRCEP.111.966523","volume":"5","author":"A Arujuna","year":"2012","unstructured":"Arujuna A, Karim R, Caulfield D, Knowles B, Rhode K, Schaeffter T, et al. Acute pulmonary vein isolation is achieved by a combination of reversible and irreversible atrial injury after catheter ablation. Evidence from magnetic resonance imaging. Circ Arrhythm Electrophysiol. 2012;5:691\u2013700.","journal-title":"Circ Arrhythm Electrophysiol."},{"key":"264_CR10","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1093\/europace\/eus048","volume":"14","author":"MA Miller","year":"2012","unstructured":"Miller MA, d'Avila A, Dukkipati SR, Koruth JS, Viles-Gonzalez J, Napolitano C, et al. Acute electrical isolation is a necessary but insufficient endpoint for achieving durable PV isolation: the importance of closing the visual gap. Europace. 2012;14:653\u201360.","journal-title":"Europace"},{"key":"264_CR11","doi-asserted-by":"publisher","unstructured":"Miyazaki S, Taniguchi H, Nakamura H, Hachiya H, Ichihara N, Araki M, et al. Adenosine triphospahte test after cryothermal pulmonary vein isolation: creating contiguous lesions is essential for eliminating dormant conduction. J Cardiovasc Electrophysiol. doi: 10.1111\/jce.12726 .","DOI":"10.1111\/jce.12726"},{"key":"264_CR12","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1161\/01.RES.48.1.39","volume":"48","author":"MS Spach","year":"1981","unstructured":"Spach MS, Miller WT, Geselowitz DB, Barr RC, Kootsey JM, Johnson EA. The discontinuous nature of propagation in normal canine cardiac muscle: evidence for recurrent discontinuities of intracellular resistance that affect the membrane currents. Circ Res. 1981;48:39\u201354.","journal-title":"Circ Res"},{"key":"264_CR13","first-page":"499","volume":"29","author":"MS Spach","year":"1971","unstructured":"Spach MS, Barr RC, Serwer GS, Johnson EA, Kootsey JM. Collision of excitation waves in the dog Purkinje system. Extracellular identification Circ Res. 1971;29:499\u2013511.","journal-title":"Extracellular identification Circ Res"},{"key":"264_CR14","doi-asserted-by":"publisher","unstructured":"Pambrun T, Roig J, Bouzeman A, Maupas E, Ciobotaru V, Boulenc JM, et al. Modification of the unipolar atrial electrogram as a local endpoint during common atrial flutter ablation. J Cardiovasc Electrophysiol. 2015; doi: 10.1111\/jce. 12754 .","DOI":"10.1111\/jce.%2012754"},{"key":"264_CR15","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/j.hrthm.2009.11.011","volume":"7","author":"D Steven","year":"2010","unstructured":"Steven D, Reddy VY, Inada K, Roberts-Thomson KC, Seiler J, Stevenson WG, et al. Loss of pace capture on the ablation line: a new marker for complete radiofrequency lesions to achieve pulmonary vein isolation. Heart Rhythm. 2010;7:323\u201330.","journal-title":"Heart Rhythm"},{"key":"264_CR16","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1161\/CIRCULATIONAHA.109.893107","volume":"121","author":"T Datino","year":"2010","unstructured":"Datino T, Macle L, Qi XY, Maguy A, Comtois P, Chartier D, et al. Mechanism by which adenosine restores conduction in dormant canine pulmonary veins. Circulation. 2010;121:963\u201372.","journal-title":"Circulation"},{"key":"264_CR17","first-page":"149","volume":"22","author":"N P\u00e9rez-Castellano","year":"2011","unstructured":"P\u00e9rez-Castellano N, Villacast\u00edn J, Salinas J, Vega M, Moreno J, Doblado M, et al. Epicardial connections between the pulmonary veins and left atrium: relevance for atrial fibrillation ablation. J Cardiovasc Electrophysiol. 2011;22:149\u201359.","journal-title":"J Cardiovasc Electrophysiol"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10840-017-0264-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-017-0264-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-017-0264-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,26]],"date-time":"2019-09-26T14:25:00Z","timestamp":1569507900000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10840-017-0264-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6,22]]},"references-count":17,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017,9]]}},"alternative-id":["264"],"URL":"https:\/\/doi.org\/10.1007\/s10840-017-0264-4","relation":{},"ISSN":["1383-875X","1572-8595"],"issn-type":[{"value":"1383-875X","type":"print"},{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,6,22]]}}}