{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T02:01:57Z","timestamp":1762999317149,"version":"3.37.3"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2017,12,11]],"date-time":"2017-12-11T00:00:00Z","timestamp":1512950400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"published-print":{"date-parts":[[2018,1]]},"DOI":"10.1007\/s10840-017-0301-3","type":"journal-article","created":{"date-parts":[[2017,12,11]],"date-time":"2017-12-11T08:06:22Z","timestamp":1512979582000},"page":"45-50","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Conception and validation of a protocol for reuse of non-irrigated electrophysiology catheters in a Brazilian teaching hospital"],"prefix":"10.1007","volume":"51","author":[{"given":"Mirtes Loeschner","family":"Leichsenring","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eliane Molina","family":"Psaltikidis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M\u00e1rcio Jansen","family":"de Oliveira Figueiredo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria Luiza","family":"Moretti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0588-4859","authenticated-orcid":false,"given":"Pl\u00ednio","family":"Trabasso","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2017,12,11]]},"reference":[{"doi-asserted-by":"crossref","unstructured":"Zipes DP, Akhtar M, Denes P, DeSanctis RW, Garsm Jr. A, Gettes LS, et al. Guidelines for Clinical Intracardiac Electrophysiologic Studies. A report of the American College of Cardiology\/American Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures (Subcommittee to Assess Clinical Intracardiac Electrophysiologic Studies). Circulation. 1989;80(6):1925-39. https:\/\/doi.org\/10.1161\/01.CIR.80.6.1925 .","key":"301_CR1","DOI":"10.1161\/01.CIR.80.6.1925"},{"issue":"8","key":"301_CR2","doi-asserted-by":"publisher","first-page":"1297","DOI":"10.1046\/j.1460-9592.2001.01297.x","volume":"24","author":"BD Lindsay","year":"2001","unstructured":"Lindsay BD, Kutalek SP, Cannom DS, Hammill SC, Naccarelli GV. Reprocessing of electrophysiology catheters: clinical studies, regulations and recommendations. A repor of the naspe task force on reprocessing of electrophysiological catheters. Pacing Clin Electrophysiol. 2001;24(8):1297\u2013305. https:\/\/doi.org\/10.1046\/j.1460-9592.2001.01297.x .","journal-title":"Pacing Clin Electrophysiol"},{"issue":"4","key":"301_CR3","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1016\/j.ijheh.2010.04.003","volume":"213","author":"W Popp","year":"2010","unstructured":"Popp W, Rasslan O, Unahalekhaka A, Brenner P, Fischnaller E, Fathy M, et al. What is the use? An international look at reuse of single-use medical devices. Int J Hyg Environ Health. 2010 July;213(4):302\u20137. https:\/\/doi.org\/10.1016\/j.ijheh.2010.04.003 .","journal-title":"Int J Hyg Environ Health"},{"unstructured":"Ministry of Health of Brazil Ag\u00eancia Nacional de Vigil\u00e2ncia Sanit\u00e1ria (ANVISA) Resolu\u00e7\u00e3o - RE N\u00b0 2.606 de 11 de agosto de 2006. Avaliable from: http:\/\/bvsms.saude.gov.br\/bvs\/saudelegis\/anvisa\/2006\/res2606_11_08_2006.html . Accessed October 20, 2013.","key":"301_CR4"},{"issue":"2","key":"301_CR5","first-page":"140","volume":"6","author":"F Tessarolo","year":"2009","unstructured":"Tessarolo F, Disertori M, Caola I, Guarrera GM, Capri S, Nollo G. Reprocessing single-use cardiac catheters for interventional cardiology. A cost-minimization model for estimating potential saving at departmental scale and national level. Ital J Public Health. 2009;6(2):140\u20139.","journal-title":"Ital J Public Health"},{"issue":"12","key":"301_CR6","doi-asserted-by":"publisher","first-page":"1558","DOI":"10.1016\/S0002-9149(97)00785-6","volume":"80","author":"M Ferrell","year":"1997","unstructured":"Ferrell M, Wolf CE, Ellenbogen KA, Wood MA, Clemo HF, Gilligan DM. Ethylene oxide on electrophysiology catheters following resterilization: implications for catheter reuse. Am J Cardiol. 1997;80(12):1558\u201361. https:\/\/doi.org\/10.1016\/S0002-9149(97)00785-6 .","journal-title":"Am J Cardiol"},{"key":"301_CR7","first-page":"556","volume":"41","author":"MJ Alfa","year":"2013","unstructured":"Alfa MJ. Monitoring and improving the effectiveness of cleaning medical and surgical devices. Am J Infect Control. 2013;41:556\u20139.","journal-title":"Am J Infect Control"},{"issue":"03","key":"301_CR8","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1086\/502190","volume":"24","author":"JD Druce","year":"2003","unstructured":"Druce JD, Russell JS, Birch CJ, Yates LA, Harper RW, Smolich JJA. Decontamination and sterilization protocol employed during reuse of cardiac electrophysiology catheters inactivates human immunodeficiency virus. Infect Control Hosp Epidemiol. 2003;24(03):184\u201390. https:\/\/doi.org\/10.1086\/502190 .","journal-title":"Infect Control Hosp Epidemiol"},{"key":"301_CR9","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1086\/502609","volume":"26","author":"JD Druce","year":"2005","unstructured":"Druce JD, Russell J, Birch CJ, Vickery K, Harper RW, Smolich JJ. Cleaning and sterilization protocol for reuse cardiac electrophysiology catheters inactivates hepatitis and coxsackie viruses. Infect Control Hosp Epidemiol. 2005;26:721\u20135.","journal-title":"Infect Control Hosp Epidemiol"},{"key":"301_CR10","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/j.ijheh.2006.05.001","volume":"209","author":"F Tessarolo","year":"2006","unstructured":"Tessarolo F, Caola I, Nollo G, Antolini R, Guarrera GM, Caciagli P. Efficiency in endotoxin removal by a reprocessing protocol for electrophysiology catheters based on hydrogen peroxide plasma sterilization. J Hyg Environ Health. 2006;209:557\u201365.","journal-title":"J Hyg Environ Health"},{"issue":"6","key":"301_CR11","doi-asserted-by":"publisher","first-page":"770","DOI":"10.1016\/S0002-9149(01)02353-0","volume":"89","author":"EA Grabsch","year":"2002","unstructured":"Grabsch EA, Grayson ML, Johnson PDR, Yates LA, Harper RW, Smolich JJ. Bactericidal efficacy of sterilizing protocol for reused cardiac electrophysiology catheters. Am J Cardio. 2002;89(6):770\u20132. https:\/\/doi.org\/10.1016\/S0002-9149(01)02353-0 .","journal-title":"Am J Cardio"},{"issue":"4","key":"301_CR12","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1093\/jaoac\/92.4.1165","volume":"92","author":"BR Lester","year":"2009","unstructured":"Lester BR, Boser NP, Miller K, Schnapf M, Jacques BA, Sullivan BF, et al. Reprocessing and sterilization os single-use electrophysiological catheters: removal of organic carbon and protein surface residues. J AOAC Int. 2009;92(4):1165\u201373.","journal-title":"J AOAC Int"},{"issue":"2","key":"301_CR13","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1007\/s10840-006-9055-z","volume":"17","author":"BR Lester","year":"2006","unstructured":"Lester BR, Alexander AA, Miller K, Boser NP, Sullivan BF, Brucker GG. Comparasion of performance characteristics between new and reprocessed electrophysiology catheters. J Interv Card Electrophysiol. 2006;17(2):77\u201383. https:\/\/doi.org\/10.1007\/s10840-006-9055-z .","journal-title":"J Interv Card Electrophysiol"},{"unstructured":"Ministry of Health of Brazil. Agencia Nacional de Vigilancia Sanit\u00e1ria (ANVISA). Resolu\u00e7\u00e3o - RDC n\u00b015 de 15 de mar\u00e7o de 2012. Avaliable from: www.anvisa.gov.br\/hotsite\/seguran\u00e7adopaciente\/documentos\/rdcs\/RDC%20N\u00b0%2015-2012.pdf . Accessed September 10, 2013.","key":"301_CR14"},{"issue":"12","key":"301_CR15","doi-asserted-by":"publisher","first-page":"1385","DOI":"10.1086\/508829","volume":"27","author":"F Tessarolo","year":"2006","unstructured":"Tessarolo F, Caola I, Caciagli P, Guarrera GM, Nollo G. Sterility and microbiological assessment of reused single-use cardiac electrophysiology catheters. Infect Control Hosp Epidemiol. 2006;27(12):1385\u201392. https:\/\/doi.org\/10.1086\/508829 .","journal-title":"Infect Control Hosp Epidemiol"},{"unstructured":"Ministry of Health of Brazil. Portaria Interministerial MS\/MET n\u00b0 482 de 16 de abril de 1999. Aviable from: www.prosaude.org.br\/legisla\u00e7\u00e3o_2013\/legisla\u00e7\u00e3o_textos\/portaria_482.pdf .. Accessed September 12, 2013.","key":"301_CR16"},{"issue":"4","key":"301_CR17","first-page":"774","volume":"52","author":"S Lerouge","year":"2000","unstructured":"Lerouge S, Guinot G, Tabrizian M, Ferrier D, Yagoubi N, Yahia L. Plasma-based sterilization; effect on surface and bulk properties and hydrolytic stability of reprocessed polyurethane electrophysiology catheters. Int J Biomater Res Eng. 2000;52(4):774\u201382.","journal-title":"Int J Biomater Res Eng"},{"issue":"1-4","key":"301_CR18","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/j.apsusc.2004.05.223","volume":"238","author":"F Tessarolo","year":"2004","unstructured":"Tessarolo F, Ferrari P, Silvia B, Motta A, Migliaresi C, Zennaro L, et al. Evaluation and quantification of reprocessing modification in single-use devices in interventional cardiology. Appl Surf Sci. 2004;238(1-4):341\u20136. https:\/\/doi.org\/10.1016\/j.apsusc.2004.05.223 .","journal-title":"Appl Surf Sci"},{"issue":"1","key":"301_CR19","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1023\/A:1020820200112","volume":"7","author":"I Ayzman","year":"2002","unstructured":"Ayzman I, Dibs SR, Goldberger J, Passman R, Kadish A. In Vitro performance characteristics of reused ablation catheters. J Interv Card Electrophysiol. 2002;7(1):53\u20139. https:\/\/doi.org\/10.1023\/A:1020820200112 .","journal-title":"J Interv Card Electrophysiol"},{"issue":"1","key":"301_CR20","first-page":"3","volume":"12","author":"S Lerouge","year":"2002","unstructured":"Lerouge S, Tabrizian M, Wertheimer MR, Marchand R, Yahia L. Safety of plasma-based sterilization: surface modifications of polymeric medical devices induced by Sterrad and Plazlyte processes. Biomed Mater Eng. 2002;12(1):3\u201313.","journal-title":"Biomed Mater Eng"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10840-017-0301-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-017-0301-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-017-0301-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,10,24]],"date-time":"2020-10-24T03:20:58Z","timestamp":1603509658000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10840-017-0301-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,12,11]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,1]]}},"alternative-id":["301"],"URL":"https:\/\/doi.org\/10.1007\/s10840-017-0301-3","relation":{},"ISSN":["1383-875X","1572-8595"],"issn-type":[{"type":"print","value":"1383-875X"},{"type":"electronic","value":"1572-8595"}],"subject":[],"published":{"date-parts":[[2017,12,11]]}}}