{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,5]],"date-time":"2026-03-05T22:52:50Z","timestamp":1772751170311,"version":"3.50.1"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2018,3,13]],"date-time":"2018-03-13T00:00:00Z","timestamp":1520899200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"University Medical Center Rotterdam"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"published-print":{"date-parts":[[2018,7]]},"DOI":"10.1007\/s10840-018-0354-y","type":"journal-article","created":{"date-parts":[[2018,3,13]],"date-time":"2018-03-13T00:31:03Z","timestamp":1520901063000},"page":"203-208","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["Value of implantable loop recorders in patients with structural or electrical heart disease"],"prefix":"10.1007","volume":"52","author":[{"given":"Rafi","family":"Sakhi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dominic A. M. J.","family":"Theuns","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rohit E.","family":"Bhagwandien","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michelle","family":"Michels","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arend F. L.","family":"Schinkel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tamas","family":"Szili-Torok","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F.","family":"Zijlstra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jolien W.","family":"Roos-Hesselink","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4520-2725","authenticated-orcid":false,"given":"Sing-Chien","family":"Yap","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,3,13]]},"reference":[{"issue":"2","key":"354_CR1","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1093\/europace\/euq418","volume":"13","author":"N Edvardsson","year":"2011","unstructured":"Edvardsson N, Frykman V, van Mechelen R, Mitro P, Mohii-Oskarsson A, Pasquie JL, et al. Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: results from the PICTURE registry. Europace. 2011;13(2):262\u20139.","journal-title":"Europace"},{"issue":"3","key":"354_CR2","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1093\/eurheartj\/ehi602","volume":"27","author":"DJ Farwell","year":"2006","unstructured":"Farwell DJ, Freemantle N, Sulke N. The clinical impact of implantable loop recorders in patients with syncope. Eur Heart J. 2006;27(3):351\u20136.","journal-title":"Eur Heart J"},{"issue":"19","key":"354_CR3","doi-asserted-by":"publisher","first-page":"1951","DOI":"10.1016\/j.jacc.2007.02.036","volume":"49","author":"F Giada","year":"2007","unstructured":"Giada F, Gulizia M, Francese M, Croci F, Santangelo L, Santomauro M, et al. Recurrent unexplained palpitations (RUP) study: comparison of implantable loop recorder versus conventional diagnostic strategy. J Am Coll Cardiol. 2007;49(19):1951\u20136.","journal-title":"J Am Coll Cardiol"},{"issue":"26","key":"354_CR4","doi-asserted-by":"publisher","first-page":"2478","DOI":"10.1056\/NEJMoa1313600","volume":"370","author":"T Sanna","year":"2014","unstructured":"Sanna T, Diener HC, Passman RS, Di Lazzaro V, Bernstein RA, Morillo CA, et al. Cryptogenic stroke and underlying atrial fibrillation. N Engl J Med. 2014;370(26):2478\u201386.","journal-title":"N Engl J Med"},{"issue":"7","key":"354_CR5","doi-asserted-by":"publisher","first-page":"1059","DOI":"10.1093\/europace\/eut187","volume":"15","author":"A Proclemer","year":"2013","unstructured":"Proclemer A, Lewalter T, Bongiorni MG, Svendsen JH, Pison L, Lundqvist CB, et al. Screening and risk evaluation for sudden cardiac death in ischaemic and non-ischaemic cardiomyopathy: results of the European Heart Rhythm Association survey. Europace. 2013;15(7):1059\u201362.","journal-title":"Europace"},{"issue":"5","key":"354_CR6","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1093\/europace\/eup097","volume":"11","author":"M Brignole","year":"2009","unstructured":"Brignole M, Vardas P, Hoffman E, Huikuri H, Moya A, Ricci R, et al. Indications for the use of diagnostic implantable and external ECG loop recorders. Europace. 2009;11(5):671\u201387.","journal-title":"Europace"},{"issue":"21","key":"354_CR7","doi-asserted-by":"publisher","first-page":"2631","DOI":"10.1093\/eurheartj\/ehp298","volume":"30","author":"A Moya","year":"2009","unstructured":"Moya A, Sutton R, Ammirati F, Blanc JJ, Brignole M, Dahm JB, et al. Guidelines for the diagnosis and management of syncope (version 2009). Eur Heart J. 2009;30(21):2631\u201371.","journal-title":"Eur Heart J"},{"issue":"4","key":"354_CR8","first-page":"665","volume":"19","author":"C Antzelevitch","year":"2017","unstructured":"Antzelevitch C, Yan GX, Ackerman MJ, Borggrefe M, Corrado D, Guo J, et al. J-wave syndromes expert consensus conference report: emerging concepts and gaps in knowledge. Europace. 2017;19(4):665\u201394.","journal-title":"Europace"},{"issue":"4","key":"354_CR9","doi-asserted-by":"publisher","first-page":"e17","DOI":"10.1136\/hrt.2007.116616","volume":"94","author":"T Pezawas","year":"2008","unstructured":"Pezawas T, Stix G, Kastner J, Schneider B, Wolzt M, Schmidinger H. Implantable loop recorder in unexplained syncope: classification, mechanism, transient loss of consciousness and role of major depressive disorder in patients with and without structural heart disease. Heart. 2008;94(4):e17.","journal-title":"Heart"},{"issue":"13","key":"354_CR10","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.1016\/j.ehj.2004.05.013","volume":"25","author":"A Solano","year":"2004","unstructured":"Solano A, Menozzi C, Maggi R, Donateo P, Bottoni N, Lolli G, et al. Incidence, diagnostic yield and safety of the implantable loop-recorder to detect the mechanism of syncope in patients with and without structural heart disease. Eur Heart J. 2004;25(13):1116\u20139.","journal-title":"Eur Heart J"},{"issue":"41","key":"354_CR11","doi-asserted-by":"publisher","first-page":"2793","DOI":"10.1093\/eurheartj\/ehv316","volume":"36","author":"SG Priori","year":"2015","unstructured":"Priori SG, Blomstrom-Lundqvist C, Mazzanti A, Blom N, Borggrefe M, Camm J, et al. ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: the Task Force for the Management of Patients with Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death of the European Society of Cardiology (ESC). Endorsed by: Association for European Paediatric and Congenital Cardiology (AEPC). Eur Heart J. 2015;36(41):2793\u2013867.","journal-title":"Eur Heart J"},{"issue":"Suppl B","key":"354_CR12","doi-asserted-by":"publisher","first-page":"71B","DOI":"10.1016\/S0828-282X(07)71014-0","volume":"23","author":"J Champagne","year":"2007","unstructured":"Champagne J, Philippon F, Gilbert M, Molin F, Blier L, Nault I, et al. The Brugada syndrome in Canada: a unique French-Canadian experience. Can J Cardiol. 2007;23(Suppl B):71B\u20135B.","journal-title":"Can J Cardiol"},{"issue":"6","key":"354_CR13","doi-asserted-by":"publisher","first-page":"898","DOI":"10.1093\/europace\/eur319","volume":"14","author":"M Kubala","year":"2012","unstructured":"Kubala M, Aissou L, Traulle S, Gugenheim AL, Hermida JS. Use of implantable loop recorders in patients with Brugada syndrome and suspected risk of ventricular arrhythmia. Europace. 2012;14(6):898\u2013902.","journal-title":"Europace"},{"issue":"8","key":"354_CR14","doi-asserted-by":"publisher","first-page":"1272","DOI":"10.1016\/j.hrthm.2012.04.013","volume":"9","author":"F Sacher","year":"2012","unstructured":"Sacher F, Arsac F, Wilton SB, Derval N, Denis A, de Guillebon M, et al. Syncope in Brugada syndrome patients: prevalence, characteristics, and outcome. Heart Rhythm. 2012;9(8):1272\u20139.","journal-title":"Heart Rhythm"},{"issue":"6","key":"354_CR15","doi-asserted-by":"publisher","first-page":"e003632","DOI":"10.1161\/JAHA.116.003632","volume":"5","author":"JN Avari Silva","year":"2016","unstructured":"Avari Silva JN, Bromberg BI, Emge FK, Bowman TM, Van Hare GF. Implantable loop recorder monitoring for refining management of children with inherited arrhythmia syndromes. J Am Heart Assoc. 2016;5(6):e003632.","journal-title":"J Am Heart Assoc"},{"issue":"3","key":"354_CR16","doi-asserted-by":"publisher","first-page":"338","DOI":"10.1111\/j.1540-8159.2008.00995.x","volume":"31","author":"PA Frangini","year":"2008","unstructured":"Frangini PA, Cecchin F, Jordao L, Martuscello M, Alexander ME, Triedman JK, et al. How revealing are insertable loop recorders in pediatrics? Pacing Clin Electrophysiol. 2008;31(3):338\u201343.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"2","key":"354_CR17","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.ijcard.2011.05.082","volume":"163","author":"C Stollberger","year":"2013","unstructured":"Stollberger C, Keller H, Steger C, Finsterer J. Implantable loop-recorders in myopathic and non-myopathic patients with left ventricular hypertrabeculation\/noncompaction. Int J Cardiol. 2013;163(2):146\u20138.","journal-title":"Int J Cardiol"},{"issue":"3","key":"354_CR18","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1093\/europace\/eun380","volume":"11","author":"D Kenny","year":"2009","unstructured":"Kenny D, Chakrabarti S, Ranasinghe A, Chambers A, Martin R, Stuart G. Single-centre use of implantable loop recorders in patients with congenital heart disease. Europace. 2009;11(3):303\u20137.","journal-title":"Europace"},{"issue":"2","key":"354_CR19","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1067\/mhj.2002.120157","volume":"143","author":"S Sanatani","year":"2002","unstructured":"Sanatani S, Peirone A, Chiu C, Human DG, Gross GJ, Hamilton RM. Use of an implantable loop recorder in the evaluation of children with congenital heart disease. Am Heart J. 2002;143(2):366\u201372.","journal-title":"Am Heart J"},{"issue":"2","key":"354_CR20","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1016\/j.amjcard.2016.04.033","volume":"118","author":"F Weidemann","year":"2016","unstructured":"Weidemann F, Maier SK, Stork S, Brunner T, Liu D, Hu K, et al. Usefulness of an implantable loop recorder to detect clinically relevant arrhythmias in patients with advanced Fabry cardiomyopathy. Am J Cardiol. 2016;118(2):264\u201374.","journal-title":"Am J Cardiol"},{"issue":"1","key":"354_CR21","first-page":"37","volume":"66","author":"C Schernthaner","year":"2008","unstructured":"Schernthaner C, Danmayr F, Altenberger J, Pichler M, Strohmer B. High incidence of tachyarrhythmias detected by an implantable loop recorder in patients with unexplained syncope. Kardiol Pol. 2008;66(1):37\u201344. discussion 5-6","journal-title":"Kardiol Pol"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10840-018-0354-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-018-0354-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-018-0354-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,3,12]],"date-time":"2019-03-12T20:39:33Z","timestamp":1552423173000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10840-018-0354-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3,13]]},"references-count":21,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018,7]]}},"alternative-id":["354"],"URL":"https:\/\/doi.org\/10.1007\/s10840-018-0354-y","relation":{},"ISSN":["1383-875X","1572-8595"],"issn-type":[{"value":"1383-875X","type":"print"},{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,3,13]]},"assertion":[{"value":"8 January 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 March 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 March 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"All patients gave informed consent for the implantation procedure.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}