{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,14]],"date-time":"2025-12-14T09:28:49Z","timestamp":1765704529063,"version":"3.37.3"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2019,7,19]],"date-time":"2019-07-19T00:00:00Z","timestamp":1563494400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,7,19]],"date-time":"2019-07-19T00:00:00Z","timestamp":1563494400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"published-print":{"date-parts":[[2020,3]]},"DOI":"10.1007\/s10840-019-00591-2","type":"journal-article","created":{"date-parts":[[2019,7,19]],"date-time":"2019-07-19T04:43:11Z","timestamp":1563511391000},"page":"251-259","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Porous tip contact force\u2013sensing catheters for pulmonary vein isolation: performance in a clinical routine setting"],"prefix":"10.1007","volume":"57","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6823-3060","authenticated-orcid":false,"given":"Tobias","family":"Plenge","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan-Hendrik","family":"van den Bruck","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jakob","family":"L\u00fcker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arian","family":"Sultan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel","family":"Steven","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,7,19]]},"reference":[{"key":"591_CR1","doi-asserted-by":"publisher","first-page":"e275","DOI":"10.1016\/j.hrthm.2017.05.012","volume":"14","author":"H Calkins","year":"2017","unstructured":"Calkins H, Hindricks G, Cappato R, Kim YH, Saad EB, Aguinaga L, et al. 2017 HRS\/EHRA\/ECAS\/APHRS\/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. Heart Rhythm. 2017;14:e275\u2013444. \nhttps:\/\/doi.org\/10.1016\/j.hrthm.2017.05.012\n\n.","journal-title":"Heart Rhythm"},{"key":"591_CR2","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1007\/s10840-014-9874-2","volume":"39","author":"L Sciarra","year":"2014","unstructured":"Sciarra L, Golia P, Natalizia A, de Ruvo E, Dottori S, Scar\u00e0 A, et al. Which is the best catheter to perform atrial fibrillation ablation? A comparison between standard ThermoCool, SmartTouch, and Surround Flow catheters. J Interv Card Electrophysiol. 2014;39:193\u2013200. \nhttps:\/\/doi.org\/10.1007\/s10840-014-9874-2\n\n.","journal-title":"J Interv Card Electrophysiol"},{"key":"591_CR3","doi-asserted-by":"publisher","first-page":"1778","DOI":"10.1056\/NEJMoa0708234","volume":"359","author":"MN Khan","year":"2008","unstructured":"Khan MN, Ja\u00efs P, Cummings J, di Biase L, Sanders P, Martin DO, et al. Pulmonary-vein isolation for atrial fibrillation in patients with heart failure. N Engl J Med. 2008;359:1778\u201385. \nhttps:\/\/doi.org\/10.1056\/NEJMoa0708234\n\n.","journal-title":"N Engl J Med"},{"key":"591_CR4","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1111\/jce.12835","volume":"27","author":"JR Winterfield","year":"2016","unstructured":"Winterfield JR, Jensen J, Gilbert T, et al. Lesion size and safety comparison between the novel flex tip on the FlexAbility ablation catheter and the solid tips on the thermo cool and thermo cool SFl. J Cardiovasc Electrophysiol. 2016;27:102\u20139. \nhttps:\/\/doi.org\/10.1111\/jce.12835\n\n.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"591_CR5","doi-asserted-by":"publisher","first-page":"1328","DOI":"10.1111\/jce.12221","volume":"24","author":"CI Park","year":"2013","unstructured":"Park CI, Lehrmann H, Keyl C, et al. Enhanced efficiency of a novel porous tip irrigated RF ablation catheter for pulmonary vein isolation. J Cardiovasc Electrophysiol. 2013;24:1328\u201335. \nhttps:\/\/doi.org\/10.1111\/jce.12221\n\n.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"591_CR6","doi-asserted-by":"publisher","first-page":"852","DOI":"10.1111\/jce.12403","volume":"25","author":"SR Oza","year":"2014","unstructured":"Oza SR, Hunter TD, Biviano AB, et al. Acute safety of an open-irrigated ablation catheter with 56-hole porous tip for radiofrequency ablation of paroxysmal atrial fibrillation: analysis from 2 observational registry studies. J Cardiovasc Electrophysiol. 2014;25:852\u20138. \nhttps:\/\/doi.org\/10.1111\/jce.12403\n\n.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"591_CR7","doi-asserted-by":"publisher","first-page":"994","DOI":"10.1111\/jce.13264","volume":"28","author":"H Lin","year":"2017","unstructured":"Lin H, Chen Y-H, Hou J-W, Lu ZY, Xiang Y, Li YG. Role of contact force-guided radiofrequency catheter ablation for treatment of atrial fibrillation: a systematic review and meta-analysis. J Cardiovasc Electrophysiol. 2017;28:994\u20131005. \nhttps:\/\/doi.org\/10.1111\/jce.13264\n\n.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"591_CR8","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1093\/europace\/euv206","volume":"18","author":"T Itoh","year":"2016","unstructured":"Itoh T, Kimura M, Tomita H, Sasaki S, Owada S, Horiuchi D, et al. Reduced residual conduction gaps and favourable outcome in contact force-guided circumferential pulmonary vein isolation. Europace. 2016;18:531\u20137. \nhttps:\/\/doi.org\/10.1093\/europace\/euv206\n\n.","journal-title":"Europace"},{"key":"591_CR9","doi-asserted-by":"publisher","first-page":"1919","DOI":"10.1016\/j.hrthm.2014.07.033","volume":"11","author":"JG Andrade","year":"2014","unstructured":"Andrade JG, Monir G, Pollak SJ, Khairy P, Dubuc M, Roy D, et al. Pulmonary vein isolation using \u201ccontact force\u201d ablation: the effect on dormant conduction and long-term freedom from recurrent atrial fibrillation\u2014a prospective study. Hear Rhythm. 2014;11:1919\u201324. \nhttps:\/\/doi.org\/10.1016\/j.hrthm.2014.07.033\n\n.","journal-title":"Hear Rhythm"},{"key":"591_CR10","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1161\/CIRCULATIONAHA.114.014092","volume":"132","author":"VY Reddy","year":"2015","unstructured":"Reddy VY, Dukkipati SR, Neuzil P, Natale A, Albenque JP, Kautzner J, et al. Randomized, controlled trial of the safety and effectiveness of a contact force-sensing irrigated catheter for ablation of paroxysmal atrial fibrillation: results of the TactiCath contact force ablation catheter study for atrial fibrillation (TOCCASTAR) S. Circulation. 2015;132:907\u201315. \nhttps:\/\/doi.org\/10.1161\/CIRCULATIONAHA.114.014092\n\n.","journal-title":"Circulation"},{"key":"591_CR11","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1016\/j.jacc.2014.04.072","volume":"64","author":"A Natale","year":"2014","unstructured":"Natale A, Reddy VY, Monir G, Wilber DJ, Lindsay BD, McElderry HT, et al. Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial. J Am Coll Cardiol. 2014;64:647\u201356. \nhttps:\/\/doi.org\/10.1016\/j.jacc.2014.04.072\n\n.","journal-title":"J Am Coll Cardiol"},{"key":"591_CR12","doi-asserted-by":"publisher","first-page":"2858","DOI":"10.1093\/eurheartj\/ehw285","volume":"37","author":"KH Kuck","year":"2016","unstructured":"Kuck KH, F\u00fcrnkranz A, Chun KRJ, Metzner A, Ouyang F, Schl\u00fcter M, et al. Cryoballoon or radiofrequency ablation for symptomatic paroxysmal atrial fibrillation: reintervention, rehospitalization, and quality-of-life outcomes in the FIRE and ICE trial. Eur Heart J. 2016;37:2858\u201365. \nhttps:\/\/doi.org\/10.1093\/eurheartj\/ehw285\n\n.","journal-title":"Eur Heart J"},{"key":"591_CR13","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1056\/NEJMoa1707855","volume":"378","author":"NF Marrouche","year":"2018","unstructured":"Marrouche NF, Brachmann J, Andresen D, Siebels J, Boersma L, Jordaens L, et al. Catheter ablation for atrial fibrillation with heart failure. N Engl J Med. 2018;378:417\u201327. \nhttps:\/\/doi.org\/10.1056\/NEJMoa1707855\n\n.","journal-title":"N Engl J Med"},{"key":"591_CR14","doi-asserted-by":"publisher","first-page":"2767","DOI":"10.1093\/eurheartj\/ehy379","volume":"39","author":"A Tofield","year":"2018","unstructured":"Tofield A, Heart Rhythm Society, Sessions AS, et al. The CABANA trial: a first glance at an important study. Eur Heart J. 2018;39:2767\u201379. \nhttps:\/\/doi.org\/10.1093\/eurheartj\/ehy379\n\n.","journal-title":"Eur Heart J"},{"key":"591_CR15","doi-asserted-by":"publisher","first-page":"2743","DOI":"10.1016\/j.jacc.2015.09.088","volume":"66","author":"J Vogler","year":"2015","unstructured":"Vogler J, Willems S, Sultan A, Schreiber D, L\u00fcker J, Servatius H, et al. Pulmonary vein isolation versus defragmentation the CHASE-AF Clinical Trial. J Am Coll Cardiol. 2015;66:2743\u201352. \nhttps:\/\/doi.org\/10.1016\/j.jacc.2015.09.088\n\n.","journal-title":"J Am Coll Cardiol"},{"key":"591_CR16","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1007\/s10840-013-9864-9","volume":"39","author":"E Anter","year":"2014","unstructured":"Anter E, Contreras-Valdes FM, Shvilkin A, Tschabrunn CM, Josephson ME. Acute pulmonary vein reconnection is a predictor of atrial fibrillation recurrence following pulmonary vein isolation. J Interv Card Electrophysiol. 2014;39:225\u201332. \nhttps:\/\/doi.org\/10.1007\/s10840-013-9864-9\n\n.","journal-title":"J Interv Card Electrophysiol"},{"key":"591_CR17","doi-asserted-by":"publisher","first-page":"738","DOI":"10.1007\/s00392-016-0980-2","volume":"105","author":"K Wasmer","year":"2016","unstructured":"Wasmer K, Dechering DG, K\u00f6be J, M\u00f6nnig G, Pott C, Frommeyer G, et al. Pulmonary vein reconnection and arrhythmia progression after antral linear catheter ablation of paroxysmal and persistent atrial fibrillation. Clin Res Cardiol. 2016;105:738\u201343. \nhttps:\/\/doi.org\/10.1007\/s00392-016-0980-2\n\n.","journal-title":"Clin Res Cardiol"},{"key":"591_CR18","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1016\/j.jacep.2016.07.014","volume":"2","author":"VY Reddy","year":"2016","unstructured":"Reddy VY, Pollak S, Lindsay BD, McElderry HT, Natale A, Kantipudi C, et al. Relationship between catheter stability and 12-month success after pulmonary vein isolation: A Subanalysis of the SMART-AF Trial. JACC Clin Electrophysiol. 2016;2:691\u20139. \nhttps:\/\/doi.org\/10.1016\/j.jacep.2016.07.014\n\n.","journal-title":"JACC Clin Electrophysiol"},{"key":"591_CR19","doi-asserted-by":"publisher","first-page":"1761","DOI":"10.1016\/j.hrthm.2016.05.011","volume":"13","author":"W Ullah","year":"2016","unstructured":"Ullah W, McLean A, Tayebjee MH, Gupta D, Ginks MR, Haywood GA, et al. Randomized trial comparing pulmonary vein isolation using the SmartTouch catheter with or without real-time contact force data. Hear Rhythm. 2016;13:1761\u20137. \nhttps:\/\/doi.org\/10.1016\/j.hrthm.2016.05.011\n\n.","journal-title":"Hear Rhythm"},{"key":"591_CR20","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1111\/jce.13100","volume":"28","author":"F Bourier","year":"2017","unstructured":"Bourier F, Gianni C, Dare M, et al. Fiberoptic contact-force sensing electrophysiological catheters: how precise is the technology? J Cardiovasc Electrophysiol. 2017;28:109\u201314. \nhttps:\/\/doi.org\/10.1111\/jce.13100\n\n.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"591_CR21","doi-asserted-by":"publisher","first-page":"1038","DOI":"10.1111\/j.1540-8167.2010.01750.x","volume":"21","author":"DC Shah","year":"2010","unstructured":"Shah DC, Lambert H, Nakagawa H, et al. Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model. J Cardiovasc Electrophysiol. 2010;21:1038\u201343. \nhttps:\/\/doi.org\/10.1111\/j.1540-8167.2010.01750.x\n\n.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"591_CR22","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1161\/CIRCEP.108.803650","volume":"1","author":"K Yokoyama","year":"2008","unstructured":"Yokoyama K, Nakagawa H, Shah DC, Lambert H, Leo G, Aeby N, et al. Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus. Circ Arrhythm Electrophysiol. 2008;1:354\u201362. \nhttps:\/\/doi.org\/10.1161\/CIRCEP.108.803650\n\n.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"591_CR23","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1111\/j.1540-8167.1991.tb01353.x","volume":"2","author":"DA Haines","year":"1991","unstructured":"Haines DA. Determinants of lesion size during radiofrequency catheter ablation: the role of electrode tissue contact pressure and duration of energy delivery. J Cardiovasc Electrophysiol. 1991;2:509\u201315.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"591_CR24","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1046\/j.1540-8167.2002.01067.x","volume":"13","author":"L Macle","year":"2002","unstructured":"Macle L, Jais P, Weerasooriya R, et al. Irrigated-tip catheter ablation of pulmonary veins for treatment of atrial fibrillation. J Cardiovasc Electrophysiol. 2002;13:1067\u201373.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"591_CR25","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1016\/S0735-1097(02)01972-1","volume":"40","author":"NF Marrouche","year":"2002","unstructured":"Marrouche NF, Dresing T, Cole C, Bash D, Saad E, Balaban K, et al. Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation: Impact of different catheter technologies. J Am Coll Cardiol. 2002;40:464\u201374. \nhttps:\/\/doi.org\/10.1016\/S0735-1097(02)01972-1\n\n.","journal-title":"J Am Coll Cardiol"},{"key":"591_CR26","doi-asserted-by":"publisher","first-page":"956","DOI":"10.1111\/jce.12721","volume":"26","author":"C Theis","year":"2015","unstructured":"Theis C, Rostock T, Mollnau H, et al. The incidence of audible steam pops is increased and unpredictable with the ThermoCool\u00ae surround flow catheter during left atrial catheter ablation: a prospective observational study. J Cardiovasc Electrophysiol. 2015;26:956\u201362. \nhttps:\/\/doi.org\/10.1111\/jce.12721\n\n.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"591_CR27","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1007\/s00392-018-1270-y","volume":"107","author":"T Maurer","year":"2018","unstructured":"Maurer T, Rottner L, Makimoto H, Reissmann B, Heeger CH, Lemes C, et al. The best of two worlds? Pulmonary vein isolation using a novel radiofrequency ablation catheter incorporating contact force sensing technology and 56-hole porous tip irrigation. Clin Res Cardiol. 2018;107:1003\u201312. \nhttps:\/\/doi.org\/10.1007\/s00392-018-1270-y\n\n.","journal-title":"Clin Res Cardiol"},{"key":"591_CR28","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1093\/europace\/eux264","volume":"20","author":"LA Chinitz","year":"2017","unstructured":"Chinitz LA, Melby DP, Marchlinski FE, Delaughter C, Fishel RS, Monir G, et al. Safety and efficiency of porous-tip contact-force catheter for drug-refractory symptomatic paroxysmal atrial fibrillation ablation: results from the SMART SF trial. EP Eur. 2017;20:1\u20139. \nhttps:\/\/doi.org\/10.1093\/europace\/eux264\n\n.","journal-title":"EP Eur"},{"key":"591_CR29","doi-asserted-by":"publisher","first-page":"1317","DOI":"10.1093\/europace\/euw177","volume":"19","author":"H Gonna","year":"2017","unstructured":"Gonna H, Domenichini G, Zuberi Z, Norman M, Kaba R, Grimster A, et al. Initial clinical results with the ThermoCool\u00ae SmartTouch\u00ae Surround Flow catheter. Europace. 2017;19:1317\u201321. \nhttps:\/\/doi.org\/10.1093\/europace\/euw177\n\n.","journal-title":"Europace"},{"key":"591_CR30","doi-asserted-by":"publisher","first-page":"1075","DOI":"10.1111\/jce.12759","volume":"26","author":"B Schaeffer","year":"2015","unstructured":"Schaeffer B, Willems S, Sultan A, et al. Loss of pace capture on the ablation line during pulmonary vein isolation versus \u201cdormant conduction\u201d: is adenosine expendable? J Cardiovasc Electrophysiol. 2015;26:1075\u201380. \nhttps:\/\/doi.org\/10.1111\/jce.12759\n\n.","journal-title":"J Cardiovasc Electrophysiol"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-019-00591-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10840-019-00591-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-019-00591-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,17]],"date-time":"2020-07-17T23:10:41Z","timestamp":1595027441000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10840-019-00591-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7,19]]},"references-count":30,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,3]]}},"alternative-id":["591"],"URL":"https:\/\/doi.org\/10.1007\/s10840-019-00591-2","relation":{},"ISSN":["1383-875X","1572-8595"],"issn-type":[{"type":"print","value":"1383-875X"},{"type":"electronic","value":"1572-8595"}],"subject":[],"published":{"date-parts":[[2019,7,19]]},"assertion":[{"value":"21 February 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 July 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 July 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"All patients provided written informed consent and local ethics committee approval was obtained.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Tobias Plenge: none to declare.Jan-Hendrik van den Bruck: none to declare.Jakob L\u00fcker: none to declare.Arian Sultan: none to declare.Daniel Steven received lecturer fees during the conduct of this study from Biosense Webster and research grant support from Biosense Webster outside the submitted work.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}