{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,9]],"date-time":"2025-04-09T12:13:20Z","timestamp":1744200800336,"version":"3.37.3"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,10,17]],"date-time":"2019-10-17T00:00:00Z","timestamp":1571270400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,10,17]],"date-time":"2019-10-17T00:00:00Z","timestamp":1571270400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100007497","name":"Biosense Webster","doi-asserted-by":"publisher","award":["N\/A"],"award-info":[{"award-number":["N\/A"]}],"id":[{"id":"10.13039\/100007497","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"published-print":{"date-parts":[[2020,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n<jats:sec>\n<jats:title>Background or Purpose<\/jats:title>\n<jats:p>The purpose of this analysis was to report on efficacy of a standardized workflow for atrial fibrillation (AF) ablation using technology advances such as 3D imaging and contact force sensing in a real-world setting.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>Consecutive AF ablations from 2014 to 2015 at a high-volume site in Belgium were included. The workflow consisted of a pre-specified procedure sequence including 3D modeling followed by radiofrequency encircling of the pulmonary veins (25\u00a0W posterior wall, 35\u00a0W anterior wall) with a THERMOCOOL SMARTTOUCH\u00ae Catheter guided by CARTO VISITAG\u2122 Module (2.5\u00a0mm\/5\u00a0s stability, 50% &gt;\u20097\u00a0g) and ablation index (targets: 550 anterior wall, 400 posterior wall). Efficiency endpoints were procedure time, fluoroscopy time, and radiation dose. The primary effectiveness endpoint was freedom from atrial arrhythmia recurrence.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>A total of 605 paroxysmal AF (PAF) and 182 persistent AF (PsAF) patients were followed for 436\u2009\u00b1\u2009199\u00a0days. Mean procedure times were short (PAF: 96.1\u2009\u00b1\u200926.2\u00a0min; PsAF: 109.2\u2009\u00b1\u200935.6\u00a0min) with most procedures (90.6% PAF; 81.3% PsAF) completed in \u2264\u2009120\u00a0min. Minimal fluoroscopy was utilized (PAF: 6.1\u2009\u00b1\u20093.8\u00a0min, 5.9\u2009\u00b1\u20093.4\u00a0Gy*cm<jats:sup>2<\/jats:sup>; PsAF: 6.9\u2009\u00b1\u20094.7\u00a0min, 7.4\u2009\u00b1\u20094.9\u00a0Gy*cm<jats:sup>2<\/jats:sup>). Freedom from atrial arrhythmia recurrence was higher for PAF than PsAF patients (OR: 2.0, 95% CI: 1.4\u20132.9, <jats:italic>p<\/jats:italic>\u2009=\u20090.0003), but adjusted mean rates were high in both groups (81.0% vs. 67.9%). Rates were adjusted for prior ablation and age (at 65\u00a0years).<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Conclusion<\/jats:title>\n<jats:p>AF ablation using a standardized workflow resulted in low procedure times and variability, with minimal fluoroscopy exposure. Long-term freedom from atrial arrhythmia recurrence was high in both PAF and PsAF populations.<\/jats:p>\n<\/jats:sec>","DOI":"10.1007\/s10840-019-00622-y","type":"journal-article","created":{"date-parts":[[2019,10,17]],"date-time":"2019-10-17T05:39:40Z","timestamp":1571290780000},"page":"21-27","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["The industrialization of ablation: a highly standardized and reproducible workflow for radiofrequency ablation of atrial fibrillation"],"prefix":"10.1007","volume":"59","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1424-114X","authenticated-orcid":false,"given":"Tom","family":"De Potter","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tina D.","family":"Hunter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lee Ming","family":"Boo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sofia","family":"Chatzikyriakou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Teresa","family":"Strisciuglio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Etel","family":"Silva","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Geelen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,10,17]]},"reference":[{"issue":"9","key":"622_CR1","doi-asserted-by":"publisher","first-page":"1990","DOI":"10.1016\/j.hrthm.2015.06.026","volume":"12","author":"MR Afzal","year":"2015","unstructured":"Afzal MR, Chatta J, Samanta A, Waheed S, Mahmoudi M, Vukas R, et al. Use of contact force sensing technology during radiofrequency ablation reduces recurrence of atrial fibrillation: a systematic review and meta-analysis. Heart Rhythm. 2015;12(9):1990\u20136. \nhttps:\/\/doi.org\/10.1016\/j.hrthm.2015.06.026\n\n.","journal-title":"Heart Rhythm"},{"issue":"5","key":"622_CR2","doi-asserted-by":"publisher","first-page":"775","DOI":"10.1093\/europace\/euw105","volume":"19","author":"M Das","year":"2017","unstructured":"Das M, Loveday JJ, Wynn GJ, Gomes S, Saeed Y, Bonnett LJ, et al. Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values. Europace. 2017;19(5):775\u201383. \nhttps:\/\/doi.org\/10.1093\/europace\/euw105\n\n.","journal-title":"Europace."},{"key":"622_CR3","doi-asserted-by":"publisher","first-page":"f419","DOI":"10.1093\/europace\/eux376","volume":"20","author":"T Phlips","year":"2018","unstructured":"Phlips T, Taghji P, El Haddad M, Wolf M, Knecht S, Vandekerckhove Y, et al. Improving procedural and one-year outcome after contact force-guided pulmonary vein isolation: the role of interlesion distance, ablation index, and contact force variability in the 'CLOSE'-protocol. Europace. 2018;20:f419\u201327. \nhttps:\/\/doi.org\/10.1093\/europace\/eux376\n\n.","journal-title":"Europace."},{"issue":"3","key":"622_CR4","doi-asserted-by":"publisher","first-page":"173","DOI":"10.15420\/aer.2014.3.3.173","volume":"3","author":"T De Potter Jr","year":"2014","unstructured":"De Potter T Jr, Bardhaj G, Viggiano A, Morrice K, Geelen P. Three-dimensional rotational angiography as a Periprocedural imaging tool in atrial fibrillation ablation. Arrhythm Electrophysiol Rev. 2014;3(3):173\u20136. \nhttps:\/\/doi.org\/10.15420\/aer.2014.3.3.173\n\n.","journal-title":"Arrhythm Electrophysiol Rev"},{"issue":"7","key":"622_CR5","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1016\/j.jacc.2014.04.072","volume":"64","author":"A Natale","year":"2014","unstructured":"Natale A, Reddy VY, Monir G, Wilber DJ, Lindsay BD, McElderry HT, et al. Paroxysmal AF catheter ablation with a contact force sensing catheter: Results of the prospective, multicenter SMART-AF trial. J Am Coll Cardiol. 2014;64(7):647\u201356. \nhttps:\/\/doi.org\/10.1016\/j.jacc.2014.04.072\n\n.","journal-title":"J Am Coll Cardiol"},{"issue":"5","key":"622_CR6","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1111\/jce.13179","volume":"28","author":"AA Hussein","year":"2017","unstructured":"Hussein AA, Barakat AF, Saliba WI, Tarakji KG, Bassiouny M, Baranowski B, et al. Persistent atrial fibrillation ablation with or without contact force sensing. J Cardiovasc Electrophysiol. 2017;28(5):483\u20138. \nhttps:\/\/doi.org\/10.1111\/jce.13179\n\n.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"11","key":"622_CR7","doi-asserted-by":"publisher","first-page":"1596","DOI":"10.1253\/circj.CJ-17-0195","volume":"81","author":"N Tanaka","year":"2017","unstructured":"Tanaka N, Inoue K, Tanaka K, Toyoshima Y, Oka T, Okada M, et al. Automated ablation annotation algorithm reduces re-conduction of isolated pulmonary vein and improves outcome after catheter ablation for atrial fibrillation. Circ J. 2017;81(11):1596\u2013602. \nhttps:\/\/doi.org\/10.1253\/circj.CJ-17-0195\n\n.","journal-title":"Circ J"},{"issue":"2","key":"622_CR8","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1007\/s11936-017-0507-9","volume":"19","author":"AM Goldsweig","year":"2017","unstructured":"Goldsweig AM, Abbott JD, Aronow HD. Physician and patient radiation exposure during endovascular procedures. Curr Treat Options Cardiovasc Med. 2017;19(2):10. \nhttps:\/\/doi.org\/10.1007\/s11936-017-0507-9\n\n.","journal-title":"Curr Treat Options Cardiovasc Med"},{"key":"622_CR9","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.cor.2014.04.007","volume":"50","author":"BP Berg","year":"2014","unstructured":"Berg BP, Denton BT, Ayca Erdogan S, Rohleder T, Huschka T. Optimal booking and scheduling in outpatient procedure centers. Comput Oper Res. 2014;50:24\u201337. \nhttps:\/\/doi.org\/10.1016\/j.cor.2014.04.007\n\n.","journal-title":"Comput Oper Res"},{"issue":"12","key":"622_CR10","doi-asserted-by":"publisher","first-page":"1583","DOI":"10.1016\/j.jacep.2018.07.017","volume":"4","author":"A Baher","year":"2018","unstructured":"Baher A, Kheirkhahan M, Rechenmacher SJ, Marashly Q, Kholmovski EG, Siebermair J, et al. High-power radiofrequency catheter ablation of atrial fibrillation: Using Late Gadolinium Enhancement Magnetic Resonance Imaging as a Novel Index of Esophageal Injury. JACC Clin Electrophysiol. 2018;4(12):1583\u201394. \nhttps:\/\/doi.org\/10.1016\/j.jacep.2018.07.017\n\n.","journal-title":"JACC Clin Electrophysiol"},{"issue":"9","key":"622_CR11","doi-asserted-by":"publisher","first-page":"1287","DOI":"10.1111\/jce.13651","volume":"29","author":"M Barkagan","year":"2018","unstructured":"Barkagan M, Contreras-Valdes FM, Leshem E, Buxton AE, Nakagawa H, Anter E. High-power and short-duration ablation for pulmonary vein isolation: safety, efficacy, and long-term durability. J Cardiovasc Electrophysiol. 2018;29(9):1287\u201396. \nhttps:\/\/doi.org\/10.1111\/jce.13651\n\n.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"11","key":"622_CR12","doi-asserted-by":"publisher","first-page":"1570","DOI":"10.1111\/jce.13724","volume":"29","author":"F Bourier","year":"2018","unstructured":"Bourier F, Duchateau J, Vlachos K, Lam A, Martin CA, Takigawa M, et al. High-power short-duration versus standard radiofrequency ablation: insights on lesion metrics. J Cardiovasc Electrophysiol. 2018;29(11):1570\u20135. \nhttps:\/\/doi.org\/10.1111\/jce.13724\n\n.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"4","key":"622_CR13","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1016\/j.jacep.2017.11.018","volume":"4","author":"E Leshem","year":"2018","unstructured":"Leshem E, Zilberman I, Tschabrunn CM, Barkagan M, Contreras-Valdes FM, Govari A, et al. High-power and short-duration ablation for pulmonary vein isolation: Biophysical Characterization. JACC Clin Electrophysiol. 2018;4(4):467\u201379. \nhttps:\/\/doi.org\/10.1016\/j.jacep.2017.11.018\n\n.","journal-title":"JACC Clin Electrophysiol"},{"issue":"5","key":"622_CR14","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1111\/j.1540-8159.2010.02990.x","volume":"34","author":"RA Winkle","year":"2011","unstructured":"Winkle RA, Mead RH, Engel G, Patrawala RA. Atrial fibrillation ablation: \"perpetual motion\" of open irrigated tip catheters at 50 W is safe and improves outcomes. Pacing Clin Electrophysiol. 2011;34(5):531\u20139. \nhttps:\/\/doi.org\/10.1111\/j.1540-8159.2010.02990.x\n\n.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"1","key":"622_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10840-018-0322-6","volume":"52","author":"RA Winkle","year":"2018","unstructured":"Winkle RA, Moskovitz R, Hardwin Mead R, Engel G, Kong MH, Fleming W, et al. Atrial fibrillation ablation using very short duration 50 W ablations and contact force sensing catheters. J Interv Card Electrophysiol. 2018;52(1):1\u20138. \nhttps:\/\/doi.org\/10.1007\/s10840-018-0322-6\n\n.","journal-title":"J Interv Card Electrophysiol"},{"issue":"2","key":"622_CR16","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1007\/s00392-013-0625-7","volume":"103","author":"R Wakili","year":"2014","unstructured":"Wakili R, Clauss S, Schmidt V, Ulbrich M, Hahnefeld A, Schussler F, et al. Impact of real-time contact force and impedance measurement in pulmonary vein isolation procedures for treatment of atrial fibrillation. Clin Res Cardiol. 2014;103(2):97\u2013106. \nhttps:\/\/doi.org\/10.1007\/s00392-013-0625-7\n\n.","journal-title":"Clin Res Cardiol"},{"issue":"4","key":"622_CR17","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1093\/europace\/euu350","volume":"17","author":"G Ciconte","year":"2015","unstructured":"Ciconte G, Baltogiannis G, de Asmundis C, Sieira J, Conte G, Di Giovanni G, et al. Circumferential pulmonary vein isolation as index procedure for persistent atrial fibrillation: a comparison between radiofrequency catheter ablation and second-generation cryoballoon ablation. Europace. 2015;17(4):559\u201365. \nhttps:\/\/doi.org\/10.1093\/europace\/euu350\n\n.","journal-title":"Europace."},{"issue":"1","key":"622_CR18","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.jacep.2017.06.023","volume":"4","author":"P Taghji","year":"2018","unstructured":"Taghji P, El Haddad M, Phlips T, Wolf M, Knecht S, Vandekerckhove Y, et al. Evaluation of a strategy aiming to enclose the pulmonary veins with contiguous and optimized radiofrequency lesions in paroxysmal atrial fibrillation: A pilot study. JACC Clin Electrophysiol. 2018;4(1):99\u2013108. \nhttps:\/\/doi.org\/10.1016\/j.jacep.2017.06.023\n\n.","journal-title":"JACC Clin Electrophysiol"},{"issue":"4","key":"622_CR19","doi-asserted-by":"publisher","first-page":"974","DOI":"10.1253\/circj.CJ-17-0421","volume":"82","author":"G Zucchelli","year":"2018","unstructured":"Zucchelli G, Sirico G, Rebellato L, Marini M, Stabile G, Del Greco M, et al. Contiguity between ablation lesions and strict catheter stability settings assessed by VISITAG(TM) module improve clinical outcomes of paroxysmal atrial fibrillation ablation - results from the VISITALY study. Circ J. 2018;82(4):974\u201382. \nhttps:\/\/doi.org\/10.1253\/circj.CJ-17-0421\n\n.","journal-title":"Circ J"},{"issue":"6","key":"622_CR20","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1016\/j.jacep.2016.07.014","volume":"2","author":"VY Reddy","year":"2016","unstructured":"Reddy VY, Pollak S, Lindsay BD, McElderry HT, Natale A, Kantipudi C, et al. Relationship between catheter stability and 12-month success after pulmonary vein isolation: A subanalysis of the SMART-AF trial. JACC Clin Electrophysiol. 2016;2(6):691\u20139. \nhttps:\/\/doi.org\/10.1016\/j.jacep.2016.07.014\n\n.","journal-title":"JACC Clin Electrophysiol"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-019-00622-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10840-019-00622-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-019-00622-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,10,15]],"date-time":"2020-10-15T23:20:03Z","timestamp":1602804003000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10840-019-00622-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10,17]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,10]]}},"alternative-id":["622"],"URL":"https:\/\/doi.org\/10.1007\/s10840-019-00622-y","relation":{},"ISSN":["1383-875X","1572-8595"],"issn-type":[{"type":"print","value":"1383-875X"},{"type":"electronic","value":"1572-8595"}],"subject":[],"published":{"date-parts":[[2019,10,17]]},"assertion":[{"value":"14 March 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 September 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 October 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"T De Potter, S Chatzikyriakou, E Silva Garcia, and P Geelen have no disclosures. T Strisciuglio has been supported by a research grant provided by the CardioPath PhD program. TD Hunter is an employee of CTI Clinical Trial and Consulting Services, which is a consultant to Biosense Webster, Inc. L Boo is an employee of Biosense Webster, Inc.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}