{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T09:32:24Z","timestamp":1762507944777},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,12,8]],"date-time":"2019-12-08T00:00:00Z","timestamp":1575763200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,12,8]],"date-time":"2019-12-08T00:00:00Z","timestamp":1575763200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"published-print":{"date-parts":[[2020,1]]},"DOI":"10.1007\/s10840-019-00660-6","type":"journal-article","created":{"date-parts":[[2019,12,8]],"date-time":"2019-12-08T10:02:28Z","timestamp":1575799348000},"page":"107-114","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Comparison between His-bundle pacing guided by Ensite NavX system and conventional fluoroscopy"],"prefix":"10.1007","volume":"57","author":[{"given":"Yiran","family":"Hu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ligang","family":"Ding","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Hua","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Min","family":"Gu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Minsi","family":"Cai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xuhua","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaohan","family":"Fan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"HongXia","family":"Niu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shu","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,12,8]]},"reference":[{"issue":"3","key":"660_CR1","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1016\/j.hrthm.2017.10.039","volume":"15","author":"P Vijayaraman","year":"2018","unstructured":"Vijayaraman P, Dandamudi G, Zanon F, et al. Permanent His bundle pacing: recommendations from a multicenter His Bundle Pacing Collaborative Working Group for standardization of definitions, implant measurements, and follow-up. Heart Rhythm. 2018;15(3):460\u20138.","journal-title":"Heart Rhythm"},{"issue":"20","key":"660_CR2","doi-asserted-by":"publisher","first-page":"2319","DOI":"10.1016\/j.jacc.2018.02.048","volume":"71","author":"M Abdelrahman","year":"2018","unstructured":"Abdelrahman M, Subzposh FA, Beer D, et al. Clinical outcomes of His bundle pacing compared to right ventricular pacing. J Am Coll Cardiol. 2018;71(20):2319\u201330.","journal-title":"J Am Coll Cardiol"},{"issue":"6","key":"660_CR3","doi-asserted-by":"publisher","first-page":"1362","DOI":"10.1016\/j.hrthm.2016.03.040","volume":"13","author":"G Dandamudi","year":"2016","unstructured":"Dandamudi G, Vijayaraman P. How to perform permanent His bundle pacing in routine clinical practice. Heart Rhythm. 2016;13(6):1362\u20136.","journal-title":"Heart Rhythm"},{"issue":"2","key":"660_CR4","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1148\/radiol.10091269","volume":"257","author":"DL Miller","year":"2010","unstructured":"Miller DL, Balter S, Schueler BA, Wagner LK, Strauss KJ, Vano E. Clinical radiation management for fluoroscopically guided interventional procedures. Radiology. 2010;257(2):321\u201332.","journal-title":"Radiology"},{"issue":"2","key":"660_CR5","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1007\/s10840-015-0088-z","volume":"45","author":"JM Sanchez","year":"2016","unstructured":"Sanchez JM, Yanics MA, Wilson P, Doshi A, Kurian T, Pieper S. Fluoroless catheter ablation in adults: a single center experience. J Interv Card Electrophysiol. 2016;45(2):199\u2013207.","journal-title":"J Interv Card Electrophysiol"},{"issue":"10","key":"660_CR6","doi-asserted-by":"publisher","first-page":"1087","DOI":"10.1111\/j.1540-8167.2012.02373.x","volume":"23","author":"R Lemery","year":"2012","unstructured":"Lemery R. Interventional electrophysiology at the crossroads: cardiac mapping, ablation and pacing without fluoroscopy. J Cardiovasc Electrophysiol. 2012;23(10):1087\u201391.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"2","key":"660_CR7","doi-asserted-by":"publisher","first-page":"e006801","DOI":"10.1161\/CIRCEP.118.006801","volume":"12","author":"MV Orlov","year":"2019","unstructured":"Orlov MV, Koulouridis I, Monin AJ, et al. Direct visualization of the His bundle pacing lead placement by 3-dimensional electroanatomic mapping. Circ Arrhythm Electrophysiol. 2019;12(2):e006801.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"2","key":"660_CR8","doi-asserted-by":"publisher","first-page":"e006967","DOI":"10.1161\/CIRCEP.118.006967","volume":"12","author":"PS Sharma","year":"2019","unstructured":"Sharma PS, Huang HD, Trohman RG, Naperkowski A, Ellenbogen KA, Vijayaraman P. Low fluoroscopy permanent His bundle pacing using electroanatomic mapping. Circ Arrhythm Electrophysiol. 2019;12(2):e006967.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"21","key":"660_CR9","first-page":"e350","volume":"117","author":"AE Epstein","year":"2008","unstructured":"Epstein AE, JP DM, Ellenbogen KA, et al. ACC\/AHA\/HRS 2008 Guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology\/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC\/AHA\/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons. Circulation. 2008;117(21):e350\u2013408.","journal-title":"Circulation"},{"issue":"8","key":"660_CR10","doi-asserted-by":"publisher","first-page":"1162","DOI":"10.1111\/j.1540-8167.1999.tb00291.x","volume":"10","author":"FG Cosio","year":"1999","unstructured":"Cosio FG, Anderson RH, Kuck KH, et al. ESCWGA\/NASPE\/P experts consensus statement: living anatomy of the atrioventricular junctions. A guide to electrophysiologic mapping. Working Group of Arrhythmias of the European Society of Cardiology. North American Society of Pacing and Electrophysiology. J Cardiovasc Electrophysiol. 1999;10(8):1162\u201370.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"7","key":"660_CR11","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1111\/jce.12437","volume":"25","author":"VR Vaidya","year":"2014","unstructured":"Vaidya VR, Desimone CV, Madhavan M, et al. Compatibility of electroanatomical mapping systems with a concurrent percutaneous axial flow ventricular assist device. J Cardiovasc Electrophysiol. 2014;25(7):781\u20136.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"9","key":"660_CR12","doi-asserted-by":"publisher","first-page":"1017","DOI":"10.1111\/j.1540-8167.2005.50155.x","volume":"16","author":"WG Stevenson","year":"2005","unstructured":"Stevenson WG, Soejima K. Recording techniques for clinical electrophysiology. J Cardiovasc Electrophysiol. 2005;16(9):1017\u201322.","journal-title":"J Cardiovasc Electrophysiol"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-019-00660-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10840-019-00660-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-019-00660-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,12,7]],"date-time":"2020-12-07T00:03:48Z","timestamp":1607299428000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10840-019-00660-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,8]]},"references-count":12,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,1]]}},"alternative-id":["660"],"URL":"https:\/\/doi.org\/10.1007\/s10840-019-00660-6","relation":{},"ISSN":["1383-875X","1572-8595"],"issn-type":[{"value":"1383-875X","type":"print"},{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12,8]]},"assertion":[{"value":"7 August 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 October 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 December 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study was performed with written informed consent from all patients and approval from the Ethics Committee of Fuwai Hospital and in accordance with the Declaration of Helsinki.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}