{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T13:17:21Z","timestamp":1792761441878,"version":"4.5.0"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2019,12,18]],"date-time":"2019-12-18T00:00:00Z","timestamp":1576627200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,12,18]],"date-time":"2019-12-18T00:00:00Z","timestamp":1576627200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"published-print":{"date-parts":[[2020,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Purpose<\/jats:title>\n<jats:p>We have reported the calcification of Endotak defibrillation leads that required replacement. The aim of this study was to assess calcified Endotak Reliance leads in the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) database and compare them to calcified Sprint Fidelis, Sprint Quattro Secure, Riata, and Durata leads in MAUDE.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>We searched the MAUDE database from 2008 to 2019 for defibrillation lead calcification using the terms \u201ccalcium,\u201d \u201ccalcification,\u201d and \u201ccalcified\u201d. Included were explanted leads whose manufacturers found calcium on the shocking and\/or pacing electrode.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>The MAUDE search identified 113 calcified defibrillation leads that qualified for the study, including 109 Endotak Reliance leads, 1 Sprint Quattro Secure lead, 2 Durata leads, 1 Riata ST lead, and no Sprint Fidelis lead. The sign of calcification was a gradual increase in shocking or pacing impedance. Average implant time was 7.4\u2009\u00b1\u20093.1 (range: 1.3\u201316.5) years. Only Endotak Reliance leads had shocking coil calcification (<jats:italic>n<\/jats:italic>\u2009=\u200972; 66.0%) and five (6.9%) of these failed defibrillation threshold (DFT) testing. Distal pacing electrode calcification affected 55 (50.4%) Endotak Reliance leads. The four other leads had pacing ring electrode calcification only.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusion<\/jats:title>\n<jats:p>Endotak Reliance defibrillation leads appear prone to shocking coil and\/or distal pacing electrode calcification. High impedances may compromise defibrillation and pacing therapy. Patients who have these leads should be monitored; those exhibiting high shocking impedances should be considered for DFT testing. Lead replacement should be considered for pacemaker-dependent patients whose leads exhibit progressively high impedances.<\/jats:p>\n<\/jats:sec>","DOI":"10.1007\/s10840-019-00685-x","type":"journal-article","created":{"date-parts":[[2019,12,18]],"date-time":"2019-12-18T09:03:40Z","timestamp":1576659820000},"page":"253-259","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["High shocking and pacing impedances due to defibrillation lead calcification"],"prefix":"10.1007","volume":"58","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9172-1089","authenticated-orcid":false,"given":"Robert G.","family":"Hauser","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jay","family":"Sengupta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Susan","family":"Casey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chuen","family":"Tang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Larissa I.","family":"Stanberry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raed","family":"Abdelhadi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,12,18]]},"reference":[{"key":"685_CR1","doi-asserted-by":"publisher","first-page":"1358","DOI":"10.1016\/j.jacc.2015.12.067","volume":"67","author":"CD Swerdlow","year":"2016","unstructured":"Swerdlow CD, Kalahasty G, Ellenbogen KA. Implantable cardiac defibrillator lead failure and management. J Am Coll Cardiol. 2016;67:1358\u201368.","journal-title":"J Am Coll Cardiol"},{"issue":"Suppl 1","key":"685_CR2","first-page":"S44","volume":"55","author":"RG Hauser","year":"2019","unstructured":"Hauser RG. Calcification of Endotak ICD leads: clinical significance and need for surveillance. J Interv Card Electrophysiol. 2019;55(Suppl 1):S44.","journal-title":"J Interv Card Electrophysiol"},{"key":"685_CR3","doi-asserted-by":"publisher","first-page":"1215","DOI":"10.1016\/j.hrthm.2019.02.019","volume":"16","author":"RG Hauser","year":"2019","unstructured":"Hauser RG, Sengupta J, Schloss EJ, Stanberry LI, Wananu MK, Abdelhadi R. Internal insulation breaches in an implantable cardioverter-defibrillator lead with redundant conductors. Heart Rhythm. 2019;16:1215\u201322.","journal-title":"Heart Rhythm"},{"key":"685_CR4","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1093\/europace\/euu391","volume":"17","author":"S Nisam","year":"2015","unstructured":"Nisam S, Reddy S. The story of\u2026a lead. Europace. 2015;17:677\u201388.","journal-title":"Europace"},{"key":"685_CR5","doi-asserted-by":"publisher","first-page":"994","DOI":"10.1093\/europace\/eur384","volume":"14","author":"A Kolodzinska","year":"2012","unstructured":"Kolodzinska A, Kutarski A, Koperski L, Grabowski M, Malecka B, Opolski G. Differences in encapsulating lead tissue in patients who underwent transvenous lead removal. Europace. 2012;14:994\u20131001.","journal-title":"Europace"},{"key":"685_CR6","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1111\/j.1540-8167.2005.00261.x","volume":"17","author":"A Schuchert","year":"2006","unstructured":"Schuchert A, Winter J, Binner L, K\u00fchl M, Meinertz T, Reliance Investigators. Intraoperative comparison of a subthreshold test pulse with the standard high-energy shock approach for the measurement of defibrillation impedance. J Cardiovasc Electrophysiol. 2006;17:56\u20139.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"685_CR7","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1016\/j.hrthm.2013.02.027","volume":"10","author":"JN Koneru","year":"2013","unstructured":"Koneru JN, Gunderson BD, Sachanandani H, Wohl BN, Kendall KT, Swerdlow CD, et al. Diagnosis of high-voltage fractures in Sprint fidelis leads. Heart Rhythm. 2013;10:813\u20138.","journal-title":"Heart Rhythm"},{"key":"685_CR8","doi-asserted-by":"publisher","unstructured":"Swerdlow CD, Porterfield JE, Kottam AG, Kroll MW. Why low-voltage shock impedance measurements fail to reliably detect insulation breaches in transvenous defibrillation leads. Heart Rhythm. https:\/\/doi.org\/10.1016\/j.hrthm.2019.05.021.","DOI":"10.1016\/j.hrthm.2019.05.021"},{"key":"685_CR9","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1016\/j.jtcvs.2008.02.053","volume":"137","author":"RS Farivar","year":"2009","unstructured":"Farivar RS, Sherman SK, Cohn LH. Late rupture of polytetrafluoroethylene neochordae after mitral valve repair. J Thor Cardiovasc Surg. 2009;137:504\u20136.","journal-title":"J Thor Cardiovasc Surg"},{"key":"685_CR10","doi-asserted-by":"publisher","first-page":"955","DOI":"10.1016\/j.athoracsur.2009.07.084","volume":"89","author":"S Fukunaga","year":"2010","unstructured":"Fukunaga S, Tomoeda H, Ueda T, Ryusuke M, Aoyagi S, Kato S. Recurrent mitral regurgitation due to calcified synthetic chordae. Ann Thor Surg. 2010;89:955\u20137.","journal-title":"Ann Thor Surg"},{"key":"685_CR11","doi-asserted-by":"publisher","first-page":"1238","DOI":"10.1016\/j.hrthm.2007.07.017","volume":"4","author":"CJ Love","year":"2007","unstructured":"Love CJ. Lead extraction. Heart Rhythm. 2007;4:1238\u201343.","journal-title":"Heart Rhythm"},{"key":"685_CR12","doi-asserted-by":"publisher","first-page":"1352","DOI":"10.1016\/j.hrthm.2008.02.037","volume":"5","author":"CA Henrikson","year":"2008","unstructured":"Henrikson CA, Brinker JA. How to prevent, recognize, and manage complications of lead extraction. Part III: Procedural factors. Heart Rhythm. 2008;5:1352\u20134.","journal-title":"Heart Rhythm"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-019-00685-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10840-019-00685-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-019-00685-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,12,17]],"date-time":"2020-12-17T01:22:26Z","timestamp":1608168146000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10840-019-00685-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,18]]},"references-count":12,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020,9]]}},"alternative-id":["685"],"URL":"https:\/\/doi.org\/10.1007\/s10840-019-00685-x","relation":{},"ISSN":["1383-875X","1572-8595"],"issn-type":[{"value":"1383-875X","type":"print"},{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12,18]]},"assertion":[{"value":"22 November 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 December 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 December 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}