{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,25]],"date-time":"2025-11-25T20:38:20Z","timestamp":1764103100873,"version":"3.37.3"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,5,31]],"date-time":"2020-05-31T00:00:00Z","timestamp":1590883200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,5,31]],"date-time":"2020-05-31T00:00:00Z","timestamp":1590883200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"published-print":{"date-parts":[[2021,6]]},"DOI":"10.1007\/s10840-020-00770-6","type":"journal-article","created":{"date-parts":[[2020,5,31]],"date-time":"2020-05-31T00:02:26Z","timestamp":1590883346000},"page":"95-104","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Temperature-guided ablation with the second-generation cryoballoon for paroxysmal atrial fibrillation: 3-year follow-up in a multicenter experience"],"prefix":"10.1007","volume":"61","author":[{"given":"Gaetano","family":"Paparella","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Saverio","family":"Iacopino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thiago Guimar\u00e3es","family":"Os\u00f3rio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juan Pablo Abugattas","family":"de Torres","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erwin","family":"Str\u00f6ker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juan","family":"Sieira","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hannes","family":"Vanacker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernard","family":"De Ruyter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Serge","family":"Boveda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Riccardo","family":"Maj","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gianluca","family":"Borio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alessandro","family":"Rizzo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alessio","family":"Galli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pedro","family":"Brugada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlo","family":"de Asmundis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2967-1345","authenticated-orcid":false,"given":"Gian-Battista","family":"Chierchia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,5,31]]},"reference":[{"issue":"5","key":"770_CR1","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1093\/europace\/eut417","volume":"16","author":"GB Chierchia","year":"2014","unstructured":"Chierchia GB, Di Giovanni G, Ciconte G, De Asmundis C, Conte G, Sieira-Moret J, et al. Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up. Europace. 2014;16(5):639\u201344. https:\/\/doi.org\/10.1093\/europace\/eut417.","journal-title":"Europace"},{"issue":"2","key":"770_CR2","doi-asserted-by":"publisher","first-page":"288","DOI":"10.1161\/CIRCEP.114.001473","volume":"7","author":"A Metzner","year":"2014","unstructured":"Metzner A, Reissmann B, Rausch P, Mathew S, Wohlmuth P, Tilz R, et al. One-year clinical outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon. Circ Arrhythm Electrophysiol. 2014;7(2):288\u201392. https:\/\/doi.org\/10.1161\/CIRCEP.114.001473.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"8","key":"770_CR3","doi-asserted-by":"publisher","first-page":"834","DOI":"10.1111\/jce.12409","volume":"25","author":"G Di Giovanni","year":"2014","unstructured":"Di Giovanni G, Wauters K, Chierchia GB, Sieira J, Levinstein M, Conte G, et al. One-year follow-up after single procedure cryoballoon ablation: a comparison between the first and second generation balloon. J Cardiovasc Electrophysiol. 2014;25(8):834\u20139. https:\/\/doi.org\/10.1111\/jce.12409.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"8","key":"770_CR4","doi-asserted-by":"publisher","first-page":"840","DOI":"10.1111\/jce.12417","volume":"25","author":"A F\u00fcrnkranz","year":"2014","unstructured":"F\u00fcrnkranz A, Bordignon S, Dugo D, Perotta L, Gunawardene M, Schulte-Hahn B, et al. Improved 1-year clinical success rate of pulmonary vein isolation with the second-generation cryoballoon in patients with paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol. 2014;25(8):840\u20134. https:\/\/doi.org\/10.1111\/jce.12417.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"6","key":"770_CR5","doi-asserted-by":"publisher","first-page":"1359","DOI":"10.1161\/CIRCEP.115.002966","volume":"8","author":"G Ciconte","year":"2015","unstructured":"Ciconte G, Mugnai G, Sieira J, Velagic V, Saitoh Y, Irfan G, et al. On the quest for the best freeze: predictors of late pulmonary vein reconnections after second-generation cryoballoon ablation. Circ Arrhythm Electrophysiol. 2015;8(6):1359\u201365. https:\/\/doi.org\/10.1161\/CIRCEP.115.002966.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"7","key":"770_CR6","doi-asserted-by":"publisher","first-page":"796","DOI":"10.1111\/jce.12986","volume":"27","author":"G Ciconte","year":"2016","unstructured":"Ciconte G, Sieira-Moret J, Hacioglu E, Mugnai G, Di Giovanni G, Velagic V, et al. Single 3-minute versus double 4-minute freeze strategy for second-generation cryoballoon ablation: a single-center experience. J Cardiovasc Electrophysiol. 2016;27(7):796\u2013803. https:\/\/doi.org\/10.1111\/jce.12986.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"3","key":"770_CR7","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1016\/j.hrthm.2016.11.023","volume":"14","author":"S Iacopino","year":"2017","unstructured":"Iacopino S, Mugnai G, Takarada K, Paparella G, Str\u00f6ker E, De Regibus V, et al. Second-generation cryoballoon ablation without the use of real-time recordings: a novel strategy based on a temperature-guided approach to ablation. Heart Rhythm. 2017;14(3):322\u20138. https:\/\/doi.org\/10.1016\/j.hrthm.2016.11.023.","journal-title":"Heart Rhythm"},{"key":"770_CR8","doi-asserted-by":"publisher","unstructured":"Priori SG, Blomstr\u00f6m-Lundqvist C, Mazzanti A, Blom N, Borggrefe M, Camm J, et al. 2015 ESC guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death. Russ J Cardiol. 2016. https:\/\/doi.org\/10.15829\/1560-4071-2016-7-5-86.","DOI":"10.15829\/1560-4071-2016-7-5-86"},{"issue":"5","key":"770_CR9","doi-asserted-by":"publisher","first-page":"646","DOI":"10.1016\/j.hrthm.2013.01.011","volume":"10","author":"J Ghosh","year":"2013","unstructured":"Ghosh J, Sepahpour A, Chan KH, Singarayar S, McGuire MA. Immediate balloon deflation for prevention of persistent phrenic nerve palsy during pulmonary vein isolation by balloon cryoablation. Heart Rhythm. 2013;10(5):646\u201352. https:\/\/doi.org\/10.1016\/j.hrthm.2013.01.011.","journal-title":"Heart Rhythm"},{"issue":"4","key":"770_CR10","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1016\/j.jacc.2008.04.021","volume":"52","author":"T Neumann","year":"2008","unstructured":"Neumann T, Vogt J, Schumacher B, Dorszewski A, Kuniss M, Neuser H, et al. Circumferential pulmonary vein isolation with the cryoballoon technique. J Am Coll Cardiol. 2008;52(4):273\u20138. https:\/\/doi.org\/10.1016\/j.jacc.2008.04.021.","journal-title":"J Am Coll Cardiol"},{"issue":"6","key":"770_CR11","doi-asserted-by":"publisher","first-page":"699","DOI":"10.1093\/eurheartj\/ehn570","volume":"30","author":"KRJ Chun","year":"2009","unstructured":"Chun KRJ, Schmidt B, Metzner A, Tilz R, Zerm T, K\u00f6ster I, et al. The \u201csingle big cryoballoon\u201d technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study. Eur Heart J. 2009;30(6):699\u2013709. https:\/\/doi.org\/10.1093\/eurheartj\/ehn570.","journal-title":"Eur Heart J"},{"key":"770_CR12","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1007\/s10840-011-9585-x","volume-title":"Journal of Interventional Cardiac Electrophysiology","author":"U Dorwarth","year":"2011","unstructured":"Dorwarth U, Schmidt M, Wankerl M, Krieg J, Straube F, Hoffmann E. Pulmonary vein electrophysiology during cryoballoon ablation as a predictor for procedural success. In: Journal of Interventional Cardiac Electrophysiology, vol. 32; 2011. p. 205\u201311. https:\/\/doi.org\/10.1007\/s10840-011-9585-x."},{"issue":"2","key":"770_CR13","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1093\/europace\/euq388","volume":"13","author":"A Sorgente","year":"2011","unstructured":"Sorgente A, Chierchia GB, De Asmundis C, Sarkozy A, Namdar M, Capulzini L, et al. Pulmonary vein ostium shape and orientation as possible predictors of occlusion in patients with drug-refractory paroxysmal atrial fibrillation undergoing cryoballoon ablation. Europace. 2011;13(2):205\u201312. https:\/\/doi.org\/10.1093\/europace\/euq388.","journal-title":"Europace"},{"issue":"9","key":"770_CR14","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1080\/17434440.2019.1653181","volume":"16","author":"TG Os\u00f3rio","year":"2019","unstructured":"Os\u00f3rio TG, Couti\u00f1o HE, Brugada P, Chierchia GB, De Asmundis C. Recent advances in cryoballoon ablation for atrial fibrillation. Expert Rev Med Devices. 2019;16(9):799\u2013808. https:\/\/doi.org\/10.1080\/17434440.2019.1653181.","journal-title":"Expert Rev Med Devices"},{"issue":"3","key":"770_CR15","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1016\/j.jacep.2018.11.006","volume":"5","author":"BP Knight","year":"2019","unstructured":"Knight BP, Novak PG, Sangrigoli R, Champagne J, Dubuc M, Adler SW, et al. Long-term outcomes after ablation for paroxysmal atrial fibrillation using the second-generation cryoballoon. JACC Clin Electrophysiol. 2019;5(3):306\u201314. https:\/\/doi.org\/10.1016\/j.jacep.2018.11.006.","journal-title":"JACC Clin Electrophysiol"},{"key":"770_CR16","doi-asserted-by":"publisher","unstructured":"Choudhury R, Coutino HE, Darciuc R, Str\u00f6ker E, De Regibus V, Mugnai G, et al. Continuous monitoring after second-generation cryoballoon ablation for paroxysmal atrial fibrillation in patients with cardiac implantable electronic devices. Heart Rhythm. 2019. https:\/\/doi.org\/10.1016\/j.hrthm.2018.08.015.","DOI":"10.1016\/j.hrthm.2018.08.015"},{"issue":"6","key":"770_CR17","doi-asserted-by":"publisher","first-page":"821","DOI":"10.1016\/j.hrthm.2011.01.044","volume":"8","author":"A F\u00fcrnkranz","year":"2011","unstructured":"F\u00fcrnkranz A, K\u00f6ster I, Chun KRJ, Metzner A, Mathew S, Konstantinidou M, et al. Cryoballoon temperature predicts acute pulmonary vein isolation. Heart Rhythm. 2011;8(6):821\u20135. https:\/\/doi.org\/10.1016\/j.hrthm.2011.01.044.","journal-title":"Heart Rhythm"},{"issue":"9","key":"770_CR18","doi-asserted-by":"publisher","first-page":"1311","DOI":"10.1016\/j.hrthm.2013.06.014","volume":"10","author":"J Ghosh","year":"2013","unstructured":"Ghosh J, Martin A, Keech AC, Chan KH, Gomes S, Singarayar S, et al. Balloon warming time is the strongest predictor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillation. Heart Rhythm. 2013;10(9):1311\u20137. https:\/\/doi.org\/10.1016\/j.hrthm.2013.06.014.","journal-title":"Heart Rhythm"},{"issue":"8","key":"770_CR19","doi-asserted-by":"publisher","first-page":"845","DOI":"10.1111\/jce.12421","volume":"25","author":"G Ciconte","year":"2014","unstructured":"Ciconte G, Chierchia GB, De Asmundis C, Sieira J, Conte G, Juli\u00e1 J, et al. Spontaneous and adenosine-induced pulmonary vein reconnection after cryoballoon ablation with the second-generation device. J Cardiovasc Electrophysiol. 2014;25(8):845\u201351. https:\/\/doi.org\/10.1111\/jce.12421.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"5","key":"770_CR20","doi-asserted-by":"publisher","first-page":"1088","DOI":"10.1161\/CIRCEP.115.003007","volume":"8","author":"CH Heeger","year":"2015","unstructured":"Heeger CH, Wissner E, Mathew S, Deiss S, Lemes C, Rillig A, et al. Once isolated, always isolated? Incidence and characteristics of pulmonary vein reconduction after second-generation cryoballoon-based pulmonary vein isolation. Circ Arrhythm Electrophysiol. 2015;8(5):1088\u201394. https:\/\/doi.org\/10.1161\/CIRCEP.115.003007.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"5","key":"770_CR21","doi-asserted-by":"publisher","first-page":"e006204","DOI":"10.1161\/CIRCEP.118.006204","volume":"11","author":"KH Kuck","year":"2018","unstructured":"Kuck KH, Brugada J, F\u00fcrnkranz A, Chun KRJ, Metzner A, Ouyang F, et al. Impact of female sex on clinical outcomes in the FIRE and ICE trial of catheter ablation for atrial fibrillation. Circ Arrhythmia Electrophysiol. 2018;11(5):e006204. https:\/\/doi.org\/10.1161\/CIRCEP.118.006204.","journal-title":"Circ Arrhythmia Electrophysiol"},{"issue":"1","key":"770_CR22","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1007\/s10840-019-00601-3","volume":"56","author":"D Ricciardi","year":"2019","unstructured":"Ricciardi D, Arena G, Verlato R, Iacopino S, Pieragnoli P, Molon G, et al. Sex effect on efficacy of pulmonary vein cryoablation in patients with atrial fibrillation: data from the multicenter real-world 1STOP project. J Interv Card Electrophysiol. 2019;56(1):9\u201318. https:\/\/doi.org\/10.1007\/s10840-019-00601-3.","journal-title":"J Interv Card Electrophysiol"},{"issue":"4","key":"770_CR23","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1016\/j.hrthm.2016.12.014","volume":"14","author":"KRJ Chun","year":"2017","unstructured":"Chun KRJ, Stich M, F\u00fcrnkranz A, Bordignon S, Perrotta L, Dugo D, et al. Individualized cryoballoon energy pulmonary vein isolation guided by real-time pulmonary vein recordings, the randomized ICE-T trial. Heart Rhythm. 2017;14(4):495\u2013500. https:\/\/doi.org\/10.1016\/j.hrthm.2016.12.014.","journal-title":"Heart Rhythm"},{"key":"770_CR24","doi-asserted-by":"publisher","unstructured":"Santangeli P, Di Biase L, Pelargonio G, Natale A. Outcome of invasive electrophysiological procedures and gender: are males and females the same? J Cardiovasc Electrophysiol. 2011. https:\/\/doi.org\/10.1111\/j.1540-8167.2010.01920.x.","DOI":"10.1111\/j.1540-8167.2010.01920.x"},{"issue":"3","key":"770_CR25","doi-asserted-by":"publisher","first-page":"434","DOI":"10.1093\/europace\/euy154","volume":"21","author":"E Str\u00f6ker","year":"2019","unstructured":"Str\u00f6ker E, De Asmundis C, Kupics K, Takarada K, Mugnai G, De Cocker J, et al. Value of ultrasound for access guidance and detection of subclinical vascular complications in the setting of atrial fibrillation cryoballoon ablation. Europace. 2019;21(3):434\u20139. https:\/\/doi.org\/10.1093\/europace\/euy154.","journal-title":"Europace"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-020-00770-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-020-00770-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-020-00770-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,11]],"date-time":"2021-06-11T05:50:23Z","timestamp":1623390623000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-020-00770-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,31]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,6]]}},"alternative-id":["770"],"URL":"https:\/\/doi.org\/10.1007\/s10840-020-00770-6","relation":{},"ISSN":["1383-875X","1572-8595"],"issn-type":[{"type":"print","value":"1383-875X"},{"type":"electronic","value":"1572-8595"}],"subject":[],"published":{"date-parts":[[2020,5,31]]},"assertion":[{"value":"12 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 May 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 May 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The protocol was carried out in accordance with the ethical principles for medical research involving human subjects established by Helsinki\u2019s declaration, protecting the privacy of all the participants as well as the confidentiality of their personal information. The study was approved by the local ethics committee.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"GBC and CdA receive compensation for teaching purposes and proctoring from AF solutions and Medtronic. PB receives research grants on behalf of the center from Biotronik, Medtronic, St Jude Medical, Sorin, and Boston Scientific, and speaker\u2019s fees from Biosense Webster, Biotronik, and Medtronic. CdA is a consultant for Daiichi Sankyo. GM is currently receiving an educational grant from Medtronic for Postgraduate in Cardiac Electrophysiology and Pacing academic course. VV is currently receiving an EHRA educational grant sponsored by St Jude Medical.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}