{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T21:13:57Z","timestamp":1792790037984,"version":"4.5.0"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,1,12]],"date-time":"2021-01-12T00:00:00Z","timestamp":1610409600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,1,12]],"date-time":"2021-01-12T00:00:00Z","timestamp":1610409600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"published-print":{"date-parts":[[2021,6]]},"DOI":"10.1007\/s10840-020-00930-8","type":"journal-article","created":{"date-parts":[[2021,1,13]],"date-time":"2021-01-13T01:55:15Z","timestamp":1610502915000},"page":"1-10","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Electromagnetic interference between implantable cardiac devices and continuous-flow left ventricular assist devices: a review"],"prefix":"10.1007","volume":"61","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1610-7067","authenticated-orcid":false,"given":"Jonathan S.","family":"Gordon","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth J.","family":"Maynes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas J.","family":"O\u2019Malley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Behzad B.","family":"Pavri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vakhtang","family":"Tchantchaleishvili","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,1,12]]},"reference":[{"issue":"2","key":"930_CR1","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/j.athoracsur.2018.11.011","volume":"107","author":"RL Kormos","year":"2019","unstructured":"Kormos RL, Cowger J, Pagani FD, Teuteberg JJ, Goldstein DJ, Jacobs JP, et al. The Society of Thoracic Surgeons Intermacs Database Annual Report: evolving indications, outcomes, and scientific partnerships. Ann Thorac Surg. 2019;107(2):341\u201353. https:\/\/doi.org\/10.1016\/j.athoracsur.2018.11.011.","journal-title":"Ann Thorac Surg"},{"issue":"3","key":"930_CR2","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1016\/j.athoracsur.2019.12.005","volume":"109","author":"JJ Teuteberg","year":"2020","unstructured":"Teuteberg JJ, Cleveland JCJ, Cowger J, Higgins RS, Goldstein DJ, Keebler M, et al. The Society of Thoracic Surgeons Intermacs 2019 Annual Report: the changing landscape of devices and indications. Ann Thorac Surg. 2020;109(3):649\u201360. https:\/\/doi.org\/10.1016\/j.athoracsur.2019.12.005.","journal-title":"Ann Thorac Surg"},{"key":"930_CR3","doi-asserted-by":"publisher","unstructured":"Gordon JS, Maynes EJ, Choi JH, Wood CT, Weber MP, Morris RJ, et al. Ventricular arrhythmias following continuous-flow left ventricular assist device implantation: a systematic review. Artif Organs. 2020;44. https:\/\/doi.org\/10.1111\/aor.13665.","DOI":"10.1111\/aor.13665"},{"issue":"3","key":"930_CR4","doi-asserted-by":"publisher","first-page":"e6","DOI":"10.1016\/j.jacc.2012.11.007","volume":"61","author":"AE Epstein","year":"2013","unstructured":"Epstein AE, DiMarco JP, Ellenbogen KA, Estes NAM 3rd, Freedman RA, Gettes LS, et al. 2012 ACCF\/AHA\/HRS focused update incorporated into the ACCF\/AHA\/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation\/American Heart Association Task Force on Practice Guide. J Am Coll Cardiol. 2013;61(3):e6\u201375. https:\/\/doi.org\/10.1016\/j.jacc.2012.11.007.","journal-title":"J Am Coll Cardiol"},{"issue":"14","key":"930_CR5","doi-asserted-by":"publisher","first-page":"e011813","DOI":"10.1161\/JAHA.118.011813","volume":"8","author":"PA Alvarez","year":"2019","unstructured":"Alvarez PA, Sperry BW, P\u00e9rez AL, Yaranov DM, Randhawa V, Luthman J, et al. Implantable cardioverter defibrillators in patients with continuous flow left ventricular assist devices: utilization patterns, related procedures, and complications. J Am Heart Assoc. 2019;8(14):e011813. https:\/\/doi.org\/10.1161\/JAHA.118.011813.","journal-title":"J Am Heart Assoc"},{"issue":"4","key":"930_CR6","doi-asserted-by":"publisher","first-page":"668","DOI":"10.1161\/CIRCEP.113.000457","volume":"6","author":"AD Enriquez","year":"2013","unstructured":"Enriquez AD, Calenda B, Miller MA, Anyanwu AC, Pinney SP. The role of implantable cardioverter-defibrillators in patients with continuous flow left ventricular assist devices. Circ Arrhythm Electrophysiol. 2013;6(4):668\u201374. https:\/\/doi.org\/10.1161\/CIRCEP.113.000457.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"3","key":"930_CR7","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1007\/s10840-019-00619-7","volume":"56","author":"A Kumar","year":"2019","unstructured":"Kumar A, Tandon V, O\u2019Sullivan DM, Cronin E, Gluck J, Kluger J. ICD shocks in LVAD patients are not associated with increased subsequent mortality risk. J Int Cardiac Electrophysiol: Int J Arrhythmias Pacing. 2019;56(3):341\u20138. https:\/\/doi.org\/10.1007\/s10840-019-00619-7.","journal-title":"J Int Cardiac Electrophysiol: Int J Arrhythmias Pacing"},{"issue":"2","key":"930_CR8","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1161\/CIRCEP.110.957670","volume":"4","author":"SF Sears","year":"2011","unstructured":"Sears SF, Hauf JD, Kirian K, Hazelton G, Conti JB. Posttraumatic stress and the implantable cardioverter-defibrillator patient: what the electrophysiologist needs to know. Circ Arrhythm Electrophysiol. 2011;4(2):242\u201350. https:\/\/doi.org\/10.1161\/CIRCEP.110.957670.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"5","key":"930_CR9","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1097\/00000658-199911000-00005","volume":"230","author":"JD Madigan","year":"1999","unstructured":"Madigan JD, Choudhri AF, Chen J, Spotnitz HM, Oz MC, Edwards N. Surgical management of the patient with an implanted cardiac device: implications of electromagnetic interference. Ann Surg. 1999;230(5):639\u201347. https:\/\/doi.org\/10.1097\/00000658-199911000-00005.","journal-title":"Ann Surg"},{"issue":"10","key":"930_CR10","doi-asserted-by":"publisher","first-page":"1107","DOI":"10.1111\/j.1540-8167.2007.00805.x","volume":"18","author":"JC Matthews","year":"2007","unstructured":"Matthews JC, Betley D, Morady F, Pelosi FJ. Adverse interaction between a left ventricular assist device and an implantable cardioverter defibrillator. J Cardiovasc Electrophysiol. 2007;18(10):1107\u20138. https:\/\/doi.org\/10.1111\/j.1540-8167.2007.00805.x.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"7","key":"930_CR11","doi-asserted-by":"publisher","first-page":"945","DOI":"10.1111\/j.1540-8159.2009.02419.x","volume":"32","author":"A Biviano","year":"2009","unstructured":"Biviano A, Mancini D, Naka Y, Arellano J, Garan H. Overcoming electromagnetic interference by LVADs on ICD function by shielding the ICD programmer wand and extension cable. Pacing Clin Electrophysiol: PACE. 2009;32(7):945\u20138. https:\/\/doi.org\/10.1111\/j.1540-8159.2009.02419.x.","journal-title":"Pacing Clin Electrophysiol: PACE"},{"key":"930_CR12","doi-asserted-by":"publisher","first-page":"1613","DOI":"10.1016\/j.jacc.2008.01.025","volume":"51","author":"R Mehta","year":"2008","unstructured":"Mehta R, Doshi AA, Hasan AK, Love CJ, Pizzuto M, Sai-Sudhakar C, et al. Device interactions in patients with advanced cardiomyopathy. J Am Coll Cardiol U S. 2008;51:1613\u20134. https:\/\/doi.org\/10.1016\/j.jacc.2008.01.025.","journal-title":"J Am Coll Cardiol U S"},{"issue":"3","key":"930_CR13","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1007\/s10840-009-9415-6","volume":"28","author":"S Jacob","year":"2010","unstructured":"Jacob S, Cherian PK, Ghumman WS, Das MK. \u201cPseudo\u201d Faraday cage: a solution for telemetry link interaction between a left ventricular assist device and an implantable cardioverter defibrillator. J Int Cardiac Electrophysiol: Int J Arrhythmias Pacing. 2010;28(3):221\u20135. https:\/\/doi.org\/10.1007\/s10840-009-9415-6.","journal-title":"J Int Cardiac Electrophysiol: Int J Arrhythmias Pacing"},{"issue":"5","key":"930_CR14","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1510\/icvts.2009.202077","volume":"8","author":"H Oswald","year":"2009","unstructured":"Oswald H, Klein G, Struber M, Gardiwal A. Implantable defibrillator with left ventricular assist device compatibility. Interact Cardiovasc Thorac Surg. 2009;8(5):579\u201380. https:\/\/doi.org\/10.1510\/icvts.2009.202077.","journal-title":"Interact Cardiovasc Thorac Surg"},{"issue":"2","key":"930_CR15","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1007\/s10840-013-9854-y","volume":"39","author":"F Boudgh\u00e8ne-Stambouli","year":"2014","unstructured":"Boudgh\u00e8ne-Stambouli F, Boul\u00e9 S, Go\u00e9minne C, Botcherby E, Marqui\u00e9 C, Kouakam C, et al. Clinical implications of left ventricular assist device implantation in patients with an implantable cardioverter-defibrillator. J Interv Card Electrophysiol. 2014;39(2):177\u201384. https:\/\/doi.org\/10.1007\/s10840-013-9854-y.","journal-title":"J Interv Card Electrophysiol"},{"key":"930_CR16","doi-asserted-by":"publisher","first-page":"1887","DOI":"10.1016\/j.jacc.2008.04.073","volume":"52","author":"J-B le Polain de Waroux","year":"2008","unstructured":"le Polain de Waroux J-B, Marchandise S, Scavee C. Device interactions and cardiomyopathy. J Am Coll Cardiol U S. 2008;52:1887. https:\/\/doi.org\/10.1016\/j.jacc.2008.04.073.","journal-title":"J Am Coll Cardiol U S"},{"issue":"5","key":"930_CR17","doi-asserted-by":"publisher","first-page":"1380","DOI":"10.1016\/j.jtcvs.2008.02.072","volume":"136","author":"F Bakhtiary","year":"2008","unstructured":"Bakhtiary F, Therapidis P, Scherer M, Dzemali O, Moritz A, Kleine P. Electromagnetic interaction between an axial left ventricular assist device and an implantable cardioverter defibrillator. J Thorac Cardiovasc Surg. 2008;136(5):1380\u20131. https:\/\/doi.org\/10.1016\/j.jtcvs.2008.02.072.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"5","key":"930_CR18","doi-asserted-by":"publisher","first-page":"778","DOI":"10.1016\/j.hrthm.2010.11.026","volume":"8","author":"A Mozes","year":"2011","unstructured":"Mozes A, DeNofrio D, Pham DT, Homoud MK. Inappropriate implantable cardioverter-defibrillator therapy due to electromagnetic interference in patient with a HeartWare HVAD left ventricular assist device. Heart Rhythm. 2011;8(5):778\u201380. https:\/\/doi.org\/10.1016\/j.hrthm.2010.11.026.","journal-title":"Heart Rhythm"},{"issue":"3","key":"930_CR19","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1007\/s00399-017-0509-z","volume":"28","author":"D Duncker","year":"2017","unstructured":"Duncker D, Konig T, Muller-Leisse J, Michalski R, Oswald H, Schmitto JD, et al. Electric smog: telemetry interference between ICD and LVAD. Herzschrittmacherther Elektrophysiol. 2017;28(3):257\u20139. https:\/\/doi.org\/10.1007\/s00399-017-0509-z.","journal-title":"Herzschrittmacherther Elektrophysiol"},{"issue":"10","key":"930_CR20","doi-asserted-by":"publisher","first-page":"914","DOI":"10.1002\/clc.23228","volume":"42","author":"C Schukro","year":"2019","unstructured":"Schukro C, Schl\u00f6glhofer T, Khazen C, R\u00f6hrich M, Laufer G, Zimpfer D, et al. Influence of a fully magnetically levitated left ventricular assist device on functional interrogation of implantable cardioverter defibrillators. Clin Cardiol. 2019;42(10):914\u20138. https:\/\/doi.org\/10.1002\/clc.23228.","journal-title":"Clin Cardiol"},{"key":"930_CR21","doi-asserted-by":"publisher","unstructured":"Yalcin, Y. C., Kooij, C., Theuns, D. A. M. J., Constantinescu, A. A., Brugts, J. J., Manintveld, O. C., \u2026 Caliskan, K. (2020). Emerging electromagnetic interferences between implantable cardioverter-defibrillators and left ventricular assist devices. Europace euaa006. https:\/\/doi.org\/10.1093\/europace\/euaa006","DOI":"10.1093\/europace\/euaa006"},{"key":"930_CR22","unstructured":"HeartMate 3 Left Ventricular Assist System IFU and Manuals (USA). Thoratec Corporation. 2017. Retrieved March 10, 2020, from https:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf16\/P160054C.pdf."},{"key":"930_CR23","unstructured":"Technical Information Piece. ICD and CRT-D Interaction with Heartmate III LVAD. Biotronik. 2017."},{"issue":"1","key":"930_CR24","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1111\/anec.12181","volume":"20","author":"SC Martinez","year":"2015","unstructured":"Martinez SC, Fansler D, Lau J, Novak EL, Joseph SM, Kleiger RE. Characteristics of the electrocardiogram in patients with continuous-flow left ventricular assist devices. Ann Noninvasive Electrocardiol. 2015;20(1):62\u20138. https:\/\/doi.org\/10.1111\/anec.12181.","journal-title":"Ann Noninvasive Electrocardiol"},{"key":"930_CR25","doi-asserted-by":"publisher","unstructured":"L\u00f3pez-Gil M, Fontenla A, Delgado JF, Rodr\u00edguez-Mu\u00f1oz D, Papageorgiou N, Iliodromitis K, et al. Subcutaneous implantable cardioverter defibrillators in patients with left ventricular assist devices: case report and comprehensive review. Eur Heart J - Case Rep. 2019;3(2). https:\/\/doi.org\/10.1093\/ehjcr\/ytz057.","DOI":"10.1093\/ehjcr\/ytz057"},{"key":"930_CR26","doi-asserted-by":"publisher","unstructured":"Pfeffer TJ, Konig T, Duncker D, Michalski R, Hohmann S, Oswald H, et al. Subcutaneous implantable cardioverter-defibrillator shocks after left ventricular assist device implantation. Circ Arrhythm Electrophysiol. 2016;9(11). https:\/\/doi.org\/10.1161\/CIRCEP.116.004633.","DOI":"10.1161\/CIRCEP.116.004633"},{"issue":"3","key":"930_CR27","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1111\/pace.13273","volume":"41","author":"H Saini","year":"2018","unstructured":"Saini H, Saini A, Leffler J, Eddy S, Ellenbogen KA. Subcutaneous implantable cardioverter defibrillator (S-ICD) shocks in a patient with a left ventricular assist device. Pacing Clin Electrophysiol: PACE. 2018;41(3):309\u201311. https:\/\/doi.org\/10.1111\/pace.13273.","journal-title":"Pacing Clin Electrophysiol: PACE"},{"key":"930_CR28","doi-asserted-by":"publisher","first-page":"477","DOI":"10.1111\/jce.13433","volume":"29","author":"AS Ahmed","year":"2018","unstructured":"Ahmed AS, Patel PJ, Bagga S, Gilge JL, Schleeter T, Lakhani BA, et al. Troubleshooting electromagnetic interference in a patient with centrifugal flow left ventricular assist device and subcutaneous implantable cardioverter defibrillator. J Cardiovasc Electrophysiol U S. 2018, March;29:477\u201381. https:\/\/doi.org\/10.1111\/jce.13433.","journal-title":"J Cardiovasc Electrophysiol U S"},{"issue":"3","key":"930_CR29","doi-asserted-by":"publisher","first-page":"e32","DOI":"10.1161\/CIRCEP.113.000240","volume":"6","author":"D Saeed","year":"2013","unstructured":"Saeed D, Albert A, Westenfeld R, Maxhera B, Gramsch-Zabel H, O\u2019Connor S, et al. Left ventricular assist device in a patient with a concomitant subcutaneous implantable cardioverter defibrillator. Circ Arrhythm Electrophysiol. 2013;6(3):e32\u20133. https:\/\/doi.org\/10.1161\/CIRCEP.113.000240.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"2","key":"930_CR30","doi-asserted-by":"publisher","first-page":"140","DOI":"10.14503\/THIJ-14-4166","volume":"42","author":"A Gupta","year":"2015","unstructured":"Gupta A, Subzposh F, Hankins SR, Kutalek SP. Subcutaneous implantable cardioverter-defibrillator implantation in a patient with a left ventricular assist device already in place. Tex Heart Inst J. 2015;42(2):140\u20133. https:\/\/doi.org\/10.14503\/THIJ-14-4166.","journal-title":"Tex Heart Inst J"},{"issue":"2","key":"930_CR31","doi-asserted-by":"publisher","first-page":"183","DOI":"10.14503\/THIJ-14-4795","volume":"43","author":"AS Raman","year":"2016","unstructured":"Raman AS, Shabari FR, Kar B, Loyalka P, Hariharan R. No Electromagnetic Interference Occurred in a Patient with a HeartMate II Left Ventricular Assist System and a Subcutaneous Implantable Cardioverter-Defibrillator. Tex Heart Inst J. 2016;43(2):183\u20135. https:\/\/doi.org\/10.14503\/THIJ-14-4795.","journal-title":"Tex Heart Inst J"},{"issue":"2","key":"930_CR32","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1016\/j.jacep.2015.10.008","volume":"2","author":"F Migliore","year":"2016","unstructured":"Migliore F, Leoni L, Bottio T, Siciliano M, Ferretto S, Gerosa G, et al. Subcutaneous implantable cardioverter-defibrillator and left ventricular assist device: a safe and effective approach for refractory heart failure. JACC Clin Electrophysiol. 2016;2(2):246\u20137. https:\/\/doi.org\/10.1016\/j.jacep.2015.10.008.","journal-title":"JACC Clin Electrophysiol"},{"issue":"23","key":"930_CR33","doi-asserted-by":"publisher","first-page":"2579","DOI":"10.1016\/j.jacc.2015.09.083","volume":"66","author":"I Netuka","year":"2015","unstructured":"Netuka I, Sood P, Pya Y, Zimpfer D, Krabatsch T, Garbade J, et al. Fully magnetically levitated left ventricular assist system for treating advanced HF: a multicenter study. J Am Coll Cardiol. 2015;66(23):2579\u201389. https:\/\/doi.org\/10.1016\/j.jacc.2015.09.083.","journal-title":"J Am Coll Cardiol"},{"issue":"3","key":"930_CR34","doi-asserted-by":"publisher","first-page":"e52","DOI":"10.1111\/j.1540-8159.2010.02854.x","volume":"35","author":"P Reddy","year":"2012","unstructured":"Reddy P, Benditt DG, Adabag S. Electromagnetic device-device interaction between a new generation implantable pacemaker and left ventricular assist device: recognition and potential solutions. Pacing Clin Electrophysiol: PACE. 2012;35(3):e52\u20134. https:\/\/doi.org\/10.1111\/j.1540-8159.2010.02854.x.","journal-title":"Pacing Clin Electrophysiol: PACE"},{"issue":"6","key":"930_CR35","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1016\/j.hrcr.2016.06.008","volume":"2","author":"M Murphy","year":"2016","unstructured":"Murphy M, Welch T, Shaw PW, Kennedy JLW, Bilchick KC. Inhibition of pacing in a dependent patient with an implantable cardioverter-defibrillator and a left ventricular assist device. HeartRhythm Case Rep. 2016;2(6):473\u20137. https:\/\/doi.org\/10.1016\/j.hrcr.2016.06.008.","journal-title":"HeartRhythm Case Rep"},{"key":"930_CR36","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2018\/6195045","volume":"2018","author":"S Erqou","year":"2018","unstructured":"Erqou S, Kormos RL, Wang NC, McNamara DM, Bazaz R. Electromagnetic interference from left ventricular assist device (LVAD) inhibiting the pacing function of an implantable cardioverter-defibrillator (ICD) device. Case Rep Cardiol U S. 2018;2018:1\u20134. https:\/\/doi.org\/10.1155\/2018\/6195045.","journal-title":"Case Rep Cardiol U S"},{"key":"930_CR37","doi-asserted-by":"publisher","first-page":"510","DOI":"10.1016\/j.ijcard.2014.11.021","volume":"179","author":"J Yokota","year":"2015","unstructured":"Yokota J, Fujiu K, Tanimito H, Nebiya H, Kashiwa K, Kinoshita O, et al. Electromagnetic interference between continuous-flow left ventricular assist device and cardiac resynchronization therapy defibrillator due to an unrecognized mechanism. Int J Cardiol. 2015;179:510\u20133. https:\/\/doi.org\/10.1016\/j.ijcard.2014.11.021.","journal-title":"Int J Cardiol"},{"issue":"10","key":"930_CR38","doi-asserted-by":"publisher","first-page":"1109","DOI":"10.1111\/jce.12455","volume":"25","author":"S Pecha","year":"2014","unstructured":"Pecha S, Wilke I, Bernhardt A, Hakmi S, Yildirim Y, Steven D, et al. Clinical experience of combined HeartWare ventricular assist device and implantable cardioverter defibrillator therapy. J Cardiovasc Electrophysiol. 2014;25(10):1109\u201314. https:\/\/doi.org\/10.1111\/jce.12455.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"14","key":"930_CR39","doi-asserted-by":"publisher","first-page":"1357","DOI":"10.1016\/j.jacc.2007.09.073","volume":"51","author":"JP Daubert","year":"2008","unstructured":"Daubert JP, Zareba W, Cannom DS, McNitt S, Rosero SZ, Wang P, et al. Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact. J Am Coll Cardiol. 2008;51(14):1357\u201365. https:\/\/doi.org\/10.1016\/j.jacc.2007.09.073.","journal-title":"J Am Coll Cardiol"},{"issue":"5","key":"930_CR40","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1016\/j.jacc.2010.06.059","volume":"57","author":"JB van Rees","year":"2011","unstructured":"van Rees JB, Borleffs CJW, de Bie MK, Stijnen T, van Erven L, Bax JJ, et al. Inappropriate implantable cardioverter-defibrillator shocks: incidence, predictors, and impact on mortality. J Am Coll Cardiol. 2011;57(5):556\u201362. https:\/\/doi.org\/10.1016\/j.jacc.2010.06.059.","journal-title":"J Am Coll Cardiol"},{"key":"930_CR41","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.ahj.2017.03.009","volume":"189","author":"AP Perini","year":"2017","unstructured":"Perini AP, Kutyifa V, Veazie P, Daubert JP, Schuger C, Zareba W, et al. Effects of implantable cardioverter\/defibrillator shock and antitachycardia pacing on anxiety and quality of life: a MADIT-RIT substudy. Am Heart J. 2017;189:75\u201384. https:\/\/doi.org\/10.1016\/j.ahj.2017.03.009.","journal-title":"Am Heart J"},{"issue":"Suppl 6","key":"930_CR42","doi-asserted-by":"publisher","first-page":"S853","DOI":"10.21037\/jtd.2018.10.37","volume":"11","author":"S Hohmann","year":"2019","unstructured":"Hohmann S, Veltmann C, Duncker D, Konig T, Berliner D, Hanke J, et al. Initial experience with telemonitoring in left ventricular assist device patients. J Thorac Dis. 2019;11(Suppl 6):S853\u201363. https:\/\/doi.org\/10.21037\/jtd.2018.10.37.","journal-title":"J Thorac Dis"},{"key":"930_CR43","unstructured":"FDA. Premarket approval of medtronic micra transcatheter pacemaker system. 2016."},{"issue":"12","key":"930_CR44","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.1056\/NEJMoa1507192","volume":"373","author":"VY Reddy","year":"2015","unstructured":"Reddy VY, Exner DV, Cantillon DJ, Doshi R, Bunch TJ, Tomassoni GF, et al. Percutaneous Implantation of an Entirely Intracardiac Leadless Pacemaker. N Engl J Med. 2015;373(12):1125\u201335. https:\/\/doi.org\/10.1056\/NEJMoa1507192.","journal-title":"N Engl J Med"},{"issue":"5","key":"930_CR45","doi-asserted-by":"publisher","first-page":"702","DOI":"10.1016\/j.hrthm.2017.01.035","volume":"14","author":"GZ Duray","year":"2017","unstructured":"Duray GZ, Ritter P, El-Chami M, Narasimhan C, Omar R, Tolosana JM, et al. Long-term performance of a transcatheter pacing system: 12-Month results from the Micra Transcatheter Pacing Study. Heart Rhythm. 2017;14(5):702\u20139. https:\/\/doi.org\/10.1016\/j.hrthm.2017.01.035.","journal-title":"Heart Rhythm"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-020-00930-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-020-00930-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-020-00930-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,11]],"date-time":"2021-06-11T05:51:53Z","timestamp":1623390713000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-020-00930-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,12]]},"references-count":45,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,6]]}},"alternative-id":["930"],"URL":"https:\/\/doi.org\/10.1007\/s10840-020-00930-8","relation":{},"ISSN":["1383-875X","1572-8595"],"issn-type":[{"value":"1383-875X","type":"print"},{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,12]]},"assertion":[{"value":"25 August 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 December 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 January 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest\/Competing interests"}},{"value":"Not applicable","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Code availability (software application or custom code)"}}]}}