{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,6]],"date-time":"2026-05-06T22:31:43Z","timestamp":1778106703502,"version":"3.51.4"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2022,2,22]],"date-time":"2022-02-22T00:00:00Z","timestamp":1645488000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,2,22]],"date-time":"2022-02-22T00:00:00Z","timestamp":1645488000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"abstract":"<jats:title>Abstract\n<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>The DiamondTemp ablation (DTA) catheter system delivers high power, open-irrigated, temperature-controlled radiofrequency (RF) ablation. This novel ablation system has not been previously used for ventricular tachycardia (VT) ablation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>Feasibility of using the DTA catheter system for VT ablation in ischaemic cardiomyopathy (ICM) patients<jats:italic>.<\/jats:italic>\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Method<\/jats:title>\n            <jats:p>Ten ICM patients with optimal anti-arrhythmic drug therapy and implantable cardiac defibrillators (ICD) were recruited. VT inducibility testing was performed at the end of the procedure. ICD data for device detected VT episodes and device treated VT episodes were collected for 6-months pre- and post-ablation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Substrate analysis demonstrated reductions in the borderzone area of 4.4 cm<jats:sup>2<\/jats:sup> (<jats:italic>p<\/jats:italic>\u2009=\u20090.026) and late potential area of 3.5 cm<jats:sup>2<\/jats:sup> (<jats:italic>p<\/jats:italic>\u2009=\u20090.0449) post-ablation, with reductions in the mean bipolar and unipolar voltages of the ablation target areas (0.14\u00a0mV (<jats:italic>p<\/jats:italic>\u2009=\u20090.0007); 0.59\u00a0mV (<jats:italic>p<\/jats:italic>\u2009=\u20090.0072) respectively). Complete procedural success was achieved in 9 procedures. Post-ablation VT inducibility testing was not performed in 1 procedure due to a steam pop complication resulting in pericardial tamponade requiring drainage. Mean follow-up of 214\u2009\u00b1\u200933\u00a0days revealed an 88% reduction in total VT episodes (<jats:italic>n<\/jats:italic>\u2009=\u2009266 median 16 [IQR 3\u201357] to <jats:italic>n<\/jats:italic>\u2009=\u200933 median 0; <jats:italic>p<\/jats:italic>\u2009=\u20090.0164) and 77% reduction in ICD therapies (<jats:italic>n<\/jats:italic>\u2009=\u2009128 median 5 [IQR 2\u201315] to <jats:italic>n<\/jats:italic>\u2009=\u200930 median 0; <jats:italic>p<\/jats:italic>\u2009=\u20090.0181).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>The DTA system resulted in adequate lesion characteristics with effective substrate modification, acute procedural success and improved outcomes at intermediate-term follow-up. Randomised controlled trials are required to compare the performance of the DTA system against conventional ablation catheters.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1007\/s10840-022-01158-4","type":"journal-article","created":{"date-parts":[[2022,2,22]],"date-time":"2022-02-22T09:04:31Z","timestamp":1645520671000},"page":"551-559","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Initial experience of temperature-controlled irrigated radiofrequency ablation for ischaemic cardiomyopathy ventricular tachycardia ablation"],"prefix":"10.1007","volume":"66","author":[{"given":"Jaffar","family":"Al-Sheikhli","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ian","family":"Patchett","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ven Gee","family":"Lim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Leeann","family":"Marshall","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Will","family":"Foster","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Kuehl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shamil","family":"Yusuf","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sandeep","family":"Panikker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kiran","family":"Patel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Faizel","family":"Osman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Prithwish","family":"Banerjee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicolas","family":"Lellouche","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5806-8567","authenticated-orcid":false,"given":"Tarvinder","family":"Dhanjal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,2,22]]},"reference":[{"key":"1158_CR1","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1056\/NEJMoa1513614","volume":"375","author":"JL Sapp","year":"2016","unstructured":"Sapp JL, Wells GA, Parkash R, et al. Ventricular tachycardia ablation versus escalation of antiarrhythmic drugs. N Engl J Med. 2016;375:111\u201321.","journal-title":"N Engl J Med"},{"key":"1158_CR2","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/S0140-6736(09)61755-4","volume":"375","author":"KH Kuck","year":"2010","unstructured":"Kuck KH, Schaumann A, Eckardt L, et al. Catheter ablation of stable ventricular tachycardia before defibrillator implantation in patients with coronary heart disease (VTACH): a multicentre randomised controlled trial. Lancet. 2010;375:31\u201340.","journal-title":"Lancet"},{"key":"1158_CR3","doi-asserted-by":"publisher","first-page":"2657","DOI":"10.1056\/NEJMoa065457","volume":"357","author":"VY Reddy","year":"2007","unstructured":"Reddy VY, Reynolds MR, Neuzil P, et al. Prophylactic catheter ablation for the prevention of defibrillator therapy. N Engl J Med. 2007;357:2657\u201365.","journal-title":"N Engl J Med"},{"key":"1158_CR4","doi-asserted-by":"publisher","first-page":"1034","DOI":"10.1161\/01.CIR.82.3.1034","volume":"82","author":"DE Haines","year":"1990","unstructured":"Haines DE, Verow AF. Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium. Circulation. 1990;82:1034\u20138.","journal-title":"Circulation"},{"key":"1158_CR5","doi-asserted-by":"publisher","first-page":"352","DOI":"10.1016\/j.jacep.2020.11.009","volume":"7","author":"J Kautzner","year":"2021","unstructured":"Kautzner J, Albenque JP, Natale A, et al. A novel temperature-controlled radiofrequency catheter ablation system used to treat patients with paroxysmal atrial fibrillation. JACC Clin Electrophysiol. 2021;7:352\u201363.","journal-title":"JACC Clin Electrophysiol"},{"key":"1158_CR6","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1161\/CIRCULATIONAHA.105.540062","volume":"113","author":"K Yokoyama","year":"2006","unstructured":"Yokoyama K, Nakagawa H, Wittkampf FH, Pitha JV, Lazzara R, Jackman WM. Comparison of electrode cooling between internal and open irrigation in radiofrequency ablation lesion depth and incidence of thrombus and steam pop. Circulation. 2006;113:11\u20139.","journal-title":"Circulation"},{"key":"1158_CR7","doi-asserted-by":"publisher","first-page":"542","DOI":"10.1016\/j.jacc.2017.06.008","volume":"70","author":"J Iwasawa","year":"2017","unstructured":"Iwasawa J, Koruth JS, Petru J, et al. Temperature-controlled radiofrequency ablation for pulmonary vein isolation in patients with atrial fibrillation. J Am Coll Cardiol. 2017;70:542\u201353.","journal-title":"J Am Coll Cardiol"},{"key":"1158_CR8","doi-asserted-by":"crossref","unstructured":"Verma A, Schmidt MM, Lalonde JP, Ramirez DA, Getman MK. Assessing the relationship of applied force and ablation duration on lesion size using a diamond tip catheter ablation system. Circ Arrhythm Electrophysiol 2021;14:e009541.","DOI":"10.1161\/CIRCEP.120.009541"},{"key":"1158_CR9","doi-asserted-by":"crossref","unstructured":"Proietti R, Dowd R, Gee LV et al. Impact of a high-density grid catheter on long-term outcomes for structural heart disease ventricular tachycardia ablation. J Interv Card Electrophysiol 2021.","DOI":"10.1007\/s10840-020-00918-4"},{"key":"1158_CR10","doi-asserted-by":"publisher","first-page":"1288","DOI":"10.1161\/01.CIR.101.11.1288","volume":"101","author":"FE Marchlinski","year":"2000","unstructured":"Marchlinski FE, Callans DJ, Gottlieb CD, Zado E. Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy. Circulation. 2000;101:1288\u201396.","journal-title":"Circulation"},{"key":"1158_CR11","doi-asserted-by":"publisher","first-page":"282","DOI":"10.15420\/aer.2018.36.3","volume":"7","author":"D Muser","year":"2018","unstructured":"Muser D, Castro SA, Liang JJ, Santangeli P. Identifying risk and management of acute haemodynamic decompensation during catheter ablation of ventricular tachycardia. Arrhythm Electrophysiol Rev. 2018;7:282\u20137.","journal-title":"Arrhythm Electrophysiol Rev"},{"key":"1158_CR12","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1016\/j.jacep.2017.11.018","volume":"4","author":"E Leshem","year":"2018","unstructured":"Leshem E, Zilberman I, Tschabrunn CM, et al. High-power and short-duration ablation for pulmonary vein isolation: biophysical characterization. JACC Clin Electrophysiol. 2018;4:467\u201379.","journal-title":"JACC Clin Electrophysiol"},{"key":"1158_CR13","doi-asserted-by":"publisher","first-page":"1165","DOI":"10.1111\/jce.12477","volume":"25","author":"T Bourke","year":"2014","unstructured":"Bourke T, Buch E, Mathuria N, et al. Biophysical parameters during radiofrequency catheter ablation of scar-mediated ventricular tachycardia: epicardial and endocardial applications via manual and magnetic navigation. J Cardiovasc Electrophysiol. 2014;25:1165\u201373.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"1158_CR14","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1016\/j.hrthm.2013.10.048","volume":"11","author":"T Reichlin","year":"2014","unstructured":"Reichlin T, Knecht S, Lane C, et al. Initial impedance decrease as an indicator of good catheter contact: insights from radiofrequency ablation with force sensing catheters. Heart Rhythm. 2014;11:194\u2013201.","journal-title":"Heart Rhythm"},{"key":"1158_CR15","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1007\/s10840-019-00691-z","volume":"59","author":"K Yazaki","year":"2020","unstructured":"Yazaki K, Ejima K, Kanai M, et al. Impedance drop predicts acute electrical reconnection of the pulmonary vein-left atrium after pulmonary vein isolation using short-duration high-power exposure. J Interv Card Electrophysiol. 2020;59:575\u201384.","journal-title":"J Interv Card Electrophysiol"},{"key":"1158_CR16","doi-asserted-by":"crossref","unstructured":"Shi LB, Wang YC, Chu SY et al. The impacts of contact force, power and application time on ablation effect indicated by serial measurements of impedance drop in both conventional and high-power short-duration ablation settings of atrial fibrillation. J Interv Card Electrophysiol 2021.","DOI":"10.1007\/s10840-021-00990-4"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-022-01158-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-022-01158-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-022-01158-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,5]],"date-time":"2025-09-05T17:17:36Z","timestamp":1757092656000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-022-01158-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,22]]},"references-count":16,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2023,4]]}},"alternative-id":["1158"],"URL":"https:\/\/doi.org\/10.1007\/s10840-022-01158-4","relation":{},"ISSN":["1572-8595"],"issn-type":[{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,22]]},"assertion":[{"value":"31 December 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 February 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 February 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}