{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T20:05:47Z","timestamp":1769976347405,"version":"3.49.0"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2022,5,18]],"date-time":"2022-05-18T00:00:00Z","timestamp":1652832000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,5,18]],"date-time":"2022-05-18T00:00:00Z","timestamp":1652832000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"EPIX Therapeutics"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"DOI":"10.1007\/s10840-022-01234-9","type":"journal-article","created":{"date-parts":[[2022,5,18]],"date-time":"2022-05-18T01:03:21Z","timestamp":1652835801000},"page":"343-351","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Radiofrequency ablation using the second-generation temperature-controlled diamond tip system in paroxysmal and persistent atrial fibrillation: results from FASTR-AF"],"prefix":"10.1007","volume":"66","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4334-8165","authenticated-orcid":false,"given":"Petr","family":"Neuzil","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Herve","family":"Poty","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"de Chillou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan","family":"Petru","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2850-3756","authenticated-orcid":false,"given":"Michael K.","family":"Getman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shufeng","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1620-3924","authenticated-orcid":false,"given":"Moritoshi","family":"Funasako","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexis","family":"Durand-Dubief","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"St\u00e9phane","family":"Combes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean-Paul","family":"Albenque","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,5,18]]},"reference":[{"issue":"10","key":"1234_CR1","doi-asserted-by":"publisher","first-page":"e275","DOI":"10.1016\/j.hrthm.2017.05.012","volume":"14","author":"H Calkins","year":"2017","unstructured":"Calkins H, Hindricks G, Cappato R, et al. 2017 HRS\/EHRA\/ECAS\/APHRS\/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. Heart Rhythm. 2017;14(10):e275\u2013444.","journal-title":"Heart Rhythm"},{"issue":"10","key":"1234_CR2","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1056\/NEJM199809033391003","volume":"339","author":"M Ha\u00efssaguerre","year":"1998","unstructured":"Ha\u00efssaguerre M, Ja\u00efs P, Shah DC, et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med. 1998;339(10):659\u201366.","journal-title":"N Engl J Med"},{"issue":"19","key":"1234_CR3","doi-asserted-by":"publisher","first-page":"1812","DOI":"10.1056\/NEJMoa1408288","volume":"372","author":"A Verma","year":"2015","unstructured":"Verma A, Jiang CY, Betts TR, et al. Approaches to catheter ablation for persistent atrial fibrillation. N Engl J Med. 2015;372(19):1812\u201322.","journal-title":"N Engl J Med"},{"issue":"2","key":"1234_CR4","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1161\/CIRCEP.113.000374","volume":"6","author":"P Neuzil","year":"2013","unstructured":"Neuzil P, Reddy VY, Kautzner J, et al. Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study. Circ Arrhythm Electrophysiol. 2013;6(2):327\u201333.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"8","key":"1234_CR5","doi-asserted-by":"publisher","first-page":"1229","DOI":"10.1093\/europace\/euv057","volume":"17","author":"J Kautzner","year":"2015","unstructured":"Kautzner J, Neuzil P, Lambert H, et al. EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation. Europace. 2015;17(8):1229\u201335.","journal-title":"Europace"},{"issue":"6","key":"1234_CR6","doi-asserted-by":"publisher","first-page":"602","DOI":"10.1016\/j.jacep.2017.01.016","volume":"3","author":"M Das","year":"2017","unstructured":"Das M, Wynn GJ, Saeed Y, et al. Pulmonary vein re-isolation as a routine strategy regardless of symptoms: the PRESSURE randomized controlled trial. JACC Clin Electrophysiol. 2017;3(6):602\u201311.","journal-title":"JACC Clin Electrophysiol"},{"issue":"5","key":"1234_CR7","doi-asserted-by":"publisher","first-page":"542","DOI":"10.1016\/j.jacc.2017.06.008","volume":"70","author":"J Iwasawa","year":"2017","unstructured":"Iwasawa J, Koruth JS, Petru J, et al. Temperature-controlled radiofrequency ablation for pulmonary vein isolation in patients with atrial fibrillation. J Am Coll Cardiol. 2017;70(5):542\u201353.","journal-title":"J Am Coll Cardiol"},{"issue":"9","key":"1234_CR8","doi-asserted-by":"publisher","first-page":"e006576","DOI":"10.1161\/CIRCEP.118.006576","volume":"11","author":"A Hussein","year":"2018","unstructured":"Hussein A, Das M, Riva S, et al. Use of ablation index-guided ablation results in high rates of durable pulmonary vein isolation and freedom from arrhythmia in persistent atrial fibrillation patients: the PRAISE study results. Circ Arrhythm Electrophysiol. 2018;11(9):e006576.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"4","key":"1234_CR9","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.ipej.2019.05.001","volume":"19","author":"R Pranata","year":"2019","unstructured":"Pranata R, Vania R, Huang I. Ablation-index guided versus conventional contact-force guided ablation in pulmonary vein isolation - systematic review and meta-analysis. Indian Pacing Electrophysiol J. 2019;19(4):155\u201360.","journal-title":"Indian Pacing Electrophysiol J"},{"issue":"11","key":"1234_CR10","doi-asserted-by":"publisher","first-page":"1659","DOI":"10.1093\/europace\/euaa224","volume":"22","author":"A Ioannou","year":"2020","unstructured":"Ioannou A, Papageorgiou N, Lim WY, et al. Efficacy and safety of ablation index-guided catheter ablation for atrial fibrillation: an updated meta-analysis. Europace. 2020;22(11):1659\u201371.","journal-title":"Europace"},{"issue":"3","key":"1234_CR11","doi-asserted-by":"publisher","first-page":"528","DOI":"10.1111\/pace.14167","volume":"44","author":"A Naniwadekar","year":"2021","unstructured":"Naniwadekar A, Dukkipati SR. High-power short-duration ablation of atrial fibrillation: a contemporary review. Pacing Clin Electrophysiol. 2021;44(3):528\u201340. https:\/\/doi.org\/10.1111\/pace.14167 (Epub 2021 Jan 31).","journal-title":"Pacing Clin Electrophysiol"},{"issue":"11","key":"1234_CR12","doi-asserted-by":"publisher","first-page":"962","DOI":"10.1093\/europace\/eul100","volume":"8","author":"B Nilsson","year":"2006","unstructured":"Nilsson B, Chen X, Pehrson S, Svendsen JH. The effectiveness of a high output\/short duration radiofrequency current application technique in segmental pulmonary vein isolation for atrial fibrillation. Europace. 2006;8(11):962\u20135.","journal-title":"Europace"},{"issue":"4","key":"1234_CR13","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1016\/j.hrthm.2007.11.007","volume":"5","author":"TJ Bunch","year":"2008","unstructured":"Bunch TJ, Day JD. Novel ablative approach for atrial fibrillation to decrease risk of esophageal injury. Heart Rhythm. 2008;5(4):624\u20137.","journal-title":"Heart Rhythm"},{"issue":"9","key":"1234_CR14","doi-asserted-by":"publisher","first-page":"2499","DOI":"10.1111\/jce.14649","volume":"31","author":"J Qiu","year":"2020","unstructured":"Qiu J, Wang Y, Wang DW, Hu M, Chen G. Update on high-power short-duration ablation for pulmonary vein isolation. J Cardiovasc Electrophysiol. 2020;31(9):2499\u2013508.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"1234_CR15","doi-asserted-by":"publisher","DOI":"10.1111\/jce.14863","author":"RA Winkle","year":"2020","unstructured":"Winkle RA. HPSD ablation for AF high-power short-duration RF ablation for atrial fibrillation: a review. J Cardiovasc Electrophysiol. 2020. https:\/\/doi.org\/10.1111\/jce.14863 (Epub ahead of print).","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"5","key":"1234_CR16","first-page":"S218","volume":"15","author":"W Stoffregen","year":"2018","unstructured":"Stoffregen W, Maddox W, Couco F. B-PO02-094 \u2013 temperature sensing accuracy and lesion characteristics of a novel, diamond tip, temperature-controlled open irrigated radiofrequency catheter. Heart Rhythm. 2018;15(5):S218.","journal-title":"Heart Rhythm"},{"issue":"7","key":"1234_CR17","doi-asserted-by":"publisher","first-page":"e009541","DOI":"10.1161\/CIRCEP.120.009541","volume":"14","author":"A Verma","year":"2021","unstructured":"Verma A, Schmidt MM, Lalonde JP, Ramirez DA, Getman MK. Assessing the relationship of applied force and ablation duration on lesion size using a diamond tip catheter ablation system. Circ Arrhythm Electrophysiol. 2021;14(7):e009541.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"3","key":"1234_CR18","doi-asserted-by":"publisher","first-page":"352","DOI":"10.1016\/j.jacep.2020.11.009","volume":"7","author":"J Kautzner","year":"2021","unstructured":"Kautzner J, Albenque JP, Natale A, et al. A novel temperature-controlled radiofrequency catheter ablation system used to treat patients with paroxysmal atrial fibrillation. JACC Clin Electrophysiol. 2021;7(3):352\u201363.","journal-title":"JACC Clin Electrophysiol"},{"key":"1234_CR19","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-021-00986-0","author":"Z Starek","year":"2021","unstructured":"Starek Z, Lehar F, Jez J, et al. Efficacy and safety of novel temperature-controlled radiofrequency ablation system during pulmonary vein isolation in patients with paroxysmal atrial fibrillation: TRAC-AF study. J Interv Card Electrophysiol. 2021. https:\/\/doi.org\/10.1007\/s10840-021-00986-0 (Epub ahead of print).","journal-title":"J Interv Card Electrophysiol"},{"issue":"8","key":"1234_CR20","doi-asserted-by":"publisher","first-page":"958","DOI":"10.1016\/j.jacep.2020.04.024","volume":"6","author":"M Mansour","year":"2020","unstructured":"Mansour M, Calkins H, Osorio J, et al. Persistent atrial fibrillation ablation with contact force-sensing catheter: the prospective multicenter PRECEPT trial. JACC Clin Electrophysiol. 2020;6(8):958\u201369.","journal-title":"JACC Clin Electrophysiol"},{"issue":"FI_3","key":"1234_CR21","doi-asserted-by":"publisher","first-page":"f392","DOI":"10.1093\/europace\/eux264","volume":"20","author":"LA Chinitz","year":"2018","unstructured":"Chinitz LA, Melby DP, Marchlinski FE, et al. Safety and efficiency of porous-tip contact-force catheter for drug-refractory symptomatic paroxysmal atrial fibrillation ablation: results from the SMART SF trial. Europace. 2018;20(FI_3):f392\u2013400.","journal-title":"Europace"},{"key":"1234_CR22","unstructured":"Neuzil P, Poty H, de Chillou C, et al. AFS2022\u201334 - procedural efficiencies using a novel diamond tip radiofrequency ablation catheter when treating atrial fibirllation.Abstracts from the 27th Annual International Atrial Fibrillation Symposium January 13\u201315, 2022. J Cardiovasc Electrophysiol. 2022."}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-022-01234-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-022-01234-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-022-01234-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,2]],"date-time":"2023-03-02T17:11:14Z","timestamp":1677777074000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-022-01234-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,18]]},"references-count":22,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2023,3]]}},"alternative-id":["1234"],"URL":"https:\/\/doi.org\/10.1007\/s10840-022-01234-9","relation":{},"ISSN":["1572-8595"],"issn-type":[{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,18]]},"assertion":[{"value":"25 March 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 April 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 May 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The Institutional Review Boards of each participating center reviewed and approved the study protocol. Written informed consent was obtained from all patients in accordance with the Declaration of Helsinki.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"MKG and SL receive compensation as employees of Medtronic, Inc. All other authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}