{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,22]],"date-time":"2025-12-22T07:59:52Z","timestamp":1766390392954},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2022,9,2]],"date-time":"2022-09-02T00:00:00Z","timestamp":1662076800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,9,2]],"date-time":"2022-09-02T00:00:00Z","timestamp":1662076800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"published-print":{"date-parts":[[2022,12]]},"DOI":"10.1007\/s10840-022-01361-3","type":"journal-article","created":{"date-parts":[[2022,9,2]],"date-time":"2022-09-02T16:03:27Z","timestamp":1662134607000},"page":"765-772","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Predictors of high-degree atrioventricular block in patients with new-onset left bundle branch block following transcatheter aortic valve replacement"],"prefix":"10.1007","volume":"65","author":[{"given":"Nashwa M.","family":"Abdulsalam","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeanne E.","family":"Poole","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elizabeth R.","family":"Lyden","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arthur J.","family":"Easley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gregory S.","family":"Pavlides","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shane F.","family":"Tsai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David E.","family":"Barton","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,9,2]]},"reference":[{"key":"1361_CR1","doi-asserted-by":"publisher","first-page":"1696","DOI":"10.1056\/NEJMoa1202277","volume":"366","author":"RR Makkar","year":"2012","unstructured":"Makkar RR, Fontana GP, Jilaihawi H, et al. Transcatheter aortic-valve replacement for inoperable severe aortic stenosis. N Engl J Med. 2012;366:1696\u2013704. https:\/\/doi.org\/10.1056\/NEJMoa1202277.","journal-title":"N Engl J Med"},{"key":"1361_CR2","doi-asserted-by":"publisher","first-page":"2187","DOI":"10.1056\/NEJMoa1103510","volume":"364","author":"CR Smith","year":"2011","unstructured":"Smith CR, Leon MB, Mack MJ, et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med. 2011;364:2187\u201398. https:\/\/doi.org\/10.1056\/NEJMoa1103510.","journal-title":"N Engl J Med"},{"key":"1361_CR3","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1056\/NEJMoa1700456","volume":"376","author":"MJ Reardon","year":"2017","unstructured":"Reardon MJ, Van Mieghem NM, Popma JJ, et al. Surgical or transcatheter aortic-valve replacement in intermediate-risk patients. N Engl J Med. 2017;376:1321\u201331. https:\/\/doi.org\/10.1056\/NEJMoa1700456.","journal-title":"N Engl J Med"},{"key":"1361_CR4","doi-asserted-by":"publisher","first-page":"1695","DOI":"10.1056\/NEJMoa1814052","volume":"380","author":"MJ Mack","year":"2019","unstructured":"Mack MJ, Leon MB, Thourani VH, et al. Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients. N Engl J Med. 2019;380:1695\u2013705. https:\/\/doi.org\/10.1056\/NEJMoa1814052.","journal-title":"N Engl J Med"},{"key":"1361_CR5","doi-asserted-by":"publisher","first-page":"1706","DOI":"10.1056\/NEJMoa1816885","volume":"380","author":"JJ Popma","year":"2019","unstructured":"Popma JJ, Deeb GM, Yakubov SJ, et al. Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients. N Engl J Med. 2019;380:1706\u201315. https:\/\/doi.org\/10.1056\/NEJMoa1816885.","journal-title":"N Engl J Med"},{"key":"1361_CR6","doi-asserted-by":"publisher","first-page":"2003","DOI":"10.1093\/eurheartj\/ehx785","volume":"39","author":"PJ van Rosendael","year":"2018","unstructured":"van Rosendael PJ, Delgado V, Bax JJ. Pacemaker implantation rate after transcatheter aortic valve implantation with early and new-generation devices: a systematic review. Eur Heart J. 2018;39:2003\u201313. https:\/\/doi.org\/10.1093\/eurheartj\/ehx785.","journal-title":"Eur Heart J"},{"issue":"1","key":"1361_CR7","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.jcin.2018.10.053","volume":"12","author":"TH Jorgensen","year":"2019","unstructured":"Jorgensen TH, De Backer O, Gerds TA, Bieliauskas G, Svendsen JH, Sondergaard L. Mortality and heart failure hospitalization in patients with conduction abnormalities after transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2019;12(1):52\u201361.","journal-title":"JACC Cardiovasc Interv"},{"key":"1361_CR8","doi-asserted-by":"publisher","first-page":"310","DOI":"10.1016\/j.jcin.2008.04.007","volume":"1","author":"N Piazza","year":"2008","unstructured":"Piazza N, Onuma Y, Jesserun E, et al. Early and persistent intraventricular conduction abnormalities and requirements for pacemaking after percutaneous replacement of the aortic valve. JACC Cardiovasc Interv. 2008;1:310\u20136. https:\/\/doi.org\/10.1016\/j.jcin.2008.04.007.","journal-title":"JACC Cardiovasc Interv"},{"key":"1361_CR9","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.1161\/CIRCULATIONAHA.117.028352","volume":"136","author":"V Auffret","year":"2017","unstructured":"Auffret V, Puri R, Urena M, et al. Conduction disturbances after transcatheter aortic valve replacement: current status and future perspectives. Circulation. 2017;136:1049\u201369. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.117.028352.","journal-title":"Circulation"},{"key":"1361_CR10","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1016\/j.jacc.2014.11.027","volume":"65","author":"M Urena","year":"2015","unstructured":"Urena M, Webb JG, Eltchaninoff H, et al. Late cardiac death in patients undergoing transcatheter aortic valve replacement: incidence and predictors of advanced heart failure and sudden cardiac death. J Am Coll Cardiol. 2015;65:437\u201348. https:\/\/doi.org\/10.1016\/j.jacc.2014.11.027.","journal-title":"J Am Coll Cardiol"},{"key":"1361_CR11","doi-asserted-by":"publisher","first-page":"1086","DOI":"10.1016\/j.jacc.2019.07.014","volume":"74","author":"J Rodes-Cabau","year":"2019","unstructured":"Rodes-Cabau J, Ellenbogen KA, Krahn AD, et al. Management of conduction disturbances associated with transcatheter aortic valve replacement: JACC Scientific Expert Panel. J Am Coll Cardiol. 2019;74:1086\u2013106.","journal-title":"J Am Coll Cardiol"},{"key":"1361_CR12","doi-asserted-by":"publisher","first-page":"e382","DOI":"10.1161\/CIR.0000000000000628","volume":"140","author":"FM Kusumoto","year":"2019","unstructured":"Kusumoto FM, Schoenfeld MH, Barrett C, et al. 2018 ACC\/AHA\/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay: a report of the American College of Cardiology\/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. Circulation. 2019;140:e382-482. https:\/\/doi.org\/10.1161\/CIR.0000000000000628.","journal-title":"Circulation"},{"issue":"3","key":"1361_CR13","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1016\/j.jcin.2007.12.009","volume":"1","author":"A Sinhal","year":"2008","unstructured":"Sinhal A, Altwegg L, Pasupati S, Humphries KH, Allard M, Martin P, et al. Atrioventricular block after transcatheter balloon expandable aortic valve implantation. JACC Cardiovasc Interv. 2008;1(3):305\u20139.","journal-title":"JACC Cardiovasc Interv"},{"issue":"5","key":"1361_CR14","doi-asserted-by":"publisher","first-page":"e29","DOI":"10.1161\/CIRCULATIONAHA.109.849281","volume":"120","author":"R Moreno","year":"2009","unstructured":"Moreno R, Dobarro D, Lopez de Sa E, Prieto M, Morales C, CalvoOrbe L, et al. Cause of complete atrioventricular block after percutaneous aortic valve implantation: insights from a necropsy study. Circulation. 2009;120(5):e29-30.","journal-title":"Circulation"},{"key":"1361_CR15","doi-asserted-by":"publisher","first-page":"1495","DOI":"10.1016\/j.jcin.2018.04.016","volume":"11","author":"J Rodes-Cabau","year":"2018","unstructured":"Rodes-Cabau J, Urena M, Nombela-Franco L, et al. Arrhythmic burden as determined by ambulatory continuous cardiac monitoring in patients with new-onset persistent left bundle branch block following transcatheter aortic valve replacement: the MARE Study. JACC Cardiovasc Interv. 2018;11:1495\u2013505.","journal-title":"JACC Cardiovasc Interv"},{"key":"1361_CR16","doi-asserted-by":"publisher","first-page":"1175","DOI":"10.1016\/j.jcin.2019.03.025","volume":"12","author":"C Chamandi","year":"2019","unstructured":"Chamandi C, Barbanti M, Munoz-Garcia A, et al. Long-term outcomes in patients with new-onset persistent left bundle branch block following TAVR. JACC Cardiovasc Interv. 2019;12:1175\u201384.","journal-title":"JACC Cardiovasc Interv"},{"issue":"1 Pt A","key":"1361_CR17","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.jcin.2014.07.022","volume":"8","author":"TM Nazif","year":"2015","unstructured":"Nazif TM, Dizon JM, Hahn RT, Xu K, Babaliaros V, Douglas PS, El-Chami MF, Herrmann HC, Mack M, Makkar RR, et al. Predictors and clinical outcomes of permanent pacemaker implantation after transcatheter aortic valve replacement: the PARTNER (placement of AoRtic TraNscathetER valves) trial and registry. JACC Cardiovasc Interv. 2015;8(1 Pt A):60\u20139.","journal-title":"JACC Cardiovasc Interv"},{"key":"1361_CR18","doi-asserted-by":"publisher","first-page":"1494","DOI":"10.4022\/jafib.1494","volume":"10","author":"AB Biviano","year":"2017","unstructured":"Biviano AB, Nazif T, Dizon J, et al. Atrial Fibrillation is Associated with Increased Pacemaker Implantation Rates in the Placement of AoRTic Transcatheter Valve (PARTNER) Trial. J Atr Fibrillation. 2017;10:1494. https:\/\/doi.org\/10.4022\/jafib.1494.","journal-title":"J Atr Fibrillation"},{"key":"1361_CR19","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1161\/01.CIR.64.2.215","volume":"64","author":"S Ohkawa","year":"1981","unstructured":"Ohkawa S, Sugiura M, Itoh Y, et al. Electrophysiologic and histologic correlations in chronic complete atrioventricular block. Circulation. 1981;64:215\u201331.","journal-title":"Circulation"},{"key":"1361_CR20","doi-asserted-by":"publisher","first-page":"1316","DOI":"10.1016\/0002-9149(82)90469-6","volume":"50","author":"MM Scheinman","year":"1982","unstructured":"Scheinman MM, Peters RW, Suave MJ, et al. Value of the H-Q interval in patients with bundle branch block and the role of prophylactic permanent pacing. Am J Cardiol. 1982;50:1316\u201322.","journal-title":"Am J Cardiol"},{"key":"1361_CR21","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1016\/j.hrthm.2014.10.023","volume":"12","author":"L Rivard","year":"2015","unstructured":"Rivard L, Schram G, Asgar A, et al. Electrocardiographic and electrophysiological predictors of atrioventricular block after transcatheter aortic valve replacement. Heart Rhythm. 2015;12:321\u20139. https:\/\/doi.org\/10.1016\/j.hrthm.2014.10.023.","journal-title":"Heart Rhythm"},{"key":"1361_CR22","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1093\/europace\/euv137","volume":"18","author":"A Kostopoulou","year":"2016","unstructured":"Kostopoulou A, Karyofillis P, Livanis E, et al. Permanent pacing after transcatheter aortic valve implantation of a CoreValve prosthesis as determined by electrocardiographic and electrophysiological predictors: a single-centre experience. Europace. 2016;18:131\u20137. https:\/\/doi.org\/10.1093\/europace\/euv137.","journal-title":"Europace"},{"key":"1361_CR23","doi-asserted-by":"publisher","first-page":"1269","DOI":"10.1016\/j.jcin.2016.03.024","volume":"9","author":"S Toggweiler","year":"2016","unstructured":"Toggweiler S, Stortecky S, Holy E, et al. The electrocardiogram after transcatheter aortic valve replacement determines the risk for post-procedural high-degree AV block and the need for telemetry monitoring. JACC Cardiovasc Interv. 2016;9:1269\u201376. https:\/\/doi.org\/10.1016\/j.jcin.2016.03.024.","journal-title":"JACC Cardiovasc Interv"},{"key":"1361_CR24","doi-asserted-by":"publisher","first-page":"1509","DOI":"10.1016\/j.jcin.2018.04.011","volume":"11","author":"TH Jorgensen","year":"2018","unstructured":"Jorgensen TH, De Backer O, Gerds TA, Bieliauskas G, Svendsen JH, Sondergaard L. Immediate post-procedural 12-lead electrocardiography as predictor of late conduction defects after transcatheter aortic valve replacemenT. JACC Cardiovasc Interv. 2018;11:1509\u201318.","journal-title":"JACC Cardiovasc Interv"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-022-01361-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-022-01361-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-022-01361-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,7]],"date-time":"2022-12-07T03:12:26Z","timestamp":1670382746000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-022-01361-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,2]]},"references-count":24,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["1361"],"URL":"https:\/\/doi.org\/10.1007\/s10840-022-01361-3","relation":{},"ISSN":["1383-875X","1572-8595"],"issn-type":[{"value":"1383-875X","type":"print"},{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,2]]},"assertion":[{"value":"21 June 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 August 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 September 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}