{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T23:17:48Z","timestamp":1767827868981,"version":"3.49.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2023,4,15]],"date-time":"2023-04-15T00:00:00Z","timestamp":1681516800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,4,15]],"date-time":"2023-04-15T00:00:00Z","timestamp":1681516800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"abstract":"<jats:title>Abstract\n<\/jats:title><jats:sec>\n                <jats:title>Background\n<\/jats:title>\n                <jats:p>Visually guided laser balloon (VGLB) ablation is a balloon-based treatment for atrial fibrillation (AF) that uses a titratable laser energy source to perform pulmonary vein isolation (PVI), allowing for real-time visualization of target tissue and ablation lesions through an endoscopic camera. Few long-term data on this technique are currently available. This report presents acute efficacy, procedural data, complication rates, and long-term AF-free survival up to 5\u00a0years post-ablation.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>In this single-center, retrospective, observational report, 152 patients (72.4% male, mean age 60.6\u2009\u00b1\u20099.7\u00a0years, 62.5% paroxysmal AF, 598 pulmonary veins in total) treated with the first-generation VGLB system between 2014 and 2016 were included for analysis. AF ablation consisted of PVI only.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Acute PVI was achieved in 98.2% of veins, with first-pass isolation in 92.5%. Procedure duration of 129\u00a0min [IQR 113\u2013150], fluoroscopy time of 15\u00a0min [IQR 11\u201320], and dose area product of 5016\u00a0mGy\u00b7cm<jats:sup>2<\/jats:sup> [IQR 3603\u20138711] were recorded. During a median follow-up of 51\u00a0months [IQR 45\u201357], 74.3% of patients remained free of AF (78.8% for paroxysmal and 65.3% for persistent AF, <jats:italic>p<\/jats:italic>\u2009=\u20090.108). Freedom of AF at 1, 2, 3, and 4\u00a0years follow-up was 88.2%, 82.2%, 78.9%, and 74.8%, respectively. PV reconnections were identified in only 46.9% of redo procedures. The median number of PV reconnections during redo procedures was 0 [IQR 0\u20132]. Anti-arrhythmic drug use was significantly reduced after ablation (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). The most commonly reported complications were minor vascular complications (4.6%) and transient phrenic nerve paralysis (3.3%).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>First-generation VGLB ablation demonstrated high acute isolation rates, reasonable procedure times and low complication rates. Long-term freedom from AF was 78.8% for paroxysmal AF and 65.3% for persistent AF, performing PVI only.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s10840-023-01544-6","type":"journal-article","created":{"date-parts":[[2023,4,15]],"date-time":"2023-04-15T02:02:07Z","timestamp":1681524127000},"page":"2081-2089","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Pulmonary vein isolation by visually guided laser balloon ablation: single-center 5-year follow-up results"],"prefix":"10.1007","volume":"66","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6373-180X","authenticated-orcid":false,"given":"Pieter","family":"Koopman","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thalia","family":"Bekelaar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joris","family":"Schurmans","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Phlips","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dagmara","family":"Dilling-Boer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johan","family":"Vijgen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,4,15]]},"reference":[{"issue":"1","key":"1544_CR1","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1093\/europace\/eux275","volume":"20","author":"H Calkins","year":"2018","unstructured":"Calkins H, Hindricks G, Cappato R, Kim YH, Saad EB, Aguinaga L, Akar JG, Badhwar V, Brugada J, Camm J, et al. 2017 HRS\/EHRA\/ECAS\/APHRS\/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: executive summary. EP Europace. 2018;20(1):157\u2013208. https:\/\/doi.org\/10.1093\/europace\/eux275.","journal-title":"EP Europace"},{"issue":"10","key":"1544_CR2","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1056\/NEJM199809033391003","volume":"339","author":"M Ha\u00efssaguerre","year":"1998","unstructured":"Ha\u00efssaguerre M, Ja\u00efs P, Shah DC, Takahashi A, Hocini M, Quiniou G, Garrigue S, Le Mouroux A, Le M\u00e9tayer P, Cl\u00e9menty J. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med. 1998;339(10):659\u201366. https:\/\/doi.org\/10.1056\/NEJM199809033391003.","journal-title":"N Engl J Med"},{"issue":"13","key":"1544_CR3","doi-asserted-by":"publisher","first-page":"1261","DOI":"10.1001\/jama.2019.0693","volume":"321","author":"DL Packer","year":"2019","unstructured":"Packer DL, Mark DB, Robb RA, Monahan KH, Bahnson TD, Poole JE, Noseworthy PA, Rosenberg YD, Jeffries N, Mitchell LB, et al. Effect of catheter ablation vs antiarrhythmic drug therapy on mortality, stroke, bleeding, and cardiac arrest among patients with atrial fibrillation: the CABANA randomized clinical trial. JAMA. 2019;321(13):1261\u201374. https:\/\/doi.org\/10.1001\/jama.2019.0693.","journal-title":"JAMA"},{"issue":"7","key":"1544_CR4","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1001\/jama.2014.467","volume":"311","author":"CA Morillo","year":"2014","unstructured":"Morillo CA, Verma A, Connolly SJ, Kuck KH, Nair GM, Champagne J, Sterns LD, Beresh H, Healey JS, Natale A. Radiofrequency ablation vs antiarrhythmic drugs as first-line treatment of paroxysmal atrial fibrillation (RAAFT-2): a randomized trial. JAMA. 2014;311(7):692\u2013700. https:\/\/doi.org\/10.1001\/jama.2014.467.","journal-title":"JAMA"},{"issue":"5","key":"1544_CR5","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1056\/NEJMoa1707855","volume":"378","author":"NF Marrouche","year":"2018","unstructured":"Marrouche NF, Brachmann J, Andresen D, Sibels J, Boersma L, Jordaens L, Merkely B, Pokushalov E, Sanders P, Proff J, et al. Catheter ablation for atrial fibrillation with heart failure. N Engl J Med. 2018;378(5):417\u201327. https:\/\/doi.org\/10.1056\/NEJMoa1707855.","journal-title":"N Engl J Med"},{"issue":"23","key":"1544_CR6","doi-asserted-by":"publisher","first-page":"2368","DOI":"10.1161\/CIRCULATIONAHA.110.946806","volume":"122","author":"F Ouyang","year":"2010","unstructured":"Ouyang F, Tilz R, Chun J, Schmidt B, Wissner E, Zerm T, Neven K, K\u00f6kt\u00fcrk B, Konstantinidou M, Metzner A, et al. Long-term results of catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up. Circulation. 2010;122(23):2368\u201377. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.110.946806.","journal-title":"Circulation"},{"issue":"7","key":"1544_CR7","doi-asserted-by":"publisher","first-page":"e005114","DOI":"10.1161\/CIRCEP.117.005114","volume":"10","author":"T Fink","year":"2017","unstructured":"Fink T, Schl\u00fcter M, Heeger CH, Lemes C, Maurer T, Reissmann B, Riedl J, Rottner L, Santoro F, Schmidt B, et al. Stand-alone pulmonary vein isolation versus pulmonary vein isolation with additional substrate modification as index ablation procedures in patients with persistent and long-standing persistent atrial fibrillation: the randomized alster-lost-AF trial (ablation at St. Georg Hospital for Long-Standing Persistent Atrial Fibrillation). Circ Arrhythm Electrophysiol. 2017;10(7):e005114. https:\/\/doi.org\/10.1161\/CIRCEP.117.005114.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"19","key":"1544_CR8","doi-asserted-by":"publisher","first-page":"1812","DOI":"10.1056\/NEJMoa1408288","volume":"372","author":"A Verma","year":"2015","unstructured":"Verma A, Jiang CY, Betts TR, Chen J, Deisenhofer I, Mantovan R, Macle L, Morillo CA, Haverkamp W, Weerasooriya R, et al. Approaches to catheter ablation for persistent atrial fibrillation. N Engl J Med. 2015;372(19):1812\u201322. https:\/\/doi.org\/10.1056\/NEJMoa1408288.","journal-title":"N Engl J Med"},{"issue":"6","key":"1544_CR9","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1111\/j.1540-8167.2011.02247.x","volume":"23","author":"B Schmidt","year":"2012","unstructured":"Schmidt B, Gunawardene M, Urban V, Kulikoglu M, Schulte-Hahn B, Nowak B, Bordignon S, Chun KJ. Visually guided sequential pulmonary vein isolation: insights into techniques and predictors of acute success. J Cardiovasc Electrophysiol. 2012;23(6):576\u201382. https:\/\/doi.org\/10.1111\/j.1540-8167.2011.02247.x.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"5","key":"1544_CR10","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1093\/europace\/eus352","volume":"15","author":"S Bordignon","year":"2013","unstructured":"Bordignon S, Chun KR, Gunawardene M, Urban V, Kulikoglu M, Miehm K, Brzank B, Schulte-Hahn B, Nowak B, Schmidt B. Energy titration strategies with the endoscopic ablation system: lessons from the high-dose vs. low-dose laser ablation study. Europace. 2013;15(5):685\u20139. https:\/\/doi.org\/10.1093\/europace\/eus352.","journal-title":"Europace"},{"issue":"3","key":"1544_CR11","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1161\/CIRCEP.113.000431","volume":"6","author":"SR Dukkipati","year":"2013","unstructured":"Dukkipati SR, Kuck KH, Neuzil P, Woollett I, Kautzner J, McElderry HT, Schmidt B, Gerstenfeld EP, Doshi SK, Horton R, et al. Pulmonary vein isolation using a visually guided laser balloon catheter: the first 200-patient multicenter clinical experience. Circ Arrhythm Electrophysiol. 2013;6(3):467\u201372. https:\/\/doi.org\/10.1161\/CIRCEP.113.000431.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"1","key":"1544_CR12","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1111\/j.1540-8167.2012.02427.x","volume":"24","author":"A Metzner","year":"2013","unstructured":"Metzner A, Wissner E, Schmidt B, Chun J, Hindrickx G, Piorkowski C, Ouyang F, Kuck KH. Acute and long-term clinical outcome after endoscopic pulmonary vein isolation: results from the first prospective, multicenter study. J Cardiovasc Electrophysiol. 2013;24(1):7\u201313. https:\/\/doi.org\/10.1111\/j.1540-8167.2012.02427.x.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"12","key":"1544_CR13","doi-asserted-by":"publisher","first-page":"1746","DOI":"10.1093\/europace\/euu168","volume":"16","author":"L \u0160ediv\u00e1","year":"2014","unstructured":"\u0160ediv\u00e1 L, Petr\u016f J, \u0160koda J, Janotka M, Chovanec M, Reddy V, Neu\u017eil P. Visually guided laser ablation: a single-centre long-term experience. Europace. 2014;16(12):1746\u201351. https:\/\/doi.org\/10.1093\/europace\/euu168.","journal-title":"Europace"},{"issue":"12","key":"1544_CR14","doi-asserted-by":"publisher","first-page":"1350","DOI":"10.1016\/j.jacc.2015.07.036","volume":"66","author":"SR Dukkipati","year":"2015","unstructured":"Dukkipati SR, Cuoco F, Kutinsky I, Aryana A, Bahnson TD, Lakkireddy D, Woollett I, Issa ZF, Natale A, Reddy VY. Pulmonary vein isolation using the visually guided laser balloon: a prospective, multicenter, and randomized comparison to standard radiofrequency ablation. J Am Coll Cardiol. 2015;66(12):1350\u201360. https:\/\/doi.org\/10.1016\/j.jacc.2015.07.036.","journal-title":"J Am Coll Cardiol"},{"issue":"12","key":"1544_CR15","doi-asserted-by":"publisher","first-page":"1293","DOI":"10.1111\/jce.12491","volume":"25","author":"L Perrotta","year":"2014","unstructured":"Perrotta L, Bordignon S, Dugo D, F\u00fcrnkranz A, Chun KJ, Schmidt B. How to learn pulmonary vein isolation with a novel ablation device: learning curve effects using the endoscopic ablation system. J Cardiovasc Electrophysiol. 2014;25(12):1293\u20138. https:\/\/doi.org\/10.1111\/jce.12491.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"4","key":"1544_CR16","doi-asserted-by":"publisher","first-page":"538","DOI":"10.1093\/europace\/euv208","volume":"18","author":"S Bordignon","year":"2016","unstructured":"Bordignon S, Boehmer MC, Klostermann A, Fuernkranz A, Perrotta L, Dugo D, Chun KR, Schmidt B. Visually guided pulmonary vein isolation in patients with persistent atrial fibrillation. Europace. 2016;18(4):538\u201342. https:\/\/doi.org\/10.1093\/europace\/euv208.","journal-title":"Europace"},{"issue":"12","key":"1544_CR17","doi-asserted-by":"publisher","first-page":"e005767","DOI":"10.1161\/CIRCEP.117.005767","volume":"10","author":"B Schmidt","year":"2017","unstructured":"Schmidt B, Neuzil P, Luik A, OscaAsensi J, Schrickel JW, Deneke T, Bordignon S, Petru J, Merkel M, Sediva L, et al. Laser balloon or wide-area circumferential irrigated radiofrequency ablation for persistent atrial fibrillation: a multicenter prospective randomized study. Circ Arrhythm Electrophysiol. 2017;10(12):e005767. https:\/\/doi.org\/10.1161\/CIRCEP.117.005767.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"9","key":"1544_CR18","doi-asserted-by":"publisher","first-page":"987","DOI":"10.1111\/jce.12192","volume":"24","author":"S Bordignon","year":"2013","unstructured":"Bordignon S, Chun KR, Gunawardene M, Fuernkranz A, Urban V, Schulte-Hahn B, Nowak B, Schmidt B. Comparison of balloon catheter ablation technologies for pulmonary vein isolation: the laser versus cryo study. J Cardiovasc Electrophysiol. 2013;24(9):987\u201394. https:\/\/doi.org\/10.1111\/jce.12192.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"3","key":"1544_CR19","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1007\/s10840-018-0474-4","volume":"54","author":"Y Wei","year":"2019","unstructured":"Wei Y, Zhang N, Jin Q, Pan W, Xie Y, Chen K, Ling T, Lin C, Bao Y, Luo Q, et al. Comparison of efficacy and safety of laser balloon and cryoballoon ablation for atrial fibrillation-a meta-analysis. J Interv Card Electrophysiol. 2019;54(3):237\u201345. https:\/\/doi.org\/10.1007\/s10840-018-0474-4.","journal-title":"J Interv Card Electrophysiol"},{"issue":"1","key":"1544_CR20","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1007\/s10840-020-00878-9","volume":"62","author":"X Zhou","year":"2021","unstructured":"Zhou X, Dai J, Xu X, Lian M, Lou Y, Lv Z, Wang Z, Mao W. Comparative efficacy and safety of catheter ablation interventions for atrial fibrillation: comprehensive network meta-analysis of randomized controlled trials. J Interv Card Electrophysiol. 2021;62(1):199\u2013211. https:\/\/doi.org\/10.1007\/s10840-020-00878-9.","journal-title":"J Interv Card Electrophysiol"},{"issue":"5","key":"1544_CR21","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1007\/s00392-017-1199-6","volume":"107","author":"B Reissmann","year":"2018","unstructured":"Reissmann B, Budelmann T, Wissner E, Schl\u00fcter M, Heeger CH, Mathew S, Maurer T, Lemes C, Fink T, Rillig A, et al. Five-year clinical outcomes of visually guided laser balloon pulmonary vein isolation for the treatment of paroxysmal atrial fibrillation. Clin Res Cardiol. 2018;107(5):405\u201312. https:\/\/doi.org\/10.1007\/s00392-017-1199-6.","journal-title":"Clin Res Cardiol"},{"issue":"5","key":"1544_CR22","doi-asserted-by":"publisher","first-page":"748","DOI":"10.1093\/europace\/euaa041","volume":"22","author":"J Dretzke","year":"2020","unstructured":"Dretzke J, Chuchu N, Agarwal R, Herd C, Chua W, Fabritz L, Bayliss S, Kotecha D, Deeks JJ, Kirchhof P, et al. Predicting recurrent atrial fibrillation after catheter ablation: a systematic review of prognostic models. Europace. 2020;22(5):748\u201360. https:\/\/doi.org\/10.1093\/europace\/euaa041.","journal-title":"Europace"},{"issue":"3","key":"1544_CR23","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1007\/s10840-016-0172-z","volume":"47","author":"A Aryana","year":"2016","unstructured":"Aryana A, Singh SM, Mugnai G, de Asmundis C, Kowalski M, Pujara DK, Cohen AI, Singh SK, Fuenzalida CE, Prager N, et al. Pulmonary vein reconnection following catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: results of a multicenter analysis. J Interv Card Electrophysiol. 2016;47(3):341\u20138. https:\/\/doi.org\/10.1007\/s10840-016-0172-z.","journal-title":"J Interv Card Electrophysiol"},{"key":"1544_CR24","doi-asserted-by":"publisher","first-page":"100576","DOI":"10.1016\/j.ijcha.2020.100576","volume":"29","author":"CH Heeger","year":"2020","unstructured":"Heeger CH, Tiemeyer CM, Phan HL, Meyer-Saraei R, Fink T, Sciacca V, Liosis S, Br\u00fcggemann B, Gro\u00dfe N, Fahimi B, et al. Rapid pulmonary vein isolation utilizing the third-generation laserballoon - the phoeniX registry. Int J Cardiol Heart Vasc. 2020;29:100576\u201381. https:\/\/doi.org\/10.1016\/j.ijcha.2020.100576.","journal-title":"Int J Cardiol Heart Vasc"},{"issue":"1","key":"1544_CR25","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1186\/s12872-017-0566-6","volume":"17","author":"A Luik","year":"2017","unstructured":"Luik A, Kunzmann K, H\u00f6rmann P, Schmidt K, Radzewitz A, Bramlage P, Schenk T, Schymik G, Merkel M, Kieser M, et al. Cryoballoon vs. open irrigated radiofrequency ablation for paroxysmal atrial fibrillation: long-term FreezeAF outcomes. BMC Cardiovasc Disord. 2017;17(1):135\u201342. https:\/\/doi.org\/10.1186\/s12872-017-0566-6.","journal-title":"BMC Cardiovasc Disord"},{"issue":"9","key":"1544_CR26","doi-asserted-by":"publisher","first-page":"984","DOI":"10.1111\/jce.13280","volume":"28","author":"GM Nair","year":"2017","unstructured":"Nair GM, Yeo C, MacDonald Z, Ainslie MP, Alqarawi WA, Nery PB, Redpath CJ, Sadek M, Spence S, Green MS, et al. Three-year outcomes and reconnection patterns after initial contact force guided pulmonary vein isolation for paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol. 2017;28(9):984\u201393. https:\/\/doi.org\/10.1111\/jce.13280.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"1544_CR27","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1016\/j.ijcard.2020.03.062","volume":"312","author":"CH Heeger","year":"2020","unstructured":"Heeger CH, Subin B, Wissner E, Fink T, Mathew S, Maurer T, Lemes C, Rillig A, Wohlmuth P, Reissmann B, et al. Second-generation cryoballoon-based pulmonary vein isolation: lessons from a five-year follow-up. Int J Cardiol. 2020;312:73\u201380. https:\/\/doi.org\/10.1016\/j.ijcard.2020.03.062.","journal-title":"Int J Cardiol"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-023-01544-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-023-01544-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-023-01544-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,4]],"date-time":"2023-12-04T03:04:19Z","timestamp":1701659059000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-023-01544-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,15]]},"references-count":27,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["1544"],"URL":"https:\/\/doi.org\/10.1007\/s10840-023-01544-6","relation":{},"ISSN":["1572-8595"],"issn-type":[{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,15]]},"assertion":[{"value":"31 July 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 April 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 April 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was performed in line with the principles of the Declaration of Helsinki. The study protocol was approved by the local ethics committee of Jessa Hospital, Hasselt, Belgium (study 20.80-cardio20.17).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Informed consent was obtained from all patients, agreeing to processing of patient characteristics and procedural data for scientific purposes.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"P. Koopman has received speaker and consultant honoraria from Cardiofocus and Medtronic. J Vijgen has received speaker and consultant honoraria from Cardiofocus. All other authors: none declared.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}