{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,23]],"date-time":"2026-03-23T18:15:38Z","timestamp":1774289738741,"version":"3.50.1"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2023,4,27]],"date-time":"2023-04-27T00:00:00Z","timestamp":1682553600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,4,27]],"date-time":"2023-04-27T00:00:00Z","timestamp":1682553600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"DOI":"10.1007\/s10840-023-01549-1","type":"journal-article","created":{"date-parts":[[2023,4,27]],"date-time":"2023-04-27T13:02:53Z","timestamp":1682600573000},"page":"273-283","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Posterior wall isolation via a multi-electrode radiofrequency balloon catheter: feasibility, technical considerations, endoscopic findings and comparison with cryoballoon technologies"],"prefix":"10.1007","volume":"67","author":[{"given":"Alvise","family":"Del Monte","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gian Battista","family":"Chierchia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3837-3462","authenticated-orcid":false,"given":"Domenico Giovanni","family":"Della Rocca","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luigi","family":"Pannone","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antonio","family":"Sorgente","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gezim","family":"Bala","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cinzia","family":"Monaco","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sahar","family":"Mouram","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lucio","family":"Capulzini Cremonini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charles","family":"Audiat","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joke","family":"Praet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robbert","family":"Ramak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ingrid","family":"Overeinder","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erwin","family":"Str\u00f6ker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juan","family":"Sieira","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark","family":"La Meir","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pedro","family":"Brugada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrea","family":"Sarkozy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlo","family":"de Asmundis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexandre","family":"Almorad","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,4,27]]},"reference":[{"key":"1549_CR1","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1056\/NEJMoa2029980","volume":"384","author":"JG Andrade","year":"2021","unstructured":"Andrade JG, Wells GA, Deyell MW, Bennett M, Essebag V, Champagne J, et al. Cryoablation or drug therapy for initial treatment of atrial fibrillation. N Engl J Med. 2021;384:305\u201315. https:\/\/doi.org\/10.1056\/NEJMoa2029980.","journal-title":"N Engl J Med"},{"key":"1549_CR2","doi-asserted-by":"publisher","first-page":"1261","DOI":"10.1001\/jama.2019.0693","volume":"321","author":"DL Packer","year":"2019","unstructured":"Packer DL, Mark DB, Robb RA, Monahan KH, Bahnson TD, Poole JE, et al. Effect of catheter ablation vs antiarrhythmic drug therapy on mortality, stroke, bleeding, and cardiac arrest among patients with atrial fibrillation: the CABANA randomized clinical trial. JAMA. 2019;321:1261. https:\/\/doi.org\/10.1001\/jama.2019.0693.","journal-title":"JAMA"},{"key":"1549_CR3","doi-asserted-by":"publisher","unstructured":"Della Rocca DG, Tarantino N, Trivedi C, Mohanty S, Anannab A, Salwan AS, et al. Non-pulmonary veintriggers in nonparoxysmal atrial fibrillation: Implications of pathophysiology for catheter ablation. J Cardiovasc Electrophysiol. 2020;31(8):2154\u201367. https:\/\/doi.org\/10.1111\/jce.14638.","DOI":"10.1111\/jce.14638"},{"key":"1549_CR4","doi-asserted-by":"publisher","unstructured":"Mohanty S, Trivedi C, Horton P, Della Rocca DG, Gianni C, MacDonald B, et al. Natural history of arrhythmia after successful isolation of pulmonary veins, left atrial posterior wall, and superior vena cava in patients with paroxysmal atrial fibrillation: a multi-center experience. J Am Heart Assoc. 2021;10(11):e020563.\u00a0https:\/\/doi.org\/10.1161\/JAHA.120.020563","DOI":"10.1161\/JAHA.120.020563"},{"key":"1549_CR5","doi-asserted-by":"publisher","first-page":"1939","DOI":"10.1093\/europace\/euab161","volume":"23","author":"DG Della Rocca","year":"2021","unstructured":"Della Rocca DG, Di Biase L, Mohanty S, Trivedi C, Gianni C, Romero J, et al. Targeting non-pulmonary vein triggers in persistent atrial fibrillation: results from a prospective, multicentre, observational registry. EP Eur. 2021;23:1939\u201349. https:\/\/doi.org\/10.1093\/europace\/euab161.","journal-title":"EP Eur"},{"key":"1549_CR6","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1248\/bpb.b212020","volume":"36","author":"I Namekata","year":"2013","unstructured":"Namekata I, Tsuneoka Y, Tanaka H. Electrophysiological and pharmacological properties of the pulmonary vein myocardium. Biol Pharm Bull. 2013;36:2\u20137. https:\/\/doi.org\/10.1248\/bpb.b212020.","journal-title":"Biol Pharm Bull"},{"key":"1549_CR7","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1007\/s10840-020-00885-w","volume":"62","author":"A Aryana","year":"2021","unstructured":"Aryana A, Pujara DK, Allen SL, Baker JH, Espinosa MA, Buch EF, et al. Left atrial posterior wall isolation in conjunction with pulmonary vein isolation using cryoballoon for treatment of persistent atrial fibrillation (PIVoTAL): study rationale and design. J Interv Card Electrophysiol. 2021;62:187\u201398. https:\/\/doi.org\/10.1007\/s10840-020-00885-w.","journal-title":"J Interv Card Electrophysiol"},{"key":"1549_CR8","doi-asserted-by":"publisher","first-page":"590","DOI":"10.1161\/CIRCEP.109.931634","volume":"3","author":"S Verheule","year":"2010","unstructured":"Verheule S, Tuyls E, van Hunnik A, Kuiper M, Schotten U, Allessie M. Fibrillatory conduction in the atrial free walls of goats in persistent and permanent atrial fibrillation. Circ Arrhythm Electrophysiol. 2010;3:590\u20139. https:\/\/doi.org\/10.1161\/CIRCEP.109.931634.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"1549_CR9","doi-asserted-by":"publisher","first-page":"2948","DOI":"10.3390\/jcm11102948","volume":"11","author":"L Pannone","year":"2022","unstructured":"Pannone L, Bisignani A, Sorgente A, Gauthey A, Della Rocca DG, Monaco C, et al. Atrial fibrillation global changes after pulmonary vein and posterior wall isolation: a charge density mapping study. J Clin Med. 2022;11:2948. https:\/\/doi.org\/10.3390\/jcm11102948.","journal-title":"J Clin Med"},{"key":"1549_CR10","doi-asserted-by":"publisher","first-page":"e010096","DOI":"10.1161\/CIRCEP.121.010096","volume":"14","author":"S Mohanty","year":"2021","unstructured":"Mohanty S, Trivedi C, Della Rocca DG, Gianni C, MacDonald B, Quintero Mayedo A, et al. Recovery of conduction following high-power short-duration ablation in patients with atrial fibrillation: a single-center experience. Circ Arrhythm Electrophysiol. 2021;14:e010096. https:\/\/doi.org\/10.1161\/CIRCEP.121.010096.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"1549_CR11","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1016\/j.ccep.2020.01.002","volume":"12","author":"DF Brice\u00f1o","year":"2020","unstructured":"Brice\u00f1o DF, Patel K, Romero J, Alviz I, Tarantino N, Della Rocca DG, et al. Beyond pulmonary vein isolation in nonparoxysmal atrial fibrillation. Card Electrophysiol Clin. 2020;12:219\u201331. https:\/\/doi.org\/10.1016\/j.ccep.2020.01.002.","journal-title":"Card Electrophysiol Clin"},{"key":"1549_CR12","doi-asserted-by":"publisher","first-page":"605","DOI":"10.1111\/pace.14495","volume":"45","author":"A Bisignani","year":"2022","unstructured":"Bisignani A, Pannone L, Miraglia V, Sieira J, Iacopino S, Bala G, et al. Feasibility and safety of left atrial posterior wall isolation with a new cryoballoon technology in patients with persistent atrial fibrillation. Pacing Clin Electrophysiol. 2022;45:605\u201311. https:\/\/doi.org\/10.1111\/pace.14495.","journal-title":"Pacing Clin Electrophysiol"},{"key":"1549_CR13","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1080\/17434440.2022.2096437","volume":"19","author":"V Miraglia","year":"2022","unstructured":"Miraglia V, Bisignani A, Pannone L, Iacopino S, Chierchia G-B, de Asmundis C. Cryoballoon ablation beyond pulmonary vein isolation in the setting of persistent atrial fibrillation. Expert Rev Med Devices. 2022;19:431\u20139. https:\/\/doi.org\/10.1080\/17434440.2022.2096437.","journal-title":"Expert Rev Med Devices"},{"key":"1549_CR14","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-021-01094-9","author":"A Almorad","year":"2021","unstructured":"Almorad A, Chierchia GB, Pannone L, Osorio TG, Sorgente A, Bisignani A, et al. The optimized clinical workflow for pulmonary vein isolation with the radiofrequency balloon. J Interv Card Electrophysiol. 2021. https:\/\/doi.org\/10.1007\/s10840-021-01094-9.","journal-title":"J Interv Card Electrophysiol"},{"key":"1549_CR15","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1016\/j.ccep.2019.05.009","volume":"11","author":"C Gianni","year":"2019","unstructured":"Gianni C, Chen Q, Della Rocca D, Canpolat U, Ayhan H, MacDonald B, et al. Radiofrequency Balloon Devices for Atrial Fibrillation Ablation. Card Electrophysiol Clin. 2019;11:487\u201393. https:\/\/doi.org\/10.1016\/j.ccep.2019.05.009.","journal-title":"Card Electrophysiol Clin"},{"key":"1549_CR16","doi-asserted-by":"publisher","first-page":"1259","DOI":"10.1111\/jce.14476","volume":"31","author":"GS Dhillon","year":"2020","unstructured":"Dhillon GS, Honarbakhsh S, Di Monaco A, Coling AE, Lenka K, Pizzamiglio F, et al. Use of a multi-electrode radiofrequency balloon catheter to achieve pulmonary vein isolation in patients with paroxysmal atrial fibrillation: 12-Month outcomes of the RADIANCE study. J Cardiovasc Electrophysiol. 2020;31:1259\u201369. https:\/\/doi.org\/10.1111\/jce.14476.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"1549_CR17","doi-asserted-by":"publisher","unstructured":"Del Monte A, Almorad A, Pannone L, Della Rocca DG, Bisignani A, Monaco C, et al. Pulmonary vein isolation with the radiofrequency balloon catheter: a single centre prospective study. EP Eur 2023:euad017. https:\/\/doi.org\/10.1093\/europace\/euad017.","DOI":"10.1093\/europace\/euad017"},{"key":"1549_CR18","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1093\/eurheartj\/ehaa612","volume":"42","author":"G Hindricks","year":"2021","unstructured":"Hindricks G, Potpara T, Dagres N, Arbelo E, Bax JJ, Blomstr\u00f6m-Lundqvist C, et al. 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J. 2021;42:373\u2013498. https:\/\/doi.org\/10.1093\/eurheartj\/ehaa612.","journal-title":"Eur Heart J"},{"key":"1549_CR19","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1016\/j.hrcr.2021.02.005","volume":"7","author":"A Aryana","year":"2021","unstructured":"Aryana A, Allen SL, Di Biase L, Bowers MR, O\u2019Neill PG, Natale A. Wide-area antral pulmonary vein and posterior wall isolation by way of segmental nonocclusive applications using a novel radiofrequency ablation balloon. Hear Case Rep. 2021;7:518\u201321. https:\/\/doi.org\/10.1016\/j.hrcr.2021.02.005.","journal-title":"Hear Case Rep"},{"key":"1549_CR20","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1161\/CIRCEP.107.748467","volume":"1","author":"SA Jones","year":"2008","unstructured":"Jones SA, Yamamoto M, Tellez JO, Billeter R, Boyett MR, Honjo H, et al. Distinguishing properties of cells from the myocardial sleeves of the pulmonary veins: a comparison of normal and abnormal pacemakers. Circ Arrhythm Electrophysiol. 2008;1:39\u201348. https:\/\/doi.org\/10.1161\/CIRCEP.107.748467.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"1549_CR21","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1038\/nature12358","volume":"500","author":"T Peng","year":"2013","unstructured":"Peng T, Tian Y, Boogerd CJ, Lu MM, Kadzik RS, Stewart KM, et al. Coordination of heart and lung co-development by a multipotent cardiopulmonary progenitor. Nature. 2013;500:589\u201392. https:\/\/doi.org\/10.1038\/nature12358.","journal-title":"Nature"},{"key":"1549_CR22","doi-asserted-by":"publisher","unstructured":"Pak H-N, Park J, Park J-W, Yang S-Y, Yu HT, Kim T-H, et al. Electrical posterior box isolation in persistent atrial fibrillation changed to paroxysmal atrial fibrillation: a multicenter, prospective, randomized study. Circ Arrhythm Electrophysiol 2020;13:e008531. https:\/\/doi.org\/10.1161\/CIRCEP.120.008531.","DOI":"10.1161\/CIRCEP.120.008531"},{"key":"1549_CR23","doi-asserted-by":"publisher","unstructured":"Thiyagarajah A, Kadhim K, Lau DH, Emami M, Linz D, Khokhar K, et al. Feasibility, safety, and efficacy of posterior wall isolation during atrial fibrillation ablation: a systematic review and meta-analysis. Circ Arrhythm Electrophysiol 2019;12:e007005. https:\/\/doi.org\/10.1161\/CIRCEP.118.007005.","DOI":"10.1161\/CIRCEP.118.007005"},{"key":"1549_CR24","doi-asserted-by":"publisher","first-page":"1740","DOI":"10.1016\/j.hrthm.2020.05.005","volume":"17","author":"TM Markman","year":"2020","unstructured":"Markman TM, Hyman MC, Kumareswaran R, Arkles JS, Santangeli P, Schaller RD, et al. Durability of posterior wall isolation after catheter ablation among patients with recurrent atrial fibrillation. Heart Rhythm. 2020;17:1740\u20134. https:\/\/doi.org\/10.1016\/j.hrthm.2020.05.005.","journal-title":"Heart Rhythm"},{"key":"1549_CR25","doi-asserted-by":"publisher","first-page":"2441","DOI":"10.1111\/jce.15168","volume":"32","author":"DG Della Rocca","year":"2021","unstructured":"Della Rocca DG, Magnocavallo M, Natale VN, Gianni C, Mohanty S, Trivedi C, et al. Clinical presentation, diagnosis, and treatment of atrioesophageal fistula resulting from atrial fibrillation ablation. J Cardiovasc Electrophysiol. 2021;32:2441\u201350. https:\/\/doi.org\/10.1111\/jce.15168.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"1549_CR26","doi-asserted-by":"publisher","first-page":"640","DOI":"10.1111\/pace.13938","volume":"43","author":"C Gianni","year":"2020","unstructured":"Gianni C, Della Rocca DG, MacDonald BC, Mohanty S, Quintero Mayedo A, SahoreSalwan A, et al. Prevention, diagnosis, and management of atrioesophageal fistula. Pacing Clin Electrophysiol. 2020;43:640\u20135. https:\/\/doi.org\/10.1111\/pace.13938.","journal-title":"Pacing Clin Electrophysiol"},{"key":"1549_CR27","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1007\/s10840-020-00887-8","volume":"62","author":"A Aryana","year":"2021","unstructured":"Aryana A, Di Biase L, Pujara DK, Baker JH, Espinosa MA, de Asmundis C, et al. Long-term durability of posterior wall isolation using the cryoballoon in patients with persistent atrial fibrillation: a multicenter analysis of repeat catheter ablations. J Interv Card Electrophysiol. 2021;62:161\u20139. https:\/\/doi.org\/10.1007\/s10840-020-00887-8.","journal-title":"J Interv Card Electrophysiol"},{"key":"1549_CR28","doi-asserted-by":"publisher","first-page":"1121","DOI":"10.1016\/j.hrthm.2018.05.014","volume":"15","author":"A Aryana","year":"2018","unstructured":"Aryana A, Baker JH, Espinosa Ginic MA, Pujara DK, Bowers MR, O\u2019Neill PG, et al. Posterior wall isolation using the cryoballoon in conjunction with pulmonary vein ablation is superior to pulmonary vein isolation alone in patients with persistent atrial fibrillation: A multicenter experience. Heart Rhythm. 2018;15:1121\u20139. https:\/\/doi.org\/10.1016\/j.hrthm.2018.05.014.","journal-title":"Heart Rhythm"},{"key":"1549_CR29","doi-asserted-by":"publisher","unstructured":"Lewalter T, Bitzen A, WURTZ, Ph.D. S, BLUM, Ph.D. R, SCHLODDER, Ph.D. K, Yang A, et al. Gold-tip electrodes\u2014a new \u201cdeep lesion\u201d technology for catheter ablation? In vitro comparison of a gold alloy versus platinum-iridium tip electrode ablation catheter. J Cardiovasc Electrophysiol 2005;16:770\u20132. https:\/\/doi.org\/10.1111\/j.1540-8167.2005.40832.x.","DOI":"10.1111\/j.1540-8167.2005.40832.x"},{"key":"1549_CR30","doi-asserted-by":"publisher","first-page":"717","DOI":"10.1111\/j.1540-8167.2011.02267.x","volume":"23","author":"M Linhart","year":"2012","unstructured":"Linhart M, Liberman I, Schrickel JW, Mittmann-Braun EL, Andri\u00e9 R, St\u00f6ckigt F, et al. Superiority of gold versus platinum irrigated tip catheter ablation of the pulmonary veins and the cavotricuspid isthmus: a randomized study comparing tip temperatures and cooling flow requirements. J Cardiovasc Electrophysiol. 2012;23:717\u201321. https:\/\/doi.org\/10.1111\/j.1540-8167.2011.02267.x.","journal-title":"J Cardiovasc Electrophysiol"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-023-01549-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-023-01549-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-023-01549-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,29]],"date-time":"2024-02-29T03:09:47Z","timestamp":1709176187000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-023-01549-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,27]]},"references-count":30,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2024,3]]}},"alternative-id":["1549"],"URL":"https:\/\/doi.org\/10.1007\/s10840-023-01549-1","relation":{},"ISSN":["1572-8595"],"issn-type":[{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,27]]},"assertion":[{"value":"2 March 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 April 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 April 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was performed in line with the principles of the Declaration of Helsinki. Approval was obtained by the Ethics Committee of the local institution.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Informed consent was obtained from all participants included in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Dr. Chierchia received compensation for teaching purposes and proctoring from Medtronic, Abbott, Biotronik, Boston Scientific and Acutus Medical. Dr. de Asmundis receives research grants on behalf of the centre from Biotronik, Medtronic, Abbott, LivaNova, Boston Scientific, AtriCure, Philips and Acutus and compensation for teaching purposes and proctoring from Medtronic, Abbott, Biotronik, Livanova, Boston Scientific, Atricure, Acutus Medical and Daiichi Sankyo. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}