{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T11:58:52Z","timestamp":1780919932662,"version":"3.54.1"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,6,27]],"date-time":"2023-06-27T00:00:00Z","timestamp":1687824000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,6,27]],"date-time":"2023-06-27T00:00:00Z","timestamp":1687824000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100003500","name":"Universit\u00e0 degli Studi di Padova","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100003500","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>The Medtronic SelectSecure Model 3830 lumenless lead (Medtronic, Inc., Minneapolis, MN) is commonly used for conduction system pacing (CSP). However, with this increased use, the potential need for transvenous lead extraction (TLE) also will increase. While extraction of endocardial 3830 leads is rather well described especially in pediatric and adult congenital heart disease population, there is very limited data on extraction of CSP leads. In the present study, we reported our preliminary experience on TLE of CSP leads and provided technical considerations.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The study population comprised 6 consecutive patients (67% male; mean age 70\u2009\u00b1\u200922\u00a0years) with CSP leads (3830 leads), including left bundle branch pacing (LBBP) lead (<jats:italic>n<\/jats:italic>\u2009=\u20093) and His pacing lead (<jats:italic>n<\/jats:italic>\u2009=\u20093) undergoing TLE. Overall target leads were 17. The mean implant duration time of CSP leads was 97\u2009\u00b1\u200990\u00a0months [range 8\u2013193).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Manual traction was successful in 2 cases and mechanical extraction tools were required in the remaining cases. Sixteen leads (94%) were completely extracted, whereas incomplete removal was observed in one lead (6%) among 1 patient. Of note, in the only lead incompletely removed, we observed retention of\u2009&lt;\u20091-cm remnant of lead material consisting of the screw of 3830 LBBP lead into the interventricular septum. No failure of lead extraction was reported and no major complications occurred.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Our findings demonstrated that at an experienced center the success of TLE of chronically implanted CSP leads is high in the absence of major complications also when mechanical extraction tools are needed.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s10840-023-01590-0","type":"journal-article","created":{"date-parts":[[2023,6,27]],"date-time":"2023-06-27T03:42:27Z","timestamp":1687837347000},"page":"175-182","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Transvenous lead extraction of lumenless 3830 pacing lead in conduction system pacing: a single-center experience"],"prefix":"10.1007","volume":"67","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8574-9421","authenticated-orcid":false,"given":"Federico","family":"Migliore","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raimondo","family":"Pittorru","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manuel","family":"De Lazzari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincenzo","family":"Tarzia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianni","family":"Pastore","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lina","family":"Marcantoni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Domenico","family":"Catanzariti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gino","family":"Gerosa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Zanon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,6,27]]},"reference":[{"key":"1590_CR1","doi-asserted-by":"publisher","first-page":"1208","DOI":"10.1093\/europace\/euad043","volume":"25","author":"H Burri","year":"2023","unstructured":"Burri H, Jastrzebski M, Cano \u00d3, et al. EHRA clinical consensus statement on conduction system pacing implantation: endorsed by the Asia Pacific Heart Rhythm Society (APHRS), Canadian Heart Rhythm Society (CHRS), and Latin American Heart Rhythm Society (LAHRS). Europace. 2023;25:1208\u201336.","journal-title":"Europace"},{"key":"1590_CR2","doi-asserted-by":"publisher","first-page":"927","DOI":"10.1016\/j.jacc.2018.06.017","volume":"72","author":"P Vijayaraman","year":"2018","unstructured":"Vijayaraman P, Chung MK, Dandamudi G, et al. His bundle pacing. J Am Coll Cardiol. 2018;72:927\u201347.","journal-title":"J Am Coll Cardiol"},{"key":"1590_CR3","first-page":"1397","volume":"4","author":"AG Bhatt","year":"2018","unstructured":"Bhatt AG, Musat DL, Milstein N, et al. The efficacy of His bundle pacing: lessons learned from implementation for the first time at an experienced electrophysiology center. J Am Coll Cardiol EP. 2018;4:1397\u2013406.","journal-title":"J Am Coll Cardiol EP"},{"key":"1590_CR4","doi-asserted-by":"publisher","first-page":"2462","DOI":"10.1111\/jce.14681","volume":"31","author":"SS Ponnusamy","year":"2020","unstructured":"Ponnusamy SS, Arora V, Namboodiri N, et al. J Cardiovasc Electrophysiol. 2020;31:2462\u201373.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"1590_CR5","doi-asserted-by":"publisher","first-page":"1431","DOI":"10.1016\/j.jacep.2022.08.001","volume":"8","author":"M Pujol-Lopez","year":"2022","unstructured":"Pujol-Lopez M, Jim\u00e9nez-Arjona R, Garre P, et al. Conduction system pacing vs biventricular pacing in heart failure and wide QRS patients: LEVEL-AT Trial. JACC Clin Electrophysiol. 2022;8:1431\u201345.","journal-title":"JACC Clin Electrophysiol"},{"issue":"23","key":"1590_CR6","first-page":"00209","volume":"S1547\u20135271","author":"PJ Vatterott","year":"2023","unstructured":"Vatterott PJ, Mond\u00e9sert B, Marshall M, et al. Mechanics of lumenless pacing lead strength during extraction procedures based on laboratory bench testing. Heart Rhythm. 2023;S1547\u20135271(23):00209\u201316.","journal-title":"Heart Rhythm"},{"key":"1590_CR7","doi-asserted-by":"publisher","first-page":"769","DOI":"10.1111\/jce.15828","volume":"34","author":"TD Richardson","year":"2023","unstructured":"Richardson TD, Himes A, Marshall M, et al. Rationale for and use of the lumenless 3830 pacing lead. J Cardiovasc Electrophysiol. 2023;34:769\u201374.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"1590_CR8","doi-asserted-by":"publisher","first-page":"993604","DOI":"10.3389\/fphys.2022.993604","volume":"13","author":"N Wijesuriya","year":"2022","unstructured":"Wijesuriya N, Elliott MK, Mehta V, et al. Transvenous lead extraction in conduction system pacing. Front Physiol. 2022;13:993604.","journal-title":"Front Physiol"},{"issue":"1","key":"1590_CR9","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1016\/j.hroo.2020.04.007","volume":"O2","author":"F Krainski","year":"2020","unstructured":"Krainski F, Miller JP, Pretorius V, et al. What goes in may need to come out: considerations in the extraction of a lumenless, fixed-screw permanent pacemaker lead. Heart Rhythm. 2020;O2(1):160\u20133.","journal-title":"Heart Rhythm"},{"key":"1590_CR10","doi-asserted-by":"publisher","first-page":"1227","DOI":"10.1016\/j.hrthm.2015.03.004","volume":"12","author":"E Shepherd","year":"2015","unstructured":"Shepherd E, Stuart G, Martin R, et al. Extraction of SelectSecure leads compared to conventional pacing leads in patients with congenital heart disease and congenital atrioventricular block. Heart Rhythm. 2015;12:1227\u201332.","journal-title":"Heart Rhythm"},{"key":"1590_CR11","doi-asserted-by":"publisher","first-page":"1196","DOI":"10.1016\/j.hrthm.2019.06.005","volume":"16","author":"P Vijayaraman","year":"2019","unstructured":"Vijayaraman P, Subzposh FA, Naperkowski A. Extraction of the permanent His bundle pacing lead: safety outcomes and feasibility of reimplantation. Heart Rhythm. 2019;16:1196\u2013203.","journal-title":"Heart Rhythm"},{"key":"1590_CR12","doi-asserted-by":"publisher","first-page":"903","DOI":"10.1016\/j.jacep.2020.04.005","volume":"6","author":"P Vijayaraman","year":"2020","unstructured":"Vijayaraman P. Extraction of left bundle branch pacing lead. JACC Clin Electrophysiol. 2020;6:903\u20134.","journal-title":"JACC Clin Electrophysiol"},{"key":"1590_CR13","doi-asserted-by":"publisher","first-page":"1464","DOI":"10.1111\/pace.14227","volume":"44","author":"F Migliore","year":"2021","unstructured":"Migliore F, Dall\u2019Aglio P, Falzone PV, et al. Extraction of a very old His bundle pacing lead: a safe and effective procedure? Pacing Clin Electrophysiol. 2021;44:1464\u20135.","journal-title":"Pacing Clin Electrophysiol"},{"key":"1590_CR14","doi-asserted-by":"publisher","first-page":"1921","DOI":"10.1093\/europace\/euab082","volume":"23","author":"F Migliore","year":"2021","unstructured":"Migliore F, Aruta P, Cecchetto A, et al. Extraction of left bundle branch pacing lead: a safe procedure? Europace. 2021;23:1921.","journal-title":"Europace"},{"issue":"6","key":"1590_CR15","doi-asserted-by":"publisher","first-page":"805","DOI":"10.5603\/CJ.2019.0120","volume":"26","author":"K Boczar","year":"2019","unstructured":"Boczar K, Z\u0105bek A, D\u0119bski M, et al. Transvenous extraction of His bundle pacing lead: new challenge in the field of lead extraction. Cardiol J. 2019;26(6):805.","journal-title":"Cardiol J"},{"key":"1590_CR16","doi-asserted-by":"publisher","first-page":"989","DOI":"10.1111\/pace.13700","volume":"42","author":"F Migliore","year":"2019","unstructured":"Migliore F, Testolina M, Sagone A, et al. Multicenter experience with the Evolution RL mechanical sheath for lead extraction using a stepwise approach: safety, effectiveness, and outcome. Pacing Clin Electrophysiol. 2019;42:989\u201397.","journal-title":"Pacing Clin Electrophysiol"},{"key":"1590_CR17","doi-asserted-by":"publisher","first-page":"1217","DOI":"10.1093\/europace\/euy050","volume":"20","author":"MG Bongiorni","year":"2018","unstructured":"Bongiorni MG, Burri H, Deharo JC, et al. 2018 EHRA expert consensus statement on lead extraction: recommendations on definitions, endpoints, research trial design, and data collection requirements for clinical scientific studies and registries. Europace. 2018;20:1217.","journal-title":"Europace"},{"key":"1590_CR18","doi-asserted-by":"publisher","first-page":"e503","DOI":"10.1016\/j.hrthm.2017.09.001","volume":"14","author":"FM Kusumoto","year":"2017","unstructured":"Kusumoto FM, Schoenfeld MH, Wilkoff BL, et al. 2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction. Heart Rhythm. 2017;14:e503\u201351.","journal-title":"Heart Rhythm"},{"key":"1590_CR19","doi-asserted-by":"publisher","first-page":"2346","DOI":"10.1111\/jce.15155","volume":"32","author":"SS Ponnusamy","year":"2021","unstructured":"Ponnusamy SS, Vijayaraman P. Late dislodgement of left bundle branch pacing lead and successful extraction. J Cardiovasc Electrophysiol. 2021;32:2346\u20139.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"1590_CR20","doi-asserted-by":"publisher","first-page":"645947","DOI":"10.3389\/fcvm.2021.645947","volume":"8","author":"X Chen","year":"2021","unstructured":"Chen X, Wei L, Bai J, et al. Procedure-related complications of left bundle branch pacing: a single-center experience. Front Cardiovasc Med. 2021;8:645947.","journal-title":"Front Cardiovasc Med"},{"key":"1590_CR21","doi-asserted-by":"publisher","first-page":"1464","DOI":"10.1111\/jce.15030","volume":"32","author":"JB le Polain de Waroux","year":"2021","unstructured":"le Polain de Waroux JB, Wielandts JY, Gillis K, et al. Repositioning and extraction of stylet-driven pacing leads with extendable helix used for left bundle branch area pacing. J Cardiovasc Electrophysiol. 2021;32:1464\u20136.","journal-title":"J Cardiovasc Electrophysiol."},{"key":"1590_CR22","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1007\/s10840-022-01325-7","volume":"66","author":"CA Agudo","year":"2023","unstructured":"Agudo CA, Ja\u00e9n EG, S\u00e1nchez DJ, et al. Extraction of a fractured pacemaker lead in the left bundle branch area using a snare via a femoral approach. J Interv Card Electrophysiol. 2023;66:239\u201340.","journal-title":"J Interv Card Electrophysiol"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-023-01590-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-023-01590-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-023-01590-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,5]],"date-time":"2024-01-05T07:29:50Z","timestamp":1704439790000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-023-01590-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,27]]},"references-count":22,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,1]]}},"alternative-id":["1590"],"URL":"https:\/\/doi.org\/10.1007\/s10840-023-01590-0","relation":{},"ISSN":["1572-8595"],"issn-type":[{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6,27]]},"assertion":[{"value":"3 May 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 June 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 June 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was carried out according to the Declaration of Helsinki guidelines and the deontological code of our institution. The study protocol was approved by the Ethical Committee of the hospital, and all patients provided informed consent.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Federico Migliore: Scientific Consulting Services for Cook Medical (USA). No other conflicts of interest to disclose.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}