{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,10,30]],"date-time":"2024-10-30T14:40:07Z","timestamp":1730299207090,"version":"3.28.0"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2024,4,17]],"date-time":"2024-04-17T00:00:00Z","timestamp":1713312000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,4,17]],"date-time":"2024-04-17T00:00:00Z","timestamp":1713312000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"DOI":"10.1007\/s10840-024-01776-0","type":"journal-article","created":{"date-parts":[[2024,4,17]],"date-time":"2024-04-17T08:51:22Z","timestamp":1713343882000},"page":"1571-1577","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Effect of adaptive cardiac resynchronization therapy in heart failure patients with pacemaker dependency"],"prefix":"10.1007","volume":"67","author":[{"given":"Toshihiro","family":"Nakamura","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kohei","family":"Ishibashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nobuhiko","family":"Ueda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoshi","family":"Oka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuichiro","family":"Miyazaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akinori","family":"Wakamiya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenzaburo","family":"Nakajima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tsukasa","family":"Kamakura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mitsuru","family":"Wada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuko","family":"Inoue","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koji","family":"Miyamoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoshi","family":"Nagase","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeshi","family":"Aiba","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kengo","family":"Kusano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,4,17]]},"reference":[{"key":"1776_CR1","doi-asserted-by":"publisher","first-page":"1692","DOI":"10.1253\/circj.CJ-66-0196","volume":"85","author":"A Nogami","year":"2021","unstructured":"Nogami A, Kurita T, Abe H, et al. Corrigendum: JCS\/JHRS 2019 Guideline on non-pharmacotherapy of cardiac arrhythmias. Circ J. 2021;85:1692\u2013700.","journal-title":"Circ J"},{"key":"1776_CR2","doi-asserted-by":"publisher","first-page":"1585","DOI":"10.1056\/NEJMoa1210356","volume":"368","author":"AB Curtis","year":"2013","unstructured":"Curtis AB, Worley SJ, Adamson PB, et al. Biventricular pacing for atrioventricular block and systolic dysfunction. N Engl J Med. 2013;368:1585\u201393.","journal-title":"N Engl J Med"},{"key":"1776_CR3","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1016\/j.ahj.2012.02.007","volume":"163","author":"H Krum","year":"2012","unstructured":"Krum H, Lemke B, Birnie D, et al. A novel algorithm for individualized cardiac resynchronization therapy: Rationale and design of the adaptive cardiac resynchronization therapy trial. Am Heart J. 2012;163:747\u2013752e1.","journal-title":"Am Heart J"},{"key":"1776_CR4","doi-asserted-by":"publisher","first-page":"2516","DOI":"10.1093\/eurheartj\/ehr329","volume":"32","author":"MR Gold","year":"2011","unstructured":"Gold MR, Birgersdotter-Green U, Singh JP, et al. The relationship between ventricular electrical delay and left ventricular remodelling with cardiac resynchronization therapy. Eur Heart J. 2011;32:2516\u201324.","journal-title":"Eur Heart J"},{"key":"1776_CR5","doi-asserted-by":"publisher","first-page":"e004346","DOI":"10.1161\/CIRCEP.116.004346","volume":"9","author":"NA Chatterjee","year":"2016","unstructured":"Chatterjee NA, Gold MR, Waggoner AD, et al. Longer left ventricular electric delay reduces mitral regurgitation after cardiac resynchronization therapy: mechanistic insights from the SMART-AV study (SmartDelay determined AV optimization: a comparison to other AV delay methods used in cardiac resynchronization therapy). Circ Arrhythm Electrophysiol. 2016;9:e004346.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"1776_CR6","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1111\/jce.14376","volume":"31","author":"JP Singh","year":"2020","unstructured":"Singh JP, Cha YM, Lunati M, et al. Real-world behavior of CRT pacing using the AdaptivCRT algorithm on patient outcomes: Effect on mortality and atrial fibrillation incidence. J Cardiovasc Electrophysiol. 2020;31:825\u201333.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"1776_CR7","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1016\/j.hrthm.2018.08.035","volume":"16","author":"D Yagishita","year":"2019","unstructured":"Yagishita D, Shoda M, Yagishita Y, Ejima K, Hagiwara N. Time interval from left ventricular stimulation to QRS onset is a novel predictor of nonresponse to cardiac resynchronization therapy. Heart Rhythm. 2019;16:395\u2013402.","journal-title":"Heart Rhythm"},{"key":"1776_CR8","doi-asserted-by":"publisher","first-page":"796","DOI":"10.1016\/j.jacep.2020.10.015","volume":"7","author":"D Yagishita","year":"2021","unstructured":"Yagishita D, Yagishita Y, Kataoka S, et al. Left ventricular stimulation with electrical latency predicts mortality in patients undergoing cardiac resynchronization therapy. JACC Clin Electrophysiol. 2021;7:796\u2013805.","journal-title":"JACC Clin Electrophysiol"},{"key":"1776_CR9","doi-asserted-by":"publisher","first-page":"1464","DOI":"10.1093\/europace\/eur146","volume":"13","author":"Y Khaykin","year":"2011","unstructured":"Khaykin Y, Exner D, Birnie D, Sapp J, Aggarwal S, Sambelashvili A. Adjusting the timing of left-ventricular pacing using electrocardiogram and device electrograms. Europace. 2011;13:1464\u201370.","journal-title":"Europace"},{"key":"1776_CR10","doi-asserted-by":"publisher","first-page":"2305","DOI":"10.1016\/j.jacc.2005.02.098","volume":"46","author":"BM van Gelder","year":"2005","unstructured":"van Gelder BM, Bracke FA, Meijer A, Pijls NH. The hemodynamic effect of intrinsic conduction during left ventricular pacing as compared to biventricular pacing. J Am Coll Cardiol. 2005;46:2305\u201310.","journal-title":"J Am Coll Cardiol"},{"key":"1776_CR11","doi-asserted-by":"publisher","first-page":"1226","DOI":"10.1111\/j.1540-8167.2010.01807.x","volume":"21","author":"RC Jones","year":"2010","unstructured":"Jones RC, Svinarich T, Rubin A, et al. Optimal atrioventricular delay in CRT patients can be approximated using surface electrocardiography and device electrograms. J Cardiovasc Electrophysiol. 2010;21:1226\u201332.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"1776_CR12","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1016\/j.echo.2008.01.003","volume":"21","author":"J Gorcsan","year":"2008","unstructured":"Gorcsan J 3rd, Abraham T, Agler DA, et al. Echocardiography for cardiac resynchronization therapy: recommendations for performance and reporting\u2013A report from the American Society of Echocardiography Dyssynchrony Writing Group endorsed by the Heart Rhythm Society. J Am Soc Echocardiogr. 2008;21:191\u2013213.","journal-title":"J Am Soc Echocardiogr"},{"key":"1776_CR13","doi-asserted-by":"publisher","first-page":"950","DOI":"10.1002\/ejhf.895","volume":"19","author":"G Filippatos","year":"2017","unstructured":"Filippatos G, Birnie D, Gold MR, et al. Rationale and design of the AdaptResponse trial: a prospective randomized study of cardiac resynchronization therapy with preferential adaptive left ventricular-only pacing. Eur J Heart Fail. 2017;19:950\u20137.","journal-title":"Eur J Heart Fail"},{"key":"1776_CR14","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1016\/j.jacc.2008.11.024","volume":"53","author":"W Mullens","year":"2009","unstructured":"Mullens W, Grimm RA, Verga T, et al. Insights from a cardiac resynchronization optimization clinic as part of a heart failure disease management program. J Am Coll Cardiol. 2009;53:765\u201373.","journal-title":"J Am Coll Cardiol"},{"key":"1776_CR15","doi-asserted-by":"publisher","first-page":"2993","DOI":"10.1161\/01.CIR.99.23.2993","volume":"99","author":"A Auricchio","year":"1999","unstructured":"Auricchio A, Stellbrink C, Block M, et al. Effect of pacing chamber and atrioventricular delay on acute systolic function of paced patients with congestive heart failure. The pacing therapies for congestive heart failure study group. The guidant congestive heart failure research group. Circulation. 1999;99:2993\u20133001.","journal-title":"Circulation"},{"key":"1776_CR16","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1111\/j.1540-8159.2005.40054.x","volume":"28","author":"C Scharf","year":"2005","unstructured":"Scharf C, Li P, Muntwyler J, et al. Rate-dependent AV delay optimization in cardiac resynchronization therapy. Pacing Clin Electrophysiol. 2005;28:279\u201384.","journal-title":"Pacing Clin Electrophysiol"},{"key":"1776_CR17","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1253\/circj.CJ-19-0691","volume":"84","author":"N Ueda","year":"2019","unstructured":"Ueda N, Noda T, Ishibashi K, et al. Efficacy of a device-based continuous optimization algorithm for patients with cardiac resynchronization therapy. Circ J. 2019;84:18\u201325.","journal-title":"Circ J"},{"key":"1776_CR18","doi-asserted-by":"publisher","first-page":"1807","DOI":"10.1016\/j.hrthm.2012.07.009","volume":"9","author":"DO Martin","year":"2012","unstructured":"Martin DO, Lemke B, Birnie D, et al. Investigation of a novel algorithm for synchronized left-ventricular pacing and ambulatory optimization of cardiac resynchronization therapy: results of the adaptive CRT trial. Heart Rhythm. 2012;9:1807\u201314.","journal-title":"Heart Rhythm"},{"key":"1776_CR19","doi-asserted-by":"publisher","first-page":"1368","DOI":"10.1016\/j.hrthm.2013.07.007","volume":"10","author":"D Birnie","year":"2013","unstructured":"Birnie D, Lemke B, Aonuma K, et al. Clinical outcomes with synchronized left ventricular pacing: analysis of the adaptive CRT trial. Heart Rhythm. 2013;10:1368\u201374.","journal-title":"Heart Rhythm"},{"key":"1776_CR20","doi-asserted-by":"publisher","first-page":"1820","DOI":"10.1016\/j.hrthm.2017.08.017","volume":"14","author":"D Birnie","year":"2017","unstructured":"Birnie D, Hudnall H, Lemke B, et al. Continuous optimization of cardiac resynchronization therapy reduces atrial fibrillation in heart failure patients: results of the adaptive Cardiac Resynchronization Therapy Trial. Heart Rhythm. 2017;14:1820\u20135.","journal-title":"Heart Rhythm"},{"key":"1776_CR21","doi-asserted-by":"publisher","first-page":"e17","DOI":"10.1016\/j.hrthm.2023.03.1538","volume":"20","author":"MK Chung","year":"2023","unstructured":"Chung MK, Patton KK, Lau CP, et al. 2023 HRS\/APHRS\/LAHRS guideline on cardiac physiologic pacing for the avoidance and mitigation of heart failure. Heart Rhythm. 2023;20:e17\u201391. S1547-5271(23)02026-X.","journal-title":"Heart Rhythm"},{"key":"1776_CR22","doi-asserted-by":"publisher","first-page":"1815","DOI":"10.1016\/j.hrthm.2012.07.001","volume":"9","author":"N Shanmugam","year":"2012","unstructured":"Shanmugam N, Prada-Delgado O, Campos AG, et al. Rate-adaptive AV delay and exercise performance following cardiac resynchronization therapy. Heart Rhythm. 2012;9:1815\u201321.","journal-title":"Heart Rhythm"},{"key":"1776_CR23","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1136\/heartjnl-2011-300278","volume":"98","author":"JP Sun","year":"2012","unstructured":"Sun JP, Lee AP, Grimm RA, et al. Optimisation of atrioventricular delay during exercise improves cardiac output in patients stabilised with cardiac resynchronisation therapy. Heart. 2012;98:54\u20139.","journal-title":"Heart"},{"key":"1776_CR24","doi-asserted-by":"publisher","first-page":"2002","DOI":"10.1253\/circj.CJ-19-0512","volume":"83","author":"A Kasagawa","year":"2019","unstructured":"Kasagawa A, Nakajima I, Izumo M, et al. Novel device-based algorithm provides optimal hemodynamics during exercise in patients with cardiac resynchronization therapy. Circ J. 2019;83:2002\u20139.","journal-title":"Circ J"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-024-01776-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-024-01776-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-024-01776-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,30]],"date-time":"2024-10-30T14:05:47Z","timestamp":1730297147000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-024-01776-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,17]]},"references-count":24,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2024,10]]}},"alternative-id":["1776"],"URL":"https:\/\/doi.org\/10.1007\/s10840-024-01776-0","relation":{},"ISSN":["1572-8595"],"issn-type":[{"type":"electronic","value":"1572-8595"}],"subject":[],"published":{"date-parts":[[2024,4,17]]},"assertion":[{"value":"20 November 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 February 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 April 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. The study was approved by the Institutional Research Board of the National Cerebral and Cardiovascular Center, Suita, Japan (M26-150\u201013).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"The patients consented to the use of their anonymized clinical data for research purposes by an opt-out method.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Dr. Kengo Kusano, Dr. Nobuhiko Ueda, and Dr. Kohei Ishibashi received remuneration for lectures from Medtronic Japan, Inc. Dr. Satoshi Nagase is affiliated with a department endowed by Japan Medtronic Inc. The other authors had no conflicts of interest to declare.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}