{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T14:40:02Z","timestamp":1756737602401,"version":"3.44.0"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2025,5,8]],"date-time":"2025-05-08T00:00:00Z","timestamp":1746662400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,5,8]],"date-time":"2025-05-08T00:00:00Z","timestamp":1746662400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100018998","name":"Ege University Research Foundation","doi-asserted-by":"publisher","award":["23677"],"award-info":[{"award-number":["23677"]}],"id":[{"id":"10.13039\/501100018998","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"DOI":"10.1007\/s10840-025-02060-5","type":"journal-article","created":{"date-parts":[[2025,5,8]],"date-time":"2025-05-08T03:44:19Z","timestamp":1746675859000},"page":"1295-1306","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of two suturing techniques in terms of lead stabilizing efficiency in acute and chronic terms"],"prefix":"10.1007","volume":"68","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-3084-368X","authenticated-orcid":false,"given":"Mustafa Talha","family":"Gunes","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7232-9660","authenticated-orcid":false,"given":"Soner","family":"Duman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6333-8856","authenticated-orcid":false,"given":"Derya","family":"Demir","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3183-8060","authenticated-orcid":false,"given":"Evrim","family":"Simsek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,5,8]]},"reference":[{"key":"2060_CR1","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1093\/EUROPACE\/EUV053","volume":"17","author":"KA Polyzos","year":"2015","unstructured":"Polyzos KA, Konstantelias AA, Falagas ME. Risk factors for cardiac implantable electronic device infection: a systematic review and meta-analysis. EP Europace. 2015;17:767\u201377. https:\/\/doi.org\/10.1093\/EUROPACE\/EUV053.","journal-title":"EP Europace"},{"issue":"2017","key":"2060_CR2","doi-asserted-by":"publisher","first-page":"e503","DOI":"10.1016\/J.HRTHM.2017.09.001","volume":"14","author":"FM Kusumoto","year":"2017","unstructured":"Kusumoto FM, Schoenfeld MH, Wilkoff BL, Berul CI, Birgersdotter-Green UM, Carrillo R, Cha YM, Clancy J, Deharo JC, Ellenbogen KA, Exner D, Hussein AA, Kennergren C, Krahn A, Lee R, Love CJ, Madden RA, Mazzetti HA, Moore JEC, Parsonnet J, Patton KK, Rozner MA, Selzman KA, Shoda M, Srivathsan K, Strathmore NF, Swerdlow CD, Tompkins C, Wazni O. HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction. Heart Rhythm. 2017;14(2017):e503\u201351. https:\/\/doi.org\/10.1016\/J.HRTHM.2017.09.001.","journal-title":"Heart Rhythm"},{"key":"2060_CR3","doi-asserted-by":"publisher","first-page":"1365","DOI":"10.1111\/PACE.13458","volume":"41","author":"Y Wang","year":"2018","unstructured":"Wang Y, Hou W, Zhou C, Yin Y, Lu S, Liu G, Duan C, Cao M, Li M, Toft ES, Zhang HJ. Meta-analysis of the incidence of lead dislodgement with conventional and leadless pacemaker systems. Pacing Clin Electrophysiol. 2018;41:1365\u201371. https:\/\/doi.org\/10.1111\/PACE.13458.","journal-title":"Pacing Clin Electrophysiol"},{"key":"2060_CR4","doi-asserted-by":"publisher","first-page":"1651","DOI":"10.1016\/J.JACC.2010.06.037","volume":"56","author":"A Cheng","year":"2010","unstructured":"Cheng A, Wang Y, Curtis JP, Varosy PD. Acute lead dislodgements and in-hospital mortality in patients enrolled in the national cardiovascular data registry implantable cardioverter defibrillator registry. J Am Coll Cardiol. 2010;56:1651\u20136. https:\/\/doi.org\/10.1016\/J.JACC.2010.06.037.","journal-title":"J Am Coll Cardiol"},{"key":"2060_CR5","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1161\/CIRCEP.122.011029","volume":"15","author":"D Qin","year":"2022","unstructured":"Qin D, Filippaios A, Murphy J, Berg M, Lampert R, Schloss EJ, Noone M, Mela T. Short- and long-term risk of lead dislodgement events: real-world experience from product surveillance registry. Circ Arrhythm Electrophysiol. 2022;15:530\u20138. https:\/\/doi.org\/10.1161\/CIRCEP.122.011029.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2060_CR6","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1016\/S0003-4975(10)66325-4","volume":"5","author":"W Stanford","year":"1968","unstructured":"Stanford W, Coyle FL, Dooley BN, Hood RH. Transvenous pacemaker failure: migration of catheter lead by patient manipulation. Ann Thorac Surg. 1968;5:162\u20134. https:\/\/doi.org\/10.1016\/S0003-4975(10)66325-4.","journal-title":"Ann Thorac Surg"},{"key":"2060_CR7","unstructured":"Bayliss CE, Beanlands DS, Baird RJ, Toronto J. Case reports: pacemaker complication 371 CASEREPOBTS The pacemaker-Twiddler\u2019s syndrome: a new complication of implantable transvenous pacemakers Sites in Pacing System Where. 1968."},{"key":"2060_CR8","doi-asserted-by":"publisher","first-page":"788","DOI":"10.1016\/J.HRTHM.2006.12.029","volume":"4","author":"NH Von Bergen","year":"2007","unstructured":"Von Bergen NH, Atkins DL, Gingerich JC, Law IH. \u201cRatchet\u201d syndrome, another etiology for pacemaker lead dislodgement: a case report. Heart Rhythm. 2007;4:788\u20139. https:\/\/doi.org\/10.1016\/J.HRTHM.2006.12.029.","journal-title":"Heart Rhythm"},{"key":"2060_CR9","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1016\/0002-8703(94)90286-0","volume":"128","author":"B Avitall","year":"1994","unstructured":"Avitall B, Stormo A, Barragry T, Axtel K, Hare J. Sudden cardiac death: Twiddler\u2019s syndrome with an implantable cardioverter defibrillator. Am Heart J. 1994;128:833\u20136. https:\/\/doi.org\/10.1016\/0002-8703(94)90286-0.","journal-title":"Am Heart J"},{"key":"2060_CR10","unstructured":"Demarco DC, Xuereb RG. \u201cTwiddling\u201d of the pacemaker resulting in lead dislodgement Case Report. 2009."},{"key":"2060_CR11","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1002\/ccr3.2682","volume":"8","author":"G Bazoukis","year":"2020","unstructured":"Bazoukis G, Kollias G, Tse G, Saplaouras A, Mililis P, Sakellaropoulou A, Kolokathis AM, Asvestas D, Efremidis M, Sideris A, Letsas KP. Reel syndrome\u2014an uncommon etiology of ICD dysfunction. Clin Case Rep. 2020;8:582\u20133. https:\/\/doi.org\/10.1002\/ccr3.2682.","journal-title":"Clin Case Rep"},{"key":"2060_CR12","doi-asserted-by":"publisher","first-page":"983","DOI":"10.1093\/EUROPACE\/EUAA367","volume":"23","author":"H Burri","year":"2021","unstructured":"Burri H, Starck C, Auricchio A, Biffi M, Burri M, D\u2019avila A, Deharo JC, Glikson M, Israel C, Lau CP, Leclercq C, Love CJ, Nielsen JC, Vernooy K, Dagres N, Boveda S, Butter C, Marijon E, Braunschweig F, Mairesse GH, Gleva M, Defaye P, Zanon F, Lopez-Cabanillas N, Guerra JM, Vassilikos VP, Oliveira MM. EHRA expert consensus statement and practical guide on optimal implantation technique for conventional pacemakers and implantable cardioverter-defibrillators: endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), and the Latin-American Heart Rhythm Society (LAHRS). EP Europace. 2021;23:983\u20131008. https:\/\/doi.org\/10.1093\/EUROPACE\/EUAA367.","journal-title":"EP Europace"},{"key":"2060_CR13","doi-asserted-by":"publisher","first-page":"E10","DOI":"10.1503\/CJS.002418","volume":"62","author":"S Rezazadeh","year":"2019","unstructured":"Rezazadeh S, Wang S, Rizkallah J. Evaluation of common suturing techniques to secure implantable cardiac electronic device leads: which strategy best reduces the lead dislodgement risk? Can J Surg. 2019;62:E10\u20133. https:\/\/doi.org\/10.1503\/CJS.002418.","journal-title":"Can J Surg"},{"key":"2060_CR14","doi-asserted-by":"publisher","first-page":"111","DOI":"10.4103\/1735-3327.92960","volume":"9","author":"M Mapara","year":"2011","unstructured":"Mapara M, Thomas BS, Bhat KM. Rabbit as an animal model for experimental research. Dent Res J (Isfahan). 2011;9:111\u20138. https:\/\/doi.org\/10.4103\/1735-3327.92960.","journal-title":"Dent Res J (Isfahan)"},{"key":"2060_CR15","volume-title":"Atlas of suturing techniques: approaches to surgical wound, laceration, and cosmetic repair","author":"J Kantor","year":"2016","unstructured":"Kantor J. Atlas of suturing techniques: approaches to surgical wound, laceration, and cosmetic repair. Second: McGraw-Hill; 2016."}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-025-02060-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-025-02060-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-025-02060-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T14:02:41Z","timestamp":1756735361000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-025-02060-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,8]]},"references-count":15,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2025,9]]}},"alternative-id":["2060"],"URL":"https:\/\/doi.org\/10.1007\/s10840-025-02060-5","relation":{},"ISSN":["1572-8595"],"issn-type":[{"type":"electronic","value":"1572-8595"}],"subject":[],"published":{"date-parts":[[2025,5,8]]},"assertion":[{"value":"24 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was conducted on animal models, and ARRIVE guidelines were followed thoroughly.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}