{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T04:09:26Z","timestamp":1792642166808,"version":"4.5.0"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T00:00:00Z","timestamp":1760572800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T00:00:00Z","timestamp":1760572800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"DOI":"10.1007\/s10840-025-02145-1","type":"journal-article","created":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T08:13:16Z","timestamp":1760602396000},"page":"1011-1023","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Microbubble and thermal profile of an eight-spline pulsed field ablation system in a pre-clinical model"],"prefix":"10.1007","volume":"69","author":[{"given":"Ben","family":"Niemiera","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ravi","family":"Ranjan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan P.","family":"Piccini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Nguyen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lakshya","family":"Mittal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Catherine","family":"Pipenhagen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jed","family":"Overmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taylor","family":"Spangler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sri","family":"Sundaram","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,10,16]]},"reference":[{"issue":"18","key":"2145_CR1","doi-asserted-by":"publisher","first-page":"1660","DOI":"10.1056\/NEJMoa2307291","volume":"389","author":"VY Reddy","year":"2023","unstructured":"Reddy VY, Gerstenfeld EP, Natale A, Whang W, Cuoco FA, Patel C, et al. Pulsed field or conventional thermal ablation for paroxysmal atrial fibrillation. N Engl J Med. 2023;389(18):1660\u201371.","journal-title":"N Engl J Med"},{"issue":"9","key":"2145_CR2","doi-asserted-by":"publisher","first-page":"1238","DOI":"10.1016\/j.hrthm.2023.05.018","volume":"20","author":"A Verma","year":"2023","unstructured":"Verma A, Haines DE, Boersma LV, Sood N, Natale A, Marchlinski FE, et al. Influence of monitoring and atrial arrhythmia burden on quality of life and health care utilization in patients undergoing pulsed field ablation: a secondary analysis of the PULSED AF trial. Heart Rhythm. 2023;20(9):1238\u201345.","journal-title":"Heart Rhythm"},{"issue":"8 Pt 3","key":"2145_CR3","first-page":"1786","volume":"9","author":"VY Reddy","year":"2023","unstructured":"Reddy VY, Peichl P, Anter E, Rackauskas G, Petru J, Funasako M, et al. A focal ablation catheter toggling between radiofrequency and pulsed field energy to treat atrial fibrillation. JACC: Clinical Electrophysiology. 2023;9(8 Pt 3):1786\u2013801.","journal-title":"JACC: Clinical Electrophysiology"},{"key":"2145_CR4","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euae118","author":"P Sanders","year":"2024","unstructured":"Sanders P, Healy S, Emami M, Kotschet E, Miller A, Kalman JM. Initial clinical experience with the balloon-in-basket pulsed field ablation system: acute results of the VOLT CE mark feasibility study. Europace. 2024. https:\/\/doi.org\/10.1093\/europace\/euae118.","journal-title":"Europace"},{"issue":"7","key":"2145_CR5","doi-asserted-by":"publisher","first-page":"2020","DOI":"10.1038\/s41591-024-03114-3","volume":"30","author":"E Ekanem","year":"2024","unstructured":"Ekanem E, Neuzil P, Reichlin T, Kautzner J, van der Voort P, Jais P, et al. Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K study. Nat Med. 2024;30(7):2020\u20139.","journal-title":"Nat Med"},{"issue":"9","key":"2145_CR6","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1016\/j.hroo.2024.08.002","volume":"5","author":"A Sugrue","year":"2024","unstructured":"Sugrue A, Shabtaie S, Tan NY, Maor E, Kapa S, Asirvatham SJ. Considerations regarding safety with pulsed field ablation for atrial fibrillation. Heart Rhythm O2. 2024;5(9):655\u201361.","journal-title":"Heart Rhythm O2"},{"issue":"5","key":"2145_CR7","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1016\/j.jacep.2021.02.014","volume":"7","author":"VY Reddy","year":"2021","unstructured":"Reddy VY, Dukkipati SR, Neuzil P, Anic A, Petru J, Funasako M, et al. Pulsed field ablation of paroxysmal atrial fibrillation: 1-year outcomes of IMPULSE, PEFCAT, and PEFCAT II. JACC Clin Electrophysiol. 2021;7(5):614\u201327.","journal-title":"JACC Clin Electrophysiol"},{"key":"2145_CR8","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euad185","author":"B Schmidt","year":"2023","unstructured":"Schmidt B, Bordignon S, Neven K, Reichlin T, Blaauw Y, Hansen J, et al. European real-world outcomes with pulsed field ablation in patients with symptomatic atrial fibrillation: lessons from the multi-centre EU-PORIA registry. Europace. 2023. https:\/\/doi.org\/10.1093\/europace\/euad185.","journal-title":"Europace"},{"key":"2145_CR9","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2024.132522","volume":"417","author":"R Mene","year":"2024","unstructured":"Mene R, Sousonis V, Schmidt B, Bordignon S, Neven K, Reichlin T, et al. Safety and efficacy of pulsed-field ablation for atrial fibrillation in the elderly: a EU-PORIA sub-analysis. Int J Cardiol. 2024;417:132522.","journal-title":"Int J Cardiol"},{"key":"2145_CR10","unstructured":"Turagam MK, Neuzil P, Schmidt B, Reichlin T, Neven K, Metzner A, et al. Safety and effectiveness of pulsed field ablation for atrial fibrillation in patients with heart failure: A MANIFEST-PF Sub-analysis. JACC Clin Electrophysiol. 2024."},{"key":"2145_CR11","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2024.05.002","author":"MK Turagam","year":"2024","unstructured":"Turagam MK, Neuzil P, Schmidt B, Reichlin T, Neven K, Metzner A, et al. Safety and effectiveness of pulsed field ablation for atrial fibrillation in patients with heart failure. JACC: Clinical Electrophysiology. 2024. https:\/\/doi.org\/10.1016\/j.jacep.2024.05.002.","journal-title":"JACC: Clinical Electrophysiology"},{"issue":"5","key":"2145_CR12","first-page":"900","volume":"10","author":"MK Turagam","year":"2024","unstructured":"Turagam MK, Neuzil P, Schmidt B, Reichlin T, Neven K, Metzner A, et al. Impact of left atrial posterior wall ablation during pulsed-field ablation for persistent atrial fibrillation. JACC: Clinical Electrophysiology. 2024;10(5):900\u201312.","journal-title":"JACC: Clinical Electrophysiology"},{"issue":"1","key":"2145_CR13","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1007\/s11886-010-0153-2","volume":"13","author":"JF Viles-Gonzalez","year":"2011","unstructured":"Viles-Gonzalez JF, Mehta D. Thromboembolic risk and anticoagulation strategies in patients undergoing catheter ablation for atrial fibrillation. Curr Cardiol Rep. 2011;13(1):38\u201342.","journal-title":"Curr Cardiol Rep"},{"issue":"1","key":"2145_CR14","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1016\/j.hrthm.2006.10.034","volume":"4","author":"S Dixit","year":"2007","unstructured":"Dixit S, Marchlinski FE. How to recognize, manage, and prevent complications during atrial fibrillation ablation. Heart Rhythm. 2007;4(1):108\u201315.","journal-title":"Heart Rhythm"},{"issue":"9","key":"2145_CR15","doi-asserted-by":"publisher","first-page":"1854","DOI":"10.1016\/j.jacep.2023.05.005","volume":"9","author":"A Verma","year":"2023","unstructured":"Verma A, Zhong P, Castellvi Q, Girouard S, Mediratta V, Neal RE 2nd. Thermal profiles for focal pulsed electric field ablation. JACC Clin Electrophysiol. 2023;9(9):1854\u201363.","journal-title":"JACC Clin Electrophysiol"},{"issue":"7","key":"2145_CR16","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1016\/j.jacc.2011.04.010","volume":"58","author":"C Herrera Siklody","year":"2011","unstructured":"Herrera Siklody C, Deneke T, Hocini M, Lehrmann H, Shin DI, Miyazaki S, et al. Incidence of asymptomatic intracranial embolic events after pulmonary vein isolation: comparison of different atrial fibrillation ablation technologies in a multicenter study. J Am Coll Cardiol. 2011;58(7):681\u20138.","journal-title":"J Am Coll Cardiol"},{"issue":"9","key":"2145_CR17","doi-asserted-by":"publisher","first-page":"961","DOI":"10.1111\/j.1540-8167.2011.02050.x","volume":"22","author":"F Gaita","year":"2011","unstructured":"Gaita F, Leclercq JF, Schumacher B, Scaglione M, Toso E, Halimi F, et al. Incidence of silent cerebral thromboembolic lesions after atrial fibrillation ablation may change according to technology used: comparison of irrigated radiofrequency, multipolar nonirrigated catheter and cryoballoon. J Cardiovasc Electrophysiol. 2011;22(9):961\u20138.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"10","key":"2145_CR18","doi-asserted-by":"publisher","first-page":"1378","DOI":"10.1111\/pace.12432","volume":"37","author":"L Guijian","year":"2014","unstructured":"Guijian L, Wenqing Z, Xinggang W, Ying Y, Minghui L, Yeqing X, et al. Association between ablation technology and asymptomatic cerebral injury following atrial fibrillation ablation. Pacing Clin Electrophysiol. 2014;37(10):1378\u201391.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"1","key":"2145_CR19","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1093\/europace\/euv046","volume":"18","author":"K Wasmer","year":"2016","unstructured":"Wasmer K, Foraita P, Leitz P, Guner F, Pott C, Lange PS, et al. Safety profile of multielectrode-phased radiofrequency pulmonary vein ablation catheter and irrigated radiofrequency catheter. Europace. 2016;18(1):78\u201384.","journal-title":"Europace"},{"issue":"3","key":"2145_CR20","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1016\/j.hrthm.2022.11.013","volume":"20","author":"F Guo","year":"2023","unstructured":"Guo F, Wang J, Deng Q, Feng H, Xie M, Zhou Z, et al. Effects of pulsed field ablation on autonomic nervous system in paroxysmal atrial fibrillation: a pilot study. Heart Rhythm. 2023;20(3):329\u201338.","journal-title":"Heart Rhythm"},{"issue":"11","key":"2145_CR21","doi-asserted-by":"publisher","first-page":"1813","DOI":"10.1016\/j.hrthm.2022.06.018","volume":"19","author":"N Reinsch","year":"2022","unstructured":"Reinsch N, Futing A, Howel D, Bell J, Lin Y, Neven K. Cerebral safety after pulsed field ablation for paroxysmal atrial fibrillation. Heart Rhythm. 2022;19(11):1813\u20138.","journal-title":"Heart Rhythm"},{"issue":"3","key":"2145_CR22","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1161\/01.CIR.73.3.525","volume":"73","author":"GH Bardy","year":"1986","unstructured":"Bardy GH, Coltorti F, Ivey TD, Alferness C, Rackson M, Hansen K, et al. Some factors affecting bubble formation with catheter-mediated defibrillator pulses. Circulation. 1986;73(3):525\u201338.","journal-title":"Circulation"},{"key":"2145_CR23","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euae118","author":"P Sanders","year":"2024","unstructured":"Sanders P, Healy S, Emami M, Kotschet E, Miller A, Kalman JM. Initial clinical experience with the balloon-in-basket pulsed field ablation system: acute results of the VOLT CE mark feasibility study. Europace. 2024. https:\/\/doi.org\/10.1093\/europace\/euae118.","journal-title":"Europace"},{"issue":"1","key":"2145_CR24","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1093\/europace\/euaa243","volume":"23","author":"MHA Groen","year":"2021","unstructured":"Groen MHA, van Es R, van Klarenbosch BR, Stehouwer M, Loh P, Doevendans PA, et al. In vivo analysis of the origin and characteristics of gaseous microemboli during catheter-mediated irreversible electroporation. EP Europace. 2021;23(1):139\u201346.","journal-title":"EP Europace"},{"issue":"3","key":"2145_CR25","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1177\/0192623319826063","volume":"47","author":"WC Stoffregen","year":"2019","unstructured":"Stoffregen WC, Rousselle SD, Rippy MK. Pathology approaches to determine safety and efficacy of cardiac ablation catheters. Toxicol Pathol. 2019;47(3):311\u201328.","journal-title":"Toxicol Pathol"},{"issue":"1","key":"2145_CR26","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1161\/CIRCEP.111.973453","volume":"6","author":"DE Haines","year":"2013","unstructured":"Haines DE, Stewart MT, Dahlberg S, Barka ND, Condie C, Fiedler GR, et al. Microembolism and catheter ablation I: a comparison of irrigated radiofrequency and multielectrode-phased radiofrequency catheter ablation of pulmonary vein ostia. Circ Arrhythm Electrophysiol. 2013;6(1):16\u201322.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"1","key":"2145_CR27","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.115.003226","volume":"9","author":"M Takami","year":"2016","unstructured":"Takami M, Lehmann HI, Parker KD, Welker KM, Johnson SB, Packer DL. Effect of left atrial ablation process and strategy on microemboli formation during irrigated radiofrequency catheter ablation in an in vivo model. Circ Arrhythm Electrophysiol. 2016;9(1):e003226.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2145_CR28","doi-asserted-by":"crossref","unstructured":"Garcia PA, Neal RE, Sano MB, Robertson JL, Davalos RV, editors. An experimental investigation of temperature changes during electroporation. 2011 XXXth URSI General Assembly and Scientific Symposium; 2011 13\u201320 Aug. 2011.","DOI":"10.1109\/URSIGASS.2011.6051310"},{"issue":"3","key":"2145_CR29","doi-asserted-by":"publisher","DOI":"10.1115\/1.4053199","volume":"144","author":"KN Aycock","year":"2022","unstructured":"Aycock KN, Campelo SN, Davalos RV. A comparative modeling study of thermal mitigation strategies in irreversible electroporation treatments. J Heat Transfer. 2022;144(3):031206.","journal-title":"J Heat Transfer"},{"issue":"1","key":"2145_CR30","doi-asserted-by":"publisher","first-page":"16144","DOI":"10.1038\/s41598-022-20212-9","volume":"12","author":"M G\u00f3mez-Barea","year":"2022","unstructured":"G\u00f3mez-Barea M, Garc\u00eda-S\u00e1nchez T, Ivorra A. A computational comparison of radiofrequency and pulsed field ablation in terms of lesion morphology in the cardiac chamber. Sci Rep. 2022;12(1):16144.","journal-title":"Sci Rep"},{"key":"2145_CR31","first-page":"3","volume":"4","author":"IA Chang","year":"2010","unstructured":"Chang IA. Considerations for thermal injury analysis for RF ablation devices. Open Biomed Eng J. 2010;4:3\u201312.","journal-title":"Open Biomed Eng J"},{"issue":"10","key":"2145_CR32","doi-asserted-by":"publisher","first-page":"2071","DOI":"10.1111\/jce.14091","volume":"30","author":"R van Es","year":"2019","unstructured":"van Es R, Groen MHA, Stehouwer M, Doevendans PA, Wittkampf FHM, Neven K. In vitro analysis of the origin and characteristics of gaseous microemboli during catheter electroporation ablation. J Cardiovasc Electrophysiol. 2019;30(10):2071\u20139.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2145_CR33","doi-asserted-by":"publisher","DOI":"10.1016\/j.electacta.2024.144550","author":"S Mahni\u010d-Kalamiza","year":"2024","unstructured":"Mahni\u010d-Kalamiza S, Miklav\u010di\u010d D, Lombergar P, Miku\u017e B, Mattison LM, Sigg DC, et al. Elucidating the mechanisms of microbubble formation in intracardiac pulsed field ablation. Electrochim Acta. 2024. https:\/\/doi.org\/10.1016\/j.electacta.2024.144550.","journal-title":"Electrochim Acta"},{"key":"2145_CR34","doi-asserted-by":"crossref","unstructured":"Alkukhun L, Sandhu U, Hodovan J, Zhao Y, Chiang K, Castellvi Q, et al. Multi-modality imaging assessment of microbubbles and cerebral emboli in left ventricular pulsed field ablation. J Interv Card Electrophysiol. 2023.","DOI":"10.1007\/s10840-023-01529-5"},{"key":"2145_CR35","doi-asserted-by":"crossref","unstructured":"Mahnic-Kalamiza S MD, Lombergar P, Mikuz B, Mattison LM, Sigg D, Kos B. Elucidating the mechanisms of microbubble formation in intracardiac pulsed field ablation. Electrochimica Acta. 2204;497:1\u201312.","DOI":"10.1016\/j.electacta.2024.144550"},{"key":"2145_CR36","doi-asserted-by":"crossref","unstructured":"Neven K, Futing A, Byrd I, Heil RW Jr, Fish JM, Feeney DA, et al. Absence of (sub-)acute cerebral events or lesions after electroporation ablation in the left-sided canine heart. Heart Rhythm. 2021;18(6):1004\u201311.","DOI":"10.1016\/j.hrthm.2021.02.015"},{"issue":"6Part A","key":"2145_CR37","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1016\/j.hroo.2021.10.004","volume":"2","author":"A Belalcazar","year":"2021","unstructured":"Belalcazar A. Safety and efficacy aspects of pulsed field ablation catheters as a function of electrode proximity to blood and energy delivery method. Heart Rhythm 02. 2021;2(6Part A):560\u20139.","journal-title":"Heart Rhythm 02."},{"issue":"19","key":"2145_CR38","doi-asserted-by":"publisher","first-page":"1422","DOI":"10.1161\/CIRCULATIONAHA.123.063988","volume":"147","author":"A Verma","year":"2023","unstructured":"Verma A, Haines DE, Boersma LV, Sood N, Natale A, Marchlinski FE, et al. Pulsed field ablation for the treatment of atrial fibrillation: PULSED AF pivotal trial. Circulation. 2023;147(19):1422\u201332.","journal-title":"Circulation"},{"issue":"5","key":"2145_CR39","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1016\/j.ejcts.2009.05.004","volume":"36","author":"LD Sauren","year":"2009","unstructured":"Sauren LD, la Meir M, de Roy L, Pison L, van der Veen FH, Mess WH, et al. Increased number of cerebral emboli during percutaneous endocardial pulmonary vein isolation versus a thoracoscopic epicardial approach. Eur J Cardiothorac Surg. 2009;36(5):833\u20137.","journal-title":"Eur J Cardiothorac Surg"},{"issue":"3","key":"2145_CR40","doi-asserted-by":"publisher","first-page":"234","DOI":"10.5603\/CJ.a2017.0030","volume":"24","author":"E Nagy-Balo","year":"2017","unstructured":"Nagy-Balo E, Martirosyan M, Sandorfi G, Hajas O, Lanczi L, Berenyi E, et al. Cerebral micro-embolization during pulmonary vein isolation: relation to post-ablation silent cerebral ischemia. Cardiol J. 2017;24(3):234\u201341.","journal-title":"Cardiol J"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-025-02145-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-025-02145-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-025-02145-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T05:10:37Z","timestamp":1789621837000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-025-02145-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,16]]},"references-count":40,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2026,8]]}},"alternative-id":["2145"],"URL":"https:\/\/doi.org\/10.1007\/s10840-025-02145-1","relation":{},"ISSN":["1572-8595"],"issn-type":[{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,16]]},"assertion":[{"value":"18 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 September 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 October 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"BN, LM, CP, and JO are employees of Abbott.JPP receives grants for clinical research from Abbott, the American Heart Association, iRhythm, and Philips and serves as a consultant to Abbott, Medtronic, Milestone Pharmaceuticals, Novartis, Philips, PhysCade, Sanofi, SymKardia, and Up-to-Date. He serves on data safety and monitoring boards for Kardium and Conformal.JN serves as a consultant to Abbott.RR is a consultant to Abbott and Biosense Webster and has research grants from NIH, VA (MERIT-CSRD) and Biosense Webster.SS is a consultant to Abbott, Medtronic, and Boston Scientific. He is an equity interest holder and advisory board member for Heart Hearo.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}