{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T16:40:36Z","timestamp":1792082436174,"version":"4.4.0"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T00:00:00Z","timestamp":1762992000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T00:00:00Z","timestamp":1762992000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"DOI":"10.1007\/s10840-025-02159-9","type":"journal-article","created":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T07:49:18Z","timestamp":1763020158000},"page":"411-418","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Comparison of transjugular and transfemoral approaches for leadless pacemaker implantation in Asian patients: an exploratory study"],"prefix":"10.1007","volume":"69","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-3992-0128","authenticated-orcid":false,"given":"Seongjin","family":"Park","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7210-6109","authenticated-orcid":false,"given":"Juwon","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heeyoung","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ye Chan","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-5534-4650","authenticated-orcid":false,"given":"Myoung Jung","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-2452-4423","authenticated-orcid":false,"given":"Ju Youn","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5416-9691","authenticated-orcid":false,"given":"Kyoung-Min","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1025-7283","authenticated-orcid":false,"given":"Young Keun","family":"On","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3288-0594","authenticated-orcid":false,"given":"Seung-Jung","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,11,13]]},"reference":[{"issue":"11","key":"2159_CR1","doi-asserted-by":"publisher","first-page":"1296","DOI":"10.1016\/j.jacep.2017.05.007","volume":"3","author":"DJ Cantillon","year":"2017","unstructured":"Cantillon DJ, Exner DV, Badie N, Davis K, Gu NY, Nabutovsky Y, et al. Complications and health care costs associated with transvenous cardiac pacemakers in a nationwide assessment. JACC: Clinical Electrophysiology. 2017;3(11):1296\u2013305. https:\/\/doi.org\/10.1016\/j.jacep.2017.05.007.","journal-title":"JACC: Clinical Electrophysiology"},{"key":"2159_CR2","doi-asserted-by":"publisher","DOI":"10.3390\/jcm14062058","author":"J Simpson","year":"2025","unstructured":"Simpson J, Yoder M, Christian-Miller N, Wheat H, Kovacs B, Cunnane R, et al. Long-term complications related to cardiac implantable electronic devices. J Clin Med. 2025. https:\/\/doi.org\/10.3390\/jcm14062058.","journal-title":"J Clin Med"},{"issue":"11","key":"2159_CR3","doi-asserted-by":"publisher","first-page":"1421","DOI":"10.1016\/j.jacep.2018.07.011","volume":"4","author":"SJ Park","year":"2018","unstructured":"Park SJ, Gentry JL, Varma N, Wazni O, Tarakji KG, Mehta A, et al. Transvenous extraction of pacemaker and defibrillator leads and the risk of tricuspid valve regurgitation. JACC: Clin Electrophysiol. 2018;4(11):1421\u20138. https:\/\/doi.org\/10.1016\/j.jacep.2018.07.011.","journal-title":"JACC: Clin Electrophysiol"},{"issue":"12","key":"2159_CR4","doi-asserted-by":"publisher","first-page":"e503","DOI":"10.1016\/j.hrthm.2017.09.001","volume":"14","author":"FM Kusumoto","year":"2017","unstructured":"Kusumoto FM, Schoenfeld MH, Wilkoff BL, Berul CI, Birgersdotter-Green UM, Carrillo R, et al. 2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction. Heart Rhythm. 2017;14(12):e503\u201351. https:\/\/doi.org\/10.1016\/j.hrthm.2017.09.001.","journal-title":"Heart Rhythm"},{"issue":"1","key":"2159_CR5","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.amjcard.2016.10.012","volume":"119","author":"MF El-Chami","year":"2017","unstructured":"El-Chami MF, Merchant FM, Leon AR. Leadless pacemakers. Am J Cardiol. 2017;119(1):145\u20138. https:\/\/doi.org\/10.1016\/j.amjcard.2016.10.012.","journal-title":"Am J Cardiol"},{"issue":"6","key":"2159_CR6","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1056\/NEJMoa1511643","volume":"374","author":"D Reynolds","year":"2016","unstructured":"Reynolds D, Duray GZ, Omar R, Soejima K, Neuzil P, Zhang S, et al. A leadless intracardiac transcatheter pacing system. N Engl J Med. 2016;374(6):533\u201341. https:\/\/doi.org\/10.1056\/NEJMoa1511643.","journal-title":"N Engl J Med"},{"issue":"12","key":"2159_CR7","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.1056\/NEJMoa1507192","volume":"373","author":"VY Reddy","year":"2015","unstructured":"Reddy VY, Exner DV, Cantillon DJ, Doshi R, Bunch TJ, Tomassoni GF, et al. Percutaneous implantation of an entirely intracardiac leadless pacemaker. N Engl J Med. 2015;373(12):1125\u201335. https:\/\/doi.org\/10.1056\/NEJMoa1507192.","journal-title":"N Engl J Med"},{"issue":"8","key":"2159_CR8","doi-asserted-by":"publisher","first-page":"1289","DOI":"10.1016\/j.hrthm.2022.03.1226","volume":"19","author":"F Haddadin","year":"2022","unstructured":"Haddadin F, Majmundar M, Jabri A, Pecha L, Scott C, Daher M, et al. Clinical outcomes and predictors of complications in patients undergoing leadless pacemaker implantation. Heart Rhythm. 2022;19(8):1289\u201396. https:\/\/doi.org\/10.1016\/j.hrthm.2022.03.1226.","journal-title":"Heart Rhythm"},{"key":"2159_CR9","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euae199","author":"N Molitor","year":"2024","unstructured":"Molitor N, Saleem-Talib S, Ramanna H, Hofer D, Breitenstein A, Steffel J. Leadless pacemaker implantation via the internal jugular vein. Europace. 2024. https:\/\/doi.org\/10.1093\/europace\/euae199.","journal-title":"Europace"},{"issue":"10","key":"2159_CR10","doi-asserted-by":"publisher","first-page":"1248","DOI":"10.1111\/pace.14587","volume":"45","author":"S Saleem-Talib","year":"2022","unstructured":"Saleem-Talib S, van Driel VJ, Nikolic T, van Wessel H, Louman H, Borleffs CJW, et al. The jugular approach for leadless pacing: a novel and safe alternative. Pacing Clin Electrophysiol. 2022;45(10):1248\u201354. https:\/\/doi.org\/10.1111\/pace.14587.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"7","key":"2159_CR11","doi-asserted-by":"publisher","first-page":"1127","DOI":"10.1253\/circj.CJ-24-0083","volume":"88","author":"K Soejima","year":"2024","unstructured":"Soejima K, Hilpisch K, Samec ML, Temple RL, Bonner MD. Jugular approach for the transcatheter pacemaker implant - better access for smaller hearts? Circ J. 2024;88(7):1127\u201334. https:\/\/doi.org\/10.1253\/circj.CJ-24-0083.","journal-title":"Circ J"},{"issue":"4","key":"2159_CR12","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1111\/pace.13607","volume":"42","author":"S Saleem-Talib","year":"2019","unstructured":"Saleem-Talib S, van Driel VJ, Chaldoupi S-M, Nikolic T, van Wessel H, Borleffs CJW, et al. Leadless pacing: going for the jugular. Pacing Clin Electrophysiol. 2019;42(4):395\u20139. https:\/\/doi.org\/10.1111\/pace.13607.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"4","key":"2159_CR13","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1191\/1358863x03vm508oa","volume":"8","author":"K Kr\u00f6ger","year":"2003","unstructured":"Kr\u00f6ger K, Ose C, Rudofsky G, Roesener J, Weiland D, Hirche H. Peripheral veins: influence of gender, body mass index, age and varicose veins on cross-sectional area. Vasc Med. 2003;8(4):249\u201355. https:\/\/doi.org\/10.1191\/1358863x03vm508oa.","journal-title":"Vasc Med"},{"issue":"4","key":"2159_CR14","doi-asserted-by":"publisher","DOI":"10.1161\/circep.122.011447","volume":"16","author":"MJ Shah","year":"2023","unstructured":"Shah MJ, Borquez AA, Cortez D, McCanta AC, De Filippo P, Whitehill RD, et al. Transcatheter leadless pacing in children: a PACES collaborative study in the real-world setting. Circulation: Arrhythmia and Electrophysiology. 2023;16(4):e011447. https:\/\/doi.org\/10.1161\/circep.122.011447.","journal-title":"Circulation: Arrhythmia and Electrophysiology"},{"issue":"9","key":"2159_CR15","doi-asserted-by":"publisher","first-page":"679","DOI":"10.2217\/fca-2021-0139","volume":"18","author":"A El-Bokl","year":"2022","unstructured":"El-Bokl A, Siddeek H, Hou C, Leslie A, Jimenez E, Cortez D. Pediatric Micra leadless pacemaker implantation via internal jugular and femoral veins: experience with 11 patients. Future Cardiol. 2022;18(9):679\u201386. https:\/\/doi.org\/10.2217\/fca-2021-0139.","journal-title":"Future Cardiol"},{"issue":"8","key":"2159_CR16","doi-asserted-by":"publisher","DOI":"10.1007\/s11883-018-0741-y","volume":"20","author":"Y Chacko","year":"2018","unstructured":"Chacko Y, Parikh RV, Tremmel JA. Vascular access-related complications in women: temporal trends, emerging data, and the current state of interventional cardiology practice. Curr Atheroscler Rep. 2018;20(8):41. https:\/\/doi.org\/10.1007\/s11883-018-0741-y.","journal-title":"Curr Atheroscler Rep"},{"issue":"12","key":"2159_CR17","doi-asserted-by":"publisher","DOI":"10.1161\/jaha.121.021965","volume":"10","author":"A Spirito","year":"2021","unstructured":"Spirito A, Gragnano F, Corpataux N, Vaisnora L, Galea R, Svab S, et al. Sex-based differences in bleeding risk after percutaneous coronary intervention and implications for the academic research consortium high bleeding risk criteria. J Am Heart Assoc. 2021;10(12):e021965. https:\/\/doi.org\/10.1161\/jaha.121.021965.","journal-title":"J Am Heart Assoc"},{"issue":"12","key":"2159_CR18","doi-asserted-by":"publisher","DOI":"10.31083\/j.rcm2512440","volume":"25","author":"S Saleem-Talib","year":"2024","unstructured":"Saleem-Talib S, Hoevenaars CPR, van Driel VJ, van Wessel H, van der Heijden J, Ramanna H, et al. Jugular vascular closure and scar formation after leadless pacemaker implantation. Rev Cardiovasc Med. 2024;25(12):440. https:\/\/doi.org\/10.31083\/j.rcm2512440.","journal-title":"Rev Cardiovasc Med"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-025-02159-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-025-02159-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-025-02159-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,23]],"date-time":"2026-03-23T23:01:35Z","timestamp":1774306895000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-025-02159-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,13]]},"references-count":18,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026,4]]}},"alternative-id":["2159"],"URL":"https:\/\/doi.org\/10.1007\/s10840-025-02159-9","relation":{},"ISSN":["1572-8595"],"issn-type":[{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,13]]},"assertion":[{"value":"3 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 October 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors confirm that patient consent is not applicable to this article. This is a retrospective case report using de-identified data; therefore, the IRB did not require consent from the patient.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"The authors have no competing interests to declare that are relevant to the content of this article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}