{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T05:03:38Z","timestamp":1788498218847,"version":"build-2803163510"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2025,10,23]],"date-time":"2025-10-23T00:00:00Z","timestamp":1761177600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,10,23]],"date-time":"2025-10-23T00:00:00Z","timestamp":1761177600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"DOI":"10.1007\/s10840-025-02162-0","type":"journal-article","created":{"date-parts":[[2025,10,23]],"date-time":"2025-10-23T07:57:29Z","timestamp":1761206249000},"page":"249-257","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["When low is not low enough: zero-fluoroscopy atrial fibrillation ablation using the VARIPULSE\u2122 pulsed field system\u2014a\u00a0prospective single-center study"],"prefix":"10.1007","volume":"69","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-1580-3496","authenticated-orcid":false,"given":"E.","family":"Simeon","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Roeun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Miled","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"O.","family":"Villejoubert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Jorrot","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"N.","family":"Mignot","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Durand","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Aissani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F.","family":"Sebag","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,10,23]]},"reference":[{"issue":"8","key":"2162_CR1","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1161\/CIRCULATIONAHA.113.005119","volume":"129","author":"SS Chugh","year":"2014","unstructured":"Chugh SS, Havmoeller R, Narayanan K, Singh D, Rienstra M, Benjamin EJ, et al. Worldwide epidemiology of atrial fibrillation: a global burden of disease 2010 study. Circulation. 2014;129(8):837\u201347.","journal-title":"Circulation"},{"issue":"5","key":"2162_CR2","doi-asserted-by":"publisher","first-page":"921","DOI":"10.1007\/s10840-024-01771-5","volume":"67","author":"S Tzeis","year":"2024","unstructured":"Tzeis S, Gerstenfeld EP, Kalman J, Saad E, Shamloo AS, Andrade JG, et al. EHRA\/HRS\/APHRS\/LAHRS 2024 expert consensus statement on catheter and surgical ablation of atrial fibrillation. J Interv Card Electrophysiol. 2024;67(5):921\u20131072. https:\/\/doi.org\/10.1007\/s10840-024-01771-5.","journal-title":"J Interv Card Electrophysiol"},{"issue":"6","key":"2162_CR3","first-page":"863","volume":"9","author":"JG Andrade","year":"2012","unstructured":"Andrade JG, Khairy P, Macle L, Packer DL, Lehmann JW, Holcomb RG, et al. Incidence and significance of esophageal thermal injury during RF catheter ablation for atrial fibrillation. Heart Rhythm. 2012;9(6):863\u20139.","journal-title":"Heart Rhythm"},{"issue":"1","key":"2162_CR4","first-page":"32","volume":"3","author":"R Cappato","year":"2010","unstructured":"Cappato R, Calkins H, Chen SA, Davies W, Iesaka Y, Kalman J, et al. Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circulation: Arrhythmia and Electrophysiology. 2010;3(1):32\u20138.","journal-title":"Circulation: Arrhythmia and Electrophysiology"},{"issue":"27","key":"2162_CR5","doi-asserted-by":"publisher","first-page":"2458","DOI":"10.1093\/eurheartj\/ehad250","volume":"44","author":"RR Tilz","year":"2023","unstructured":"Tilz RR, Fink T, Heeger CH, Lemes C, Rillig A, Maurer T, et al. A worldwide survey on incidence, management, and prognosis of oesophageal fistula formation following atrial fibrillation catheter ablation: the POTTER-AF study. Eur Heart J. 2023;44(27):2458\u201369.","journal-title":"Eur Heart J"},{"issue":"9","key":"2162_CR6","doi-asserted-by":"publisher","first-page":"1068","DOI":"10.1016\/j.jacc.2020.07.007","volume":"76","author":"VY Reddy","year":"2020","unstructured":"Reddy VY, Anic A, Koruth J, Petru J, Funasako M, Minami K, et al. Pulsed field ablation in patients with persistent atrial fibrillation. J Am Coll Cardiol. 2020;76(9):1068\u201380.","journal-title":"J Am Coll Cardiol"},{"issue":"4","key":"2162_CR7","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1056\/NEJMcpc2300906","volume":"389","author":"A Verma","year":"2023","unstructured":"Verma A, Boersma LVA. Pulsed field ablation for atrial fibrillation\u2014ready for prime time? N Engl J Med. 2023;389(4):360\u20132.","journal-title":"N Engl J Med"},{"issue":"19","key":"2162_CR8","doi-asserted-by":"publisher","first-page":"1422","DOI":"10.1161\/CIRCULATIONAHA.123.063988","volume":"147","author":"A Verma","year":"2023","unstructured":"Verma A, Haines DE, Boersma LV, Sood N, Natale A, Marchlinski FE, et al. Pulsed field ablation for the treatment of atrial fibrillation: PULSED AF pivotal trial. Circulation. 2023;147(19):1422\u201332. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.123.063988.","journal-title":"Circulation"},{"issue":"9","key":"2162_CR9","doi-asserted-by":"publisher","first-page":"1817","DOI":"10.1111\/jce.16366","volume":"35","author":"DG Nair","year":"2024","unstructured":"Nair DG, Gomez T, De Potter T. Varipulse: a step-by-step guide to pulmonary vein isolation. J Cardiovasc Electrophysiol. 2024;35(9):1817\u201327.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"1","key":"2162_CR10","first-page":"euac279","volume":"25","author":"P Loh","year":"2023","unstructured":"Loh P, Gal P, Chierchia GB, de Asmundis C, Velagi\u0107 V, Sarkozy A, et al. Pulsed field ablation for pulmonary vein isolation: a prospective, multicenter study. Europace. 2023;25(1):euac279.","journal-title":"Europace."},{"issue":"3","key":"2162_CR11","doi-asserted-by":"publisher","first-page":"e011780","DOI":"10.1161\/CIRCEP.122.011780","volume":"16","author":"M Duytschaever","year":"2023","unstructured":"Duytschaever M, De Potter T, Grimaldi M, Anic A, Martinek M, Metzner A, et al. inspIRE Trial Investigators Paroxysmal atrial fibrillation ablation using a novel variable-loop biphasic pulsed field ablation catheter integrated with a 3-dimensional mapping system: 1-year outcomes of the multicenter inspIRE Study. Circ Arrhythm Electrophysiol. 2023;16(3):e011780.","journal-title":"Circ Arrhythm Electrophysiol."},{"issue":"6","key":"2162_CR12","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1161\/CIRCEP.109.872093","volume":"2","author":"JD Ferguson","year":"2009","unstructured":"Ferguson JD, Helms A, Mangrum JM, Mahapatra S, Mason P, Bilchick K, et al. Catheter ablation of atrial fibrillation without fluoroscopy using intracardiac echocardiography and electroanatomic mapping. Circulation: Arrhythmia and Electrophysiology. 2009;2(6):611\u20139. https:\/\/doi.org\/10.1161\/CIRCEP.109.872093.","journal-title":"Circulation: Arrhythmia and Electrophysiology"},{"key":"2162_CR13","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-024-01904-w","author":"NO Palmeri","year":"2024","unstructured":"Palmeri NO, Alyesh D, Keith M, Greenhaw E, Erickson C, Choe W, et al. Pulsed-field ablation for atrial fibrillation without the use of fluoroscopy. J Interv Card Electrophysiol. 2024. https:\/\/doi.org\/10.1007\/s10840-024-01904-w.","journal-title":"J Interv Card Electrophysiol"},{"issue":"4","key":"2162_CR14","doi-asserted-by":"publisher","DOI":"10.1007\/s11886-021-01461-y","volume":"23","author":"CS Purtell","year":"2021","unstructured":"Purtell CS, Kipp RT, Eckhardt LL. Into a fluoroless future: an appraisal of fluoroscopy-free techniques in clinical cardiac electrophysiology. Curr Cardiol Rep. 2021;23(4):28. https:\/\/doi.org\/10.1007\/s11886-021-01461-y.","journal-title":"Curr Cardiol Rep"},{"issue":"3","key":"2162_CR15","doi-asserted-by":"publisher","first-page":"4018","DOI":"10.19102\/icrm.2020.110305","volume":"11","author":"U Canpolat","year":"2020","unstructured":"Canpolat U, Faggioni M, Della Rocca DG, Chen Q, Ayhan H, Vu AA, et al. State of fluoroless procedures in cardiac electrophysiology practice. J Innov Cardiac Rhythm Manage. 2020;11(3):4018\u201329. https:\/\/doi.org\/10.19102\/icrm.2020.110305.","journal-title":"J Innov Cardiac Rhythm Manage"},{"issue":"11","key":"2162_CR16","doi-asserted-by":"publisher","first-page":"2083","DOI":"10.1016\/j.hrthm.2024.04.090","volume":"21","author":"J Osorio","year":"2024","unstructured":"Osorio J, Miranda-Arboleda AF, Velasco A, Gutierrez L, Chocron S, Vega S, et al. REAL-AF Investigators. Real-world data of radiofrequency catheter ablation in paroxysmal atrial fibrillation: short- and long-term clinical outcomes from the prospective multicenter REAL-AF Registry. Heart Rhythm. 2024;21(11):2083\u201391.","journal-title":"Heart Rhythm."},{"key":"2162_CR17","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-025-01981-5","author":"M Borlich","year":"2025","unstructured":"Borlich M, Groschke S, Wietgrefe J, Alken FA, Unger L, Moser J, et al. Near-zero fluoroscopy workflow for pulmonary vein isolation in atrial fibrillation using a variable loop, 3D-integrated circular PFA catheter (Varipulse\u2122): initial single-center experience with the first 35 patients. J Interv Card Electrophysiol. 2025. https:\/\/doi.org\/10.1007\/s10840-025-01981-5.","journal-title":"J Interv Card Electrophysiol"},{"key":"2162_CR18","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2025.06.036","author":"J Demian","year":"2025","unstructured":"Demian J, Younis A, Wazni OM, Santangeli P, Mdaihly M, Watfa A, et al. Pulsed-field ablation of atrial flutter: insights from a large-volume U.S. center. JACC Clin Electrophysiol. 2025. https:\/\/doi.org\/10.1016\/j.jacep.2025.06.036.","journal-title":"JACC Clin Electrophysiol."},{"issue":"8","key":"2162_CR19","doi-asserted-by":"publisher","first-page":"2013","DOI":"10.1111\/jce.16719","volume":"36","author":"JF Rodriguez-Riascos","year":"2025","unstructured":"Rodriguez-Riascos JF, Vemulapalli HS, Muthu P, Prajapati P, Su W, Shen WK, et al. Safety and efficacy of pulsed field ablation for cavotricuspid isthmus-dependent flutter: a systematic literature review. J Cardiovasc Electrophysiol. 2025;36(8):2013\u201324. https:\/\/doi.org\/10.1111\/jce.16719.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2162_CR20","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2025.08.010","author":"FIP Farnir","year":"2025","unstructured":"Farnir FIP, Chaldoupi SM, Hermans B, Rademakers LM, Vernooy K, Crijns HJ, et al. Ablation of cavotricuspid isthmus\u2013dependent atrial flutter using a focal monopolar pulsed-field ablation catheter: feasibility, periprocedural coronary spasms and conduction disorders. Heart Rhythm. 2025. https:\/\/doi.org\/10.1016\/j.hrthm.2025.08.010.","journal-title":"Heart Rhythm"},{"issue":"2","key":"2162_CR21","first-page":"272","volume":"5","author":"E Picano","year":"2012","unstructured":"Picano E, Vano E, Rehani MM, Cuocolo A, Mont L, Bodi V, et al. Radiation exposure in the electrophysiology laboratory. Circ Arrhythm Electrophysiol. 2012;5(2):272\u201382.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"4","key":"2162_CR22","first-page":"407","volume":"63","author":"JA Goldstein","year":"2004","unstructured":"Goldstein JA, Balter S, Cowley M, Hodgson J, Klein LW. Occupational hazards of interventional cardiologists: prevalence of orthopedic health problems in contemporary practice. Catheter Cardiovasc Interv. 2004;63(4):407\u201311.","journal-title":"Catheter Cardiovasc Interv"},{"issue":"1","key":"2162_CR23","first-page":"1","volume":"42","author":"M Casella","year":"2015","unstructured":"Casella M, Dello Russo A, Pelargonio G, Del Greco M, Zingarini G, Piacenti M, et al. Electroanatomical mapping systems: technologies and clinical applications in cardiac electrophysiology. J Interv Card Electrophysiol. 2015;42(1):1\u201315.","journal-title":"J Interv Card Electrophysiol"},{"issue":"6","key":"2162_CR24","first-page":"944","volume":"23","author":"LP Bosman","year":"2021","unstructured":"Bosman LP, Hollander MH, Kelder JC, de Groot JR. Fluoroscopy-free catheter ablation of atrial fibrillation: a systematic review and meta-analysis. Europace. 2021;23(6):944\u201356.","journal-title":"Europace"},{"issue":"4","key":"2162_CR25","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1007\/s10840-024-01904-w","volume":"68","author":"NO Palmeri","year":"2025","unstructured":"Palmeri NO, Alyesh D, Keith M, Greenhaw E, Erickson C, Choe W, et al. Pulsed-field ablation for atrial fibrillation without the use of fluoroscopy. J Interv Card Electrophysiol. 2025;68(4):757\u201365. https:\/\/doi.org\/10.1007\/s10840-024-01904-w.","journal-title":"J Interv Card Electrophysiol"},{"key":"2162_CR26","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2025.08.010","author":"L Chehirlian","year":"2025","unstructured":"Chehirlian L, Koutbi L, Mancini J, Hourdain J, Robin-Vitton R, Wilkin M, et al. High incidence of phrenic nerve injury in patients undergoing pulsed field ablation for atrial fibrillation. Heart Rhythm. 2025. https:\/\/doi.org\/10.1016\/j.hrthm.2025.08.010.","journal-title":"Heart Rhythm"},{"key":"2162_CR27","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-025-02035-6","author":"G Filiberti","year":"2025","unstructured":"Filiberti G, Antonelli G, Falasconi G, Villaschi A, Figliozzi S, Ruffo MM, et al. The use of cardiac imaging in patients undergoing atrial fibrillation ablation. J Interv Card Electrophysiol. 2025. https:\/\/doi.org\/10.1007\/s10840-025-02035-6.","journal-title":"J Interv Card Electrophysiol"},{"issue":"3","key":"2162_CR28","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.acvd.2023.11.016","volume":"117","author":"F Sacher","year":"2024","unstructured":"Sacher F, Bacquelin R, Bessiere F, Mondoly P, Cardin C, Combes N, et al. Position paper on sustainability in cardiac pacing and electrophysiology from the Working Group of Cardiac Pacing and Electrophysiology of the French Society of Cardiology. Arch Cardiovasc Dis. 2024;117(3):224\u201331.","journal-title":"Arch Cardiovasc Dis"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-025-02162-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-025-02162-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-025-02162-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T17:02:01Z","timestamp":1770310921000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-025-02162-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,23]]},"references-count":28,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,3]]}},"alternative-id":["2162"],"URL":"https:\/\/doi.org\/10.1007\/s10840-025-02162-0","relation":{},"ISSN":["1572-8595"],"issn-type":[{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,23]]},"assertion":[{"value":"7 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 October 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 October 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the institutional review board of Institut Mutualiste Montsouris (direction de la recherche clinique, de la qualit\u00e9, des risques et des relations avec les usagers). All patients provided written informed consent.Contact: recherche.clinique@imm.fr.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}