{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T23:36:04Z","timestamp":1793144164982,"version":"4.5.0"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T00:00:00Z","timestamp":1771804800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T00:00:00Z","timestamp":1771804800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Automatic capture confirmation algorithms regularly evaluate pacing capture threshold (PCT) and adjust energy output to deliver a tailored safety margin over the PCT. Abbott AutoCapture\u2122 Algorithm provides beat-by-beat capture confirmation and delivers a high-output backup safety pulse in the event of non-capture. Our objective was to evaluate the longitudinal performance and stability of the Abbott AutoCapture\u2122 algorithm in patients with LBBAP.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>De-identified remote device data were retrospectively analyzed from consecutive patients in our hospital who received AutoCapture enabled Abbott pacemakers with LBBAP from June 2021 to August 2023. Device stored AutoCapture PCT measurements were then evaluated incrementally over an approximate 2-year period, to evaluate longer-term trends and performance, and also compared with the in-clinic manual PCT.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 619 patients with either single chamber (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200989) or dual-chamber Abbott devices (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009530) were identified. AutoCapture and manually measured PCTs in-clinic were within 0.25\u00a0V in 600\/615 (97.6%) patients, with average PCTs of 0.76\u00a0V\u2009\u00b1\u20090.28 and 0.80\u00a0V\u2009\u00b1\u20090.26 respectively. At 1, 3, 6, 12, and 24-month remote follow-up, average AutoCapture PCTs were 0.67\u00a0V\u2009\u00b1\u20090.29 (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009594), 0.66\u00a0V\u2009\u00b1\u20090.25 (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009560), 0.71\u00a0V\u2009\u00b1\u20090.29 (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009543), 0.77\u00a0V\u2009\u00b1\u20090.29 (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009447) and 0.81\u00a0V\u2009\u00b1\u20090.28 (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009112), respectively. AutoCapture was found to be effective in assessing PCT and was activated in the majority of patients (619\/644, 97%) with no clinical complications related to its usage.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The AutoCapture algorithm measured accurate PCTs compared to manual in-clinic and showed stable trend during follow-up of 2\u00a0years in patients with LBBAP.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s10840-025-02229-y","type":"journal-article","created":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T09:53:37Z","timestamp":1771840417000},"page":"729-735","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Performance of automatic capture confirmation algorithm in a large cohort of pacemaker patients with left bundle branch area pacing"],"prefix":"10.1007","volume":"69","author":[{"given":"Matthew A.","family":"Bernabei","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandeep","family":"Bansal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R. Ward","family":"Pulliam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5758-413X","authenticated-orcid":false,"given":"Fady","family":"Dawoud","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenwen","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leyla","family":"Sabet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyungmoo","family":"Ryu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luke","family":"McSpadden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey","family":"Arkles","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,2,23]]},"reference":[{"issue":"5","key":"2229_CR1","doi-asserted-by":"publisher","first-page":"696","DOI":"10.1016\/j.hrthm.2017.12.022","volume":"15","author":"P Vijayaraman","year":"2018","unstructured":"Vijayaraman P, et al. Permanent His-bundle pacing: long-term lead performance and clinical outcomes. Heart Rhythm. 2018;15(5):696\u2013702.","journal-title":"Heart Rhythm"},{"issue":"12","key":"2229_CR2","doi-asserted-by":"publisher","first-page":"1758","DOI":"10.1016\/j.hrthm.2019.05.014","volume":"16","author":"Y Li","year":"2019","unstructured":"Li Y, et al. Left bundle branch pacing for symptomatic bradycardia: implant success rate, safety, and pacing characteristics. Heart Rhythm. 2019;16(12):1758\u201365.","journal-title":"Heart Rhythm"},{"issue":"12","key":"2229_CR3","first-page":"1736 e1","volume":"33","author":"W Huang","year":"2017","unstructured":"Huang W, et al. A novel pacing strategy with low and stable output: pacing the left bundle branch immediately beyond the conduction block. Can J Cardiol. 2017;33(12):1736 e1-1736 e3.","journal-title":"Can J Cardiol"},{"issue":"40","key":"2229_CR4","doi-asserted-by":"publisher","first-page":"4161","DOI":"10.1093\/eurheartj\/ehac445","volume":"43","author":"M Jastrzebski","year":"2022","unstructured":"Jastrzebski M, et al. Left bundle branch area pacing outcomes: the multicentre European MELOS study. Eur Heart J. 2022;43(40):4161\u201373.","journal-title":"Eur Heart J"},{"issue":"35","key":"2229_CR5","doi-asserted-by":"publisher","first-page":"3427","DOI":"10.1093\/eurheartj\/ehab364","volume":"42","author":"M Glikson","year":"2021","unstructured":"Glikson M, et al. 2021 ESC guidelines on cardiac pacing and cardiac resynchronization therapy. Eur Heart J. 2021;42(35):3427\u2013520.","journal-title":"Eur Heart J"},{"issue":"4","key":"2229_CR6","doi-asserted-by":"publisher","first-page":"1237","DOI":"10.1093\/europace\/euad044","volume":"25","author":"H Burri","year":"2023","unstructured":"Burri H, et al. EHRA clinical consensus statement on conduction system pacing implantation: executive summary. Endorsed by the Asia-Pacific Heart Rhythm Society (APHRS), Canadian Heart Rhythm Society (CHRS) and Latin-American Heart Rhythm Society (LAHRS). Europace. 2023;25(4):1237\u201348.","journal-title":"Europace"},{"issue":"2","key":"2229_CR7","doi-asserted-by":"publisher","first-page":"85","DOI":"10.15420\/aer.2021.16","volume":"10","author":"E Bakelants","year":"2021","unstructured":"Bakelants E, Burri H. Troubleshooting programming of conduction system pacing. Arrhythm Electrophysiol Rev. 2021;10(2):85\u201390.","journal-title":"Arrhythm Electrophysiol Rev"},{"issue":"8","key":"2229_CR8","doi-asserted-by":"publisher","first-page":"634","DOI":"10.1631\/jzus.B1001016","volume":"11","author":"CP Lau","year":"2010","unstructured":"Lau CP, Siu CW. Pacing technology: advances in pacing threshold management. J Zhejiang Univ Sci B. 2010;11(8):634\u20138.","journal-title":"J Zhejiang Univ Sci B"},{"issue":"9","key":"2229_CR9","doi-asserted-by":"publisher","first-page":"e92","DOI":"10.1016\/j.hrthm.2023.03.1525","volume":"20","author":"AM Ferrick","year":"2023","unstructured":"Ferrick AM, et al. 2023 HRS\/EHRA\/APHRS\/LAHRS expert consensus statement on practical management of the remote device clinic. Heart Rhythm. 2023;20(9):e92\u2013144.","journal-title":"Heart Rhythm"},{"issue":"12","key":"2229_CR10","doi-asserted-by":"publisher","first-page":"1774","DOI":"10.1016\/j.hrthm.2019.05.011","volume":"16","author":"P Vijayaraman","year":"2019","unstructured":"Vijayaraman P, et al. Prospective evaluation of feasibility and electrophysiologic and echocardiographic characteristics of left bundle branch area pacing. Heart Rhythm. 2019;16(12):1774\u201382.","journal-title":"Heart Rhythm"},{"issue":"2","key":"2229_CR11","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1016\/j.jacep.2020.08.015","volume":"7","author":"P Vijayaraman","year":"2021","unstructured":"Vijayaraman P, et al. Left bundle branch area pacing for cardiac resynchronization therapy: results from the International LBBAP collaborative study group. JACC Clin Electrophysiol. 2021;7(2):135\u201347.","journal-title":"JACC Clin Electrophysiol"},{"key":"2229_CR12","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euad359","author":"E Sola-Garcia","year":"2023","unstructured":"Sola-Garcia E, et al. Autothreshold algorithm feasibility and safety in left bundle branch pacing. Europace. 2023. https:\/\/doi.org\/10.1093\/europace\/euad359.","journal-title":"Europace"},{"issue":"9","key":"2229_CR13","doi-asserted-by":"publisher","first-page":"1092","DOI":"10.1111\/pace.14777","volume":"46","author":"C Ghiglieno","year":"2023","unstructured":"Ghiglieno C, et al. Left bundle branch area pacing (LBBAP) auto threshold algorithms evaluation for conduction system pacing: the LATECS pilot trial. Pacing Clin Electrophysiol. 2023;46(9):1092\u20138.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"2","key":"2229_CR14","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.120.009261","volume":"14","author":"L Su","year":"2021","unstructured":"Su L, et al. Long-term safety and feasibility of left bundle branch pacing in a large single-center study. Circ Arrhythm Electrophysiol. 2021;14(2):e009261.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2229_CR15","doi-asserted-by":"publisher","DOI":"10.1111\/jce.16287","author":"KA Ellenbogen","year":"2024","unstructured":"Ellenbogen KA, et al. Left bundle branch area pacing using a lumenless lead: a systematic literature review and meta-analysis. J Cardiovasc Electrophysiol. 2024. https:\/\/doi.org\/10.1111\/jce.16287.","journal-title":"J Cardiovasc Electrophysiol"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-025-02229-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-025-02229-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-025-02229-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T18:41:36Z","timestamp":1781635296000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-025-02229-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,23]]},"references-count":15,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,6]]}},"alternative-id":["2229"],"URL":"https:\/\/doi.org\/10.1007\/s10840-025-02229-y","relation":{"has-preprint":[{"id-type":"doi","id":"10.22541\/au.174144613.36819063\/v1","asserted-by":"object"}]},"ISSN":["1572-8595"],"issn-type":[{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,23]]},"assertion":[{"value":"18 June 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 February 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"No funding support was provided for conducting this study. F.D., W.L., L.S., K.R., and L.M. are employees and shareholders in Abbott. M.B., S.B., W.P., J.A., have no competing interests to declare relevant to the content of this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}