{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T19:17:50Z","timestamp":1792783070036,"version":"4.5.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T00:00:00Z","timestamp":1768348800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T00:00:00Z","timestamp":1768348800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Charit\u00e9 - Universit\u00e4tsmedizin Berlin","id":[{"id":"https:\/\/ror.org\/001w7jn25","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Pulsed field ablation (PFA) is an innovative option for the treatment of atrial fibrillation (AF). As different PFA technologies are now available, the safety and efficacy of each ablation system must be individually demonstrated. For the circular multielectrode array catheter, only the pivotal trial to date has been published showing efficacy and safety comparable to other PFA technologies. This study aimed to evaluate outcomes of this technology in a real-world cohort.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Consecutive patients undergoing their first pulmonary vein isolation (PVI) using the circular multielectrode array catheter were included. All patients were prospectively enrolled in the Berlin Best-Ablate registry. Follow-up evaluations were performed at 3, 6, and 12 months using 24-hour Holter electrocardiography.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>A total of 81 patients (37 with paroxysmal AF and 44 with persistent AF) were included. Acute PVI was achieved in all patients (median age, 69 years; 64.2% male). After a mean follow-up of 6.7\u2009\u00b1\u20095.1 months, recurrence of any atrial arrhythmia was observed in 23 of 81 patients (28.4%). Four patients (three with atrial tachycardia (AT) and one with AF) underwent a repeat ablation procedure. In both AT cases, PVI was found to be intact, whereas in the AF case, re-isolation of the pulmonary veins was required. One patient experienced a major complication (stroke).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>In this prospective real-world study, PFA using the circular multielectrode array catheter (PulseSelect catheter) proved to be effective in patients with both paroxysmal and persistent AF, corroborating the findings of the pivotal trial.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s10840-025-02234-1","type":"journal-article","created":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T07:52:47Z","timestamp":1768377167000},"page":"1253-1260","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Pulse field ablation in patients with paroxysmal and persistent atrial fibrillation using the circular multielectrode array catheter: first outcome data in a real-world prospective study"],"prefix":"10.1007","volume":"69","author":[{"given":"Verena","family":"Tscholl","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshinori","family":"Chiba","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp","family":"Formum","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Wienke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Nagel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johannes","family":"Lucas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Huemer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulf","family":"Landmesser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nikolaos","family":"Dagres","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felix","family":"Hohendanner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerhard","family":"Hindricks","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"H\u00e4ttasch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp","family":"Attanasio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,1,14]]},"reference":[{"key":"2234_CR1","first-page":"1256","volume":"24","author":"E Ekanem","year":"2022","unstructured":"Ekanem E, Reddy VY, Schmidt B, Reichlin T, Neven K, Metzner A, et al. Multi-national survey on the methods, efficacy, and safety on the post-approval clinical use of pulsed field ablation (MANIFEST-PF). Europace: European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European society. Cardiol. 2022;24:1256\u201366.","journal-title":"Cardiol"},{"key":"2234_CR2","doi-asserted-by":"publisher","first-page":"1218","DOI":"10.1016\/j.hrthm.2024.04.102","volume":"21","author":"MK Turagam","year":"2024","unstructured":"Turagam MK, Neuzil P, Petru J, Funasako M, Koruth JS, Skoda J, et al. AF ablation using a novel \u201csingle-shot\u201d map-and-ablate spherical array pulsed field ablation catheter: 1-year outcomes of the first-in-human PULSE-EU trial. Heart Rhythm. 2024;21:1218\u201326.","journal-title":"Heart Rhythm"},{"key":"2234_CR3","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.121.010168","volume":"15","author":"A Verma","year":"2022","unstructured":"Verma A, Boersma L, Haines DE, Natale A, Marchlinski FE, Sanders P, et al. First-in-human experience and acute procedural outcomes using a novel pulsed field ablation system: the PULSED AF pilot trial. Circ Arrhythm Electrophysiol. 2022;15:e010168.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2234_CR4","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.122.011780","volume":"16","author":"M Duytschaever","year":"2023","unstructured":"Duytschaever M, De Potter T, Grimaldi M, Anic A, Vijgen J, Neuzil P, et al. Paroxysmal atrial fibrillation ablation using a novel variable-loop biphasic pulsed field ablation catheter integrated with a 3-dimensional mapping system: 1-year outcomes of the multicenter inspIRE study. Circ Arrhythm Electrophysiol. 2023;16:e011780.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2234_CR5","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euae090","author":"VY Reddy","year":"2024","unstructured":"Reddy VY, Anter E, Peichl P, Rackauskas G, Petru J, Funasako M, et al. First-in-human clinical series of a novel conformable large-lattice pulsed field ablation catheter for pulmonary vein isolation. Europace. 2024. https:\/\/doi.org\/10.1093\/europace\/euae090.","journal-title":"Europace"},{"key":"2234_CR6","doi-asserted-by":"publisher","first-page":"1422","DOI":"10.1161\/CIRCULATIONAHA.123.063988","volume":"147","author":"A Verma","year":"2023","unstructured":"Verma A, Haines DE, Boersma LV, Sood N, Natale A, Marchlinski FE, et al. Pulsed field ablation for the treatment of atrial fibrillation: PULSED AF pivotal trial. Circulation. 2023;147:1422\u201332.","journal-title":"Circulation"},{"key":"2234_CR7","doi-asserted-by":"publisher","first-page":"e31","DOI":"10.1016\/j.hrthm.2024.03.017","volume":"21","author":"S Tzeis","year":"2024","unstructured":"Tzeis S, Gerstenfeld EP, Kalman J, Saad EB, Shamloo AS, Andrade JG, et al. 2024 European heart rhythm Association\/Heart Rhythm society\/Asia Pacific heart rhythm society\/Latin American heart rhythm society expert consensus statement on catheter and surgical ablation of atrial fibrillation. Heart Rhythm. 2024;21:e31\u2013149.","journal-title":"Heart Rhythm"},{"key":"2234_CR8","doi-asserted-by":"publisher","first-page":"2235","DOI":"10.1056\/NEJMoa1602014","volume":"374","author":"KH Kuck","year":"2016","unstructured":"Kuck KH, Brugada J, F\u00fcrnkranz A, Metzner A, Ouyang F, Chun KR, et al. Cryoballoon or radiofrequency ablation for paroxysmal atrial fibrillation. N Engl J Med. 2016;374:2235\u201345.","journal-title":"N Engl J Med"},{"key":"2234_CR9","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euad185","author":"B Schmidt","year":"2023","unstructured":"Schmidt B, Bordignon S, Neven K, Reichlin T, Blaauw Y, Hansen J, et al. EUropean real-world outcomes with Pulsed field ablatiOn in patients with symptomatic atRIAl fibrillation: lessons from the multi-centre EU-PORIA registry. Europace. 2023. https:\/\/doi.org\/10.1093\/europace\/euad185.","journal-title":"Europace"},{"key":"2234_CR10","doi-asserted-by":"publisher","first-page":"1174","DOI":"10.1161\/CIRCULATIONAHA.124.070333","volume":"150","author":"VY Reddy","year":"2024","unstructured":"Reddy VY, Calkins H, Mansour M, Wazni O, Di Biase L, Bahu M, et al. Pulsed field ablation to treat paroxysmal atrial fibrillation: safety and effectiveness in the AdmIRE pivotal trial. Circulation. 2024;150:1174\u201386.","journal-title":"Circulation"},{"key":"2234_CR11","doi-asserted-by":"publisher","DOI":"10.3390\/jcm13226961","author":"J Yogarajah","year":"2024","unstructured":"Yogarajah J, Hutter J, Kahle P, Beaujean P, Tomic M, Hain A, et al. Initial real-world experiences of pulmonary vein isolation and ablation of non-pulmonary vein sites using a novel circular array pulsed field ablation catheter. J Clin Med. 2024. https:\/\/doi.org\/10.3390\/jcm13226961.","journal-title":"J Clin Med"},{"key":"2234_CR12","doi-asserted-by":"publisher","unstructured":"Zylla MM, Mages C, Rahm AK, Wiedmann F, Schweizer PA, Thomas D et al. Comparative evaluation of 2 pulsed field ablation systems for atrial fibrillation: insights from real-world clinical implementation and short-term outcomes. Heart rhythm 2024;22:2201\u20138. https:\/\/doi.org\/10.1016\/j.hrthm.2024.10.068","DOI":"10.1016\/j.hrthm.2024.10.068"},{"key":"2234_CR13","doi-asserted-by":"publisher","unstructured":"Scherr D, Turagam MK, Maury P, Blaauw Y, van der Voort P, Neuzil P et al. Repeat procedures after pulsed field ablation for atrial fibrillation: MANIFEST-REDO Study. Europace: European pacing, arrhythmias, and cardiac electrophysiology: journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European society of cardiology 2025;27:euaf012 . https:\/\/doi.org\/10.1093\/europace\/euaf012","DOI":"10.1093\/europace\/euaf012"},{"key":"2234_CR14","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2024.12.046","author":"M Yokoyama","year":"2025","unstructured":"Yokoyama M, Vlachos K, Fitzgerald J, Ascione C, Kowalewski C, Popa MA, et al. Electrophysiologic characteristics and durability of index pulsed field ablation lesions from redo procedures for atrial arrhythmia recurrences. Heart Rhythm. 2025. https:\/\/doi.org\/10.1016\/j.hrthm.2024.12.046.","journal-title":"Heart Rhythm"},{"key":"2234_CR15","doi-asserted-by":"publisher","first-page":"962","DOI":"10.1016\/j.hrthm.2024.02.010","volume":"21","author":"K Benali","year":"2024","unstructured":"Benali K, Vlachos K, Reddy VY, Verma A, Chun J, Andrade J, et al. Pulsed field ablation for atrial fibrillation in real-life settings: Efficacy, safety, and lesion durability in patients with recurrences. Heart Rhythm. 2024;21:962\u20134.","journal-title":"Heart Rhythm"},{"key":"2234_CR16","doi-asserted-by":"publisher","first-page":"891","DOI":"10.1016\/j.hrthm.2024.08.011","volume":"22","author":"S Mohanty","year":"2025","unstructured":"Mohanty S, Torlapati PG, Casella M, Della Rocca DG, Schiavone M, Doty B, et al. Redefining the blanking period after pulsed field ablation in patients with atrial fibrillation. Heart Rhythm. 2025;22:891\u20137.","journal-title":"Heart Rhythm"},{"key":"2234_CR17","doi-asserted-by":"publisher","first-page":"2425","DOI":"10.1111\/jce.16083","volume":"34","author":"K Plank","year":"2023","unstructured":"Plank K, Bordignon S, Urbanek L, Chen S, Tohoku S, Schaack D, et al. Early recurrences predict late therapy failure after pulsed field ablation of atrial fibrillation. J Cardiovasc Electrophysiol. 2023;34:2425\u201333.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2234_CR18","doi-asserted-by":"publisher","first-page":"1497","DOI":"10.1056\/NEJMoa2502280","volume":"392","author":"T Reichlin","year":"2025","unstructured":"Reichlin T, Kueffer T, Badertscher P, J\u00fcni P, Knecht S, Thalmann G, et al. Pulsed field or cryoballoon ablation for paroxysmal atrial fibrillation. N Engl J Med. 2025;392:1497\u2013507.","journal-title":"N Engl J Med"},{"key":"2234_CR19","doi-asserted-by":"publisher","first-page":"1463","DOI":"10.1016\/j.hrthm.2021.06.1172","volume":"18","author":"C Steinberg","year":"2021","unstructured":"Steinberg C, Champagne J, Deyell MW, Dubuc M, Leong-Sit P, Calkins H, et al. Prevalence and outcome of early recurrence of atrial tachyarrhythmias in the cryoballoon vs irrigated radiofrequency catheter ablation (CIRCA-DOSE) study. Heart Rhythm. 2021;18:1463\u201370.","journal-title":"Heart Rhythm"},{"key":"2234_CR20","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euae180","author":"C Isenegger","year":"2024","unstructured":"Isenegger C, Arnet R, Jordan F, Salis M, Knecht S, Krisai P, et al. Incidence of acute pericarditis after pulsed-field ablation for the treatment of atrial fibrillation. Europace. 2024. https:\/\/doi.org\/10.1093\/europace\/euae180.","journal-title":"Europace"},{"key":"2234_CR21","doi-asserted-by":"publisher","DOI":"10.1111\/jce.70140","author":"T Schreiber","year":"2025","unstructured":"Schreiber T, Rennenberg RV, Br\u00e4mswig TB, Landmesser U, Hindricks G, Nagel P, et al. Comparison of cerebral micro-embolization detected by transcranial Doppler examination between radiofrequency ablation and pulsed field ablation for atrial fibrillation. J Cardiovasc Electrophysiol. 2025. https:\/\/doi.org\/10.1111\/jce.70140.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2234_CR22","doi-asserted-by":"publisher","unstructured":"Shiomi S, Tokuda M, Takato U, Sakurai R, Yamazaki Y, Matsumoto T et al. Real-time detection of microembolic signals using carotid echocardiography: A comparative study of 3 pulsed-field systems. Heart rhythm 2025;23:25\u201331. https:\/\/doi.org\/10.1016\/j.hrthm.2025.06.046","DOI":"10.1016\/j.hrthm.2025.06.046"},{"key":"2234_CR23","unstructured":"Johnson and Johnson. Statement on VARIPULSE\u2122 U.S. External Evaluation. 2025. https:\/\/www.jnj.com\/media-center\/press-releases\/johnson-johnson-statement-on-varipulse-u-s-external-evaluation"},{"key":"2234_CR24","doi-asserted-by":"publisher","first-page":"1660","DOI":"10.1056\/NEJMoa2307291","volume":"389","author":"VY Reddy","year":"2023","unstructured":"Reddy VY, Gerstenfeld EP, Natale A, Whang W, Cuoco FA, Patel C, et al. Pulsed field or conventional thermal ablation for paroxysmal atrial fibrillation. N Engl J Med. 2023;389:1660\u201371.","journal-title":"N Engl J Med"},{"key":"2234_CR25","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa2502280","author":"T Reichlin","year":"2025","unstructured":"Reichlin T, Kueffer T, Badertscher P, J\u00fcni P, Knecht S, Thalmann G, et al. Pulsed field or cryoballoon ablation for paroxysmal atrial fibrillation. N Engl J Med. 2025. https:\/\/doi.org\/10.1056\/NEJMoa2502280.","journal-title":"N Engl J Med"},{"key":"2234_CR26","doi-asserted-by":"publisher","first-page":"2020","DOI":"10.1038\/s41591-024-03114-3","volume":"30","author":"E Ekanem","year":"2024","unstructured":"Ekanem E, Neuzil P, Reichlin T, Kautzner J, van der Voort P, Jais P, et al. Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K study. Nat Med. 2024;30:2020\u20139.","journal-title":"Nat Med"},{"key":"2234_CR27","first-page":"205","volume":"13","author":"A Sorgente","year":"2011","unstructured":"Sorgente A, Chierchia GB, de Asmundis C, Sarkozy A, Namdar M, Capulzini L, et al. Pulmonary vein ostium shape and orientation as possible predictors of occlusion in patients with drug-refractory paroxysmal atrial fibrillation undergoing cryoballoon ablation. Europace: European pacing, arrhythmias, and cardiac electrophysiology: journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European society. Cardiol. 2011;13:205\u201312.","journal-title":"Cardiol"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-025-02234-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-025-02234-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-025-02234-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T07:30:25Z","timestamp":1791358225000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-025-02234-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,14]]},"references-count":27,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["2234"],"URL":"https:\/\/doi.org\/10.1007\/s10840-025-02234-1","relation":{},"ISSN":["1572-8595"],"issn-type":[{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,14]]},"assertion":[{"value":"5 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}