{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T22:26:34Z","timestamp":1793917594515,"version":"4.8.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2026,4,18]],"date-time":"2026-04-18T00:00:00Z","timestamp":1776470400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,18]],"date-time":"2026-04-18T00:00:00Z","timestamp":1776470400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum Schleswig-Holstein - Campus L\u00fcbeck","id":[{"id":"https:\/\/ror.org\/01tvm6f46","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"DOI":"10.1007\/s10840-026-02330-w","type":"journal-article","created":{"date-parts":[[2026,4,18]],"date-time":"2026-04-18T08:51:44Z","timestamp":1776502304000},"page":"2349-2357","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of very high-power short-duration and ablation index guided catheter ablation for cavotricuspid isthmus block"],"prefix":"10.1007","volume":"69","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6881-871X","authenticated-orcid":false,"given":"Bettina","family":"Kirstein","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0480-2521","authenticated-orcid":false,"given":"Martin","family":"Benedikt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8733-6791","authenticated-orcid":false,"given":"Charlotte","family":"Eitel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6302-8671","authenticated-orcid":false,"given":"Jan-Per","family":"Wenzel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3061-2249","authenticated-orcid":false,"given":"Sascha","family":"Hatahet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5578-432X","authenticated-orcid":false,"given":"Tugba Aktemur","family":"\u00d6zalp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9014-8097","authenticated-orcid":false,"given":"Christian-Hendrik","family":"Heeger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0122-7130","authenticated-orcid":false,"given":"Roland Richard","family":"Tilz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,18]]},"reference":[{"issue":"5","key":"2330_CR1","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1111\/j.1540-8159.1996.tb03368.x","volume":"19","author":"FG Cosio","year":"1996","unstructured":"Cosio FG, Arribas F, L\u00f3pez-Gil M, Palacios J. Atrial flutter mapping and ablation I: Studying atrial flutter mechanisms by mapping and entrainment. Pacing Clin Electrophysiol. 1996;19(5):841\u201353.","journal-title":"Pacing Clin Electrophysiol"},{"key":"2330_CR2","doi-asserted-by":"publisher","first-page":"1162","DOI":"10.1053\/euhj.2001.2658","volume":"22","author":"N Saoudi","year":"2001","unstructured":"Saoudi N, Cos\u00edo F, Waldo A, Chen SA, Iesaka Y, Lesh M, et al. A classification of atrial flutter and regular atrial tachycardia according to electrophysiological mechanisms and anatomical bases. Eur Heart J. 2001;22:1162\u201382.","journal-title":"Eur Heart J"},{"key":"2330_CR3","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1161\/CIRCEP.109.871665","volume":"2","author":"FJ P\u00e9rez","year":"2009","unstructured":"P\u00e9rez FJ, Schubert CM, Parvez B, Pathak V, Ellenbogen KA, Wood MA. Long-term outcomes after catheter ablation of cavotricuspid isthmus\u2013dependent atrial flutter: A meta-analysis. Circ Arrhythm Electrophysiol. 2009;2:393\u2013401.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"5","key":"2330_CR4","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1093\/eurheartj\/ehz467","volume":"41","author":"J Brugada","year":"2020","unstructured":"Brugada J, Katritsis DG, Arbelo E, Arribas F, Bax JJ, Blomstr\u00f6m-Lundqvist C, et al. 2019 ESC guidelines for the management of patients with supraventricular tachycardia. Eur Heart J. 2020;41(5):655\u2013720.","journal-title":"Eur Heart J"},{"issue":"5","key":"2330_CR5","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1161\/CIRCEP.108.803650","volume":"1","author":"K Yokoyama","year":"2008","unstructured":"Yokoyama K, Nakagawa H, Shah DC, Lambert H, Leo G, Aeby N, et al. Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus. Circ Arrhythm Electrophysiol. 2008;1(5):354\u201362.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2330_CR6","doi-asserted-by":"publisher","first-page":"1174","DOI":"10.1161\/CIRCEP.113.001094","volume":"7","author":"A Ikeda","year":"2014","unstructured":"Ikeda A, Nakagawa H, Lambert H, Shah D, Fonck E, Yulzari A, et al. Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart. Circ Arrhythm Electrophysiol. 2014;7:1174\u201380.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2330_CR7","doi-asserted-by":"publisher","first-page":"778","DOI":"10.1016\/j.jacep.2019.04.009","volume":"5","author":"VY Reddy","year":"2019","unstructured":"Reddy VY, Grimaldi M, De Potter T, Vijgen MJ, Bulava A, Duytschaever MF, et al. Pulmonary vein isolation with very high-power, short-duration, temperature-controlled lesions: The QDOT-FAST trial. JACC Clin Electrophysiol. 2019;5:778\u201386.","journal-title":"JACC Clin Electrophysiol"},{"key":"2330_CR8","first-page":"100847","volume":"35","author":"RR Tilz","year":"2021","unstructured":"Tilz RR, Sano M, Vogler J, Fink T, Saraei R, Sciacca V, et al. Very high-power short-duration temperature-controlled ablation versus conventional power-controlled ablation for pulmonary vein isolation: The FAST AND FURIOUS-AF study. Int J Cardiol Heart Vasc. 2021;35:100847.","journal-title":"Int J Cardiol Heart Vasc"},{"issue":"4","key":"2330_CR9","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1016\/j.jacep.2022.10.039","volume":"9","author":"L O\u2019Neill","year":"2023","unstructured":"O\u2019Neill L, El Haddad M, Berte B, Kobza R, Hilfiker G, Scherr D, et al. Very high-power ablation for contiguous pulmonary vein isolation: Results from the randomized POWER PLUS trial. JACC Clin Electrophysiol. 2023;9(4):511\u201322.","journal-title":"JACC Clin Electrophysiol"},{"issue":"3","key":"2330_CR10","doi-asserted-by":"publisher","first-page":"880","DOI":"10.1093\/europace\/euac243","volume":"25","author":"CH Heeger","year":"2023","unstructured":"Heeger CH, Sano M, Popescu SS, Subin B, Feher M, Phan HL, et al. Very high-power short-duration ablation for pulmonary vein isolation utilizing a very-close protocol: The FAST AND FURIOUS PVI study. Europace. 2023;25(3):880\u20138.","journal-title":"Europace"},{"issue":"6","key":"2330_CR11","doi-asserted-by":"publisher","first-page":"euae284","DOI":"10.1093\/europace\/euae284","volume":"27","author":"CH Heeger","year":"2025","unstructured":"Heeger CH, Almorad A, Scherr D, Szegedi N, Seidl S, Baran J, et al. Temperature-guided high- and very high-power short-duration ablation for atrial fibrillation treatment: The peQasus multicentre study. Europace. 2025;27(6):euae284.","journal-title":"Europace"},{"key":"2330_CR12","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1016\/j.jacep.2017.11.018","volume":"4","author":"E Leshem","year":"2018","unstructured":"Leshem E, Zilberman I, Tschabrunn CM, Barkagan M, Contreras-Valdes FM, Govari A, Anter E. High-power and short-duration ablation for pulmonary vein isolation: Biophysical characterization. JACC Clin Electrophysiol. 2018;4:467\u201379.","journal-title":"JACC Clin Electrophysiol"},{"key":"2330_CR13","doi-asserted-by":"publisher","first-page":"1287","DOI":"10.1111\/jce.13651","volume":"29","author":"M Barkagan","year":"2018","unstructured":"Barkagan M, Contreras-Valdes FM, Leshem E, Buxton AE, Nakagawa H, Anter E. High-power and short-duration ablation for pulmonary vein isolation: Safety, efficacy, and long-term durability. J Cardiovasc Electrophysiol. 2018;29:1287\u201396.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2330_CR14","doi-asserted-by":"publisher","first-page":"1717","DOI":"10.1111\/pace.14358","volume":"44","author":"G Stabile","year":"2021","unstructured":"Stabile G, Schillaci V, Strisciuglio T, Arestia A, Agresta A, Shopova G, et al. In vivo biophysical characterization of very high-power, short-duration, temperature-controlled lesions. Pacing Clin Electrophysiol. 2021;44:1717\u201323.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"1","key":"2330_CR15","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1007\/s10840-022-01197-x","volume":"65","author":"V Schillaci","year":"2022","unstructured":"Schillaci V, Strisciuglio T, Stabile G, Salito A, Arestia A, Agresta A, et al. Cavotricuspid isthmus ablation using very high-power, short-duration, temperature-controlled lesions. J Interv Card Electrophysiol. 2022;65(1):97\u2013102.","journal-title":"J Interv Card Electrophysiol"},{"issue":"2","key":"2330_CR16","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1007\/s12181-023-00658-5","volume":"18","author":"RR Tilz","year":"2024","unstructured":"Tilz RR, Busch S, Chun KRJ, Frerker C, Gaede L, Steven D, et al. Analgosedierung der Kardiologie Die Kardiologie. 2024;18(2):187\u201399.","journal-title":"Analgosedierung der Kardiologie Die Kardiologie"},{"key":"2330_CR17","doi-asserted-by":"publisher","first-page":"1186","DOI":"10.1111\/j.1540-8167.1998.tb00091.x","volume":"9","author":"JA Cabrera","year":"1998","unstructured":"Cabrera JA, Sanchez-Quintana D, Ho SY, Medina A, Anderson RH. The architecture of the atrial musculature between the orifice of the inferior caval vein and the tricuspid valve: The anatomy of the isthmus. J Cardiovasc Electrophysiol. 1998;9:1186\u201395.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2330_CR18","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1007\/s10840-007-9159-0","volume":"20","author":"S Knecht","year":"2007","unstructured":"Knecht S, Castro-Rodriguez J, Verbeet T, et al. Multidetector 16-slice CT scan evaluation of cavotricuspid isthmus anatomy before radiofrequency ablation. J Interv Card Electrophysiol. 2007;20:29\u201335.","journal-title":"J Interv Card Electrophysiol"},{"issue":"1","key":"2330_CR19","doi-asserted-by":"publisher","first-page":"e13192","DOI":"10.1002\/joa3.13192","volume":"41","author":"Y Hanaki","year":"2024","unstructured":"Hanaki Y, Komatsu Y, Iioka Y, Ishizu T, Nogami A. Ex vivo lesion formation with two adjacent very high-power short-duration radiofrequency applications at varying inter-lesion times. J Arrhythm. 2024;41(1):e13192.","journal-title":"J Arrhythm"},{"issue":"9","key":"2330_CR20","doi-asserted-by":"publisher","first-page":"2331","DOI":"10.1016\/j.hrthm.2024.10.026","volume":"22","author":"J Yamaguchi","year":"2025","unstructured":"Yamaguchi J, et al. Feasibility and safety assessment of radiofrequency double applications in very high-power short-duration ablation. Heart Rhythm. 2025;22(9):2331\u20139.","journal-title":"Heart Rhythm"},{"issue":"11","key":"2330_CR21","doi-asserted-by":"publisher","first-page":"euad310","DOI":"10.1093\/europace\/euad310","volume":"25","author":"AA Bortone","year":"2023","unstructured":"Bortone AA, Ramirez FD, Constantin M, Bortone C, H\u00e9bert C, Constantin J, et al. Optimal interlesion distance for 90- and 50-W radiofrequency applications with low ablation index values: Experimental findings in a chronic ovine model. Europace. 2023;25(11):euad310.","journal-title":"Europace"},{"key":"2330_CR22","doi-asserted-by":"crossref","unstructured":"Iwakawa, H., Takigawa, M., Nakada, K., Yamamoto, T., Ikenouchi, T., Masumura, M.,\u2026 Sasano, T. (2025). Efficacy and safety of high-power short\u2010duration ablation for cavo\u2010tricuspid isthmus with a flexible\u2010tip temperature\u2010controlled power regulation catheter performed by electrophysiology trainees. J Interv Card Electrophysiol. 2025;36(2),367\u2013375.","DOI":"10.1111\/jce.16516"},{"key":"2330_CR23","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1007\/s10840-024-01969-7","volume":"68","author":"LV Soria","year":"2025","unstructured":"Soria LV, Toquero J, Brouzet T, Cano LG, Barrios AG, Dominguez MS, et al. Very high\u2013power short\u2013duration radiofrequency ablation in patientswith typical atrial flutter: rationale and design of the FASD\u2013HPrandomized trial. J Interv Card Electrophysiol. 2025;68:497\u2013503.","journal-title":"J Interv Card Electrophysiol"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-026-02330-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-026-02330-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-026-02330-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T22:03:48Z","timestamp":1793916228000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-026-02330-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,18]]},"references-count":23,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2026,11]]}},"alternative-id":["2330"],"URL":"https:\/\/doi.org\/10.1007\/s10840-026-02330-w","relation":{},"ISSN":["1572-8595"],"issn-type":[{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,18]]},"assertion":[{"value":"25 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Competing interests statement: BK reports travel and congress support from EHRA, DGK, and Pfizer related to this work, and speaker honoraria from Biotronik, Impulse Dynamics, C.T.I. GmbH, and Doctrina Med outside the submitted work.MB declares no competing interests.CHH reports travel and research grants from Boston Scientific, LifeTech, Biosense Webster, and Haemonetics, and speaker honoraria from Boston Scientific, Biosense Webster, Pfizer, Haemonetics, BMS, C.T.I. GmbH, Doctrina Med, and EHRA.RRT reports speaker honoraria from Pfizer, Abbott, Biosense Webster, Boston Scientific, Doctrina Med, cme4u, Medtronic, Radcliffe, and Wikonect; consulting\/advisory roles for Boston Scientific, Biosense Webster, Capvision, Guidepoint, Haemonetics, Medtronic, Philips, and Abbott; institutional research support from Biotronik, Abbott, Boston Scientific, Medtronic, Lifetech, and J&J; and travel support from Biosense Webster, Abbott, Boston Scientific, Medtronic, and Philips.CE reports research and travel grants and speaker honoraria from Abbott, Boston Scientific, Lifetech, Biosense Webster, Cardiofocus, C.T.I. GmbH, and Doctrina Med.SH reports travel and educational grants from Abbott and J&J.JPW reports funding from the German Foundation of Heart Research (F\/29\/19), speaker honoraria from Abbott and Doctrina Med, and travel support from Boston Scientific, all outside the submitted work.TA\u00d6 reports congress grants from EHRA outside the submitted work.The authors declare that these interests did not influence the design, conduct, analysis, or reporting of this study.Funding: None.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"To ensure clear and uniform usage of proper English language ChatGPT has been used. Parts of the graphical abstract were generated using SciDraw. The output has been reviewed and edited as needed. The authors take full responsibility for the content of the publication.","order":2,"name":"Ethics","label":"Statement on usage of artifical intelligence","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Read & discuss about #vHPSD #90W4s for #CTI ablation.","order":3,"name":"Ethics","label":"Tweet","group":{"name":"EthicsHeading","label":"Declarations"}}]}}