{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T22:26:56Z","timestamp":1793917616498,"version":"4.8.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T00:00:00Z","timestamp":1779321600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T00:00:00Z","timestamp":1779321600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Intracardiac echocardiography (ICE) is commonly used during atrial fibrillation (AF) ablation to facilitate transseptal access, catheter positioning, and intraprocedural safety monitoring but adds procedural cost and requires additional vascular access. Real-time three-dimensional transesophageal echocardiography (3D TEE) offers high-quality imaging without disposable intravascular catheters; however, its use as a primary intraprocedural imaging modality during contemporary AF ablation has been limited. This study evaluated the feasibility, safety, and procedural efficiency of using real-time 3D TEE in place of ICE for intraprocedural guidance during AF ablation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This single-center feasibility study included 128 consecutive AF ablation procedures performed over an eight-month pilot period using real-time 3D TEE as the primary intraprocedural imaging modality. TEE was used for transseptal puncture guidance, catheter visualization, and intraprocedural safety monitoring. Procedural characteristics, fluoroscopy utilization, acute procedural success, complications, and same-day discharge rates were analyzed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Acute procedural ablation success was achieved in all cases. Procedures included de novo and repeat ablations, cases requiring lesion sets beyond pulmonary vein isolation, and concomitant left atrial appendage occlusion. No major acute complications, including pericardial effusion requiring intervention, clinically apparent esophageal injury, cerebrovascular events, or in-hospital mortality, were observed. Median total procedure time was 40\u00a0min (interquartile range (IQR) 32\u201350), median fluoroscopy time was 8.6\u00a0min (IQR 6.2\u201311.0), and median radiation dose was 39.1 mGy (IQR 23.2\u201378.9). Same-day discharge was achieved in 87.5% of procedures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Real-time 3D TEE can be used as the primary intraprocedural imaging modality for AF ablation, providing effective guidance for transseptal access, catheter positioning, and safety monitoring without reliance on ICE. In centers with advanced echocardiographic expertise and appropriate training frameworks, this approach may represent a viable alternative to ICE with potential advantages in procedural workflow and resource utilization.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Capsule Summary<\/jats:title>\n                    <jats:p>Real-time three-dimensional transesophageal echocardiography can be used as the primary intraprocedural imaging modality during atrial fibrillation ablation, providing effective guidance for catheter manipulation and safety monitoring while avoiding disposable intracardiac echocardiography catheters and additional vascular access.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s10840-026-02355-1","type":"journal-article","created":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T07:59:00Z","timestamp":1779350340000},"page":"2479-2489","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Atrial fibrillation ablation using real-time three-dimensional transesophageal echocardiography as the primary intraprocedural imaging modality: a single-center feasibility study"],"prefix":"10.1007","volume":"69","author":[{"given":"Casey","family":"Willaford","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Malcolm","family":"Woollett","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ian","family":"Woollett","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,21]]},"reference":[{"issue":"10","key":"2355_CR1","doi-asserted-by":"publisher","first-page":"e275","DOI":"10.1016\/j.hrthm.2017.05.012","volume":"14","author":"H Calkins","year":"2017","unstructured":"Calkins H, Hindricks G, Cappato R, Kim YH, Saad EB, Aguinaga L, et al. 2017 HRS\/EHRA\/ECAS\/APHRS\/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. Heart Rhythm. 2017;14(10):e275\u2013444. https:\/\/doi.org\/10.1016\/j.hrthm.2017.05.012.","journal-title":"Heart Rhythm"},{"issue":"6","key":"2355_CR2","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1111\/pace.12030","volume":"36","author":"CP Ruisi","year":"2013","unstructured":"Ruisi CP, Brysiewicz N, Asnes JD, Sugeng L, Marieb M, Clancy J, et al. Use of intracardiac echocardiography during atrial fibrillation ablation. Pacing Clin Electrophysiol. 2013;36(6):781\u20138. https:\/\/doi.org\/10.1111\/pace.12030.","journal-title":"Pacing Clin Electrophysiol"},{"key":"2355_CR3","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1007\/s10840-020-00844-5","volume":"61","author":"A Isath","year":"2021","unstructured":"Isath A, Padmanabhan D, Haider SW, Siroky G, Perimbeti S, Correa A, et al. Does the use of intracardiac echocardiography during atrial fibrillation catheter ablation improve outcomes and cost? A nationwide 14-year analysis from 2001 to 2014. J Interv Card Electrophysiol. 2021;61:461\u20138. https:\/\/doi.org\/10.1007\/s10840-020-00844-5.","journal-title":"J Interv Card Electrophysiol"},{"issue":"3","key":"2355_CR4","doi-asserted-by":"publisher","first-page":"664","DOI":"10.1111\/jce.14367","volume":"31","author":"M Goya","year":"2020","unstructured":"Goya M, Frame D, Gache L, Ichishima Y, Tayar DO, Goldstein L, et al. The use of intracardiac echocardiography catheters in endocardial ablation of cardiac arrhythmia: meta-analysis of efficiency, effectiveness, and safety outcomes. J Cardiovasc Electrophysiol. 2020;31(3):664\u201373. https:\/\/doi.org\/10.1111\/jce.14367.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"6","key":"2355_CR5","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1161\/CIRCEP.110.936161","volume":"3","author":"S Saksena","year":"2010","unstructured":"Saksena S, Sra J, Jordaens L, Kusumoto F, Knight BP, Natale A, et al. A prospective comparison of cardiac imaging using intracardiac echocardiography with transesophageal echocardiography in patients with atrial fibrillation: the ICE-CHIP study. Circ Arrhythm Electrophysiol. 2010;3(6):571\u20137. https:\/\/doi.org\/10.1161\/CIRCEP.110.936161.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2355_CR6","doi-asserted-by":"publisher","first-page":"921746","DOI":"10.1155\/2012\/921746","volume":"2012","author":"J Biermann","year":"2012","unstructured":"Biermann J, Horstkotte D. Intracardiac echocardiography during catheter-based ablation of atrial fibrillation. Cardiol Res Pract. 2012;2012:921746. https:\/\/doi.org\/10.1155\/2012\/921746.","journal-title":"Cardiol Res Pract"},{"issue":"9","key":"2355_CR7","doi-asserted-by":"publisher","first-page":"1333","DOI":"10.1093\/europace\/eut083","volume":"15","author":"L Pison","year":"2013","unstructured":"Pison L, van Huls CFB, de Groot N, Zeppenfeld K, Bax JJ, Duytschaever M, et al. Imaging techniques in electrophysiology and implantable device procedures: results of the European Heart Rhythm Association survey (EP Wire). Europace. 2013;15(9):1333\u201340. https:\/\/doi.org\/10.1093\/europace\/eut083.","journal-title":"Europace"},{"issue":"2","key":"2355_CR8","doi-asserted-by":"publisher","first-page":"euag002","DOI":"10.1093\/europace\/euag002","volume":"28","author":"P Karakasis","year":"2026","unstructured":"Karakasis P, Tzeis S, Pamporis K, Vlachos K, Siontis KC, Antoniadis AP, et al. Safety and efficacy of intracardiac echocardiography in atrial fibrillation ablation: a meta-analysis. Europace. 2026;28(2):euag002. https:\/\/doi.org\/10.1093\/europace\/euag002.","journal-title":"Europace"},{"issue":"1","key":"2355_CR9","doi-asserted-by":"publisher","first-page":"e106","DOI":"10.1016\/j.hrthm.2025.09.019","volume":"23","author":"AJ Shanker","year":"2026","unstructured":"Shanker AJ, Jones SO, Aryana A, Blankenship JC, Cheung JW, Hurwitz JL, et al. HRS\/ACC scientific statement: guiding principles on the performance of intracardiac ablation procedures in ambulatory surgical centers. Heart Rhythm. 2026;23(1):e106\u201322. https:\/\/doi.org\/10.1016\/j.hrthm.2025.09.019.","journal-title":"Heart Rhythm"},{"issue":"3","key":"2355_CR10","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1016\/j.joa.2015.12.005","volume":"32","author":"\u0130 Erden","year":"2016","unstructured":"Erden \u0130, Erden E\u00c7, Golcuk E, Aksu T, Yalin K, G\u00fcler TE, \u00d6zcan KS, Turan B. Impact of transesophageal echocardiography during transseptal puncture on atrial fibrillation ablation. J Arrhythm. 2016;32(3):170\u20135. https:\/\/doi.org\/10.1016\/j.joa.2015.12.005.","journal-title":"J Arrhythm"},{"issue":"4","key":"2355_CR11","doi-asserted-by":"publisher","first-page":"456","DOI":"10.1016\/j.jcmg.2011.10.009","volume":"5","author":"FF Faletra","year":"2012","unstructured":"Faletra FF, Nucifora G, Regoli F, Ho SY, Moccetti T, Auricchio A. Anatomy of pulmonary veins by real-time three-dimensional transesophageal echocardiography: implications for catheter-based pulmonary vein ablation. JACC Cardiovasc Imaging. 2012;5(4):456\u201362. https:\/\/doi.org\/10.1016\/j.jcmg.2011.10.009.","journal-title":"JACC Cardiovasc Imaging"},{"issue":"1","key":"2355_CR12","doi-asserted-by":"publisher","first-page":"e003172","DOI":"10.1136\/openhrt-2025-003172","volume":"12","author":"J Liu","year":"2025","unstructured":"Liu J, Tang M, Niu G, Li C, Zhang D, Jiang Y, et al. Initial experience of transoesophageal echocardiography-guided percutaneous pulsed field ablation of atrial fibrillation. Open Heart. 2025;12(1):e003172. https:\/\/doi.org\/10.1136\/openhrt-2025-003172.","journal-title":"Open Heart"},{"issue":"11","key":"2355_CR13","doi-asserted-by":"publisher","first-page":"1241","DOI":"10.1016\/j.hlc.2025.04.088","volume":"34","author":"Y Zhou","year":"2025","unstructured":"Zhou Y, Tan WK, Thomas SP, Qian PC. A fluoroless workflow using transoesophageal echocardiography for catheter ablation of atrial fibrillation using pulsed field ablation. Heart Lung Circ. 2025;34(11):1241\u20139. https:\/\/doi.org\/10.1016\/j.hlc.2025.04.088.","journal-title":"Heart Lung Circ"},{"issue":"2","key":"2355_CR14","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/j.jbi.2008.08.010","volume":"42","author":"PA Harris","year":"2009","unstructured":"Harris PA, Taylor R, Thielke R, Payne J, Gonzalez N, Conde JG. Research electronic data capture (REDCap)\u2014a metadata-driven methodology and workflow process for providing translational research informatics support. J Biomed Inf. 2009;42(2):377\u201381. https:\/\/doi.org\/10.1016\/j.jbi.2008.08.010.","journal-title":"J Biomed Inf"},{"key":"2355_CR15","doi-asserted-by":"publisher","first-page":"103208","DOI":"10.1016\/j.jbi.2019.103208","volume":"95","author":"PA Harris","year":"2019","unstructured":"Harris PA, Taylor R, Minor BL, Elliott V, Fernandez M, O\u2019Neal L, et al. The REDCap consortium: Building an international community of software platform partners. J Biomed Inf. 2019;95:103208. https:\/\/doi.org\/10.1016\/j.jbi.2019.103208.","journal-title":"J Biomed Inf"},{"issue":"8","key":"2355_CR16","doi-asserted-by":"publisher","first-page":"1757","DOI":"10.1016\/j.jacep.2025.04.015","volume":"11","author":"G Vetta","year":"2025","unstructured":"Vetta G, Della Rocca DG, Magnocavallo M, Richard-Vitton R, Almorad A, Betancur A, et al. Efficacy and drug-related complications of anticholinergic drugs for vagal reaction prevention during pulsed field ablation. JACC Clin Electrophysiol. 2025;11(8):1757\u201368. https:\/\/doi.org\/10.1016\/j.jacep.2025.04.015.","journal-title":"JACC Clin Electrophysiol"},{"issue":"5","key":"2355_CR17","doi-asserted-by":"publisher","first-page":"834","DOI":"10.1093\/europace\/euaa359","volume":"23","author":"E Bertaglia","year":"2021","unstructured":"Bertaglia E, Stabile G, De Simone A, et al. Three-dimensional intracardiac echocardiography for guidance of atrial fibrillation ablation procedures. Europace. 2021;23(5):834\u201342. https:\/\/doi.org\/10.1093\/europace\/euaa359.","journal-title":"Europace"},{"key":"2355_CR18","doi-asserted-by":"publisher","first-page":"1180299","DOI":"10.3389\/fcvm.2023.1180299","volume":"10","author":"EC Ho","year":"2023","unstructured":"Ho EC, Assafin M, Sugiura T, Granada JF, Chau M, Latib A. 3-dimensional intracardiac echocardiography for structural heart interventions. Front Cardiovasc Med. 2023;10:1180299. https:\/\/doi.org\/10.3389\/fcvm.2023.1180299.","journal-title":"Front Cardiovasc Med"},{"issue":"1","key":"2355_CR19","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1161\/CIRCULATIONAHA.123.064959","volume":"148","author":"MK Turagam","year":"2023","unstructured":"Turagam MK, Neuzil P, Schmidt B, Reichlin T, Neven K, Blaauw Y, et al. Safety and effectiveness of pulsed field ablation to treat atrial fibrillation: one-year outcomes from the MANIFEST-PF Registry. Circulation. 2023;148(1):35\u201346. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.123.064959.","journal-title":"Circulation"},{"issue":"7","key":"2355_CR20","doi-asserted-by":"publisher","first-page":"euad185","DOI":"10.1093\/europace\/euad185","volume":"25","author":"B Schmidt","year":"2023","unstructured":"Schmidt B, Bordignon S, Neven K, Reichlin T, Blaauw Y, Hansen J, et al. European real-world outcomes with pulsed field ablation in patients with symptomatic atrial fibrillation: lessons from the multi-centre EU-PORIA registry. Europace. 2023;25(7):euad185. https:\/\/doi.org\/10.1093\/europace\/euad185.","journal-title":"Europace"},{"issue":"12","key":"2355_CR21","doi-asserted-by":"publisher","first-page":"1249","DOI":"10.1001\/jamacardio.2025.3687","volume":"10","author":"X Hu","year":"2025","unstructured":"Hu X, Jiang W, Wang X, Ye P, Li X, Wang Y, et al. Intracardiac vs transesophageal echocardiography in atrial fibrillation ablation: a randomized clinical trial. JAMA Cardiol. 2025;10(12):1249\u201356. https:\/\/doi.org\/10.1001\/jamacardio.2025.3687.","journal-title":"JAMA Cardiol"},{"issue":"5","key":"2355_CR22","first-page":"567","volume":"53","author":"SK Mathur","year":"2009","unstructured":"Mathur SK, Singh P. Transesophageal echocardiography-related complications. Indian J Anaesth. 2009;53(5):567\u201374.","journal-title":"Indian J Anaesth"},{"key":"2355_CR23","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1016\/j.ahj.2019.11.018","volume":"221","author":"AB Freitas-Ferraz","year":"2020","unstructured":"Freitas-Ferraz AB, Rod\u00e9s-Cabau J, Junquera Vega L, Beaudoin J, O\u2019Connor K, Turgeon PY, et al. Transesophageal echocardiography complications associated with interventional cardiology procedures. Am Heart J. 2020;221:19\u201328. https:\/\/doi.org\/10.1016\/j.ahj.2019.11.018.","journal-title":"Am Heart J"},{"issue":"9","key":"2355_CR24","doi-asserted-by":"publisher","first-page":"925","DOI":"10.1016\/j.echo.2005.01.034","volume":"18","author":"JK Min","year":"2005","unstructured":"Min JK, Spencer KT, Furlong KT, DeCara JM, Sugeng L, Ward RP, et al. Clinical features of complications from transesophageal echocardiography: a single-center case series of 10 000 consecutive examinations. J Am Soc Echocardiogr. 2005;18(9):925\u20139. https:\/\/doi.org\/10.1016\/j.echo.2005.01.034.","journal-title":"J Am Soc Echocardiogr"},{"issue":"6","key":"2355_CR25","doi-asserted-by":"publisher","first-page":"894","DOI":"10.1002\/joa3.12950","volume":"39","author":"T Koyama","year":"2023","unstructured":"Koyama T, Tobita K, Kawaguchi T, Uchida S, Koyama E, Kodera N, et al. Incidence, clinical course, and risk factors for femoral pseudoaneurysm after atrial fibrillation ablation. J Arrhythm. 2023;39(6):894\u2013900. https:\/\/doi.org\/10.1002\/joa3.12950.","journal-title":"J Arrhythm"},{"issue":"21","key":"2355_CR26","doi-asserted-by":"publisher","first-page":"2089","DOI":"10.1016\/j.jacc.2023.03.418","volume":"81","author":"K Benali","year":"2023","unstructured":"Benali K, Khairy P, Hammache N, Petzl A, Da Costa A, Verma A, et al. Procedure-related complications of catheter ablation for atrial fibrillation: a systematic review and pooled analysis. J Am Coll Cardiol. 2023;81(21):2089\u201399. https:\/\/doi.org\/10.1016\/j.jacc.2023.03.418.","journal-title":"J Am Coll Cardiol"},{"issue":"23","key":"2355_CR27","doi-asserted-by":"publisher","first-page":"2875","DOI":"10.1016\/j.jacc.2021.04.036","volume":"77","author":"A Lurie","year":"2021","unstructured":"Lurie A, Wang J, Hinnegan KJ, McIntyre WF, Belley-C\u00f4t\u00e9 EP, Amit G, et al. Prevalence of left atrial thrombus in anticoagulated patients with atrial fibrillation. J Am Coll Cardiol. 2021;77(23):2875\u201386. https:\/\/doi.org\/10.1016\/j.jacc.2021.04.036.","journal-title":"J Am Coll Cardiol"},{"issue":"12","key":"2355_CR28","doi-asserted-by":"publisher","first-page":"936","DOI":"10.1016\/j.hroo.2024.10.004","volume":"5","author":"AJ Quiroz Alfaro","year":"2024","unstructured":"Quiroz Alfaro AJ, Russell NE, Munshi R, Hassan W, Stone JE, Abdelrahim EM, et al. Percutaneous left atrial appendage closure using a modified single-operator\u2013technician approach under deep sedation: a single-center experience. Heart Rhythm O2. 2024;5(12):936\u201341. https:\/\/doi.org\/10.1016\/j.hroo.2024.10.004.","journal-title":"Heart Rhythm O2"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-026-02355-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-026-02355-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-026-02355-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T22:05:38Z","timestamp":1793916338000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-026-02355-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,21]]},"references-count":28,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2026,11]]}},"alternative-id":["2355"],"URL":"https:\/\/doi.org\/10.1007\/s10840-026-02355-1","relation":{},"ISSN":["1572-8595"],"issn-type":[{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,21]]},"assertion":[{"value":"12 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 August 2026","order":5,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":6,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The reference 11 in this paper has been updated to reflect the correct information.","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}