{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T04:58:15Z","timestamp":1794027495814,"version":"4.8.0"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T00:00:00Z","timestamp":1779408000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T00:00:00Z","timestamp":1779408000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Achieving adequate lesion depth during ventricular tachycardia (VT) ablation within scar is challenging with conventional radiofrequency energy (RF). The lattice-tip catheter enables dual-energy ablation (RF &amp; pulsed field [PF]) with enhanced tissue penetration.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>We report on 3 cardiac implantable electronic device (CIED) patients with transmural apical left ventricular (LV) scars and drug-refractory VT. Each underwent endocardial LV ablation using RF &amp; stacked PF. Ablation included delivery near the opposing surface of CIED leads, at sites critical for the VT circuit. CIED parameters were assessed pre- and post-procedure, as well as at interval follow-up.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>VT was eliminated with complete non-inducibility achieved in all cases, and there has been no recurrence at early follow-up (4-6months). However, each case demonstrated inadvertent CIED lead capture threshold rise (apical right ventricular x2, anterolateral LV coronary sinus branch x1), with partial recovery over time. Findings correlated with ablation near opposing lead electrodes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Dual-energy lattice-tip ablation creates effective ventricular lesions through transmural scar that may increase CIED capture thresholds on the opposing myocardial surface. Our report recommends vigilance during ablation opposing CIED leads, balancing the respective wall thickness and potential for lead damage against the gravity of the arrhythmic presentation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s10840-026-02356-0","type":"journal-article","created":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T02:24:18Z","timestamp":1779416658000},"page":"1967-1973","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Lattice-tip dual energy ablation creates effective ventricular lesions through transmural scar that might inadvertently increase lead capture thresholds on the opposing surface"],"prefix":"10.1007","volume":"69","author":[{"given":"Vishal","family":"Luther","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura","family":"Brodie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Justin","family":"Chiong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Calvert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Walker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dhiraj","family":"Gupta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nathan","family":"Denham","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,22]]},"reference":[{"issue":"3","key":"2356_CR1","doi-asserted-by":"publisher","first-page":"e000072","DOI":"10.1161\/JAHA.113.000072","volume":"2","author":"M Tokuda","year":"2013","unstructured":"Tokuda M, Kojodjojo P, Tung S, Tedrow UB, Nof E, Inada K, et al. Acute failure of catheter ablation for ventricular tachycardia due to structural heart disease: causes and significance. J Am Heart Assoc. 2013;2(3):e000072. https:\/\/doi.org\/10.1161\/JAHA.113.000072.","journal-title":"J Am Heart Assoc"},{"issue":"11","key":"2356_CR2","doi-asserted-by":"publisher","first-page":"e007661","DOI":"10.1161\/CIRCEP.119.007661","volume":"12","author":"A Shapira-Daniels","year":"2019","unstructured":"Shapira-Daniels A, Barkagan M, Yavin H, Sroubek J, Reddy VY, Neuzil P, et al. Novel Irrigated Temperature-Controlled Lattice Ablation Catheter for Ventricular Ablation: A Preclinical Multimodality Biophysical Characterization. Circ Arrhythm Electrophysiol. 2019;12(11):e007661. https:\/\/doi.org\/10.1161\/CIRCEP.119.007661.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2356_CR3","doi-asserted-by":"publisher","unstructured":"Verma A, Maffre J, Sharma T, Farshchi-Heydari S. Effect of sequential, colocalized radiofrequency and pulsed field ablation on cardiac lesion size and histology. Circ Arrhythm Electrophysiol. 2025;18(2). https:\/\/doi.org\/10.1161\/CIRCEP.124.013143.","DOI":"10.1161\/CIRCEP.124.013143"},{"issue":"2","key":"2356_CR4","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1016\/j.jacep.2023.09.015","volume":"10","author":"A Younis","year":"2024","unstructured":"Younis A, Buck E, Santangeli P, Tabaja C, Garrott K, Lehn L, et al. Efficacy of Pulsed Field vs Radiofrequency for the Reablation of Chronic Radiofrequency Ablation Substrate. JACC Clin Electrophysiol. 2024;10(2):222\u201334. https:\/\/doi.org\/10.1016\/j.jacep.2023.09.015.","journal-title":"JACC Clin Electrophysiol"},{"issue":"9","key":"2356_CR5","doi-asserted-by":"publisher","first-page":"e010375","DOI":"10.1161\/CIRCEP.121.010375","volume":"14","author":"HD Yavin","year":"2021","unstructured":"Yavin HD, Higuchi K, Sroubek J, Younis A, Zilberman I, Anter E. Pulsed-Field Ablation in Ventricular Myocardium Using a Focal Catheter: The Impact of Application Repetition on Lesion Dimensions. Circ Arrhythm Electrophysiol. 2021;14(9):e010375. https:\/\/doi.org\/10.1161\/CIRCEP.121.010375.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"11","key":"2356_CR6","doi-asserted-by":"publisher","first-page":"euae275","DOI":"10.1093\/europace\/euae","volume":"26","author":"P Peichl","year":"2024","unstructured":"Peichl P, Wichterle D, Schlosser F, Stojadinovi\u0107 P, Nejedlo V, Bori\u0161incov\u00e1 E, et al. Mapping and ablation of ventricular tachycardia using dual-energy lattice-tip focal catheter: early feasibility and safety study. Europace. 2024;26(11):euae275. https:\/\/doi.org\/10.1093\/europace\/euae275.","journal-title":"Europace"},{"issue":"9","key":"2356_CR7","doi-asserted-by":"publisher","first-page":"euaf139","DOI":"10.1093\/europace\/euaf","volume":"27","author":"F Sacher","year":"2025","unstructured":"Sacher F, Sarkozy A, P\u00fcrerfellner H, Steyer A, Lyne J, Coquard C, et al. Safety and efficacy of a lattice-tip catheter for ventricular arrhythmia ablation: the AFFERA Ventricular Arrhythmia Ablation Registry (AVAAR). Europace. 2025;27(9):euaf139. https:\/\/doi.org\/10.1093\/europace\/euaf139.","journal-title":"Europace"},{"key":"2356_CR8","doi-asserted-by":"publisher","unstructured":"Sison S, Ellenbogen KA, Swerdlow CD. Adverse events during catheter ablation in patients with cardiac implantable electronic devices. Heart Rhythm. 2026;S1547-5271(26)00126-8. https:\/\/doi.org\/10.1016\/j.hrthm.2026.02.008.","DOI":"10.1016\/j.hrthm.2026.02.008"},{"key":"2356_CR9","doi-asserted-by":"publisher","first-page":"e16","DOI":"10.15420\/aer.2024.26","volume":"13","author":"MT Mills","year":"2024","unstructured":"Mills MT, Calvert P, Chiong J, Gupta D, Luther V. Dynamic Voltage Mapping of the Post-infarct Ventricular Tachycardia Substrate: A Practical Technique to Help Differentiate Scar from Borderzone Tissue. Arrhythmia Electrophysiol Rev. 2024;13:e16. https:\/\/doi.org\/10.15420\/aer.2024.26.","journal-title":"Arrhythmia Electrophysiol Rev"},{"key":"2356_CR10","doi-asserted-by":"publisher","unstructured":"Koruth JS, Maher TR, Reddy VY, Siontis KC, Shinohara M, Watanabe K, et al. Steam pops during temperature-controlled irrigated radiofrequency ablation using the lattice-tip catheter. Heart Rhythm. 2025;S154752712503139X. https:\/\/doi.org\/10.1016\/j.hrthm.2025.12.006.","DOI":"10.1016\/j.hrthm.2025.12.006"},{"issue":"10","key":"2356_CR11","doi-asserted-by":"publisher","first-page":"e012992","DOI":"10.1161\/CIRCEP.124.012992","volume":"17","author":"J Aguilera","year":"2024","unstructured":"Aguilera J, Obeng-Gyimah E, Kuramochi Y, Chung R, Cochet H, Christie M, et al. Elimination of Epicardial Scar-Related Ventricular Tachycardia With Endocardial Pulsed Field Ablation: First Clinical Report. Circ Arrhythm Electrophysiol. 2024;17(10):e012992. https:\/\/doi.org\/10.1161\/CIRCEP.124.012992.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2356_CR12","doi-asserted-by":"publisher","unstructured":"Kovacs B, Spahiu V, Kueffer T, Haeberlin A, Roten L, Reichlin T. Inadvertent ventricular fibrillation induced by radiofrequency ablation with the lattice-tip catheter in proximity to implantable cardioverter-defibrillator leads. Heart Rhythm. 2025;S1547527125030127. https:\/\/doi.org\/10.1016\/j.hrthm.2025.10.031.","DOI":"10.1016\/j.hrthm.2025.10.031"},{"key":"2356_CR13","doi-asserted-by":"publisher","unstructured":"Malyar CV, Mahmoodi BK, Yap SC. Ventricular fibrillation triggered by cavotricuspid isthmus radiofrequency ablation with a dual-energy lattice-tip catheter in a patient with an implantable cardioverter-defibrillator. Hear Case Rep. 2025;S2214027125003616. https:\/\/doi.org\/10.1016\/j.hrcr.2025.11.004.","DOI":"10.1016\/j.hrcr.2025.11.004"},{"key":"2356_CR14","doi-asserted-by":"publisher","unstructured":"Schaerli N, Spreen D, Knecht S, Krisai P, K\u00fchne M, Sticherling C, et al. Unexpected ventricular fibrillation during left ventricular lattice-tip radiofrequency ablation in a patient with an ICD. Heart Rhythm. 2025;S1547527125031303. https:\/\/doi.org\/10.1016\/j.hrthm.2025.11.046.","DOI":"10.1016\/j.hrthm.2025.11.046"},{"issue":"25","key":"2356_CR15","doi-asserted-by":"publisher","first-page":"02920","DOI":"10.1016\/j.hrthm","volume":"S1547\u20135271","author":"DG Nair","year":"2025","unstructured":"Nair DG, Gabrah K, Doty B, Nair G, Reddy VY. Cardiac implantable electronic device software reset and damage after pulsed field ablation using a monopolar lattice-tip catheter. Heart Rhythm. 2025;S1547\u20135271(25):02920\u20130. https:\/\/doi.org\/10.1016\/j.hrthm.2025.09.027.","journal-title":"Heart Rhythm"},{"key":"2356_CR16","doi-asserted-by":"publisher","unstructured":"Malyar CV, Kovacs B, Mahmoodi BK, Haeberlin A, Reichlin T, Yap SC. Permanent damage to implantable cardioverter-defibrillators during left-sided septal ventricular tachycardia ablation using a lattice-tip catheter: a case series. Heart Rhythm. 2026;S1547527126000470. https:\/\/doi.org\/10.1016\/j.hrthm.2026.01.028.","DOI":"10.1016\/j.hrthm.2026.01.028"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-026-02356-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-026-02356-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-026-02356-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T08:54:49Z","timestamp":1792572889000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-026-02356-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,22]]},"references-count":16,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2026,10]]}},"alternative-id":["2356"],"URL":"https:\/\/doi.org\/10.1007\/s10840-026-02356-0","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-9509205\/v1","asserted-by":"object"}]},"ISSN":["1572-8595"],"issn-type":[{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,22]]},"assertion":[{"value":"23 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Dr Luther receives honoraria from J&J Med-Tech, Boston Scientific, Medtronic and institutional research grant from J&J Med-Tech. Prof Gupta receives institutional research grants from J&J MedTech, Boston Scientific and Medtronic, and speaker fees from Boston Scientific. The other authors report no conflicts of interest.","order":1,"name":"Ethics","label":"Disclosures","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}