{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T08:25:08Z","timestamp":1787127908300,"version":"build-2736575974"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T00:00:00Z","timestamp":1787097600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T00:00:00Z","timestamp":1787097600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Science Foundation of Tianjin Binhai New Area Health Commission","award":["2023BWKQ012"],"award-info":[{"award-number":["2023BWKQ012"]}]},{"name":"Tianjin Key Medical Discipline Construction Project","award":["TJYXZDXK-3-035C"],"award-info":[{"award-number":["TJYXZDXK-3-035C"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"DOI":"10.1007\/s10840-026-02417-4","type":"journal-article","created":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T07:34:36Z","timestamp":1787124876000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Safety and feasibility of a balloon-based pulsed field ablation system for the catheter ablation of paroxysmal atrial fibrillation"],"prefix":"10.1007","author":[{"given":"Peize","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kun","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinlong","family":"Bai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiuhong","family":"Dong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuai","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lichao","family":"Tian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhaoqian","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhi","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuhao","family":"Miao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jingjing","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,19]]},"reference":[{"issue":"1","key":"2417_CR1","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1161\/CIR.0000000000001193","volume":"149","author":"JA Joglar","year":"2024","unstructured":"Joglar JA, Chung MK, Armbruster AL, et al. 2023 ACC\/AHA\/ACCP\/HRS Guideline for the diagnosis and management of atrial fibrillation: a report of the american college of cardiology\/American heart association joint committee on clinical practice guidelines[J]. Circulation. 2024;149(1):e1\u2013156.","journal-title":"Circulation"},{"issue":"5","key":"2417_CR2","doi-asserted-by":"publisher","first-page":"921","DOI":"10.1007\/s10840-024-01771-5","volume":"67","author":"S Tzeis","year":"2024","unstructured":"Tzeis S, Gerstenfeld EP, Kalman J, et al. 2024 European HeartRhythm Association\/Heart Rhythm Society\/Asia Pacific HeartRhythm Society\/Latin American Heart Rhythm Society Expert consensus statement on catheter and surgical ablation of atrial fibrillation[J]. J Interv Card Electrophysiol. 2024;67(5):921\u20131072.","journal-title":"J Interv Card Electrophysiol"},{"key":"2417_CR3","doi-asserted-by":"publisher","first-page":"e010516","DOI":"10.1161\/CIRCEP.121.010516","volume":"15","author":"CH Heeger","year":"2022","unstructured":"Heeger CH, Sohns C, Pott A, Metzner A, Inaba O, Straube F, et al. Phrenic nerve injury during cryoballoon-based pulmonary vein isolation: results of the worldwide YETI registry. Circ Arrhythm Electrophysiol. 2022;15:e010516.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2417_CR4","doi-asserted-by":"publisher","first-page":"2458","DOI":"10.1093\/eurheartj\/ehad250","volume":"44","author":"RR Tilz","year":"2023","unstructured":"Tilz RR, Schmidt V, P\u00fcrerfellner H, Maury P, Chun K, Martinek M, et al. A worldwide survey on incidence, management, and prognosis of oesophageal fistula formation following atrial fibrillation catheter ablation: the POTTER-AF study. Eur Heart J. 2023;44:2458\u201369.","journal-title":"Eur Heart J"},{"key":"2417_CR5","doi-asserted-by":"crossref","unstructured":"Neumcke B, Walz D, Lauger P. Nonlinear electrical effects in lipid bilayer membranes. 3. The dissociation field effect[ J ]. Biophys J. 1970;10(2):172\u201382.","DOI":"10.1016\/S0006-3495(70)86292-0"},{"issue":"2","key":"2417_CR6","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1007\/BF01872858","volume":"48","author":"R Benz","year":"1979","unstructured":"Benz R, Beckers F, Zimmermann U. Reversible electricalbreakdown of lipid bilayer membranes: a charge-pulse relaxationstudy. J Membr Biol. 1979;48(2):181\u2013204. https:\/\/doi.org\/10.1007\/BF01872858.","journal-title":"J Membr Biol"},{"issue":"4","key":"2417_CR7","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1016\/S0006-3495(89)82711-0","volume":"56","author":"DC Chang","year":"1989","unstructured":"Chang DC. Cell poration and cell fusion using an oscillating electricfield. Biophys J. 1989;56(4):641\u201352. https:\/\/doi.org\/10.1016\/S0006-3495(89)82711-0.","journal-title":"Biophys J"},{"issue":"1","key":"2417_CR8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0006-3495(90)82348-1","volume":"58","author":"DC Chang","year":"1990","unstructured":"Chang DC, Reese TS. Changes in membrane structure induced byelectroporation as revealed by rapid-freezing electron microscopy[J]. Biophys J. 1990;58(1):1\u201312. https:\/\/doi.org\/10.1016\/S0006-3495(90)82348-1.","journal-title":"Biophys J"},{"key":"2417_CR9","doi-asserted-by":"publisher","first-page":"2020","DOI":"10.1038\/s41591-024-03114-3","volume":"30","author":"E Ekanem","year":"2024","unstructured":"Ekanem E, Neuzil P, Reichlin T, Kautzner J, van der Voort P, Jais P, et al. Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17 K study. Nat Med. 2024;30:2020\u20139.","journal-title":"Nat Med"},{"key":"2417_CR10","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euad185","author":"B Schmidt","year":"2023","unstructured":"Schmidt B, Bordignon S, Neven K, Reichlin T, Blaauw Y, Hansen J, et al. European real- world outcomes with pulsed field ablation in patients with symptomatic atrial fibrillation: lessons from the multi-centre EU-PORIA registry. Europace. 2023. https:\/\/doi.org\/10.1093\/europace\/euad185.","journal-title":"Europace"},{"key":"2417_CR11","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euad244","author":"L Boersma","year":"2023","unstructured":"Boersma L, Andrade JG, Betts T, Duytschaever M, P\u00fcrerfellner H, Santoro F, et al. Progress in atrial fibrillation ablation during 25 years of europace journal. Europace. 2023. https:\/\/doi.org\/10.1093\/europace\/euad244.","journal-title":"Europace"},{"issue":"1","key":"2417_CR12","doi-asserted-by":"publisher","first-page":"e70277","DOI":"10.1002\/joa3.70277","volume":"42","author":"O Kamel","year":"2026","unstructured":"Kamel O, Sawalha K, Abdelazem M, Abdelghany A, Elsaid M, Sharief M, Ammar A. Outcomes of Pulsed Field Versus Cryoballoon Ablation in Atrial Fibrillation: A Comprehensive Systematic Review and Meta-Analysis. J Arrhythm. 2026;42(1):e70277.","journal-title":"J Arrhythm"},{"key":"2417_CR13","doi-asserted-by":"crossref","unstructured":"Reddy VY, Gerstenfeld EP, Mountantonakis SE et al. Pulsed field ablation versus conventional thermal ablation for paroxysmal atrial fibrillation: 4-year outcomes in the ADVENT-LTO study. Nat Med (2026).","DOI":"10.1038\/s41591-026-04246-4"},{"key":"2417_CR14","doi-asserted-by":"crossref","unstructured":"Tilz RR, Chierchia GB, Gunawardene M, Sanders P, Haqqani H, Kalman J, Healy S, P\u00fcrerfellner H, Neuzil P, Asensi JO, Loh P, Reddy VY, Knecht S, Jesser E, Dirckx N, Miller A, Walker D, Lakkireddy D. Safety and effectiveness of the first balloon-in-basket pulsed field ablation system for the treatment of atrial fibrillation: VOLT CE Mark Study 6-month results. Europace. 2025;27(4):euaf072.","DOI":"10.1093\/europace\/euaf072"},{"key":"2417_CR15","doi-asserted-by":"publisher","first-page":"e012732","DOI":"10.1161\/CIRCEP.124.012732","volume":"17","author":"MA Popa","year":"2024","unstructured":"Popa MA, Venier S, Men\u00e8 R, Della Rocca DG, Sacher F, Derval N, et al. Characterization and clinical significance of hemolysis after pulsed field ablation for atrial fibrillation: results of a multicenter analysis. Circ Arrhythm Electrophysiol. 2024;17:e012732.","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2417_CR16","doi-asserted-by":"publisher","first-page":"ehae666387","DOI":"10.1093\/eurheartj\/ehae666.387","volume":"45","author":"M Mercado Montoya","year":"2024","unstructured":"Mercado Montoya M, Gomez Bustamante T, Jessen M, Kulstad E, Mickelsen S, Overzet L. Quantification of hemolysis rates from pulsed field ablation. Eur Heart J. 2024;45:ehae666387.","journal-title":"Eur Heart J"},{"key":"2417_CR17","doi-asserted-by":"publisher","first-page":"1660","DOI":"10.1056\/NEJMoa2307291","volume":"389","author":"VY Reddy","year":"2023","unstructured":"Reddy VY, Gerstenfeld EP, Natale A, Whang W, Cuoco FA, Patel C, et al. Pulsed field or conventional thermal ablation for paroxysmal atrial fibrillation. N Engl J Med. 2023;389:1660\u201371.","journal-title":"N Engl J Med"},{"key":"2417_CR18","doi-asserted-by":"publisher","first-page":"1422","DOI":"10.1161\/CIRCULATIONAHA.123.063988","volume":"147","author":"A Verma","year":"2023","unstructured":"Verma A, Haines DE, Boersma LV, Sood N, Natale A, Marchlinski FE, et al. Pulsed field ablation for the treatment of atrial fibrillation: PULSED AF pivotal trial. Circulation. 2023;147:1422\u201332.","journal-title":"Circulation"},{"key":"2417_CR19","doi-asserted-by":"publisher","first-page":"1786","DOI":"10.1016\/j.jacep.2023.04.002","volume":"9","author":"VY Reddy","year":"2023","unstructured":"Reddy VY, Peichl P, Anter E, Rackauskas G, Petru J, Funasako M, et al. A focal ablation catheter toggling between radiofrequency and pulsed field energy to treat atrial fibrillation. JACC Clin Electrophysiol. 2023;9:1786\u2013801.","journal-title":"JACC Clin Electrophysiol"},{"key":"2417_CR20","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1161\/CIRCULATIONAHA.123.064959","volume":"148","author":"MK Turagam","year":"2023","unstructured":"Turagam MK, Neuzil P, Schmidt B, Reichlin T, Neven K, Metzner A, et al. Safety and effectiveness of pulsed field ablation to treat atrial fibrillation: one-year outcomes from the MANIFEST-PF registry. Circulation. 2023;148:35\u201346.","journal-title":"Circulation"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-026-02417-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-026-02417-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-026-02417-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T07:34:37Z","timestamp":1787124877000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-026-02417-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,19]]},"references-count":20,"alternative-id":["2417"],"URL":"https:\/\/doi.org\/10.1007\/s10840-026-02417-4","relation":{},"ISSN":["1572-8595"],"issn-type":[{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,19]]},"assertion":[{"value":"2 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 August 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study of the balloon-based PFA system was sponsored by EnChannel Medical.","order":1,"name":"Ethics","label":"Disclosure","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}