{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T08:06:24Z","timestamp":1789200384315,"version":"build-2803163510"},"reference-count":51,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T00:00:00Z","timestamp":1789171200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T00:00:00Z","timestamp":1789171200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100015135","name":"Haemonetics Corporation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100015135","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"DOI":"10.1007\/s10840-026-02437-0","type":"journal-article","created":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T07:43:07Z","timestamp":1789198987000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Participant-reported chest pain and gastric esophageal reflux disease following protective esophageal cooling during radiofrequency ablation for atrial fibrillation \u2013 the EVERCOOL-AF study"],"prefix":"10.1007","author":[{"given":"Joshua R.","family":"Silverstein","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George","family":"Shaw","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huy M.","family":"Phan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William A.","family":"Belden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emerson","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandru I.","family":"Costea","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Parin J.","family":"Patel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tiffany","family":"Sharkoski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qun","family":"Sha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erik","family":"Kulstad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Susan M.","family":"Bezenek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Singh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark D.","family":"Metzl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amit","family":"Thosani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,12]]},"reference":[{"issue":"8","key":"2437_CR1","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1161\/CIRCULATIONAHA.113.005119","volume":"129","author":"SS Chugh","year":"2010","unstructured":"Chugh SS, et al. Worldwide epidemiology of atrial fibrillation: a Global Burden of Disease 2010 Study. Circulation. 2010;129(8):837\u201347.","journal-title":"Circulation"},{"issue":"8","key":"2437_CR2","doi-asserted-by":"publisher","first-page":"e93","DOI":"10.1161\/cir.0000000000001123","volume":"147","author":"CW Tsao","year":"2023","unstructured":"Tsao CW, et al. Heart Disease and Stroke Statistics-2023 Update: a report from the American Heart Association. Circulation. 2023;147(8):e93\u2013621. https:\/\/doi.org\/10.1161\/cir.0000000000001123.","journal-title":"Circulation"},{"issue":"10","key":"2437_CR3","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1056\/NEJM199809033391003","volume":"339","author":"M Ha\u00efssaguerre","year":"1998","unstructured":"Ha\u00efssaguerre M, et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med. 1998;339(10):659\u201366. https:\/\/doi.org\/10.1056\/NEJM199809033391003.","journal-title":"N Engl J Med"},{"issue":"1","key":"2437_CR4","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1161\/cir.0000000000001193","volume":"149","author":"JA Joglar","year":"2023","unstructured":"Joglar JA, et al. 2023 ACC\/AHA\/ACCP\/HRS Guideline for the diagnosis and management of atrial fibrillation: a report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation. 2023;149(1):e1\u2013156. https:\/\/doi.org\/10.1161\/cir.0000000000001193.","journal-title":"Circulation"},{"issue":"14","key":"2437_CR5","doi-asserted-by":"publisher","first-page":"1377","DOI":"10.1161\/CIRCULATIONAHA.120.050991","volume":"143","author":"DL Packer","year":"2021","unstructured":"Packer DL, et al. Ablation Versus Drug Therapy for Atrial Fibrillation in Heart Failure. Circulation. 2021;143(14):1377\u201390. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.120.050991","journal-title":"Circulation"},{"issue":"3","key":"2437_CR6","doi-asserted-by":"publisher","first-page":"95","DOI":"10.5387\/fms.2021-23","volume":"67","author":"T Kaneshiro","year":"2021","unstructured":"Kaneshiro T, Takeishi Y. Esophageal thermal injury in catheter ablation of atrial fibrillation. Fukushima J Med Sci. 2021;67(3):95\u2013101. https:\/\/doi.org\/10.5387\/fms.2021-23.","journal-title":"Fukushima J Med Sci"},{"key":"2437_CR7","doi-asserted-by":"publisher","DOI":"10.1161\/circep.117.005579","author":"HC Han","year":"2017","unstructured":"Han HC, et al. Atrioesophageal fistula: clinical presentation, procedural characteristics, diagnostic investigations, and treatment outcomes. Circ Arrhythm Electrophysiol. 2017. https:\/\/doi.org\/10.1161\/circep.117.005579.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"13","key":"2437_CR8","doi-asserted-by":"publisher","first-page":"1247","DOI":"10.1161\/circulationaha.117.025827","volume":"136","author":"S Kapur","year":"2017","unstructured":"Kapur S, Barbhaiya C, Deneke T, Michaud GF. Esophageal injury and atrioesophageal fistula caused by ablation for atrial fibrillation. Circulation. 2017;136(13):1247\u201355. https:\/\/doi.org\/10.1161\/circulationaha.117.025827.","journal-title":"Circulation"},{"issue":"3","key":"2437_CR9","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1016\/j.jacep.2019.10.014","volume":"6","author":"SY Sarairah","year":"2020","unstructured":"Sarairah SY, Woodbury B, Methachittiphan N, Tregoning DM, Sridhar AR, Akoum N. Esophageal thermal injury following cryoballoon ablation for atrial fibrillation. JACC Clin Electrophysiol. 2020;6(3):262\u20138. https:\/\/doi.org\/10.1016\/j.jacep.2019.10.014.","journal-title":"JACC Clin Electrophysiol"},{"issue":"2","key":"2437_CR10","doi-asserted-by":"publisher","first-page":"143","DOI":"10.4070\/kcj.2020.0323","volume":"51","author":"U Do","year":"2021","unstructured":"Do U, et al. Esophageal thermal injury after catheter ablation for atrial fibrillation with high-power (50 watts) radiofrequency energy. Korean Circ J. 2021;51(2):143\u201353. https:\/\/doi.org\/10.4070\/kcj.2020.0323.","journal-title":"Korean Circ J"},{"issue":"9","key":"2437_CR11","doi-asserted-by":"publisher","first-page":"632","DOI":"10.1016\/j.hrcr.2022.06.007","volume":"8","author":"KA Berggren","year":"2022","unstructured":"Berggren KA, Janardhan AH. Unusual esophageal injury after atrial fibrillation ablation: early diagnosis and treatment to optimize outcomes. HeartRhythm Case Rep. 2022;8(9):632\u20135. https:\/\/doi.org\/10.1016\/j.hrcr.2022.06.007.","journal-title":"HeartRhythm Case Rep"},{"issue":"7","key":"2437_CR12","doi-asserted-by":"publisher","first-page":"1450","DOI":"10.1111\/jce.15553","volume":"33","author":"Y Ishidoya","year":"2022","unstructured":"Ishidoya Y, et al. Short-term natural course of esophageal thermal injury after ablation for atrial fibrillation. J Cardiovasc Electrophysiol. 2022;33(7):1450\u20139. https:\/\/doi.org\/10.1111\/jce.15553.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"7","key":"2437_CR13","doi-asserted-by":"publisher","first-page":"1464","DOI":"10.1016\/j.hrthm.2015.04.005","volume":"12","author":"P M\u00fcller","year":"2015","unstructured":"M\u00fcller P, et al. Higher incidence of esophageal lesions after ablation of atrial fibrillation related to the use of esophageal temperature probes. Heart Rhythm. 2015;12(7):1464\u20139. https:\/\/doi.org\/10.1016\/j.hrthm.2015.04.005.","journal-title":"Heart Rhythm"},{"issue":"6","key":"2437_CR14","doi-asserted-by":"publisher","first-page":"891","DOI":"10.1093\/europace\/euu356","volume":"17","author":"CM Tschabrunn","year":"2015","unstructured":"Tschabrunn CM, et al. Comparison between single- and multi-sensor oesophageal temperature probes during atrial fibrillation ablation: thermodynamic characteristics. Europace. 2015;17(6):891\u20137. https:\/\/doi.org\/10.1093\/europace\/euu356.","journal-title":"Europace"},{"issue":"10","key":"2437_CR15","doi-asserted-by":"publisher","first-page":"1146","DOI":"10.1016\/j.jacep.2017.03.017","volume":"3","author":"C Palaniswamy","year":"2017","unstructured":"Palaniswamy C, et al. The extent of mechanical esophageal deviation to avoid esophageal heating during catheter ablation of atrial fibrillation. JACC Clin Electrophysiol. 2017;3(10):1146\u201354. https:\/\/doi.org\/10.1016\/j.jacep.2017.03.017.","journal-title":"JACC Clin Electrophysiol"},{"issue":"5","key":"2437_CR16","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1016\/j.tcm.2018.09.010","volume":"29","author":"AJ Kadado","year":"2019","unstructured":"Kadado AJ, Akar JG, Hummel JP. Luminal esophageal temperature monitoring to reduce esophageal thermal injury during catheter ablation for atrial fibrillation: A review, (in eng). Trends Cardiovasc Med. 2019;29(5):264\u201371. https:\/\/doi.org\/10.1016\/j.tcm.2018.09.010","journal-title":"Trends Cardiovasc Med"},{"issue":"9","key":"2437_CR17","doi-asserted-by":"publisher","first-page":"958","DOI":"10.1111\/jce.12180","volume":"24","author":"BJ Carroll","year":"2013","unstructured":"Carroll BJ, et al Multi-sensor esophageal temperature probe used during radiofrequency ablation for atrial fibrillation is associated with increased intraluminal temperature detection and increased risk of esophageal injury compared to single-sensor probe, (in eng). J Cardiovasc Electrophysiol. 2013;24(9):958\u201364. https:\/\/doi.org\/10.1111\/jce.12180.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"5","key":"2437_CR18","doi-asserted-by":"publisher","first-page":"920","DOI":"10.1111\/jce.15433","volume":"33","author":"J Mueller","year":"2022","unstructured":"Mueller J, et al. Safety aspects of very high power very short duration atrial fibrillation ablation using a modified radiofrequency RF-generator: single\u2010center experience. J Cardiovasc Electrophysiol. 2022;33(5):920\u20137. https:\/\/doi.org\/10.1111\/jce.15433.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"3","key":"2437_CR19","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1007\/s10840-013-9868-5","volume":"39","author":"T Kuwahara","year":"2014","unstructured":"Kuwahara T, et al. Incidences of esophageal injury during esophageal temperature monitoring: a comparative study of a multi-thermocouple temperature probe and a deflectable temperature probe in atrial fibrillation ablation. J Interv Card Electrophysiol. 2014;39(3):251\u20137. https:\/\/doi.org\/10.1007\/s10840-013-9868-5.","journal-title":"J Interv Card Electrophysiol"},{"issue":"5","key":"2437_CR20","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1016\/j.tcm.2018.09.010","volume":"29","author":"AJ Kadado","year":"2019","unstructured":"Kadado AJ, Akar JG, Hummel JP. Luminal esophageal temperature monitoring to reduce esophageal thermal injury during catheter ablation for atrial fibrillation: A review. Trends Cardiovasc Med. 2019;29(5):264\u201371. https:\/\/doi.org\/10.1016\/j.tcm.2018.09.010","journal-title":"Trends Cardiovasc Med"},{"issue":"6","key":"2437_CR21","doi-asserted-by":"publisher","first-page":"926","DOI":"10.1016\/j.hrthm.2021.02.003","volume":"18","author":"D Grosse Meininghaus","year":"2021","unstructured":"Grosse Meininghaus D, et al. Temperature monitoring and temperature-driven irrigated radiofrequency energy titration do not prevent thermally induced esophageal lesions in pulmonary vein isolation: a randomized study controlled by esophagoscopy before and after catheter ablation. Heart Rhythm. 2021;18(6):926\u201334. https:\/\/doi.org\/10.1016\/j.hrthm.2021.02.003.","journal-title":"Heart Rhythm"},{"issue":"8","key":"2437_CR22","doi-asserted-by":"publisher","first-page":"1827","DOI":"10.1007\/s10840-023-01492-1","volume":"66","author":"NM Abdulsalam","year":"2023","unstructured":"Abdulsalam NM, et al. Esophageal luminal temperature monitoring using a multi-sensor probe lowers the risk of esophageal injury in cryo and radiofrequency catheter ablation for atrial fibrillation. J Interventional Cardiac Electrophysiol. 2023;66(8):1827\u201335. https:\/\/doi.org\/10.1007\/s10840-023-01492-1","journal-title":"J Interventional Cardiac Electrophysiol"},{"issue":"1","key":"2437_CR23","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/j.jacep.2023.09.004","volume":"10","author":"R Weiss","year":"2024","unstructured":"Weiss R, et al. Esophagus deviation during radiofrequency ablation of atrial fibrillation. JACC Clin Electrophysiol. 2024;10(1):68\u201378. https:\/\/doi.org\/10.1016\/j.jacep.2023.09.004.","journal-title":"JACC Clin Electrophysiol"},{"issue":"3","key":"2437_CR24","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1093\/eurjcn\/zvad068","volume":"23","author":"M Reading Turchioe","year":"2023","unstructured":"Reading Turchioe M, et al. Characterizing atrial fibrillation symptom improvement following de novo catheter ablation. Eur J Cardiovasc Nurs. 2023;23(3):241\u201350. https:\/\/doi.org\/10.1093\/eurjcn\/zvad068.","journal-title":"Eur J Cardiovasc Nurs"},{"issue":"5","key":"2437_CR25","doi-asserted-by":"publisher","DOI":"10.4022\/jafib.2110","volume":"11","author":"MM Montoya","year":"2019","unstructured":"Montoya MM, et al. Protecting the esophagus from thermal injury during radiofrequency ablation with an esophageal cooling device. J Atr Fibrillation. 2019;11(5):2110. https:\/\/doi.org\/10.4022\/jafib.2110.","journal-title":"J Atr Fibrillation"},{"issue":"1","key":"2437_CR26","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1186\/s12938-020-00821-z","volume":"19","author":"M Mercado","year":"2020","unstructured":"Mercado M, Leung L, Gallagher M, Shah S, Kulstad E. Modeling esophageal protection from radiofrequency ablation via a cooling device: an analysis of the effects of ablation power and heart wall dimensions. Biomed Eng Online. 2020;19(1):77. https:\/\/doi.org\/10.1186\/s12938-020-00821-z.","journal-title":"Biomed Eng Online"},{"issue":"1","key":"2437_CR27","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1007\/s10840-021-00960-w","volume":"63","author":"CM Tschabrunn","year":"2022","unstructured":"Tschabrunn CM, et al Active esophageal cooling for the prevention of thermal injury during atrial fibrillation ablation: a randomized controlled pilot study, (in eng). J Interv Card Electrophysiol. 2022;63(1):197\u2013205. https:\/\/doi.org\/10.1007\/s10840-021-00960-w.","journal-title":"J Interv Card Electrophysiol"},{"issue":"3","key":"2437_CR28","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1007\/s10840-022-01204-1","volume":"65","author":"C Joseph","year":"2022","unstructured":"Joseph C, Sherman J, Ro A, Fisher WG, Nazari J, Metzl M Procedural time reduction associated with active esophageal cooling during pulmonary vein isolation, (in eng). J Interv Card Electrophysiol. 2022;65(3):617\u201323. https:\/\/doi.org\/10.1007\/s10840-022-01204-1.","journal-title":"J Interv Card Electrophysiol"},{"issue":"7","key":"2437_CR29","doi-asserted-by":"publisher","first-page":"1621","DOI":"10.1007\/s10840-023-01474-3","volume":"66","author":"C Joseph","year":"2023","unstructured":"Joseph C, et al. Improved 1-year outcomes after active cooling during left atrial radiofrequency ablation. J Interv Card Electrophysiol. 2023;66(7):1621\u20139. https:\/\/doi.org\/10.1007\/s10840-023-01474-3.","journal-title":"J Interv Card Electrophysiol"},{"issue":"11","key":"2437_CR30","doi-asserted-by":"publisher","first-page":"5236","DOI":"10.19102\/icrm.2022.13111","volume":"13","author":"B Clark","year":"2022","unstructured":"Clark B, Alvi N, Hanks J, Joseph C, Suprenant B. An esophageal cooling device during radiofrequency ablation for atrial fibrillation-a comparison between reactive and proactive esophageal cooling. J Innov Card Rhythm Manag. 2022;13(11):5236\u201343. https:\/\/doi.org\/10.19102\/icrm.2022.13111.","journal-title":"J Innov Card Rhythm Manag"},{"issue":"2","key":"2437_CR31","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1093\/europace\/euaa276","volume":"23","author":"LWM Leung","year":"2021","unstructured":"Leung LWM, et al. Randomized comparison of oesophageal protection with a temperature control device: results of the IMPACT study. Europace. 2021;23(2):205\u201315. https:\/\/doi.org\/10.1093\/europace\/euaa276.","journal-title":"Europace"},{"key":"2437_CR32","doi-asserted-by":"publisher","unstructured":"Joseph C, Cooper J, Turer RW, McDonald SA, Kulstad EB, Daniels J. Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation, (in eng). J Vis Exp. 2022;186. https:\/\/doi.org\/10.3791\/64417.","DOI":"10.3791\/64417"},{"issue":"11","key":"2437_CR33","doi-asserted-by":"publisher","first-page":"2083","DOI":"10.1016\/j.hrthm.2024.04.090","volume":"21","author":"J Osorio","year":"2083","unstructured":"Osorio J, et al. Real-world data of radiofrequency catheter ablation in paroxysmal atrial fibrillation: short- and long-term clinical outcomes from the prospective multicenter REAL-AF registry. Heart Rhythm. 2083;21(11):2083\u201391. https:\/\/doi.org\/10.1016\/j.hrthm.2024.04.090.","journal-title":"Heart Rhythm"},{"issue":"12","key":"2437_CR34","doi-asserted-by":"publisher","DOI":"10.1111\/nmo.14619","volume":"35","author":"DM Simadibrata","year":"2023","unstructured":"Simadibrata DM, Ngadiono E, Sinuraya FAG, Damara I, Fass R, Simadibrata M. Diagnostic accuracy of gastroesophageal reflux disease questionnaire for gastroesophageal reflux disease: a systematic review and meta-analysis. Neurogastroenterol Motil. 2023;35(12):e14619. https:\/\/doi.org\/10.1111\/nmo.14619.","journal-title":"Neurogastroenterol Motil"},{"issue":"10","key":"2437_CR35","doi-asserted-by":"publisher","first-page":"1030","DOI":"10.1111\/j.1365-2036.2009.04142.x","volume":"30","author":"R Jones","year":"2009","unstructured":"Jones R, et al. Development of the GerdQ, a tool for the diagnosis and management of gastro-oesophageal reflux disease in primary care. Aliment Pharmacol Ther. 2009;30(10):1030\u20138. https:\/\/doi.org\/10.1111\/j.1365-2036.2009.04142.x.","journal-title":"Aliment Pharmacol Ther"},{"key":"2437_CR36","unstructured":"HAEMONETICS, ensoETM. Instructions Use https:\/\/hospital.haemonetics.com\/training-and-resources\/resources?accordion=6 (accessed 2025)."},{"key":"2437_CR37","doi-asserted-by":"publisher","DOI":"10.3390\/life13051107","author":"M Floria","year":"2023","unstructured":"Floria M, et al. Gastro-esophageal reflux disease and paroxysmal atrial fibrillation ablation. Life (Basel). 2023. https:\/\/doi.org\/10.3390\/life13051107.","journal-title":"Life (Basel)"},{"issue":"6","key":"2437_CR38","doi-asserted-by":"publisher","first-page":"e24595","DOI":"10.1097\/md.0000000000024595","volume":"100","author":"JH Ahn","year":"2021","unstructured":"Ahn JH, et al. The frequency of gastroesophageal reflux when radiofrequency catheter ablation procedures for atrial fibrillation under general anesthesia with a supraglottic device: Observational pilot study, (in eng). Med (Baltim). 2021;100(6):e24595. https:\/\/doi.org\/10.1097\/md.0000000000024595","journal-title":"Med (Baltim)"},{"issue":"10","key":"2437_CR39","doi-asserted-by":"publisher","first-page":"1457","DOI":"10.1016\/j.hrthm.2009.06.022","volume":"6","author":"M Martinek","year":"2009","unstructured":"Martinek M, et al. Acute development of gastroesophageal reflux after radiofrequency catheter ablation of atrial fibrillation. Heart Rhythm. 2009;6(10):1457\u201362. https:\/\/doi.org\/10.1016\/j.hrthm.2009.06.022.","journal-title":"Heart Rhythm"},{"key":"2437_CR40","doi-asserted-by":"publisher","unstructured":"Raviele A. Is Colchicine Useful to Prevent Post-AF Ablation Pericarditis? JACC: Clinical Electrophysiology. 2023;9(7_Part_2):1067\u20131069. https:\/\/doi.org\/10.1016\/j.jacep.2023.02.015","DOI":"10.1016\/j.jacep.2023.02.015"},{"issue":"10","key":"2437_CR41","doi-asserted-by":"publisher","first-page":"e275","DOI":"10.1016\/j.hrthm.2017.05.012","volume":"14","author":"H Calkins","year":"2017","unstructured":"Calkins H, et al 2017 HRS\/EHRA\/ECAS\/APHRS\/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation, (in eng). Heart Rhythm. 2017;14(10):e275\u2013444. https:\/\/doi.org\/10.1016\/j.hrthm.2017.05.012.","journal-title":"Heart Rhythm"},{"issue":"6","key":"2437_CR42","doi-asserted-by":"publisher","first-page":"1150","DOI":"10.1111\/jce.16263","volume":"35","author":"W Zagrodzky","year":"2024","unstructured":"Zagrodzky W, et al. Association between proactive esophageal cooling and increased lab throughput. J Cardiovasc Electrophysiol. 2024;35(6):1150\u20135. https:\/\/doi.org\/10.1111\/jce.16263.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"3","key":"2437_CR43","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1016\/j.hroo.2022.02.008","volume":"3","author":"S Nakhla","year":"2022","unstructured":"Nakhla S, et al. Acute pericarditis after atrial fibrillation ablation: Incidence, characteristics, and risk factors, (in eng). Heart Rhythm O2. 2022;3(3):248\u201351. https:\/\/doi.org\/10.1016\/j.hroo.2022.02.008","journal-title":"Heart Rhythm O2"},{"issue":"Supplement_1","key":"2437_CR44","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euac053.085","volume":"24","author":"E Kulstad","year":"2022","unstructured":"Kulstad E, et al. Influence of tissue thickness on thermal latency during high-power short-duration radiofrequency ablation with proactive esophageal cooling. Europace. 2022;24(Supplement_1):euac053.085.","journal-title":"Europace"},{"issue":"Suppl1","key":"2437_CR45","first-page":"A10771","volume":"144","author":"M Mercado Montoya","year":"2021","unstructured":"Mercado Montoya M, et al. Avoidance of Lethal Isotherm Formation in Esophageal Tissue with an Active Cooling Device Under High-Power, Short-Duration Ablation. Circulation. 2021;144(Suppl1):A10771\u201310771.","journal-title":"Circulation"},{"issue":"12","key":"2437_CR46","doi-asserted-by":"publisher","first-page":"949","DOI":"10.1080\/17434440.2022.2150930","volume":"19","author":"J Cooper","year":"2022","unstructured":"Cooper J, et al. Active esophageal cooling during radiofrequency ablation of the left atrium: data review and update. Expert Rev Med Devices. 2022;19(12):949\u201357. https:\/\/doi.org\/10.1080\/17434440.2022.2150930.","journal-title":"Expert Rev Med Devices"},{"key":"2437_CR47","doi-asserted-by":"crossref","unstructured":"Zagrodzky W et al. Reduced Post-Ablation Chest Pain with Proactive Esophageal Cooling. J Atr Fibrillation Electrophysiol, 2024.","DOI":"10.22541\/au.169963495.52356965\/v1"},{"issue":"3","key":"2437_CR48","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1111\/jce.15820","volume":"34","author":"D Grosse Meininghaus","year":"2023","unstructured":"Grosse Meininghaus D, Freund R, Kleemann T, Geller JC, Matthes H. Pulmonary vein isolation-induced vagal nerve injury and gastric motility disorders detected by electrogastrography: the side effects of pulmonary vein isolation in atrial fibrillation (SEPIA) study. J Cardiovasc Electrophysiol. 2023;34(3):583\u201392. https:\/\/doi.org\/10.1111\/jce.15820.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"1","key":"2437_CR49","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1515\/cdbme-2023-1122","volume":"9","author":"M Leuchter","year":"2023","unstructured":"Leuchter M, Siewert S, Stiehm M, Klar E, Schmitz K-P, Kaule S. Randomized Registry Trials-efficient post market clinical follow-up for medical devices: De Gruyter. Curr Dir Biomedical Eng. 2023;9(1):487\u201390.","journal-title":"Curr Dir Biomedical Eng"},{"issue":"5","key":"2437_CR50","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1016\/j.cmi.2022.11.023","volume":"29","author":"L Escol\u00e0-Verg\u00e9","year":"2023","unstructured":"Escol\u00e0-Verg\u00e9 L, Ribera A, Ferreira-Gonz\u00e1lez I, Peric\u00e0s JM, Fern\u00e1ndez-Hidalgo N. Strengths and limitations of patient registries in infective endocarditis. Clin Microbiol Infect. 2023;29(5):587\u201392. https:\/\/doi.org\/10.1016\/j.cmi.2022.11.023.","journal-title":"Clin Microbiol Infect"},{"key":"2437_CR51","doi-asserted-by":"crossref","unstructured":"Taur SR. Observational designs for real-world evidence studies. Perspectives in Clinical Research. 2022;13(1). Available: https:\/\/journals.lww.com\/picp\/fulltext\/2022\/13010\/observational_designs_for_real_world_evidence.3.aspx","DOI":"10.4103\/picr.picr_217_21"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-026-02437-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-026-02437-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-026-02437-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T07:43:10Z","timestamp":1789198990000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-026-02437-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,12]]},"references-count":51,"alternative-id":["2437"],"URL":"https:\/\/doi.org\/10.1007\/s10840-026-02437-0","relation":{},"ISSN":["1572-8595"],"issn-type":[{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,12]]},"assertion":[{"value":"13 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"JS provides consulting for Biosense Webster, Inc., part of Johnson & Johnson MedTech, Medtronic, and Impulse Dynamics. MM reports consulting for Atverse, Biosense Webster, Inc., part of Johnson & Johnson MedTech, Boston Scientific, Medtronic, and Philips. Funding Source: Funding for this analysis was provided from Haemonetics. While data from the REAL-AF registry was used for this analysis, the results, conclusions, opinions, and views made in this publication have not been reviewed or endorsed by Biosense Webster, Inc., part of Johnson & Johnson MedTech.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}