{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T07:53:04Z","timestamp":1791359584547,"version":"4.3.1"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T00:00:00Z","timestamp":1790035200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T00:00:00Z","timestamp":1790035200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Interv Card Electrophysiol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The benefit of preemptive mechanical circulatory support (MCS) for ventricular tachycardia (VT) ablation remains unclear. This meta-analysis compared the efficacy and safety of preemptive MCS to standard care for VT ablation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>An unrestricted literature search of PubMed, Embase, and Web of Science identified studies on preemptive MCS for VT ablation. MCS included percutaneous left ventricular assist devices or extracorporeal membrane oxygenation. The primary endpoint was all-cause mortality; secondary endpoints included VT recurrence, procedural time, procedural complications (vascular access, bleeding, stroke, pericardial effusion, heart failure, myocardial infarction), and 30-day major adverse cardiovascular events (MACE).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Eight studies with 2,262 patients (414 with MCS, 1,848 without) were included. Mean follow-up was 15.8 months, mean age was 62.6 years, 12.5% were women, and mean PAINESD scores were 15.7 in the MCS group and 10.5 in the no-MCS group. There was no significant difference in all-cause mortality (OR 1.58, 95% CI 0.60\u20134.19,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.36, I\u00b2=81%) or VT recurrence (OR 1.03, 95% CI 0.68\u20131.56,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.90, I\u00b2=46%). Preemptive MCS was associated with longer procedural times (mean difference 46.0\u00a0min, 95% CI 11.1\u201380.8,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.01, I\u00b2=86%), more procedural complications\u2014driven by vascular access and pericardial effusion (OR 2.25, 95% CI 1.26\u20134.03,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.006, I\u00b2=33%). Thirty-day MACE was not uniformly defined across studies and was therefore not pooled.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Preemptive MCS was not associated with a significant difference in all-cause mortality or VT recurrence in patients undergoing VT ablation but was associated with longer procedures, and more procedural complications. The certainty of evidence was very low, reflecting the observational study design, baseline imbalance between groups, and heterogeneity; these findings do not preclude the selective use of MCS in high-risk patients and require confirmation in randomized trials.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s10840-026-02445-0","type":"journal-article","created":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T06:53:10Z","timestamp":1790059990000},"page":"1503-1512","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Preemptive mechanical circulatory support in ventricular tachycardia ablation: A systematic review and meta-analysis"],"prefix":"10.1007","volume":"69","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3358-4458","authenticated-orcid":false,"given":"David T.","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mriganka","family":"Nerkar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saborny","family":"Mahmud","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abhijeet","family":"Singh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ibrahim O.","family":"Almasry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roger","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric J.","family":"Rashba","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,22]]},"reference":[{"issue":"1","key":"2445_CR1","doi-asserted-by":"publisher","first-page":"e2","DOI":"10.1016\/j.hrthm.2019.03.002","volume":"17","author":"EM Cronin","year":"2020","unstructured":"Cronin EM, Bogun FM, Maury P, et al. 2019 HRS\/EHRA\/APHRS\/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias. Heart Rhythm. 2020;17(1):e2\u2013154.","journal-title":"Heart Rhythm"},{"issue":"25","key":"2445_CR2","doi-asserted-by":"publisher","first-page":"2773","DOI":"10.1161\/CIRCULATIONAHA.108.788604","volume":"118","author":"WG Stevenson","year":"2008","unstructured":"Stevenson WG, Wilber DJ, Natale A, et al. Irrigated radiofrequency catheter ablation guided by electroanatomic mapping for recurrent ventricular tachycardia after myocardial infarction: the multicenter thermocool ventricular tachycardia ablation trial. Circulation. 2008;118(25):2773\u201382.","journal-title":"Circulation"},{"issue":"3","key":"2445_CR3","doi-asserted-by":"publisher","first-page":"e389","DOI":"10.1161\/CIRCULATIONAHA.110.963371","volume":"122","author":"R Tung","year":"2010","unstructured":"Tung R, Boyle NG, Shivkumar K. Catheter ablation of ventricular tachycardia. Circulation. 2010;122(3):e389\u2013391.","journal-title":"Circulation"},{"issue":"13","key":"2445_CR4","doi-asserted-by":"publisher","first-page":"1363","DOI":"10.1016\/j.jacc.2011.06.022","volume":"58","author":"MA Miller","year":"2011","unstructured":"Miller MA, Dukkipati SR, Mittnacht AJ, et al. Activation and entrainment mapping of hemodynamically unstable ventricular tachycardia using a percutaneous left ventricular assist device. J Am Coll Cardiol. 2011;58(13):1363\u201371.","journal-title":"J Am Coll Cardiol"},{"issue":"8","key":"2445_CR5","doi-asserted-by":"publisher","first-page":"1166","DOI":"10.1093\/europace\/euaa371","volume":"23","author":"P Della Bella","year":"2021","unstructured":"Della Bella P, Radinovic A, Limite LR, Baratto F. Mechanical circulatory support in the management of life-threatening arrhythmia. Europace. 2021;23(8):1166\u201378.","journal-title":"Europace"},{"issue":"1","key":"2445_CR6","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1161\/CIRCEP.114.002155","volume":"8","author":"P Santangeli","year":"2015","unstructured":"Santangeli P, Muser D, Zado ES, et al. Acute hemodynamic decompensation during catheter ablation of scar-related ventricular tachycardia: incidence, predictors, and impact on mortality. Circ Arrhythm Electrophysiol. 2015;8(1):68\u201375.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"19","key":"2445_CR7","doi-asserted-by":"publisher","first-page":"e7","DOI":"10.1016\/j.jacc.2015.03.036","volume":"65","author":"CS Rihal","year":"2015","unstructured":"Rihal CS, Naidu SS, Givertz MM, et al. 2015 SCAI\/ACC\/HFSA\/STS Clinical Expert Consensus Statement on the Use of Percutaneous Mechanical Circulatory Support Devices in Cardiovascular Care: Endorsed by the American Heart Assocation, the Cardiological Society of India, and Sociedad Latino Americana de Cardiologia Intervencion; Affirmation of Value by the Canadian Association of Interventional Cardiology-Association Canadienne de Cardiologie d\u2019intervention. J Am Coll Cardiol. 2015;65(19):e7\u201326.","journal-title":"J Am Coll Cardiol"},{"issue":"23","key":"2445_CR8","doi-asserted-by":"publisher","first-page":"2924","DOI":"10.1016\/j.jacc.2017.10.030","volume":"70","author":"SR Dukkipati","year":"2017","unstructured":"Dukkipati SR, Koruth JS, Choudry S, Miller MA, Whang W, Reddy VY. Catheter Ablation of Ventricular Tachycardia in Structural Heart Disease: Indications, Strategies, and Outcomes-Part II. J Am Coll Cardiol. 2017;70(23):2924\u201341.","journal-title":"J Am Coll Cardiol"},{"issue":"7","key":"2445_CR9","doi-asserted-by":"publisher","first-page":"1122","DOI":"10.1016\/j.hrthm.2014.04.018","volume":"11","author":"A Aryana","year":"2014","unstructured":"Aryana A, Gearoid O\u2019Neill P, Gregory D, et al. Procedural and clinical outcomes after catheter ablation of unstable ventricular tachycardia supported by a percutaneous left ventricular assist device. Heart Rhythm. 2014;11(7):1122\u201330.","journal-title":"Heart Rhythm"},{"issue":"5","key":"2445_CR10","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1093\/europace\/eur347","volume":"14","author":"TJ Bunch","year":"2012","unstructured":"Bunch TJ, Darby A, May HT, et al. Efficacy and safety of ventricular tachycardia ablation with mechanical circulatory support compared with substrate-based ablation techniques. Europace. 2012;14(5):709\u201314.","journal-title":"Europace"},{"key":"2445_CR11","doi-asserted-by":"publisher","first-page":"747858","DOI":"10.3389\/fcvm.2021.747858","volume":"8","author":"M Grimaldi","year":"2021","unstructured":"Grimaldi M, Marino MM, Vitulano N, et al. Cardiopulmonary Support During Catheter Ablation of Ventricular Arrhythmias With Hemodynamic Instability: The Role of Inducibility. Front Cardiovasc Med. 2021;8:747858.","journal-title":"Front Cardiovasc Med"},{"issue":"2","key":"2445_CR12","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.jjcc.2022.09.010","volume":"81","author":"N Kataoka","year":"2023","unstructured":"Kataoka N, Imamura T, Uchida K, Koi T, Nakamura M, Kinugawa K. Urgent catheter ablation in Japanese patients with mechanical circulatory supports suffering from refractory ventricular electrical storm. J Cardiol. 2023;81(2):229\u201335.","journal-title":"J Cardiol"},{"key":"2445_CR13","doi-asserted-by":"crossref","unstructured":"Kusa S, Miller MA, Whang W et al. Outcomes of Ventricular Tachycardia Ablation Using Percutaneous Left Ventricular Assist Devices. Circ Arrhythm Electrophysiol 2017;10(6).","DOI":"10.1161\/CIRCEP.116.004717"},{"issue":"10","key":"2445_CR14","doi-asserted-by":"publisher","first-page":"1500","DOI":"10.1016\/j.hrthm.2018.04.028","volume":"15","author":"D Muser","year":"2018","unstructured":"Muser D, Liang JJ, Castro SA, et al. Outcomes with prophylactic use of percutaneous left ventricular assist devices in high-risk patients undergoing catheter ablation of scar-related ventricular tachycardia: A propensity-score matched analysis. Heart Rhythm. 2018;15(10):1500\u20136.","journal-title":"Heart Rhythm"},{"issue":"5","key":"2445_CR15","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1016\/j.jacc.2023.05.012","volume":"82","author":"J Sroubek","year":"2023","unstructured":"Sroubek J, Vajapey R, Sipko JJ, et al. First-in-Human Experience With Impella 5.0\/5.5 for High-Risk Patients With Advanced Heart Failure Undergoing VT Ablation. J Am Coll Cardiol. 2023;82(5):469\u201371.","journal-title":"J Am Coll Cardiol"},{"issue":"13","key":"2445_CR16","doi-asserted-by":"publisher","first-page":"1534","DOI":"10.1016\/j.jacep.2017.07.005","volume":"3","author":"MK Turagam","year":"2017","unstructured":"Turagam MK, Vuddanda V, Atkins D, et al. Hemodynamic Support in Ventricular Tachycardia Ablation: An International VT Ablation Center Collaborative Group Study. JACC Clin Electrophysiol. 2017;3(13):1534\u201343.","journal-title":"JACC Clin Electrophysiol"},{"issue":"2","key":"2445_CR17","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1007\/s10840-018-0477-1","volume":"55","author":"MK Turagam","year":"2019","unstructured":"Turagam MK, Vuddanda V, Koerber S, et al. Percutaneous ventricular assist device in ventricular tachycardia ablation: a systematic review and meta-analysis. J Interv Card Electrophysiol. 2019;55(2):197\u2013205.","journal-title":"J Interv Card Electrophysiol"},{"issue":"9","key":"2445_CR18","doi-asserted-by":"publisher","first-page":"987","DOI":"10.1111\/aor.13945","volume":"45","author":"S Mariani","year":"2021","unstructured":"Mariani S, Napp LC, Kraaier K, et al. Prophylactic mechanical circulatory support for protected ventricular tachycardia ablation: A meta-analysis of the literature. Artif Organs. 2021;45(9):987\u201397.","journal-title":"Artif Organs"},{"issue":"12","key":"2445_CR19","doi-asserted-by":"publisher","first-page":"2673","DOI":"10.1016\/j.jacep.2025.07.016","volume":"11","author":"I Kawamura","year":"2025","unstructured":"Kawamura I, Koruth JS, Kusa S, et al. Outcomes of Scar-Related Ventricular Tachycardia Ablation With Percutaneous Left Ventricular Assist Device Support. JACC Clin Electrophysiol. 2025;11(12):2673\u201384.","journal-title":"JACC Clin Electrophysiol"},{"issue":"1","key":"2445_CR20","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1007\/s10840-016-0168-8","volume":"48","author":"N Mathuria","year":"2017","unstructured":"Mathuria N, Wu G, Rojas-Delgado F, et al. Outcomes of pre-emptive and rescue use of percutaneous left ventricular assist device in patients with structural heart disease undergoing catheter ablation of ventricular tachycardia. J Interv Card Electrophysiol. 2017;48(1):27\u201334.","journal-title":"J Interv Card Electrophysiol"},{"issue":"2","key":"2445_CR21","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1161\/CIRCEP.113.000548","volume":"7","author":"YM Reddy","year":"2014","unstructured":"Reddy YM, Chinitz L, Mansour M, et al. Percutaneous left ventricular assist devices in ventricular tachycardia ablation: multicenter experience. Circ Arrhythm Electrophysiol. 2014;7(2):244\u201350.","journal-title":"Circ Arrhythm Electrophysiol"}],"container-title":["Journal of Interventional Cardiac Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-026-02445-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10840-026-02445-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10840-026-02445-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T07:30:29Z","timestamp":1791358229000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10840-026-02445-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,22]]},"references-count":21,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["2445"],"URL":"https:\/\/doi.org\/10.1007\/s10840-026-02445-0","relation":{},"ISSN":["1572-8595"],"issn-type":[{"value":"1572-8595","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,22]]},"assertion":[{"value":"15 June 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}