{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T10:51:56Z","timestamp":1787914316112,"version":"build-2784847793"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2015,6,1]],"date-time":"2015-06-01T00:00:00Z","timestamp":1433116800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"name":"UEDFISCDI","award":["ID304\/2011"],"award-info":[{"award-number":["ID304\/2011"]}]},{"DOI":"10.13039\/501100006595","name":"UEFISCDI","doi-asserted-by":"crossref","award":["PCCA244\/2014"],"award-info":[{"award-number":["PCCA244\/2014"]}],"id":[{"id":"10.13039\/501100006595","id-type":"DOI","asserted-by":"crossref"}]},{"name":"SOP HRD","award":["POSDRU\/159\/1.5\/S\/134378"],"award-info":[{"award-number":["POSDRU\/159\/1.5\/S\/134378"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Mater Sci: Mater Med"],"published-print":{"date-parts":[[2015,6]]},"DOI":"10.1007\/s10856-015-5527-y","type":"journal-article","created":{"date-parts":[[2015,6,17]],"date-time":"2015-06-17T06:16:02Z","timestamp":1434521762000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["Stainless steel surface biofunctionalization with PMMA-bioglass coatings: compositional, electrochemical corrosion studies and microbiological assay"],"prefix":"10.1007","volume":"26","author":[{"given":"L.","family":"Floroian","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Samoila","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Badea","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.","family":"Munteanu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Ristoscu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F.","family":"Sima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"I.","family":"Negut","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. C.","family":"Chifiriuc","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"I. N.","family":"Mihailescu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2015,6,18]]},"reference":[{"key":"5527_CR1","first-page":"12","volume":"1","author":"J Marciniak","year":"1997","unstructured":"Marciniak J. Perspectives of employing of the metallic biomaterials in the reconstruction surgery. Eng Biomater. 1997;1:12\u201320.","journal-title":"Eng Biomater"},{"key":"5527_CR2","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.msea.2005.03.032","volume":"398","author":"YL Zhou","year":"2005","unstructured":"Zhou YL, Niinomi M, Akahori T, Fukui H, Toda H. Corrosion resistance and biocompatibility of Ti\u2013Ta alloys for biomedical applications. Mater Sci Eng A. 2005;398:28\u201336.","journal-title":"Mater Sci Eng A"},{"key":"5527_CR3","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.intermet.2012.03.015","volume":"30","author":"HH Huang","year":"2012","unstructured":"Huang HH, Sun YS, Wu CP, Liu CF, Liaw PK, Kai W. Corrosion resistance and biocompatibility of Ni-free Zr-based bulk metallic glass for biomedical applications. Intermetallics. 2012;30:139\u201343.","journal-title":"Intermetallics"},{"key":"5527_CR4","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1007\/978-3-642-56486-4_7","volume-title":"Titanium in medicine: material science, surface science, engineering biological responses and medical applications","author":"M Textor","year":"2001","unstructured":"Textor M, Sitting C, Frauchiger V, Tosatti S. Titanium in medicine: material science, surface science, engineering biological responses and medical applications. Berlin: Springer; 2001. p. 171."},{"issue":"1","key":"5527_CR5","first-page":"34","volume":"10","author":"V Sansone","year":"2013","unstructured":"Sansone V, Pagani D, Melato M. The effects on bone cells of metal ions released from orthopaedic implants. A review. Clin Cases Miner Bone Metab. 2013;10(1):34\u201340.","journal-title":"Clin Cases Miner Bone Metab"},{"issue":"3","key":"5527_CR6","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1016\/S0010-938X(99)00103-1","volume":"42","author":"DJ Blackwood","year":"2000","unstructured":"Blackwood DJ, Chua AWC, Seah KHW, Thampuran R, Teoh SH. Corrosion behaviour of porous titanium\u2013graphite composites designed for surgical implants. Corros Sci. 2000;42(3):481\u2013503.","journal-title":"Corros Sci"},{"issue":"10","key":"5527_CR7","doi-asserted-by":"crossref","first-page":"3309","DOI":"10.1016\/j.corsci.2011.06.006","volume":"53","author":"K Yaya","year":"2011","unstructured":"Yaya K, Khelfaoui Y, Malki B, Kerkar M. Numerical simulations study of the localized corrosion resistance of AISI 316L stainless steel and pure titanium in a simulated body fluid environment. Corros Sci. 2011;53(10):3309\u201314.","journal-title":"Corros Sci"},{"issue":"10","key":"5527_CR8","doi-asserted-by":"crossref","first-page":"2473","DOI":"10.1016\/j.corsci.2009.06.035","volume":"51","author":"VA Alves","year":"2009","unstructured":"Alves VA, Reis RQ, Santos ICB, Souza DG, de Gon\u00e7alves TF, Pereira-da-Silva MA, Rossi A, da Silva LA. In situ impedance spectroscopy study of the electrochemical corrosion of Ti and Ti\u20136Al\u20134V in simulated body fluid at 25\u00b0C and 37\u00b0C. Corros Sci. 2009;51(10):2473\u201382.","journal-title":"Corros Sci"},{"issue":"4","key":"5527_CR9","doi-asserted-by":"crossref","first-page":"938","DOI":"10.1016\/j.corsci.2007.09.009","volume":"50","author":"NTC Oliveira","year":"2008","unstructured":"Oliveira NTC, Guastaldi AC. Electrochemical behavior of Ti\u2013Mo alloys applied as biomaterial. Corros Sci. 2008;50(4):938\u201345.","journal-title":"Corros Sci"},{"issue":"2","key":"5527_CR10","doi-asserted-by":"crossref","first-page":"796","DOI":"10.1016\/j.corsci.2010.11.014","volume":"53","author":"I Cvijovi\u0107-Alagi\u0107","year":"2011","unstructured":"Cvijovi\u0107-Alagi\u0107 I, Cvijovi\u0107 Z, Mitrovi\u0107 S, Pani\u0107 V, Rakin M. Wear and corrosion behaviour of Ti\u201313Nb\u201313Zr and Ti\u20136Al\u20134V alloys in simulated physiological solution. Corros Sci. 2011;53(2):796\u2013808.","journal-title":"Corros Sci"},{"key":"5527_CR11","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1016\/j.corsci.2012.08.042","volume":"65","author":"C Vasilescu","year":"2012","unstructured":"Vasilescu C, Drob SI, Neacsu EI, Mirza Rosca JC. Surface analysis and corrosion resistance of a new titanium base alloy in simulated body fluids. Corros Sci. 2012;65:431\u201340.","journal-title":"Corros Sci"},{"key":"5527_CR12","first-page":"320","volume":"1","author":"A Kierzkowska","year":"2007","unstructured":"Kierzkowska A, Malinowski M, Krasicka-Cydzik E. Characteristics of anodic layer on Ti6Al4V ELI alloy after bending. Mater Process Technol. 2007;1:320\u201334.","journal-title":"Mater Process Technol"},{"issue":"7","key":"5527_CR13","doi-asserted-by":"crossref","first-page":"1954","DOI":"10.1016\/j.corsci.2008.04.002","volume":"50","author":"CV Vidal","year":"2008","unstructured":"Vidal CV, Mu\u00f1oz AI. Electrochemical characterisation of biomedical alloys for surgical implants in simulated body fluids. Corros Sci. 2008;50(7):1954\u201361.","journal-title":"Corros Sci"},{"issue":"11","key":"5527_CR14","doi-asserted-by":"crossref","first-page":"4296","DOI":"10.1016\/j.corsci.2007.05.018","volume":"49","author":"GT Burstein","year":"2007","unstructured":"Burstein GT, Liu C. Nucleation of corrosion pits in Ringer\u2019s solution containing bovine serum. Corros Sci. 2007;49(11):4296\u2013306.","journal-title":"Corros Sci"},{"issue":"3","key":"5527_CR15","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1016\/j.corsci.2008.12.019","volume":"51","author":"A Shahryari","year":"2009","unstructured":"Shahryari A, Szpunar JA, Omanovic S. The influence of crystallographic orientation distribution on 316LVM stainless steel pitting behavior. Corros Sci. 2009;51(3):677\u201382.","journal-title":"Corros Sci"},{"issue":"6","key":"5527_CR16","doi-asserted-by":"crossref","first-page":"1462","DOI":"10.1016\/j.corsci.2005.05.017","volume":"48","author":"H Shaikh","year":"2006","unstructured":"Shaikh H, Sivaibharasi N, Sasi B, Anita T, Amirthalingam R, Rao BPC, Jayakumar T, Khatak HS. Use of eddy current testing method in detection and evaluation of sensitisation and intergranular corrosion in austenitic stainless steels. Corros Scie. 2006;48(6):1462\u201382.","journal-title":"Corros Scie."},{"issue":"7","key":"5527_CR17","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1016\/j.biomaterials.2004.03.012","volume":"26","author":"G Rondelli","year":"2005","unstructured":"Rondelli G, Torricelli P, Fini M, Giardino R. In vitro corrosion study by EIS of a nickel-free stainless steel for orthopaedic applications. Biomaterials. 2005;26(7):739\u201344.","journal-title":"Biomaterials"},{"issue":"5","key":"5527_CR18","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1016\/j.corsci.2009.02.012","volume":"51","author":"M Cie\u015blik","year":"2009","unstructured":"Cie\u015blik M, Reczy\u0144ski W, Janus AM, Engvall K, Socha RP, Kotarba A. Metal release and formation of surface precipitate at stainless steel grade 316 and Hanks solution interface\u2014inflammatory response and surface finishing effects. Corros Sci. 2009;51(5):1157\u201362.","journal-title":"Corros Sci"},{"issue":"12","key":"5527_CR19","doi-asserted-by":"crossref","first-page":"3429","DOI":"10.1016\/j.corsci.2008.09.002","volume":"50","author":"Y Okazakia","year":"2008","unstructured":"Okazakia Y, Gotoh E. Metal release from stainless steel, Co\u2013Cr\u2013Mo\u2013Ni\u2013Fe and Ni\u2013Ti alloys in vascular implants. Corros Sci. 2008;50(12):3429\u201338.","journal-title":"Corros Sci"},{"key":"5527_CR20","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.1016\/j.apsusc.2007.08.009","volume":"254","author":"D Tanaskovic","year":"2007","unstructured":"Tanaskovic D, Jokic B, Socol G, Popescu A, Mihailescu IN, Petrovic R, Janackovic D. Synthesis of functionally graded bioactive glass\u2014apatite multistructures on Ti substrates by pulsed laser deposition. Appl Surf Sci. 2007;254:1279\u201382.","journal-title":"Appl Surf Sci"},{"key":"5527_CR21","doi-asserted-by":"crossref","first-page":"7981","DOI":"10.1016\/j.apsusc.2007.02.146","volume":"253","author":"E Gyorgy","year":"2007","unstructured":"Gyorgy E, Grigorescu S, Socol G, Mihailescu IN, Figueras A, Janackovic D, Palcevskis E, Zdrentu LE, Petrescu S. Bioactive glass and hydroxyapatite thin films obtained by pulsed laser deposition. Appl Surf Sci. 2007;253:7981\u20136.","journal-title":"Appl Surf Sci"},{"issue":"2","key":"5527_CR22","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1021\/cr010428w","volume":"103","author":"DB Chrisey","year":"2003","unstructured":"Chrisey DB, Pique A, McGill RA, Horwitz JS, Ringeisen BR, Bubb DM, Wu PK. Laser deposition of polymer and biomaterial films. Chem Rev. 2003;103(2):553\u201376.","journal-title":"Chem Rev"},{"key":"5527_CR23","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1007\/978-3-642-03307-0_10","volume-title":"Laser-surface interactions for new materials production tailoring structure and properties","author":"IN Mihailescu","year":"2010","unstructured":"Mihailescu IN, Ristoscu C, Bigi A, Mayer I. Advanced biomimetic implants based on nanostructured coatings synthesized by pulsed laser technologies. In: Miotello A, Ossi P, editors. Laser-surface interactions for new materials production tailoring structure and properties. New York: Springer; 2010. p. 235\u201360."},{"issue":"454","key":"5527_CR24","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1016\/j.tsf.2003.11.145","volume":"453","author":"R Cristescu","year":"2004","unstructured":"Cristescu R, Stamatin I, Mihaescu DE, Ghica C, Albulescu M, Mihailescu IN, Chrisey DB. Pulsed laser deposition of biocompatible polymers: a comparative study in case of pullulan. Thin Solid Films. 2004;453(454):262\u20138.","journal-title":"Thin Solid Films"},{"key":"5527_CR25","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1007\/s00339-004-2619-9","volume":"79","author":"R Cristescu","year":"2004","unstructured":"Cristescu R, Mihaescu DE, Socol G, Stamatin I, Mihailescu IN, Chrisey DB. Deposition of biopolymer thin films by matrix assisted pulsed laser evaporation. J Appl Phys A. 2004;79:1023\u20136.","journal-title":"J Appl Phys A."},{"key":"5527_CR26","first-page":"63","volume-title":"Pulsed laser deposition of thin films: applications\u2014led growth of functional materials","author":"A Pique","year":"2008","unstructured":"Pique A. Deposition of polymers and biomaterials using the matrix assisted pulsed laser evaporation (MAPLE) process. In: Eason R, editor. Pulsed laser deposition of thin films: applications\u2014led growth of functional materials. New York: Wiley; 2008. p. 63\u201384."},{"issue":"9","key":"5527_CR27","first-page":"1170","volume":"11","author":"F Sima","year":"2009","unstructured":"Sima F, Ristoscu C, Popescu A, Mihailescu IN, Kononenko T, Simon S, Radu T, Ponta O, Mustata R, Sima LE, Petrescu SM. Bioglass-polymer thin coatings obtained by MAPLE for a new generation of implants. J Optoelectron Adv Mater. 2009;11(9):1170\u20134.","journal-title":"J Optoelectron Adv Mater"},{"issue":"6","key":"5527_CR28","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1002\/jbm.820240607","volume":"24","author":"T Kokubo","year":"1990","unstructured":"Kokubo T, Kushitani H, Sakka S, Kitsugi T, Yamamuro T. Solutions able to reproduce in vivo surface-structure changes in bioactive glass-ceramic A-W3J. Biomed Mater Res A. 1990;24(6):721.","journal-title":"Biomed Mater Res A."},{"key":"5527_CR29","unstructured":"http:\/\/www.bioeng.nus.edu.sg\/people\/PI\/trau\/Lab_manuals\/Autolab%20manuals\/Fra%20manual%204.9.pdf ."},{"issue":"2","key":"5527_CR30","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.ijpharm.2013.08.026","volume":"463","author":"AM Grumezescu","year":"2014","unstructured":"Grumezescu AM, Holban AM, Andronescu E, Mogosanu GD, Vasile BS, Chifiriuc MC, Lazar V, Andrei E, Constantinescu A, Maniu H. Anionic polymers and 10\u00a0nm Fe3O4@UA wound dressings support human foetal stem cells normal development and exhibit great antimicrobial properties. Int J Pharm. 2014;463(2):146\u201354.","journal-title":"Int J Pharm"},{"key":"5527_CR31","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1142\/9781860949647_0001","volume-title":"future strategies for tissue and organ replacement","author":"LL Hench","year":"2002","unstructured":"Hench LL, Jones JR, Sepulveda P. Bioactive materials for tissue engineering scaffolds. In: Polak JM, Hench LL, Kemp P, editors. future strategies for tissue and organ replacement. London: Imperial College Press; 2002. p. 3\u201324."},{"issue":"1","key":"5527_CR32","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/0022-0248(81)90057-9","volume":"53","author":"G Montel","year":"1981","unstructured":"Montel G, Bonel G, Heughebaert JC, Trombe JC, Rey C. New concepts in the composition, crystallization and growth of the mineral component of calcified tissue. J Cryst Growth. 1981;53(1):74\u201399.","journal-title":"J Cryst Growth"},{"issue":"12","key":"5527_CR33","doi-asserted-by":"crossref","first-page":"1531","DOI":"10.1016\/S0142-9612(00)00309-4","volume":"22","author":"M Aziz-Kerrzo","year":"2001","unstructured":"Aziz-Kerrzo M, Conroy KG, Fenelon AM, Farrell ST, Breslin CB. Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials. Biomaterials. 2001;22(12):1531\u20139.","journal-title":"Biomaterials"},{"issue":"12","key":"5527_CR34","doi-asserted-by":"crossref","first-page":"1913","DOI":"10.1016\/S0013-4686(02)00029-4","volume":"47","author":"AWE Hodgson","year":"2002","unstructured":"Hodgson AWE, Mueller Y, Forster D, Virtanen S. Electrochemical characterization of passive films on Ti alloys under simulated biological conditions. Electrochim Acta. 2002;47(12):1913\u201323.","journal-title":"Electrochim Acta"},{"key":"5527_CR35","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.jelechem.2004.01.011","volume":"568","author":"CEB Marino","year":"2004","unstructured":"Marino CEB, Mascaro LH. EIS characterization of a Ti-dental implant in artificial saliva media: dissolution process of the oxide barrier. J Electroanal Chem. 2004;568:115\u201320.","journal-title":"J Electroanal Chem"},{"issue":"2","key":"5527_CR36","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/S0142-9612(02)00293-4","volume":"24","author":"Z Cai","year":"2003","unstructured":"Cai Z, Shafer T, Watanabe I, Nunn ME, Okabe T. Electrochemical characterization of cast titanium alloys. Biomaterials. 2003;24(2):213\u20138.","journal-title":"Biomaterials"},{"issue":"7","key":"5527_CR37","doi-asserted-by":"crossref","first-page":"2551","DOI":"10.1016\/S1359-6454(98)80039-6","volume":"46","author":"A Pazo","year":"1998","unstructured":"Pazo A, Saiz E, Tomsia AP. Silicate glass coatings on Ti-based implants. Acta Mater. 1998;46(7):2551\u20138.","journal-title":"Acta Mater"},{"key":"5527_CR38","doi-asserted-by":"crossref","first-page":"1564","DOI":"10.1557\/JMR.1992.1564","volume":"47","author":"WC Oliver","year":"1992","unstructured":"Oliver WC, Pharr GM. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments. J Mater Res. 1992;47:1564\u201383.","journal-title":"J Mater Res"},{"issue":"7","key":"5527_CR39","doi-asserted-by":"crossref","first-page":"1487","DOI":"10.1111\/j.1151-2916.1991.tb07132.x","volume":"74","author":"LL Hench","year":"1991","unstructured":"Hench LL. Bioceramics: from concept to clinic. J Am Ceram Soc. 1991;74(7):1487\u2013510.","journal-title":"J Am Ceram Soc"},{"key":"5527_CR40","series-title":"Woodhead Publishing Series in Biomaterials","volume-title":"Metals for Biomedical Devices","author":"N Maruyama","year":"2010","unstructured":"Maruyama N. Mechanical testing of metallic biomaterials. In: Niinomi M, editor. Metals for Biomedical Devices., Woodhead Publishing Series in BiomaterialsAmsterdam: Elsevier; 2010."}],"container-title":["Journal of Materials Science: Materials in Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10856-015-5527-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10856-015-5527-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10856-015-5527-y","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,30]],"date-time":"2019-05-30T23:45:38Z","timestamp":1559259938000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10856-015-5527-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,6]]},"references-count":40,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2015,6]]}},"alternative-id":["5527"],"URL":"https:\/\/doi.org\/10.1007\/s10856-015-5527-y","relation":{},"ISSN":["0957-4530","1573-4838"],"issn-type":[{"value":"0957-4530","type":"print"},{"value":"1573-4838","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,6]]},"article-number":"195"}}