{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T22:19:41Z","timestamp":1767651581092},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2016,1,12]],"date-time":"2016-01-12T00:00:00Z","timestamp":1452556800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Mater Sci: Mater Med"],"published-print":{"date-parts":[[2016,3]]},"DOI":"10.1007\/s10856-015-5664-3","type":"journal-article","created":{"date-parts":[[2016,1,12]],"date-time":"2016-01-12T09:12:13Z","timestamp":1452589933000},"update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Debris of carbon-fibers originated from a CFRP (pEEK) wrist-plate triggered a destruent synovitis in human"],"prefix":"10.1007","volume":"27","author":[{"given":"Antonio","family":"Merolli","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lorenzo","family":"Rocchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marco","family":"De Spirito","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francesco","family":"Federico","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alessandro","family":"Morini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luigi","family":"Mingarelli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francesco","family":"Fanfani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2016,1,12]]},"reference":[{"key":"5664_CR1","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/0010-4361(78)90345-2","volume":"9","author":"GW Hastings","year":"1978","unstructured":"Hastings GW. Carbonfibre composites for orthopaedic implants. Composites. 1978;9:193\u20137.","journal-title":"Composites"},{"key":"5664_CR2","volume-title":"Bone repair biomaterials","year":"2009","unstructured":"Planell J, Best S, Lacroix D, Merolli A, editors. Bone repair biomaterials. Cambridge: Woodhead Publishing Ltd; 2009."},{"issue":"4","key":"5664_CR3","doi-asserted-by":"crossref","first-page":"3821","DOI":"10.1120\/jacmp.v13i4.3821","volume":"13","author":"N Xin-ye","year":"2012","unstructured":"Xin-ye N, Xiaobin T, Changran G, Da C. The prospect of carbon fiber implants in radiotherapy. J Appl Clin Med Phys. 2012;13(4):3821.","journal-title":"J Appl Clin Med Phys"},{"issue":"1","key":"5664_CR4","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1302\/0301-620X.64B1.7068711","volume":"64B","author":"K Tayton","year":"1982","unstructured":"Tayton K, Phillips G, Ralis Z. Long term effects of carbon fibre on soft tissues. J Bone Joint Surg. 1982;64B(1):112\u20134.","journal-title":"J Bone Joint Surg"},{"issue":"13","key":"5664_CR5","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1016\/0142-9612(95)94906-2","volume":"16","author":"C Morrison","year":"1995","unstructured":"Morrison C, Macnair R, MacDonald C, Wykman A, Goldie I, Grant MH. In vitro biocompatibility testing of polymers for orthopaedic implants using cultured fibroblasts and osteoblasts. Biomaterials. 1995;16(13):987\u201392.","journal-title":"Biomaterials"},{"key":"5664_CR6","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1023\/A:1008949311714","volume":"10","author":"A Merolli","year":"1999","unstructured":"Merolli A, Perrone V, Tranquilli-Leali P, Ambrosio L, De Santis R, Nicolais L, Gabbi C. Response to polyetherimide based composite materials implanted in muscle and in bone. J Mater Sci Mater Med. 1999;10:265\u20138.","journal-title":"J Mater Sci Mater Med"},{"issue":"16","key":"5664_CR7","doi-asserted-by":"crossref","first-page":"1804","DOI":"10.1097\/00007632-199808150-00016","volume":"23","author":"T Tullberg","year":"1998","unstructured":"Tullberg T. Failure of a carbon fiber implant. A case report. Spine. 1998;23(16):1804\u20136.","journal-title":"Spine"},{"issue":"4","key":"5664_CR8","doi-asserted-by":"crossref","first-page":"770","DOI":"10.1016\/j.injury.2014.12.011","volume":"46","author":"A Merolli","year":"2014","unstructured":"Merolli A, Rocchi L. A discussion on the limits of carbon-fibres reinforced polymers prompted by a case of destruent synovitis in the wrist. Injury. 2014;46(4):770\u20131.","journal-title":"Injury"},{"key":"5664_CR9","doi-asserted-by":"crossref","first-page":"495302","DOI":"10.1088\/0957-4484\/24\/49\/495302","volume":"24","author":"G Ciasca","year":"2013","unstructured":"Ciasca G, Businaro L, Papi M, Notargiacomo A, Chiarpotto M, De Ninno A, Palmieri V, Carta S, Giovine E, Gerardino A, De Spirito M. Self-assembling of large ordered DNA arrays using superhydrophobic patterned surfaces. Nanotechnology. 2013;24:495302.","journal-title":"Nanotechnology"},{"issue":"4","key":"5664_CR10","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1302\/0301-620X.72B4.2380209","volume":"72","author":"MS Ali","year":"1990","unstructured":"Ali MS, French TA, Hastings GW, Rae T, Rushton N, Ross ERS, Wynn-Jones CH. Carbon fibre composite bone plates. Development, evaluation and early clinical experience. J Bone Joint Surg Br. 1990;72(4):586\u201391.","journal-title":"J Bone Joint Surg Br"},{"key":"5664_CR11","first-page":"179","volume-title":"Encyclopedia of toxicology","year":"2005","unstructured":"Wexler P, editor. Encyclopedia of toxicology, vol. 1. 2nd ed. San Diego: Elsevier; 2005. p. 179\u201382.","edition":"2"},{"issue":"5","key":"5664_CR12","first-page":"915","volume":"28","author":"L Rosenthall","year":"1987","unstructured":"Rosenthall L. Radiophosphate visualization of the foreign body reaction to wear debris from total knee prosthesis. J Nucl Med. 1987;28(5):915\u20137.","journal-title":"J Nucl Med"},{"issue":"2","key":"5664_CR13","first-page":"171","volume":"75","author":"A Sudanese","year":"1990","unstructured":"Sudanese A, Ciappetti G, Baldini N, Stea S, Ciaroni D, Dallari D, Toni A, Giunti A. An evaluation of the \u201cin vivo\u201d and \u201cin vitro\u201d biological reaction and mechanical features of carbon fibre composites. Chir Organi Mov. 1990;75(2):171\u20136.","journal-title":"Chir Organi Mov"},{"issue":"2","key":"5664_CR14","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1002\/jbm.820260202","volume":"26","author":"KA Jockisch","year":"1992","unstructured":"Jockisch KA, Brown SA, Bauer TW, Merritt K. Biological response to chopped-carbon-fiber-reinforced peek. J Biomed Mater Res. 1992;26(2):133\u201346.","journal-title":"J Biomed Mater Res"},{"issue":"13","key":"5664_CR15","doi-asserted-by":"crossref","first-page":"1436","DOI":"10.1097\/00007632-199407000-00002","volume":"19","author":"JW Brantigan","year":"1994","unstructured":"Brantigan JW, McAfee PC, Cunningham BW, Wang H, Orbegoso CM. Interbody lumbar fusion using a carbon fiber cage implant versus allograft bone. An investigational study in the Spanish goat. Spine. 1994;19(13):1436\u201344.","journal-title":"Spine"},{"issue":"6","key":"5664_CR16","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1302\/0301-620X.80B6.8194","volume":"80","author":"K Meister","year":"1998","unstructured":"Meister K, Cobb A, Bentley G. Treatment of painful articular cartilage defects of the patella by carbon-fibre implants. J Bone Joint Surg Br. 1998;80(6):965\u201370.","journal-title":"J Bone Joint Surg Br"},{"issue":"24","key":"5664_CR17","doi-asserted-by":"crossref","first-page":"2744","DOI":"10.1097\/00007632-200112150-00025","volume":"26","author":"D Togawa","year":"2001","unstructured":"Togawa D, Bauer TW, Brantigan JW, Lowery GL. Bone graft incorporation in radiographically successful human intervertebral body fusion cages. Spine. 2001;26(24):2744\u201350.","journal-title":"Spine"},{"issue":"1","key":"5664_CR18","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1023\/B:JMSM.0000010102.26218.d1","volume":"15","author":"GI Howling","year":"2004","unstructured":"Howling GI, Ingham E, Sakoda H, Stewart TD, Fisher J, Antonarulrajah A, Appleyard S, Rand B. Carbon-carbon composite bearing materials in hip arthroplasty: analysis of wear and biological response to wear debris. J Mater Sci Mater Med. 2004;15(1):91\u20138.","journal-title":"J Mater Sci Mater Med"},{"issue":"2","key":"5664_CR19","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1615\/JLongTermEffMedImplants.v18.i2.40","volume":"18","author":"F Medel","year":"2008","unstructured":"Medel F, Kurtz SM, Klein G, Levine H, Sharkey P, Austin M, Kraay M, Rimnac CM. Clinical, surface damage and oxidative performance of poly II tibial inserts after long-term implantation. J Long Term Eff Med Implants. 2008;18(2):151\u201365.","journal-title":"J Long Term Eff Med Implants"},{"issue":"3","key":"5664_CR20","doi-asserted-by":"crossref","first-page":"953","DOI":"10.1002\/jbm.a.32758","volume":"94","author":"SA Hacking","year":"2010","unstructured":"Hacking SA, Pauyo T, Lim L, Legoux JG, Bureau MN. Tissue response to the components of a hydroxyapatite-coated composite femoral implant. J Biomed Mater Res A. 2010;94(3):953\u201360.","journal-title":"J Biomed Mater Res A"},{"issue":"11","key":"5664_CR21","doi-asserted-by":"crossref","first-page":"4296","DOI":"10.1016\/j.actbio.2010.06.002","volume":"6","author":"S Utzschneider","year":"2010","unstructured":"Utzschneider S, Becker F, Grupp TM, Sievers B, Paulus A, Gottschalk O, Jansson V. Inflammatory response against different carbon fiber-reinforced PEEK wear particles compared with UHMWPE in vivo. Acta Biomater. 2010;6(11):4296\u2013304.","journal-title":"Acta Biomater"},{"issue":"6","key":"5664_CR22","doi-asserted-by":"crossref","first-page":"598","DOI":"10.5301\/HIP.2012.10291","volume":"22","author":"RE Field","year":"2012","unstructured":"Field RE, Rajakulendran K, Eswaramoorthy VK, Rushton N. Three-year prospective clinical and radiological results of a new flexible horseshoe acetabular cup. Hip Int. 2012;22(6):598\u2013606.","journal-title":"Hip Int"},{"key":"5664_CR23","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.jmbbm.2012.09.013","volume":"17","author":"EL Steinberg","year":"2013","unstructured":"Steinberg EL, Rath E, Shlaifer A, Chechik O, Maman E, Salai M. Carbon fiber reinforced PEEK Optima\u2013a composite material biomechanical properties and wear\/debris characteristics of CF-PEEK composites for orthopedic trauma implants. J Mech Behav Biomed Mater. 2013;17:221\u20138.","journal-title":"J Mech Behav Biomed Mater"},{"key":"5664_CR24","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1016\/j.msec.2014.10.042","volume":"46","author":"ZS Bagheri","year":"2015","unstructured":"Bagheri ZS, Giles E, El Sawi I, Amleh A, Schemitsch EH, Zdero R, Bougherara H. Osteogenesis and cytotoxicity of a new Carbon Fiber\/Flax\/Epoxy composite material for bone fracture plate applications. Mater Sci Eng C Mater Biol Appl. 2015;46:435\u201342.","journal-title":"Mater Sci Eng C Mater Biol Appl"},{"key":"5664_CR25","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1007\/s10195-014-0311-1","volume":"15","author":"L Tarallo","year":"2014","unstructured":"Tarallo L, Mugnai R, Adani R, Zambianchi F, Catani F. A new volar plate made of carbon-fiber-reinforced-polyetheretherketon for distal radius fracture: analysis of 40 cases. J Orthopaed Traumatol. 2014;15:277\u201383.","journal-title":"J Orthopaed Traumatol"}],"container-title":["Journal of Materials Science: Materials in Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10856-015-5664-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10856-015-5664-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10856-015-5664-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,13]],"date-time":"2024-06-13T19:22:54Z","timestamp":1718306574000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10856-015-5664-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,1,12]]},"references-count":25,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2016,3]]}},"alternative-id":["5664"],"URL":"https:\/\/doi.org\/10.1007\/s10856-015-5664-3","relation":{},"ISSN":["0957-4530","1573-4838"],"issn-type":[{"value":"0957-4530","type":"print"},{"value":"1573-4838","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,1,12]]},"article-number":"50"}}